• Title/Summary/Keyword: X-Ray CT

Search Result 949, Processing Time 0.025 seconds

Development and Performance Evaluation of an Ultra-Compact CT with Auto Calibration of Detector Center Axis (검출기 중심축을 자동 보정하는 초소형 CT 개발 및 성능평가)

  • Byeong-Woo Kwak;Keun-Ho Rew
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.5
    • /
    • pp.651-662
    • /
    • 2023
  • In this study, we designed and fabricated an ultra-compact CT that automatically calibrates the detector's center axis and verified its performance. The three-dimensional reconstruction performance was evaluated using 3D CAD data and X-ray data acquired by manually calibrating the center axis of the CT detector. The results showed that tilting the center axis by more than 0.25° causes circle break phenomenon, which rapidly degrades the quality of the 3D reconstructed image. By applying the automatic calibration device of a detector center axis, the 3D reconstruction performance was enhanced by calibrating the detector center axis to match the specimen rotation axis.

Analysis of 3D Geometry and Compressive Behavior of Aluminum Open Cell Foam Using X-ray Micro CT (마이크로 X-ray CT를 활용한 알루미늄 개방형 폼의 형상 및 압축 거동 분석)

  • Kim, Y.I.;Kim, J.H.;Lee, J.K.;Kim, D.
    • Transactions of Materials Processing
    • /
    • v.20 no.7
    • /
    • pp.518-523
    • /
    • 2011
  • The three dimensional geometries of an aluminum open cell foam before and after uniaxial compressive loading were investigated using the X-ray micro CT(computed tomography). Aluminum 6101-T6 open cell foams of 10, 20, 40 ppi (pore per inch) were considered in this work. After the serial sectioning CT images of aluminum foams were obtained from non-destructive X-ray images, the exact 3D structure were reproduced and visualized with commercial image processing program. The relative density ratio was around the 7.0 to 9.0 range, the unit cells showed anisotropic shapes having the different dimensional ratios of 1.1 to 1.3 between the rise and the transverse directions. The yield stress increased with the relative density ratio and the volumetric strain increased proportionally with compressive strain. The plateau stress in the compressive stress-strain curve was caused by the buckling of ligaments.

Development of Portable X-ray CT System II - CT Image Reconstruction of Wood using Density Distribution - (현장 적용이 가능한 X선 CT 시스템 개발 II- 밀도분포를 이용한 목재의 CT영상 구성 -)

  • Kim, Kwang-Mo;Lee, Sang-Joon;Lee, Jun-Jae
    • Journal of the Korean Wood Science and Technology
    • /
    • v.34 no.1
    • /
    • pp.23-31
    • /
    • 2006
  • X-ray transit materials with straight path and the its intensity is proportional to the density of materials. Therefore, X-ray has been extensively used as a nondestructive evaluation (NDE) method in various fields. This study was carried out for development of a portable X-ray CT (computed-tomography) system to detect deteriorations of wood members in buildings. Based on the results of our previous study, a procedure of CT image reconstruction was established In order to verify the applicability of developed system, CT images of three wood disks were reconstructed by newly developed procedure and compared with the prototypes. From the results of this study, it was shown that the newly developed system could be used not only to determine the shape, size, and position of defects, but also to find the density distribution in cross section of wood structure members. The density distribution may be utilized to clarify the reason of wood deterioration and to provide the preventive method on how to treat or repair wood buildings. Because it was initial stage of system development, there were some limitations concerned with measuring equipment and image reconstruction algorithm. Especially, measuring time including equipment setup time was longer and measuring accuracy was lower than we expected. Therefore, we planned some additional studies on improvement of equipment and algorithm to enhance the capability of X-ray CT system.

