• Title/Summary/Keyword: X-Ray computed tomography

Search Result 701, Processing Time 0.027 seconds

Evaluation of Target Position's Accuracy in 2D-3D Matching using Rando Phantom (인체팬톰을 이용한 2D-3D 정합시 타켓위치의 정확성 평가)

  • Jang, Eun-Sung;Kang, Soo-Man;Lee, Chul-Soo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.21 no.1
    • /
    • pp.33-39
    • /
    • 2009
  • Purpose: The aim of this study is to compare patient's body posture and its position at the time of simulation with one at the treatment room using On-board Imaging (OBI) and CT (CBCT). The detected offsets are compared with position errors of Rando Phantom that are practically applied. After that, Rando Phantom's position is selected by moving couch based on detected deviations. In addition, the errors between real measured values of Rando Phantom position and theoretical ones is compared. And we will evaluate target position's accuracy of KV X-ray imaging's 2D and CBCT's 3D one. Materials and Methods: Using the Rando Phantom (Alderson Research Laboratories Inc. Stanford. CT, USA) which simulated human body's internal structure, we will set up Rando Phantom on the treatment couch after implementing simulation and RTP according to the same ways as the real radioactive treatment. We tested Rando Phantom that are assumed to have accurate position with different 3 methods. We measured setup errors on the axis of X, Y and Z, and got mean standard deviation errors by repeating tests 10 times on each tests. Results: The difference between mean detection error and standard deviation are as follows; lateral 0.4+/-0.3 mm, longitudinal 0.6+/-0.5 mm, vertical 0.4+/-0.2 mm which all within 0~10 mm. The couch shift variable after positioning that are comparable to residual errors are 0.3+/-0.1, 0.5+/-0.1, and 0.3+/-0.1 mm. The mean detection errors by longitudinal shift between 20~40 mm are 0.4+/-0.3 in lateral, 0.6+/-0.5 in longitudinal, 0.5+/-0.3 in vertical direction. The detection errors are all within range of 0.3~0.5 mm. Residual errors are within 0.2~0.5 mm. Each values are mean values based on 3 tests. Conclusion: Phantom is based on treatment couch shift and error within the average 5mm can be gained by the diminution detected by image registration based on OBI and CBCT. Therefore, the selection of target position which depends on OBI and CBCT could be considered as useful.

  • PDF

Analysis of Relativity Between Invasiveness on Chest of Tomographic Finding and Histopathologic Invasiveness (종격동 종양의 전산화 단층촬영(CT)소견, 수술소견 및 병리조직학적 침윤도 사이의 상관성 분석)

  • 김용희;이현우
    • Journal of Chest Surgery
    • /
    • v.30 no.8
    • /
    • pp.780-785
    • /
    • 1997
  • Mediastinal tumor had been fascinated by its location on heart, great vessels, esophagus, and nervous tissue, its convenience of surgical treatment and superiority of its operative result. Between January 1989 and June 1995, eighty-seven patients with mediastinal tumor which were treated surgically in the Department of Thoracic and Cardiovascular Surgery, Asan Medical Center, School of Medicine, University of Ulsan. To provide the appropriate surgical management of mediastinal tumor, the demographic data, diagnostic evaluation, clinical presentation, location, size, operative finding and histopathologic distribution were reviewed and we analyzed relativity between invasiveness in chest computed tomographic finding or invasiveness on operative finding and histopathologic invasiveness. The anterosuperior mediastinum was the most commonly involved site of a mediastinal tumor(57%), followed by the posterior mediastinum(35%) and middle mediastinum(8%). The most frequently encountered tumors were thymic neoplasia(31%), followed by primary cyst(22%), neurogenic tumor(22%) and teratoma(10%) in decreasing order of frequency. Histopathologically invasive tumors were present in 17 patients(20%) and its site included anterosuperior mediastinum(16%) and posterior mediastinum(4%). All patients in this study underwent chest CT. In chest CT's finding, 15 patients(17%) showed invasiveness. A total excision of the tumor was performed 80 patients(92%), subtotal excision 6 patients(7%) and biopsy only 1 patient(2%). In operative finding, 14 patients(16%) were suspected invasiveness. The mean size of the tumor was 6.0$\pm$ 3.2cm. In anterosuperior mediastinum, the mean size was 6.2$\pm$3.1cm, in middle mediastinum, it was 3.9$\pm$1.1cm, in posterior mediastinum, it was 5.8$\pm$2.6cm. In malignant tumors, the mean size was 7.3$\pm$4.6cm, in benign tumor, it was 5.5$\pm$2.6cm(P<0.05). Relativity between histopathological invasiveness(17 patients) and invasiveness in chest CT's finding(15 patients) included sensitivity 35%, specificity 87% and predictability 35%, relativity between histopathological invasiveness(17 patients) and invasiveness on operative finding included sensitivity 52%, specificity 93% and predictability 64%. In conclusion, since it was proved that the compatibility of preoperative chest CT findings or operative findings and histopathological invasiveness is quite low, it is considered that wide excision of the mediastinal tumor except cystic lesion including adjacent tissues would yield better postoperative results.

