• 제목/요약/키워드: X-ray Detector

검색결과 456건 처리시간 0.034초

PRELIMINARY FEASIBILITY STUDY OF THE SOLAR OBSERVATION PAYLOADS FOR STSAT-CLASS SATELLITES

  • Moon, Yong-Jae;Cho, Kyung-Seok;Jin, Ho;Chae, Jong-Chul;Lee, Sung-Ho;Seon, Kwang-Il;Kim, Yeon-Han;Park, Young-Deuk
    • Journal of Astronomy and Space Sciences
    • /
    • 제21권4호
    • /
    • pp.329-342
    • /
    • 2004
  • In this paper, we present preliminary feasibility studies on three types of solar observation payloads for future Korean Science and Technology Satellite (STSAT) programs. The three candidates are (1) an UV imaging telescope, (2) an UV spectrograph, and (3) an X-ray spectrometer. In the case of UV imaging telescope, the most important constraint seems to be the control stability of a satellite in order to obtain a reasonably good spatial resolution. Considering that the current pointing stability estimated from the data of the Far ultraviolet Imaging Spectrograph (FIMS) onboard the Korean STSAT-1, is around 1 arc minutes/sec, we think that it is hard to obtain a spatial resolution sufficient for scientific research by such an UV Imaging Telescope. For solar imaging missions, we realize that an image stabilization system, which is composed of a small guide telescope with limb sensor and a servo controller of secondary mirror, is quite essential for a very good pointing stability of about 0.1 arcsec. An UV spectrograph covering the solar full disk seems to be a good choice in that there is no risk due to poor pointing stability as well as that it can provide us with valuable UV spectral irradiance data valuable for studying their effects on the Earth's atmosphere and satellites. The heritage of the FIMS can be a great advantage of developing the UV spectrograph. Its main disadvantage is that two major missions are in operation or scheduled. Our preliminary investigations show that an X-ray spectrometer for the full disk Sun seems to be the best choice among the three candidates. The reasons are : (1) high temporal and spectral X-ray data are very essential for studying the acceleration process of energetic particles associated with solar flares, (2) we have a good heritage of X-ray detectors including a rocket-borne X-ray detector, (3) in the case of developing countries such as India and Czech, solar X-ray spectrometers were selected as their early stage satellite missions due to their poor pointing stabilities, and (4) there is no planned major mission after currently operating Reuven Ramaty High-Energy Solar Spectroscopic Imager (RHESSI) mission. Finally, we present a preliminary design of a solar X-ray spectrometer covering soft X-ray (2 keV) to gamma ray (10 MeV).

슬개골 엑스선 영상 촬영을 위한 보조기구의 개발과 활용 (Development and use of Supporting Device for Patellar X-ray Imaging)

  • 이도병;서승준;최현우;이상훈;김종기
    • 대한의용생체공학회:의공학회지
    • /
    • 제41권4호
    • /
    • pp.165-171
    • /
    • 2020
  • In this study, it focuses on the development of radiographic devices for patellar imaging. On the previous X-ray examination of patella and patellofemoral joint, it analyzed the problems which could affect the results: unstable patients' pose, radiation exposure, and deterioration of image quality. The purpose of the research is to propose a future use of a developed device with an explanation of the process, function, and advantage of the device including the methods. The device is developed to focus on the diagnosis of the longitudinal and longitudinal fractures of the patella and patella/femoral joint, displacement such as dislocation, bone formation, stenosis of the patella/femorla joint, and cartilage wear. Due to the patient's anxious posture, it caused a shaking image, overlapping structures, and etcs, these factors challenge to diagnose accurately. In addition, the existing Settegast method and Hughston method, which are most frequently performed in the hospital field, are not suitable for the presence or absence of features or dislocation due to the heavy load on the patella of the patient. The developed device requires patients in a lying position and placing only their leg on the device, it increases the conveniences of the examination and decreases unnecessary radiation exposure of the patient except the patellar examination area. Moreover, one of the systems in the device fixes the detector, where the patients no longer need to hold the detector nor be in unstable posture, but describes the structure of the patella/femoral joint more clearly. Hoping the device will apply to more patients.