Quantification of 3D Pore Structure in Glass Bead Using Micro X-ray CT (Micro X-ray CT를 이용한 글라스 비드의 3차원 간극 구조 정량화)

  • Jung, Yeon-Jong;Yun, Tae-Sup
    • Journal of the Korean Geotechnical Society
    • /
    • v.27 no.11
    • /
    • pp.83-92
    • /
    • 2011
  • The random and heterogeneous pore structure is a significant factor that dominates physical and mechanical behaviors of soils such as fluid flow and geomechanical responses driven by loading. The characterization method using non-destructive testing such as micro X-ray CT technique which has a high resolution with micrometer unit allows to observe internal structure of soils. However, the application has been limited to qualitatively observe 2D and 3D CT images and to obtain the void ratio at macro-scale although the CT images contain enormous information of materials of interests. In this study, we constructed the 3D particle and pore structures based on sequentially taken 2D images of glass beads and quantitatively defined complex pore structure with void cell and void channel. This approach was enabled by implementing image processing techniques that include coordinate transformation, binarization, Delaunay Triangulation, and Euclidean Distance Transform. It was confirmed that the suggested algorithm allows to quantitatively evaluate the distribution of void cells and their connectivity of heterogeneous pore structures for glass beads.

Microfocus X-ray CT Analysis of Shrinking Direction in Resin Composite.

  • Inai, N.;Katahira, N.;Hashimoto, K.;Tagami, J.;Hirakimoto, A.;Marshall, S.J.;Marshall. G.W.
    • Proceedings of the KACD Conference
    • /
    • 2001.11a
    • /
    • pp.559.1-559
    • /
    • 2001
  • The aim of the study was to determine the direction and the rate of polymerization shrinkage of light-cured resin composite. Materials and Methods: A microfocus x-ray CT(computed tomography) instrument (SMX-255CT, Shimadzu Co., Kyoto, Japan) was used to analyze and characterize the pre-and post-gel phases. A microfocus x-ray tube was used to enable a focus dimension of 4 microns.(omitted)

  • PDF

Development of PC based High Voltage Generator for Dental CT (PC기반 치과 CT용 고전압 펄스 발생장치 개발)

  • Kim, Hack-Seong;Oh, Jun-Yong;Song, Sang-Hoon;Won, Choong-Yeon
    • Proceedings of the KIPE Conference
    • /
    • 2008.06a
    • /
    • pp.580-582
    • /
    • 2008
  • The object of this paper is develope the PC based controlled high voltage power supply and studies 1.2kW(120kV, 10mA) pulse power X-ray generator possible to adapt fluoroscopy of Dental CT X-ray generator and industrial X-ray pulse power equipment. The developed pulse power X-ray generator consisted of mono-block tank include X-ray tube and high voltage X-ray power supply circuit and high voltage control unit with RS232C/422 communication port. The PC control program of pulse power X-ray generator uses LabVIEW, and the size of high voltage transformer and high voltage generator is minimized by high voltage high frequency inverter has 100kHz switching frequency. Also this paper shows result of X-ray tube voltage and tube current correspond to variable load.

  • PDF

Development of Portable X-ray CT System I - Evaluation of Wood Density using X-ray Radiography - (현장 적용이 가능한 X선 CT 시스템 개발 I - X선 촬영법을 이용한 목재의 밀도 측정 -)

  • Kim, Kwang-Mo;Lee, Sang-Joon;Lee, Jun-Jae
    • Journal of the Korean Wood Science and Technology
    • /
    • v.34 no.1
    • /
    • pp.15-22
    • /
    • 2006
  • ln order to manage efficiently many ancient wooden buildings, which have been preserved as cultural properties in Korea, the internal state of wood members should be evaluated exactly and periodically by a NDE (non-destructive evaluation) method. A research project was planned to develop an X-ray CT (computed tomography) system as a NDE method for wood, which could be easily applied in field. This paper includes the first part of this project. First of all, to establish a measuring procedure of wood density using X-ray radiography, the correlation between X-ray intensity and the film brightness was evaluated. Also, initial X-ray intensity was quantified with various radiate conditions controlled by the tube voltage and tube current. And then, the effects of density, annual ring angle, and thickness on the mass attenuation coefficient of wood were examined. Finally, Beer's law was modified with the above results and adopted to calculate the density of wood. As a result of this study, the measuring procedure of wood density was established using a portable soft X-ray device and this procedure was verified with some small wood specimens. This results will he used valuably for the following researches to develop a portable X-ray CT system.