  • PDF

Analysis of Bacterial Contamination on Surface of General Radiography Equipment and CT Equipment in Emergency Room of Radiology (영상의학과 응급실내의 일반촬영장비와 전산화단층촬영장비 표면에서의 세균 오염에 관한 분석)

  • Hong, Dong-Hee;Kim, Hyeong-Gyun
    • Journal of radiological science and technology
    • /
    • v.39 no.3
    • /
    • pp.421-427
    • /
    • 2016
  • We aim to offer basic materials about infection management through conducting bacterial contamination test about general radiography equipment and CT equipment installed in ER of three general hospitals with 100 sickbeds or more located in Gyeongsangbuk-do Province, and suggest management plan. It had been conducted from 1st December 2015 to 31st December, and objects were general radiography equipment and CT equipment of emergency room located in Gyeongsangbuk-do Province. For general radiography equipment, sources were collected from 4 places such as upper side of control box which employees use most, upper side of exposure button, whole upper side of table which is touching part of patient's skin, upper side of stand bucky's grid, and where patients put their jaws on. For CT equipment, sources were collected from 3 places such as upper side of control box which radiography room employees use most, X-ray exposure button, whole upper side of table which is touching part of patient's skin, and gantry inner. Surface contamination strain found at general radiography equipment in emergency room of radiology are Providencia stuartii(25%), Stenotrophomonas maltophilia(18%), Enterobacter cloacae(8%), Pseudomonas species(8%), Staphylococcus epidermidis(8%), Gram negative bacilli(8%), and ungrown bacteria at incubator after 48 hours of incubation (67%) which is the biggest. Most bacteria were found at upper side of stand bucky-grid and stand bucky of radiology's general radiography equipment, and most sources of CT equipment were focused at patient table, which means it is contaminated by patients who have various diseases, and patients who have strains with decreased immunity may get severe diseases. Thus infection prevention should be made through 70% alcohol disinfection at both before test and after test.

Calculation of Renal Depth by Conjugate-View Method Using Dual-head Gamma Camera (이중 헤드 감마 카메라를 이용한 Conjugate-View 계수법에 의한 신장 깊이 도출)

  • Kim, Hyun-Mi;Suh, Tae-Suk;Choe, Bo-Young;Chung, Yong-An;Kim, Sung-Hoon;Chung, Soo-Kyo;Lee, Hyoung-Koo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.35 no.6
    • /
    • pp.378-388
    • /
    • 2001
  • Purpose: In this study, we developed a new method for the determination of renal depth with anterior and posterior renal scintigrams in a dual-head gamma camera, considering the attenuation factor $e^{-{\mu}x}$ of the conjugate-view method. Material and Method: We developed abdomen and kidney phantoms to perform experiments using Technetium-99m dimercaptosuccinic acid ($^{99m}Tc$-DMSA). The phantom images were obtained by dual-head gamma camera equipped with low-energy, high-resolution, parallel-hole collimators (ICONf, Siemens). The equation was derived from the linear integration of omission ${\gamma}$-ray considering attenuation from the posterior abdomen to the anterior abdomen phantom surface. The program for measurement was developed by Microsoft Visual C++ 6.0. Results : Renal depths of the phantoms were derived from the derived equations and compared with the exact geometrical values. Differences between the measured and the calculated values were the range of 0.1 to 0.7 cm ($0.029{\pm}0.15cm,\;mean{\pm}S.D.$). Conclusion: The present study showed that the use of the derived equations for renal depth measurements, combined with quantitative planar imaging using dual-head gamma camera, could provide more accurate results for individual variation than the conventional method.

