• Title/Summary/Keyword: X-Ray scattering

Search Result 455, Processing Time 0.031 seconds

Growth and Photocurrent Properties of $CuGaSe_2$ Single Crystal ($CuGaSe_2$ 단결정 박막 성장과 광전류 특성)

  • K.J. Hong
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2003.03a
    • /
    • pp.81-81
    • /
    • 2003
  • The stochiometric mixture of evaporating materials for the CuGaSe$_2$ single crystal thin films were prepared from horizontal furnace. Using extrapolation method of X-ray diffraction patterns for the polycrystal CuGaSe$_2$, it was found tetragonal structure whose lattice constant no and co were 5.615$\AA$ and 11.025$\AA$, respectively. To obtains the single crystal thin films, CuGaSe$_2$ mixed crystal was deposited on throughly etched GaAs(100) by the Hot Wall Epitaxy(HWE) system. The source and substrate temperature were 61$0^{\circ}C$ and 45$0^{\circ}C$ respectively, and the growth rate of the single crystal thin films was about 0.5${\mu}{\textrm}{m}$/h. The crystalline structure of single crystal thin films was investigated by the double crystal X-ray diffraction(DCXD). Hall effect on this sample was measured by the method of van der pauw and studied on carrier density and mobility depending on temperature. From Hall data, the mobility was likely to be decreased by pizoelectric scattering in the temperature range 30K to 150K and by polar optical scattering in the temperature range 150K to 293K. The optical energy gaps were found to be 1.68eV for CuGaSe$_2$ single crystal thin films at room temperature. The temperature dependence of the photocurrent peak energy is well explained by the Varshni equation then the constants in the Varshni equation are given by a=9.615$\times$ 10$^{-4}$ eV/K, and $\beta$=335K. From the photocurrent spectra by illumination of polarized light of the CuGaSe$_2$ single crystal thin films. We have found that values of spin orbit coupling ΔSo and crystal field splitting ΔCr was 0.0900eV and 0.2498eV, respectively. From the PL spectra at 20K, the peaks corresponding to free bound excitons and D-A pair and a broad emission band due to SA is identified. The binding energy of the free excitons are determined to be 0.0626eV and the dissipation energy of the acceptor-bound exciton and donor-bound exciton to be 0.0352eV, 0.0932eV, respectively.

  • PDF

Synthesis and Design of Electroactive Polymers for Improving Efficiency and Thermal Stability in Organic Photovoltaics

  • Kim, Beom-Jun
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2011.05a
    • /
    • pp.11.2-11.2
    • /
    • 2011
  • Polymer based organic photovoltaics have attracted a great deal of attention due to the potential cost-effectiveness of light-weight and flexible solar cells. However, most BHJ polymer solar cells are not thermally stable as subsequent exposure to heat drives further development of the morphology towards a state of macrophase separation in the micrometer scale. Here we would like to show three different approaches for developing new electroactive polymers to improve the thermal stability of the BHJ solar cells, which is a critical problem for the commercialization of these solar cells. For one of the examples, we report a new series of functionalized polythiophene (PT-x) copolymers for use in solution processed organic photovoltaics (OPVs). PT-x copolymers were synthesized from two different monomers, where the ratio of the monomers was carefully controlled to achieve a UV photo-crosslinkable layer while leaving the ${\pi}-{\pi}$ stacking feature of conjugated polymers unchanged. The crosslinking stabilizes PT-x/PCBM blend morphology preventing the macro phase separation between two components, which lead to OPVs with remarkably enhanced thermal stability. The drastic improvement in thermal stabilities is further characterized by microscopy as well as grazing incidence X-ray scattering (GIXS). In the second part of talk, we will discuss the use of block copolymers as active materials for WOLEDs in which phosphorescent emitter isolation can be achieved. We have exploited the use of triarylamine (TPA) oxadiazole (OXA) diblock copolymers (TPA-b-OXA), which have been used as host materials due to their high triplet energy and charge-transport properties enabling a balance of holes and electrons. Organization of phosphorescent domains in TPA-b-OXA block copolymers is demonstrated to yield dual emission for white electroluminescence. Our approach minimizes energy transfer between two colored species by site isolation through morphology control, allowing higher loading concentration of red emitters with improved device performance. Furthermore, by varying the molecular weight of TPA-b-OXA and the ratio of blue to red emitters, we have investigated the effect of domain spacing on the electroluminescence spectrum and device performance.

