• Title/Summary/Keyword: X-ray CT Analysis

Search Result 224, Processing Time 0.028 seconds

The electronic structure of the ion-beam-mixed Pt-Cu alloys by XPS and XANES

  • Lim, K.Y.;Lee, Y.S.;Chung, Y.D.;Lee, K.M.;Jeon, Y.;Whang, C.N.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1998.02a
    • /
    • pp.133-133
    • /
    • 1998
  • In the thin film alloy formation of the transition metals ion-beam-mixing technique forms a metastable structure which cannot be found in the arc-melted metal alloys. Sppecifically it is well known that the studies about the electronic structure of ion-beam-mixed alloys pprovide the useful information in understanding the metastable structures in the metal alloy. We studied the electronic change in the ion-beam-mixed ppt-Ct alloys by XppS and XANES. These analysis tools pprovide us information about the charge transfer in the valence band of intermetallic bonding. The multi-layered films were depposited on the SiO2 substrate by the sequential electron beam evapporation at a ppressure of less than 5$\times$10-7 Torr. These compprise of 4 ppairs of ppt and Cu layers where thicknesses of each layer were varied in order to change the alloy compposition. Ion-beam-mixing pprocess was carried out with 80 keV Ae+ ions with a dose of $1.5\times$ 1016 Ar+/cm2 at room tempperature. The core and valence level energy shift in these system were investigated by x-ray pphotoelectron sppectroscoppy(XppS) pphotoelectrons were excited by monochromatized Al K a(1486.6 eV) The ppass energy of the hemisppherical analyzer was 23.5 eV. Core-level binding energies were calibrated with the Fermi level edge. ppt L3-edge and Cu K-edge XANES sppectra were measured with the flourescence mode detector at the 3C1 beam line of the ppLS (ppohang light source). By using the change of White line(WL) area of the each metal sites and the core level shift we can obtain the information about the electrons pparticippating in the intermetallic bonding of the ion-beam-mixed alloys.

  • PDF

Shaping ability and apical debris extrusion after root canal preparation with rotary or reciprocating instruments: a micro-CT study

  • Emmanuel Joao Nogueira Leal da Silva;Sara Gomes de Moura;Carolina Oliveira de Lima;Ana Flavia Almeida Barbosa;Waleska Florentino Misael;Mariane Floriano Lopes Santos Lacerda;Luciana Moura Sassone
    • Restorative Dentistry and Endodontics
    • /
    • v.46 no.2
    • /
    • pp.16.1-16.11
    • /
    • 2021
  • Objectives: The aim of this study was to evaluate the shaping ability of the TruShape and Reciproc Blue systems and the apical extrusion of debris after root canal instrumentation. The ProTaper Universal system was used as a reference for comparison. Materials and Methods: Thirty-three mandibular premolars with a single canal were scanned using micro-computed tomography and were matched into 3 groups (n = 11) according to the instrumentation system: TruShape, Reciproc Blue and ProTaper Universal. The teeth were accessed and mounted in an apparatus with agarose gel, which simulated apical resistance provided by the periapical tissue and enabled the collection of apically extruded debris. During root canal preparation, 2.5% sodium hypochlorite was used as an irrigant. The samples were scanned again after instrumentation. The percentage of unprepared area, removed dentin, and volume of apically extruded debris were analyzed. The data were analyzed using 1-way analysis of variance and the Tukey test for multiple comparisons at a 5% significance level. Results: No significant differences in the percentage of unprepared area were observed among the systems (p > 0.05). ProTaper Universal presented a higher percentage of dentin removal than the TruShape and Reciproc Blue systems (p < 0.05). The systems produced similar volumes of apically extruded debris (p > 0.05). Conclusions: All systems caused apically extruded debris, without any significant differences among them. TruShape, Reciproc Blue, and ProTaper Universal presented similar percentages of unprepared area after root canal instrumentation; however, ProTaper Universal was associated with higher dentin removal than the other systems.