  • PDF

Effect of Noise on Density Differences of Tissue in Computed Tomography (컴퓨터 단층촬영의 조직간 밀도차이에 대한 노이즈 영향)

  • Yang, Won Seok;Son, Jung Min;Chon, Kwon Su
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.3
    • /
    • pp.403-407
    • /
    • 2018
  • Currently, the highest cancer death rate in Korea is lung cancer, which is a typical cancer that is difficult to detect early. Low-dose chest CT is being used for early detection, which has a greater lung cancer diagnosis rate of about three times than regular chest x-ray images. However, low-dose chest CT not only significantly reduces image resolution but also has a weak signal and is sensitive to noise. Also, air filled lungs are low-density organs and the presence of noise can significantly affect early diagnosis of cancer. This study used Visual C++ to set a circle inside a large circle with a density of 2.0, with a density of 1.0, which is the density of water, in which five small circle of mathematics have different densities. Gaussian noise was generated by 1%, 2%, 3%, and 4% respectively to determine the effect of noise on the mean value, the standard deviation value, and the relative noise ratio(SNR). In areas where the density difference between the large and small circles was greatest in the event of 1 % noise, the SNR in the area with the greatest variation in noise was 4.669, and in areas with the lowest density difference, the SNR was 1.183. In addition, the SNR values can be seen to be high if the same results are obtained for both positive and negative densities. Quality was also clearly visible when the density difference was large, and if the noise level was increased, the SNR was reduced to significantly affect the noise. Low-density organs or organs in areas of similar density to cancers, will have significant noise effects, and the effects of density differences on the probability of noise will affect diagnosis.

Clinical Analysis of Bronchogenic Cyst (기관지성 낭종의 임상적 고찰)

  • 안재범;정성철;김우식;신용철;유환국;이정호;김병열;김인섭
    • Journal of Chest Surgery
    • /
    • v.37 no.7
    • /
    • pp.585-590
    • /
    • 2004
  • Bronchogenic cyst is a rare and benign disease. Because of its complication or associated disease, Bronchogenic cyst requires surgical treatment. Recently, with the development of diagnostic methods, its incidence has increased. So we reviewed our results from the past 30 years. Material and Method: We reviewed 27 cases surgically treated from March 1971 to March 2003. This investigation is designed to illustrate the peak age incidence, sex ratio, symptoms, anatomic location, radiologic imagings, associated diseases, operative methods, postoperative pathologic findings and postoperative complications. Result: The peak age incidence laid in the 1st to 3rd decade and the ratio of male and female was 1 : 1.5. The most common complaints were cough and dyspnea, but some had hemoptysis. There were 22 cases (81%) of Intrapulmonary bronchogenic cysts and 5 cases(19%) of mediastinal bronchogenic cysts. Thirteen cases (48.1%) showed cystic lesion in simple chest X-ray. Ten cases showed cystic lesion among 13 cases that had taken computed tomography. We found associated disease in 15cases (56%). The inflammatory diseases from infection were many in intrapulmonary bronchogenic cysts and especially, one case showed carcinosarcoma. Mitral regurgitation and Bronchial obstruction could be seen in mediastinal bronchogenic cysts. The 13 cases (48%) were managed by lobectomy, and cystectomy, pneumonectomy, and segemental resection were done in 7 cases (26%), 4 cases (15%), 3 cases (11%) respectively. Cystic contents were mucus in 9 cases, pus in 9 cases, blood in 2 cases, and carcinosarcoma in 1 case. Bronchotracheal communications were in 13 cases (48%). Five cases showed Postoperative complications, which were pneumothorax, empyema, bleeding. Postoperative death could not be found. Conclusion: Almost all patients had clinical symptoms. Severe complications could be associated with bronchogenic cysts. Recently, With the development of diagnostic methods, preoperatively accurate diagnosis is possible; therefore, invasive study has decreased. Bronchogenic cyst is a benign disease. However, because of its clinical symptoms, complications, and possibility of malignant change, immediate surgical treatment is needed.