$HgI_2$ 방사선 검출기의 누설전류 저감에 관한 연구 (Study on the dark current reduction of $HgI_2$ radiation detector)

  • 신정욱;강상식;김진영;김경진;박성광;조흥래;이형원;남상희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 추계학술대회 논문집 Vol.17
    • /
    • pp.456-459
    • /
    • 2004
  • Analog film/screen systems have been being changed to a digital x-ray imaging device using direct conversion materials. Photocoductors for a direct detection flat-panel imager require high x-ray absorption, ionization and charge collection, low leakage current and large area deposition. In this work, $HgI_2$ films with excellent properties for x-ray detector were deposited by screen printing method. The thickness of $HgI_2$ film was about $150\;{\mu}m$. The passivation layer is fabricated using a-Se and parlyene, the both fabrication $HgI_2$ film were compared for analyzing the leakage current reduction. We measured electrical properties-leakage current, photosensitivity, SNR though I-V measurement, As the result, $HgI_2$ film using a-Se passivation layer had the greater

  • PDF

Contrast Method를 이용한 디지털 X선 영상과 필름 영상의 영상 질(Quality) 평가 (Image Quality Evaluation of Digital X-ray Image and Film Image using Contrast Method)

  • 박지군;정봉재;최장용;강상식
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제34권1호
    • /
    • pp.9-15
    • /
    • 2011
  • 본 논문은 현재 임상에서 사용되고 있는 비정질 셀레늄을 이용한 평판형 X선 영상 검출기를 통해 획득된 영상의 변조전달함수(MTF)에 대한 정량적인 값을 도출하였다. 영상 질(quality)의 주요변수인 MTF의 측정은 먼저 test pattern 영상을 획득한 다음, contrast method를 이용하여 공간주파수(spatial frequency)에서의 line profile을 디지털 값으로 획득하여 MTF를 계산하였다. 측정 결과, test pattern 영상에서 3.0 lp/mm에서 36.1%의 MTF 값을 나타냈으며, 종래의 필름 영상보다 약 2배 높은 해상력을 가짐을 알 수 있었다. 측정된 값은 비정질 셀레늄을 이용한 직접방식의 디지털 방사선 검출기의 임상적 사용가치가 충분함을 뒷받침 할 수 있는 기초 자료로서 제공될 수 있을 것으로 판단된다.

a-Se에 첨가된 Iodine의 조성비 변화에 따른 X선 검출특성 연구 (The Study on X-ray Detection Characteristics of Radiation Detective Sensor with Changing Composition Ratio of Iodine in a-Se)

  • 차병열;강상식;이규홍;김재형;남상희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 추계학술대회 논문집 Vol.15
    • /
    • pp.399-402
    • /
    • 2002
  • This paper is researched that electric characteristic of Digital x-ray radiography technique with changing composition ratio of Iodine. Dopant material, Iodine is evaporated with amorphous selenium. Thorugh the old papers say, doponted Iodine will be down the created trap level because of Arsenic dopant material in amorphous selenium. Arsenic material of Composition ratio in amorphous selenium is fixed with 0.3% and test sample is deposited composition of 30, 100, 300, 500, 700ppm with thermal evaporate system. Experimental measurement is performed by dark current and x-ray sensitivity in amorphous selenium based radition detector sensor. Fabricated test sample thickness is $30{\mu}m$ and injected voltage is $3{\mu}m$$6{\mu}m$$9{\mu}m$ to both electrode. Experimental results showed that the net charge of composition rate of 30ppm is 398.88 pc/mR/$cm^2$ very high. And increase of the Iodine composition ratio is tendency to the decrease of net charge. Doping changing composition of Iodine in amorphous selenium detector offered to basical information of amorphous selenium material.