Analysis of Relativity Between Invasiveness on Chest of Tomographic Finding and Histopathologic Invasiveness (종격동 종양의 전산화 단층촬영(CT)소견, 수술소견 및 병리조직학적 침윤도 사이의 상관성 분석)

  • 김용희;이현우
    • Journal of Chest Surgery
    • /
    • v.30 no.8
    • /
    • pp.780-785
    • /
    • 1997
  • Mediastinal tumor had been fascinated by its location on heart, great vessels, esophagus, and nervous tissue, its convenience of surgical treatment and superiority of its operative result. Between January 1989 and June 1995, eighty-seven patients with mediastinal tumor which were treated surgically in the Department of Thoracic and Cardiovascular Surgery, Asan Medical Center, School of Medicine, University of Ulsan. To provide the appropriate surgical management of mediastinal tumor, the demographic data, diagnostic evaluation, clinical presentation, location, size, operative finding and histopathologic distribution were reviewed and we analyzed relativity between invasiveness in chest computed tomographic finding or invasiveness on operative finding and histopathologic invasiveness. The anterosuperior mediastinum was the most commonly involved site of a mediastinal tumor(57%), followed by the posterior mediastinum(35%) and middle mediastinum(8%). The most frequently encountered tumors were thymic neoplasia(31%), followed by primary cyst(22%), neurogenic tumor(22%) and teratoma(10%) in decreasing order of frequency. Histopathologically invasive tumors were present in 17 patients(20%) and its site included anterosuperior mediastinum(16%) and posterior mediastinum(4%). All patients in this study underwent chest CT. In chest CT's finding, 15 patients(17%) showed invasiveness. A total excision of the tumor was performed 80 patients(92%), subtotal excision 6 patients(7%) and biopsy only 1 patient(2%). In operative finding, 14 patients(16%) were suspected invasiveness. The mean size of the tumor was 6.0$\pm$ 3.2cm. In anterosuperior mediastinum, the mean size was 6.2$\pm$3.1cm, in middle mediastinum, it was 3.9$\pm$1.1cm, in posterior mediastinum, it was 5.8$\pm$2.6cm. In malignant tumors, the mean size was 7.3$\pm$4.6cm, in benign tumor, it was 5.5$\pm$2.6cm(P<0.05). Relativity between histopathological invasiveness(17 patients) and invasiveness in chest CT's finding(15 patients) included sensitivity 35%, specificity 87% and predictability 35%, relativity between histopathological invasiveness(17 patients) and invasiveness on operative finding included sensitivity 52%, specificity 93% and predictability 64%. In conclusion, since it was proved that the compatibility of preoperative chest CT findings or operative findings and histopathological invasiveness is quite low, it is considered that wide excision of the mediastinal tumor except cystic lesion including adjacent tissues would yield better postoperative results.

  • PDF

Comparative Analysis of Bone Mineral Contents with Dual-Energy Quantitative Computed Tomography (이중에너지광자선의 전산화단층촬영술을 이용한 정량적 골무기물함량의 비교분석)

  • Choi, Tae-Jin;Yoon, Seon-Min;Kim, Ok-Bae;Lee, Sung-Moon;Suh, Soo-Jhi
    • Radiation Oncology Journal
    • /
    • v.15 no.2
    • /
    • pp.153-158
    • /
    • 1997
  • Purpose : The Dual-Energy Quantitative Computed Tomography(DEQCT) was compared with bone equivalent $K_2HPO_4$ standard solution and ash weight of animal cadaveric trabecular bone in the measurement of bone mineral contents(BMC). Method and Materials : The attenuation coefficient of tissues highly depends on the radiation energy density and effective atomic number of composition, The bone mineral content of DEQCT in this experiments was determined from empirical constants and mass attenuation coefficients of bone,fat and soft tissue equivalent solution in two photon spectra. In this experiments, the BMC of DEQCT with 80 and $120kV_p$ X rays was compared to ash weight of animal trabecular bone. Results : We obtained the mass attenuation coefficient of 0.2409 0.5608 and 0.2206 in $80kV_p$, and 0.2046, 0.3273 and $0.1971cm^2/g$ in $120kV_p$ X-ray spectra for water bone and fat equivalent materials, respectively. The BMC with DEQCT was acomplished with empirical constants $K_1=0.3232,\;K_2$=0.2450 and mass attenuation coefficients has very closed to ash weight of animal trabecular bone The BMC of empirical DEQCT and that of manufacturing DEQCT were correlated with ash weight as a correlation r= 0.998 and r= 0.996, respectively. Conclusion : The BMC of empirical DEQCT using the experimental mass attenuation coefficients and that of manufacture have showed very close to ash weight of animal trabecular bone.