  • PDF

Characteristics and Influence of Scattering Radiation in Cultural Heritage Radiography (문화재 방사선 조사에서 발생하는 산란 방사선의 특성과 영향)

  • Song, Jung Il;Park, Young Hwan;Yu, Ji Hye
    • Journal of Conservation Science
    • /
    • v.34 no.6
    • /
    • pp.539-548
    • /
    • 2018
  • This study was conducted to evaluate the effects of scattering radiation, which was not considered in the cultural Heritage radiography, by evaluating the relationship between the tube voltage (unit: kVp), film-floor-distance(FFD), and lead screen layout. The density (unit: D) of the test specimens and the scattered radiation increased with the tube voltage. The density of the test specimens showed an average deviation of 1.4 D; it was 0.17 D at 60 kVp, 1.54 D at 160 kVp, and 2.97 D at 220 kVp. The mean density of the scattered radiation was 0.10 D at 60 kVp, 0.40 D at 160 kVp, and 0.46 D at 220 kVp. The density tended to increase when the tube voltage ranged between 60 kVp and 160 kVp, as the FFD distance increased. However, a change in the permeation density was not observed for high voltages(160 kVp-220 kVp). Scattered radiation was observed when FFD was 50 mm, 100 mm, and 200 mm and no lead screen was used and the bottom surface was replaced with the lead screen. No scattered radiation was observed when FFD was 0 mm. The identification rate ranged from 2.08% to 2.67%, according to the FFD, for a 160 kVp tube voltage, and from 2.67% to 3.33% for a 220 kVp tube voltage.

Measurement of Comparison to Scattering Dose Space According to the Presence or Absence of Protective Clothing in the X-ray Room (X선 촬영실에서 방호복 유무에 따른 공간산란선량의 측정 비교)

  • Heo, Ye-Ji;Kim, Kyo-Tae;Cho, Chang-Hoon;Kang, Su-Man;Park, Ji-Koon;Kang, Sang-Sik;Noh, Si-Cheul;Jung, Bong-Jae
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.4
    • /
    • pp.313-320
    • /
    • 2012
  • Current medical institutions with the development of medical technology to the increased demand for health use of radiation equipment is increasing rapidly. Direct radiation from the patient receives the aim of reducing exposure as much as possible is important and the spatial dose of scattered radiation with in the space to engage in reducing healthcare physician, radiation workers and carers need to reduce indirect exposure. X-ray radiation workers and caregivers in the X-ray room to wearing of protective clothing is advised. However Radiation worker sand caregivers of patients with secondary is done, by wearing protective clothing to wear protective clothing because of the weight and discomfort have been neglected. In this study, based on the presence or absence of clothing scattered radiation from space to measure distances, depending on the horizontal and height by measuring the angle of the importance of wearing protective clothing were investigated.

Study of Tungsten Nitride Diffusion Barrier for Various Nitrogen Gas Flow Rate by Employing Nano-Mechanical Analysis (Nano-Mechanics 분석을 통한 질화 텅스텐 확산방지막의 질소 유량에 따른 연구)

  • Kwon, Ku Eun;Kim, Sung Joon;Kim, Soo In;Lee, Chang Woo
    • Journal of the Korean Vacuum Society
    • /
    • v.22 no.4
    • /
    • pp.188-192
    • /
    • 2013
  • Many studies have been conducted for preventing from diffusion between silicon wafer and metallic thin film due to a decrease of line-width and multi-layer thin film for miniaturization and high integration of semiconductor. This paper has focused on the nano-mechanical property of diffusion barrier which sample is prepared for various gas flow rate of nitrogen with tungsten (W) base from 2.5 to 10 sccm. The deposition rate, resistivity and crystallographic properties were measured by a ${\beta}$-ray back-scattering spectroscopy, 4-point probe and x-ray diffraction (XRD), respectively. We also has investigated the nano-mechanical property using the nano-indenter. As a result, the surface hardness of W-N thin film was increased rapidly from 10.07 to 15.55 GPa when the nitrogen gas flow was increased from 2.5 to 5 sccm. And the surface hardness of W-N thin film had 12.65 and 12.77 GPa at the nitrogen gas flow of 7.5 and 10 sccm respectively. These results were decreased by the comparison with the W-N thin film at nitrogen gas flow of 5 sccm. It was inferred that these severe changes were caused by the stoichiometric difference between the crystalline and amorphous state in W-N thin film. In addition, these results were caused by increased compressive stress.