Analysis of Set-up Errors during CT-scan, Simulation, and Treatment Process in Breast Cancer Patients (유방암 환자의 모의치료, CT 스캔 및 치료 과정에서 발생되는 준비 오차 분석)

  • Lee, Re-Na
    • Radiation Oncology Journal
    • /
    • v.23 no.3
    • /
    • pp.169-175
    • /
    • 2005
  • Purpose: Although computed tomography (CT) simulators are commonly used in radiation therapy department, many Institution still use conventional CT for treatments. In this study the setup errors that occur during simulation, CT scan (diagnostic CT scanner), and treatment were evaluated for the twenty one breast cancer patients. Materials and Methods: Errors were determined by calculating the differences in isocenter location, SSD, CLD, and locations of surgical clips implanted during surgery. The anatomic structures on simulation film and DRR image were compared to determine the movement of isocenter between simulation and CT scan. The isocetner point determined from the radio-opaque wires placed on patient's surface during CT scan was moved to new position if there was anatomic mismatch between the two images Results: In 7/21 patients, anatomic structures on DRR Image were different from the simulation Image thus new isocenter points were placed for treatment planning. The standard deviations of the diagnostic CT setup errors relative to the simulator setup in lateral, longitudinal, and anterior-posterior directions were 2.3, 1.6, and 1.6 mm, respectively. The average variation and standard deviation of SSD from AP field were 1.9 mm and 2.3 mm and from tangential fields were 2.8 mm and 3.7 mm. The variation of the CLD for the 21 patients ranged from 0 to 6 mm between simulation and DRR and 0 to 5 mm between simulation and treatment. The group systematic errors analyzed based on clip locations were 1.7 mm in lateral direction, 2.1 mm in AP direction, and 1.7 mm in SI direction. Conclusion: These results represent that there was no significant differences when SSD, CLD, clips' locations and isocenter locations were considered. Therefore, it is concluded that when a diagnostic CT scanner is used to acquire an image, the set-up variation is acceptable compared to using CT simulator for the treatment of breast cancer. However, the patient has to be positioned with care during CT scan in order to reduce the setup error between simulation and CT scan.

CT Measurement of Diameter and Dimension of the Trachea in Normal Korean Adults (흥부 전산화단층촬영을 이용한 한국성인의 기관내경과 단면적의 측정)

  • Han, Jae-Youl;Kim, Kwang-Ho;Lee, Gun;Kim, Hyung-Jin;Cho, Soon-Koo;Sun, Kyung
    • Journal of Chest Surgery
    • /
    • v.34 no.7
    • /
    • pp.534-538
    • /
    • 2001
  • Background: Knowledge of size and morphology of the normal trachea is important for airway management and tracheal reconstruction. Conventional radiography is a simple method used to measure the tracheal diameter, but it is not accurate because of the artifacts related to image magnification and overlapping by the shoulder. The purpose of this study was to provide the normal values of the tracheal size and anatomy in Korean adults using Computerized Topography. Material and Method: There were 43 men and 34 women included in this study. They were divided into three age groups(group 1, 20-39 years ; group 2, 40-59 yeas , groups 3, $\geq$60 years). The anteroposterior and transverse diameters and cross - sectional areas of the trachea were measured at the level of the thoracic inlet(Level 1) and the aortic arch(Level 2). These values obtained at each level were compared between age groups and sexes. Result: In 43 men, the anteroposterior / transverse diameters(mean SD in millimeters) of the trachea at levels 1 and 2 were 19.95$\pm$2.99 / 17.72$\pm$2.13 and 19.77$\pm$2.57 / 18.02$\pm$2.19, respectively. In 34 women, those values at levels 1 and 2 were 15.56$\pm$2.12 / 14.18$\pm$2.07 and 15.35$\pm$1.82 / 15.00$\pm$1.60, respectively. At both levels, the anteroposterior and transverse diameters were significantly greater in men than in women (p<0.05). The cross-sectional area of the trachea at levels 1 and 2 were 279.14$\pm$61.37 / 281.93$\pm$63.97 $\textrm{mm}^2$ in men and 173.29$\pm$35.81 / 181.88$\pm$34.74 in women, respectively. They also showed significantly greater values in men than in women(P<0.05). There was no significant difference in diameters and cross-sectional areas of the trachea between age groups. Conclusion: There are significant differences in the internal diameter and cross- sectional area of the trachea between men and women in normal Korean adults, while the age difference was insignificant. We believed CT is a relatively accurate and safe way to measure the internal diameter and cross-sectional areas of the trachea.