  • PDF

Analyze Technologies and Trends in Commercialized Radiology Artificial Intelligence Medical Device (상용화된 영상의학 인공지능 의료기기의 기술 및 동향 분석)

  • Chang-Hwa Han
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.6
    • /
    • pp.881-887
    • /
    • 2023
  • This study aims to analyze the development and current trends of AI-based medical imaging devices commercialized in South Korea. As of September 30, 2023, there were a total of 186 AI-based medical devices licensed, certified, and reported to the Korean Ministry of Food and Drug Safety, of which 138 were related to imaging. The study comprehensively examined the yearly approval trends, equipment types, application areas, and key functions from 2018 to 2023. The study found that the number of AI medical devices started from four products in 2018 and grew steadily until 2023, with a sharp increase after 2020. This can be attributed to the interaction between the advancement of AI technology and the increasing demand in the medical field. By equipment, AI medical devices were developed in the order of CT, X-ray, and MR, which reflects the characteristics and clinical importance of the images of each equipment. This study found that the development of AI medical devices for specific areas such as the thorax, cranial nerves, and musculoskeletal system is active, and the main functions are medical image analysis, detection and diagnosis assistance, and image transmission. These results suggest that AI's pattern recognition and data analysis capabilities are playing an important role in the medical imaging field. In addition, this study examined the number of Korean products that have received international certifications, particularly the US FDA and European CE. The results show that many products have been certified by both organizations, indicating that Korean AI medical devices are in line with international standards and are competitive in the global market. By analyzing the impact of AI technology on medical imaging and its potential for development, this study provides important implications for future research and development directions. However, challenges such as regulatory aspects, data quality and accessibility, and clinical validity are also pointed out, requiring continued research and improvement on these issues.

Bone regeneration effects of human allogenous bone substitutes: a preliminary study

  • Lee, Deok-Won;Koo, Ki-Tae;Seol, Yang-Jo;Lee, Yong-Moo;Ku, Young;Rhyu, In-Chul;Chung, Chong-Pyoung;Kim, Tae-Il
    • Journal of Periodontal and Implant Science
    • /
    • v.40 no.3
    • /
    • pp.132-138
    • /
    • 2010
  • Purpose: The purpose of this study was to compare the bone regeneration effects of cortical, cancellous, and cortico-cancellous human bone substitutes on calvarial defects of rabbits. Methods: Four 8-mm diameter calvarial defects were created in each of nine New Zealand white rabbits. Freeze-dried cortical bone, freeze-dried cortico-cancellous bone, and demineralized bone matrix with freeze-dried cancellous bone were inserted into the defects, while the non-grafted defect was regarded as the control. After 4, 8, and 12 weeks of healing, the experimental animals were euthanized for specimen preparation. Micro-computed tomography (micro-CT) was performed to calculate the percent bone volume. After histological evaluation, histomorphometric analysis was performed to quantify new bone formation. Results: In micro-CT evaluation, freeze-dried cortico-cancellous human bone showed the highest percent bone volume value among the experimental groups at week 4. At week 8 and week 12, freeze-dried cortical human bone showed the highest percent bone volume value among the experimental groups. In histologic evaluation, at week 4, freeze-dried cortico-cancellous human bone showed more prominent osteoid tissue than any other group. New bone formation was increased in all of the experimental groups at week 8 and 12. Histomorphometric data showed that freeze-dried cortico-cancellous human bone showed a significantly higher new bone formation percentile value than any other experimental group at week 4. At week 8, freeze-dried cortical human bone showed the highest value, of which a significant difference existed between freeze-dried cortical human bone and demineralized bone matrix with freeze-dried cancellous human bone. At week 12, there were no significant differences among the experimental groups. Conclusions: Freeze-dried cortico-cancellous human bone showed swift new bone formation at the 4-week healing phase, whereas there was less difference in new bone formation among the experimental groups in the following healing phases.