Growth of $CdS_{0.67}Se_{0.33}$ single crystal by sublimation method and their photoconductive characteristics (승화법에 의한 $CdS_{0.67}Se_{0.33}$ 단결정 성장과 광전도 특성)

  • Hong, K.J.;Lee, S.Y.
    • Journal of Sensor Science and Technology
    • /
    • v.7 no.2
    • /
    • pp.131-139
    • /
    • 1998
  • $CdS_{0.67}Se_{0.33}$ single crystal was grown by vertical sublimation method of closed tube physical vapour deposition. The (0001) growth plane of oriented single crystals was confirmed from the back-ref1ection Laue patterns. From the Hall effects by van der Pauw method, the as-grown $CdS_{0.67}Se_{0.33}$ single crystals were found to be n-type semiconductors. The mobility appeared to be decreased by lattice scattering at temperature range from 150K to 293K and by impurity scattering at temperatures ranging from 30K to 150K In order to explore its applicability in photoconductive cells, we measured the ratio of photo-current to dark-current (pc/dc), maximum allowable power dissipation (MAPD), spectral response and response time respectively. The results indicated that for the samples annealed in Cu vapour the photoconductive characteristics are best. We obtained sensitivity of 0.99, the value of pc/de of $1.84{\times}10^{7}$, the MAPD of 323mW and the rise and decay time of 9.3 ms and 9.7 ms, respectively.

  • PDF

Growth and Characterization of ZnSe Thin Film for Blue Diode (청색 Diode 개발을 위한 ZnSe 박막성장과 특성에 관한 연구)

  • 박창선;홍광준
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.533-538
    • /
    • 2001
  • The ZnSe sample grown by chemical bath deposition (CBD) method were annealed in Ar gas at 450$^{\circ}C$ Using extrapolation method of X-ray diffraction pattern, it was found to have zinc blend structure whose lattice parameter a$\_$o/ was 5.6687 ${\AA}$. From Hall effect, the mobility was likely to be decreased by impurity scattering at temperature range from 10 K to 150 K and by lattice scattering at temperature range from 150 K to 29 3K. The band gap given by the transmission edge changed from 2.7005 eV at 293 K to 2.8739 eV at 10 K. Comparing photocurrent peak position with transmission edge, we could find that photocurrent peaks due to excition electrons from valence band, $\Gamma$$\_$8/ and $\Gamma$$\_$7/ to conduction band $\Gamma$$\_$6/ were observed at photocurrent spectrum. From the photocurrent spectra by illumination of polarized light on the ZnSe thin film, we have found that values of spin orbit coupling splitting Δso is 0.0981 eV. From the PL spectra at 10 K, the peaks corresponding to free bound excitons and D-A pair and a broad emission band due to SA is identified. The binding energy of the free excitons are determined to be 0.0612 eV and the dissipation energy of the donor -bound exciton and acceptor-bound exciton to be 0.0172 eV, 0.0310 eV, respectively.