  • PDF

고분해능 및 고민감도를 위한 준 블록 섬광체를 사용한 네 층의 반응 깊이 측정 검출기 설계 (Design a Four Layer Depth-Encoding Detector Using Quasi-Block Scintillator for High Resolution and Sensitivity)

  • 이승재;조병두
    • 한국방사선학회논문지
    • /
    • 제18권2호
    • /
    • pp.65-71
    • /
    • 2024
  • 소동물용 양전자방출단층촬영기기(positron emission tomography, PET)의 고분해능과 고민감도를 달성하기 위해 매우 가늘고 긴 섬광 픽셀을 사용하여 검출기를 구성한다. 이러한 섬광 픽셀의 구조로 인해 시스템의 관심 시야 외곽에서 공간분해능 저하 현상이 발생한다. 이를 해결하기 위해 반응 깊이를 측정하여 공간분해능을 향상시키고, 준블록 섬광체를 사용하여 민감도를 향상시킬 수 있는 검출기를 설계하였다. 12.6 mm x 12.6 mm x 3 mm 크기의 준블록 섬광체를 네 층으로 배열하고, 모든 옆면에 광센서를 배치하여 감마선과 섬광체가 상호작용하여 발생된 빛을 수집하도록 설계하였다. 설계한 검출기의 성능 평가를 위해 DETECT2000 시뮬레이션을 수행하였다. 각 층별 섬광체 내에서 1.3 mm부터 11.3 mm까지 1 mm 간격으로 감마선 이벤트를 발생시켜 평면 영상을 획득하였다. 11 x 11 배열의 평면 영상에서 각 위치별 공간분해능과 피크 간 거리를 측정하였다. 측정된 공간분해능의 평균은 0.25 mm였으며, 피크 간 거리의 평균은 1.0 mm였다. 이를 통해 모든 위치가 서로 분리됨을 확인할 수 있었다. 또한 모든 층은 빛의 신호가 서로 분리되어 측정되므로 감마선과 상호작용한 섬광체의 층을 완벽히 분리해낼 수 있었다. 설계한 검출기를 소동물용 PET 시스템의 검출기로 사용할 경우, 우수한 공간분해능과 민감도를 달성하여 영상의 질을 향상시킬 수 있을 것으로 판단된다.

가상 Frisch-그리드를 이용한 CdZnTe 감마선 소자 제작 (Fabrication of Virtual Frisch-Grid CdZnTe ${\gamma}$-Ray Detector)

  • 박찬선;김필수;조평곤;김정민;최종학;김기현
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제37권4호
    • /
    • pp.253-259
    • /
    • 2014
  • Traveling heater method(THM) 방법을 이용하여 성장시킨 CdZnTe(CZT) 단결정 방사선 소자에 대한 고에너지(high energy) 감마선 에너지 분해능(energy resolution)을 평가하고자 $6{\times}6{\times}12mm^3$ 크기의 CZT 소자를 제작하였다. 두꺼운 방사선 소자의 경우, 전자에 비해 상대적으로 이동속도가 느린 정공(hole)으로 인해 발생하는 hole-tailing 효과가 심화되어 고에너지 영역의 에너지 분해능이 저하되는 현상이 발생한다. 전자(electron)와 정공(hole)의 두 개의 전하 운반자(charge carrier) 중에서 하나의 전하 운반자를 선택적으로 수집하여 에너지 분해능을 높이는 것이 가능하다. 가상 Frisch-그리드(virtual Frisch-grid) 소자는 소자 내부의 가중 퍼텐셜(weighting potential)을 조절하여 전자에 의한 유도전류(induced current)만을 선택적으로 이용하는 방법으로써 제작 과정과 적용이 용이하다. 본 연구에서는 THM 방법으로 성장한 큰 부피의 CZT 방사선 소자의 특성과 가상 Frisch-그리드의 효용성을 평가하였다. 가상 Frisch-그리드의 적절한 위치와 너비는 Maxwell ver.14(ANSYS, 미국)를 이용하여 모의실험으로 정하였다. $^{137}Cs$ 동위원소를 이용한 펄스 높이 스펙트럼(pulse height spectrum) 측정에서 가상 Frisch-그리드를 적용했을 때 662 keV 피크에 대해 2.2%의 에너지 분해능을 확인할 수 있었다.