Evaluation of Lymph Node Staging of Chest CT in NSCLCa (비소세포 폐암의 임파절 병기판정에 대한 흉부 전산화 단층 촬영의 효용성 연구)

  • Sung, Sook-Whan;Kim, Young-Tae;Kim, Doo-Sang;Kim, Joo-Hyun;Lim, Jung-Ki
    • Journal of Chest Surgery
    • /
    • v.31 no.3
    • /
    • pp.271-278
    • /
    • 1998
  • In order to access the value of computed tomography in mediastinal LN staging of NSCLCa, 581 LN stations of 77 patients were selected from 552 patients who were diagnosed as Lung Ca and operated in Seoul National University Hospital from 1992 to 1995. The selection criteria were as follows ; the patients 1) whose preoperative chest CTs were available; 2) underwent curative resection (lobectomy or more) with complete lymph node dissection; 3) whose final pathologic diagnosis were proven to be non-small cell lung cancer. We adopted Receiver Operating Characteristic curve method to determine a proper size criterion for diagnosing malignant mediastinal adenopathy. From curve analysis, we decided the size criterion of lymph node to 1 cm in their short axis. Using this size criterion, it's sensitivity was 43.9%, specificity was 87.4%, and accuracy was 83.1%. Eventhough we couldn't determine the precise size criterion for the adenoca, it seemed that shorter than 1 cm size criterion should be applied in that particular cell type. Lymph node stations associated with the tuberculosis or bronchiectasis tend to be overestimated in nodal staging and have relatively high false positive rate. The low sensitivity of CT scan suggest that radical and complete dissection or precise mediastinal lymph node evaluation through the surgical approach is mandatory.

  • PDF

The Effect of Irradiation and Cis-diamminedichloroplatinum(II) in the Rat Brain : Analysis of Histopathology at 3 and 6 Months after Treatment (횐쥐 뇌에 방사선조사와 Cis-diamminedichloroplatinum(II)의 효과 : 치료 후 3개월과 6개월에서의 조직학적분석)

  • Lee Kyung-Ja;Chang Seung-Hee;Koo Heasoo
    • Radiation Oncology Journal
    • /
    • v.16 no.2
    • /
    • pp.125-138
    • /
    • 1998
  • Purpose : To evaluate the late effect(3 and 6 months) of cis-diarnrninedichlo-roplatinum(II)(cisplatin) on the radiation brain damage when the cisplatin was intraperitoneally infused immediately after whole brain irradiation in the rats. Materials and Methods : The histolopathological findings of the brain were examined in rat brains at 3 and 6 months after the treatment. The rats were irradiated(20 or 22.5 Gy, RT) or cisplatin was injected intraperitoneally(2,4, or 8mg/kg, CT) and in combined treatment group, cisplatin(2mg/kg) was injected immediately after irradiation(20 or 22.5 Gr). Histopathological examination was done mostly in irradiation or cisplatin alone groups, because the rats in combined group died during experimental period except 2 rats. Results : The rats treated with cisplatin showed marked epithelial vacuolation with perivascular edema and vascular dilatation in choroid plexus at 3 months as well as multifocal necrosis involving fimbria and cerebellar hemispheres at 3 and 6 months. The changes were more prominent in rats with 2mg/kg injection compared to rats with 8mg/kg injection. The rats with RT and combined CT and RT showed characteristic delayed irradiation effects such as focal coagulation necrosis and vascular changes, which were more marked than previous reports Prominent perivascular and leptomenin-geal astrocytic Proliferation was well documented by anti-GFAP antibody. Cisplatin treatment did not enhance the effect of radiation-induced changes of blood vessels and astrocytic proliferation. Conclusion : The focal necrosis was the most consistently noted finding in this study, it suggested the possibility to use this as an evaluation factor for combined effects of RT and cisplatin.