  • PDF

The Characteristics of Eosinophilc Lung Diseases Cause by Toxocara Canis Larval Infestation (개회충 유충 감염에서 발생되는 호산구성 폐질환의 특성)

  • Kim, Yu Jin;Kyung, Sun Young;An, Chang Hyeok;Lim, Young Hee;Park, Jung Woong;Jeong, Seong Hwan;Lee, Sang Pyo;Choi, Dong Chull;Jeong, Young Bae;Kang, Shin Yong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.62 no.1
    • /
    • pp.19-26
    • /
    • 2007
  • Background: Toxocariasis is a common cause of eosinophilia and eosinophilic lung disease in Korea. We analyzed the characteristics of eosinophilic lung disease in toxocariasis. Method: One hundred and forty one patients with eosinophilia caused by a toxocara larval infection were evaluated from September 1, 2001 through March 30, 2006. The plain chest x-ray, chest CT(computed tomography), and bronchoalveolar larvage(BAL) were examined. A diagnosis of toxocariasis was made by ELISA using that secretory-excretory antigen from the T. canis larvae. Results: Toxocarial eosinophilic lung diseases was diagnosed in 32 out of 141 patients. Ground glass attenuation was the main feature on the CT scans in 23 out of 141 patients (71.9%). Thirteen patients (40.6%) had a random in zonal distribution on CT. Pleural effusion was observed in 9 patients (28.1%). Twenty eight patients (87.5%) complained of respiratory symptoms. Eleven patients (34.4%) had gastrointestinal symptoms and 12 patients (37.5%) had liver infiltration. Conclusions: The most common findings of the chest CT in patients with toxocariasis was a randomly distributed ground grass attenuation. A toxocara infection should be considered in a differential diagnosis of patients who exhibit pulmonary infiltration with eosinophilia in Korea.

Re-conservation of the Iron Sword with Ring Pommel with Three-Pointed Leaf Decoration Excavated from Tomb No. 55 at the Dalseong Ancient Tomb Complex in Daegu and a Study of Its Production Method (대구 달성 55호분 출토 삼엽문이자태도의 재보존처리와 제작 기법 연구)

  • Lee, Huisung;Huh, Ilkwon;Ro, Jihyun;Park, Seungwon
    • Conservation Science in Museum
    • /
    • v.24
    • /
    • pp.1-16
    • /
    • 2020
  • This paper presents the process of re-conservation and the results of research on the production method of the Iron Sword with Ring Pommel with Three-Pointed Leaf Decoration, one of the excavation findings from Tomb No. 55 in the Dalseong Ancient Tomb Complex in Daegu. This iron sword is a double weapon with two large swords housed within a single sheath. Four smaller swords are attached to the surface of the sheath, two on the upper portion and the other two below. It is the only such two-in-one weapon excavated intact thus far from an ancient Korean tomb. The records show that it underwent conservation treatment twice in the past. In this study, it was subjected to conservation treatment again to replace the stiffener in some cracking areas, and its material, composition, and production method were analyzed by CT, XRF analysis, and stereoscopic microscopy. The sword is mainly made of copper, but the golden component contains both gold and mercury, which suggests that the copper was plated in gold using mercury amalgamation. The examination of the production methods indicates that it was intended more to demonstrate the authority of its owner rather than to serve any practical use. The two upper small swords on the sheath were made in the same manner as the main swords, and the two small lower swords were cut from a single metal sheet. The sheath was made by cutting two metal sheets. Supports were used to attach the two small swords to the upper portion of the sheath, while the lower portion of the sheath was slit to allow the other two small swords to be inserted into it. The ring pommels of the main swords have a three-pointed leaf decoration. As for the other designs, the handle of the main sword features a series of semicircles, the decorative bands on the sheath have waves in dots, and the fish tail of the sheath shows diagonal lines of dots.