X선 스펙트럼 모델을 이용한 DR 화소값과 디텍터 흡수에너지의 관계에 대한 정량적 분석 (Quantitative Analysis of Digital Radiography Pixel Values to absorbed Energy of Detector based on the X-Ray Energy Spectrum Model)

  • 김도일;김성현;호동수;최보영;서태석;이재문;이형구
    • 한국의학물리학회지:의학물리
    • /
    • 제15권4호
    • /
    • pp.202-209
    • /
    • 2004
  • 현재 평판 디텍터를 이용한 디지털 방사선 촬영기술은 방사선 진단 기술 분야에 있어서 매우 중요하고 유용하게 사용되고 있다. 비정질 실리콘 광센서를 사용하는 디지털 방사선 촬영기에는 흡수되는 방사선 에너지를 가시광선으로 변환하는 신틸레이터로 보통 CsI(TI)를 사용한다. 신틸레이터에서 만들어진 가시광선은 이차원 평면으로 구성된 비정실 실리콘 광 다이오드에서 전기적 신호로 전환된다. 좋은 질의 영상을 얻기 위해서는 디지털 방사선 촬영기(Digital Radiography, DR) 디텍터의 방사선에 대한 세부적인 특성 연구가 필수적이다. 이러한 이유로 조사선량과 디지털 방사선 촬영기의 신호의 관계에 대해서 많은 연구가 이루어졌지만 현재까지의 연구에서는 고정된 관전압의 조건에서 두 변수의 관계에 대한 연구가 이루어졌다. 이에 본 연구에서는 X선 스펙트럼 모델인 SPEC-78을 사용하여 조사선량 대신 디텍터에 흡수되는 에너지와 디지털 방사선 촬영기의 신호와의 관계를 규명하였다. SPEC-78의 주요 입력변수인 X-ray 튜브의 고유 필터 값을 구하기 위해 조사선량을 측정하여 계산한 조사선량과 비교하였다. 물질에 흡수되는 X-ray의 에너지를 계산하는 알고리즘을 상정하여 디텍터에 흡수되는 에너지를 계산하고 다양한 조건에서 실제 X선 영상의 화소값을 획득하였다. 두변수의 관계를 이용해 특성곡선을 얻었으며 이 결과를 검증하기 위해서 물과 알루미늄으로 제작된 팬텀을 이용하였다. 다양한 조건에서 팬텀 영상의 화소값을 측정하였고 특성곡선과 비교하였다 이러한 과정으로 진행된 연구의 결과로 디텍터에 흡수되는 에너지와 디지털 방사선 촬영기의 신호는 거의 선형적임을 알 수 있었다. 또한 팬텀을 이용한 실험에서도 산란된 광자의 영향으로 유발된 약간의 오차에도 불구하고 측정되어진 화소값은 특성곡선과 잘 일치하였다 본 연구를 통해 규명되어진 두 변수의 관계는 예상과 거의 일치하였지만 산란선에 대한 부분은 흡수에너지 계산 알고리즘에서 빠져있어 더 연구가 되어야 할 부분이다. 본 연구를 통해 얻어진 자료들은 디지털 방사선 촬영기의 전처리 과정에 있어서 중요한 정보를 제공할 수 있을 것이라 생각된다.

  • PDF

Properties of Infrared Detector and Growth for HgCdTe Epilayers

  • 홍광준;유상하
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 추계학술대회 논문집 Vol.16
    • /
    • pp.116-119
    • /
    • 2003
  • [ $Hg_{1-x}Cd_xTe$ ] (MCT) was grown by hot wall epitaxy method. Prior to the MCT growth, the CdTe (111) buffer layer was grown on the GaAs substrate at the temperature of 590 C for 15 min. When the thickness of the CdTe buffer layer was 5 m or thicker, the full width at half maximum values obtained from the x-ray rocking curves were found to significantly decrease. After a good quality CdTe buffer layer was grown, the MCT epilayers were grown on the CdTe (111) /GaAs substrate at various temperature in situ. The crystal quality for those epilayers was investigated by means of the x-ray rocking curves and the photocurrent experiment. The photoconductor characterization for the epilayers was also measured. The energy band gap of MCT was determined from the photocurrent measurement and the x composition rates from the temperature dependence of the energy band gap were turned out.

  • PDF