  • PDF

A novel ceramic GEM used for neutron detection

  • Zhou, Jianrong;Zhou, Xiaojuan;Zhou, Jianjin;Jiang, Xingfen;Yang, Jianqing;Zhu, Lin;Yang, Wenqin;Yang, Tao;Xu, Hong;Xia, Yuanguang;Yang, Gui-an;Xie, Yuguang;Huang, Chaoqiang;Hu, Bitao;Sun, Zhijia;Chen, Yuanbo
    • Nuclear Engineering and Technology
    • /
    • v.52 no.6
    • /
    • pp.1277-1281
    • /
    • 2020
  • A novel ceramic Gas Electron Multiplier (GEM) has been developed to meet the demand of high counting rate for the neutron detection which is an alternative to 3He-based detector at China Spallation Neutron Source (CSNS). An experiment was performed to measure the neutron transmittance of ceramic-GEM and FR4-GEM at the small angle neutron scattering (SANS) instrument. The result showed the ceramic-GEM has higher transmittance and less self-scattering especially for cold neutrons. One single ceramic GEM could give a gain of 102-104 in the mixture gas of Ar and CO2 (90%:10%) and its energy resolution was about 27.7% by using 55Fe X ray of 5.9 keV. A prototype has been developed in order to investigate the performances of the ceramic GEM-based neutron detector. Several neutron beam tests, including detection efficiency, spatial resolution, two-dimensional imaging, and wavelength spectrum, were carried out at CSNS and China Mianyang Research Reactor (CMRR). The results show that the ceramic GEM-based neutron detector is a good candidate to measure the high intensity neutrons.

Preparation and Characterization of Nafion Composite Membranes Containing 1-ethyl-3-methylimidazolium Tetracyanoborate

  • Shin, Mun-Sik;Park, Jin-Soo
    • Journal of the Korean Electrochemical Society
    • /
    • v.15 no.1
    • /
    • pp.35-40
    • /
    • 2012
  • The composite membranes using Nafion as matrix and 1-ethyl-3-methylimidazolium tetracyanoborate (EMITCB) as ion-conducting medium in replacement of water were prepared and characterized. The amount of EMITCB in Nafion varied from 30 to 50wt%. The composite membranes are characterized by ion conductivity, thermogravitational analyses (TGA) and small-angle X-ray scattering (SAXS). The composite membranes containing EMITCB of 40wt% showed the maximum ionic conductivity which was ~0.0146 S $cm^{-1}$ at 423.15 K. It is inferred that the decrease in ionic conductivity of all the composite membranes might be due to the decomposition of a tetracyanoboric acid formed in the composite membranes. The results of SAXS indicated that the ionic clusters to conduct proton in the composite membranes were successfully formed. In accordance with the results of ionic conductivity as a function of a reciprocal temperature, SAXS showed a proportional decrease in scattering maximum $q_{max}$ as the amount of EMITCB increases in the composite membranes, which results in the increase in ionomer cluster size. The TGA showed no significant decomposition of the ionic liquid as well as the composite membranes in the range of operating temperature ($120-150^{\circ}C$) of high temperature proton exchange membrane fuel cells (HTPEMFC). As a result, EMITCB is able to play an important role in transferring proton in the composite membranes at elevated temperatures with no external humidification for proton exchange membrane fuel cells.

Effectiveness Evaluation of Scanogram Using Longbone Detector (Longbone 검출기를 이용한 Scanogram의 유효성 평가)

  • Jang, Su-han;Heo, Ji-eun
    • Journal of radiological science and technology
    • /
    • v.43 no.4
    • /
    • pp.235-242
    • /
    • 2020
  • Scanogram is that combine several practical images into one image to observation. So it is an important consideration in many clinical situation such as iliac measurement, leg alignment measurement and Scoliosis. Currently, scanogram examinations are mainly conducted for children and elderly patients. In this study, in order to apply the longbone detector to children or elderly patients who are difficult to cooperate with, we compared the longbone detector from D equipment with the G equipment discovery 656 Puls equipment in reproducibility of images, distribution of irradiation dose, scattering dose, irradiation time and image acquisition time. D equipment took more than twice as much time as G equipment. The scattered dose generated about 50% more G equipment than D equipment. In the whole spine scanogram and the measurement length of the lower leg, D equipment was also measured longer than G equipment. However, both methods did not show much difference from the CT scanogram, so there was no problem in measurement. The height of the thyroid radiation dose of G equipment was produced more radiation than D equipment. However, the longbone detector deviated from the x-ray center line relative to the tube rotation method, and was measured lower by the directionality of the measuring instrument, so that the error could not be corrected. In the conclusion of study, using the longbone detector is excellent for applying to children or elderly patients to reduce scattering dose. However, using CR may be useful to normal patients. Because, the image quality may deteriorate due to an imbalance of dose difference in thickness depending on the body part. So, it is useful to using a compensation filter or tube rotation method when we take a whole spine scanogram.