  • PDF

The effects of zoledronic acid on the progression of experimental periodontitis in rats: histological and microtomographic analyses

  • de Marcelos, Priscylla Goncalves Correia Leite;da Cruz Perez, Danyel Elias;Soares, Diego Moura;de Araujo, Samuel Silva;Evencio, Liriane Baratella;Pontual, Maria Luiza dos Anjos;Ramos-Perez, Flavia Maria de Moraes
    • Journal of Periodontal and Implant Science
    • /
    • v.51 no.4
    • /
    • pp.264-275
    • /
    • 2021
  • Purpose: Periodontitis is considered a local risk factor for medication-related osteonecrosis of the jaws (MRONJ). However, little is known about the progression of periodontitis in the presence of zoledronic acid (ZOL). The aim of this study was to evaluate the effects of the systemic use of ZOL on the progression of experimental periodontitis (EP) in rats, as ZOL could modulate the progression of periodontitis and concomitantly cause MRONJ in individuals with periodontitis. Methods: Forty-eight male Wistar rats were randomly distributed in 6 groups (n=8 each). To induce EP, ligatures were placed around the right first mandibular molars. Three groups were treated with ZOL (0.15 mg/kg/week, intraperitoneal), and 3 with 0.9% saline solution (controls). In the ZOL/Lig30 and ZOL/Lig 15 groups, after 4 weeks of treatment with ZOL, EP was induced and euthanasia was performed after 30 and 15 days of EP induction, respectively. In both groups, the animals continued to receive ZOL after EP until the end of the experiment. In the Lig/ZOL group, EP was induced first, and 15 days later, ZOL was administered for 8 weeks, with euthanasia 1 week after the last dose. After euthanasia, the mandibles were evaluated using micro-computed microtomography (micro-CT) and histomorphometry. Bone loss was measured, and the presence of osteonecrosis was evaluated histologically. The data were evaluated using the Student t-test and the Mann-Whitney test, with a significance level of 5%. Results: In the Lig/ZOL group, micro-CT revealed less alveolar bone resorption in the distal root (P<0.01) than in the control group (Lig/Con). Histomorphometric analysis confirmed less alveolar bone resorption in the Lig/ZOL group (P=0.001). Histologically, osteonecrosis was more common in the ZOL groups. Conclusion: ZOL decreased alveolar bone resorption in rats with EP. However, it presented a higher risk for MRONJ.

A Study on the Luminescence Properties of Eu3+ Ions Doped Vanadate (Eu3+ 이온이 첨가된 바나듐산염의 형광특성 연구)

  • Kang, Yeonhee;Yoon, Changyong
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.3
    • /
    • pp.445-451
    • /
    • 2019
  • The fluorescence intensity and fluorescence lifetime of $Ba_2GdV_3O_{11}$, a vanadate compound based on $Ba^{2+}$ ion, were investigated by adding $Eu^{3+}$ as a rare earth ion which is an alkaline earth metal, which is distributed around active ions and has a large influence on fluorescent properties when used as a host in a phosphor. $Ba_2GdV_3O_{11}:Eu^{3+}$ phosphor was synthesized by solid state method and the crystallinity of the phosphor was confirmed by X - ray diffraction analysis. The fluorescence properties of the $Ba_2GdV_3O_{11}:Eu^{3+}$ phosphor were measured using optical and laser. The energy transfer and diffusion of the $Ba_2GdV_3O_{11}:Eu^{3+}$ phosphor are highly dependent on the concentration of $Eu^{3+}$. When the concentration of $Eu^{3+}$ is low, it shows strong fluorescence to the CT band. However, as the concentration of $Eu^{3+}$ increases, the fluorescence due to 4f - 4f transition is strong. The concentration of $Eu^{3+}$ ion increased and the energy between ions was diffused, and the lifetime of fluorescence decreased. Energy transfer occurs between two $Eu^{3+}$ ions at low $Eu^{3+}$ concentration and energy diffusion occurs at high $Eu^{3+}$ concentration.