Development of X-ray Micro Computed Tomography and Applications (미세 X선 단층촬영 기법의 개발과 적용)

  • Kim, Seung-Gon;Lim, Jae-Hong;Kim, Bo-Heum;Lee, Eui-Jae;Lee, Sang-Joon
    • Journal of the Korean Society of Visualization
    • /
    • v.8 no.2
    • /
    • pp.45-50
    • /
    • 2010
  • The objective of this study is to elucidate the feasibility of synchrotron X-ray micro CT as a non-destructive imaging method to visualize the three-dimensional morphological structures of biological and non-biological samples. The experiments were conducted in 7B2 X-ray micro CT beamline in Pohang Accelerate Laboratory (PAL). A rotational 3-axis stage was specially designed for $0^{\circ}-180^{\circ}$ scanning of test samples. Preliminary tests were performed for opaque samples including a mosquito head, a plant seed and gas diffusion layer (GDL) of polymer electrolyte fuel cell to verify the feasibility of the X-ray micro CT. It visualized clearly the internal structure of all the test samples, supporting its usefulness.

Metal Area Segmentation in X-ray CT Images Using the RNA (Relevant Neighbor Ar ea) Principle

  • Kim, Youngshin;Kwon, Hyukjoon;Kim, Joongkyu;Yi, Juneho
    • Journal of Korea Multimedia Society
    • /
    • v.15 no.12
    • /
    • pp.1442-1448
    • /
    • 2012
  • The problem of Metal Area Segmentation (MAS) in X-ray CT images is a very hard task because of metal artifacts. This research features a practical yet effective method for MAS in X-ray CT images that exploits both projection image and reconstructed image spaces. We employ the Relevant Neighbor Area (RNA) idea [1] originally developed for projection image inpainting in order to create a novel feature in the projection image space that distinctively represents metal and near-metal pixels with opposite signs. In the reconstructed result of the feature image, application of a simple thresholding technique provides accurate segmentation of metal areas due to nice separation of near-metal areas from metal areas in its histogram.

A Study on the Parallel Processing Architecture for the Real Time Image Reconstruction of X-ray CT (X-ray CT의 실시간 영상재구성을 위한 병렬처리 구조에 관한 연구)

  • Jin, Seung-Oh;Heo, Chang-Won;Huh, Young
    • Proceedings of the KIEE Conference
    • /
    • 1999.07g
    • /
    • pp.3153-3155
    • /
    • 1999
  • 최근 수년간 의료영상분야는 국내외적으로 급격한 발전을 거듭하고 있다. 특히 자기공명영상장치 (Magnetic Resonance Imaging), X-ray CT(Computed Tomography)와 단층촬영장치는 인체내부를 비침습적(non-invasive)으로 영상화함으로써 해부학적인 질병진단에 많은 장점을 가지고 있다. 이와같은 단층영상 재구성에는 역매트릭스법(matrix inversion). 반복재구성법(interative method), 역투영 법(back-projection), 2차원 Fourier 변환법(2D FFT), 중첩재구성법(Filtered back-projection) 등의 다양한 알고리즘을 사용하고 있다. 본 연구에서는 X-ray CT에서의 단층영상재구성 기법 중 널리 사용되고 있는 Filtered Back Projection 기법의 연산순서도와 연산량을 분석하고 이를 시뮬레이션을 통하여 확인하고 실시간 영상재구성을 위하여 범용 Digital Signal Processor의 병렬처리시스템 구성에 기반된 최적 Architecture를 선정하고자 한다.

  • PDF