• 제목/요약/키워드: X-RD

검색결과 273건 처리시간 0.028초

두폭, 체중 및 체장에 의한 뽕나무하늘소 유충의 성장율 비교 (The Estimate of Larval Growth of Mulberry Longicorn Beetle, Apriona germari Hope on the basis of the Larval Head Capsule Width, Larval Weight and Length)

  • 윤형주;마영일
    • 한국잠사곤충학회지
    • /
    • 제39권2호
    • /
    • pp.174-179
    • /
    • 1997
  • The larval head capsule width, larval weight and length of mulberry longicorn beetle, Apriona germari Hope were measured when the larvae were exuviated in artificial diet rearing. The larval head capsule width from the 1st to the 12th instar was ranged from 0.12 to 0.69 cm, and growth ratio of each instar was significantly high between the 1st and the 2nd instars. The fitness to Dyar's law for the larval head capsule width was 87.6%. When the logarithum of the larval head capsule width is plotted against the number of instars, the calculated regression line was LogY=0.12086+0.06998X and Dyar's constant was 1.18. The larval weight was increased with larval developmental stages, and the coefficient of variation of larval weight was apparently high. But the calculated regression line was LogY=-0.91592+0.25959X and Dyar's constant was 1.25. The growth ration of the larval length was clearly high between the 2nd and the 3rd instars, and that of larvae from the 4th instar was decreased. The calculated regression line was LogY=-0.16932+0.09841X and Dyar's constant was 1.25. In conclusion, our results suggested that the larvae growth of mulberry longicorn beetle appeared to be highly related in the larval head capsule width, larval weight and length.

  • PDF

GMR센서 배열을 이용한 자석팁의 2D 위치 추정 (2D Location Estimation of a Magnetized Tip Using Arrayed GMR Sensors)

  • 이승철;김정관;안중환;김화영
    • 센서학회지
    • /
    • 제28권6호
    • /
    • pp.395-401
    • /
    • 2019
  • This paper proposes a method for estimating the location of a magnetized tip that is inside a non-transparent space or body by using arrayed giant magnetoresistance (GMR) sensors. In general, an object located in such an opaque space can be detected using X-rays, magnetic fields, ultra-sonic sensors, etc., depending on its characteristics. X-ray is mostly used for medical purposes but frequent exposure to it could cause harm to patients as well as doctors. In this study, how well a GMR sensor is applicable instead of an X-ray is investigated. The sensor's voltage output is experimentally fitted to distance with a relationship of 3rd degree polynomial. To detect a small magnetized tip with 900 Oe inside a human body, a 2×2 arrayed GMR sensor and a location estimation algorithm based on information acquired from four sensors is developed. Evaluation tests show that the suggested method is applicable to limited cases with a distance less than 33-55 mm, and the location of a magnet tip is estimated relatively well with an error less than 1.5 mm.

용접열사이클 재현에 의한 SS400강 및 STS304강의 특성 평가 - 제3보: 잔류응력과 초음파 파라미터 (Evaluation of Characteristic for SS400 and STS304 Steel by Weld Thermal Cycle Simulation - 3rd Report: Residual Stress and Ultrasonic Parameter)

  • 안석환;최문오;정정환;김성광;남기우
    • 한국해양공학회지
    • /
    • 제22권6호
    • /
    • pp.27-34
    • /
    • 2008
  • The temperature distribution in the weldment is not uniform because a weldment is locally heated. Thermal plastic deformation results from the local expansion and shrinkage by the heating and cooling of metal. Therefore, residual stresses and distortion occur in the weldment. In this study, we had conducted on the weld thermal cycle simulation that is supposed as the HAZ on SS400 steel and STS304 steel. The residual stresses that were obtained from the drawing and the weld thermal cycle simulation were estimated by X-ray diffraction. We also carried out ultrasonic test for the weld thermal cycle simulated specimens, and then conducted on nondestructive evaluation by the ultrasonic parameters obtained ultrasonic test. From the results, residual stresses of weld thermal cycle simulated specimens after the residual stress removal heat treatment are lower than that of the drawing.

장성탄광(長省炭鑛)의 갱내출수(坑內出水)가 생산량(生産量)에 미치는 영향(影響)에 관(關)한 연구(硏究) (A Study on the Influence of Underground In-flow Water to Coal Production in Changsung Coal Mine)

  • 김두영;김영달
    • 자원환경지질
    • /
    • 제13권4호
    • /
    • pp.229-239
    • /
    • 1980
  • A various kinds of harmful gases in the gallery and the increasing quantity of in-flow water are the important factors causing mainly the decline in production. In this thesis, the increase and decrease of in-flow water which effects the out put have been investigated and analysed in the statistical method. Through the results obtained together with the stastistical data some typical interreation formula between the quantity of in-flow water and production have been induced and the productive percentage in season was examined with special reference to Changsung Coal Mine. The formulas are as fallows: (1) Underground in-flow water to production; $Y=-5.74x^2+108.9x+6,346.6$ where, Y: production(tons/day): x:in-flow water($m^3/min$), (2) Rain and Snow fall to production; P=6.555-1.591 R+1.282S where, P;production(tons/day); R:rain fall(mm); S : snowfall(cm), (3) Productivity ratio in season compared with the average annual production; 1st quarter of year:100.1%, 2nd quarter of year: 100.3%, 3rd quarter of year: 97.2%, 4th quarter of year: 102.4%.

  • PDF

단일 및 분할 방사선조사가 백서 악하선 미세혈관계에 미치는 영향 (EFFECTS OF THE SINGLE AND FRACTIONATED IRRADIATION ON THE MICROVASCULATURE OF THE RAT SUBMANDIBULAR GLAND)

  • 김석호;최갑식
    • 치과방사선
    • /
    • 제23권1호
    • /
    • pp.71-85
    • /
    • 1993
  • The purpose of the study was to investigate the effects of the single and fractionated irradiation on the microvascular structure of the submandibular gland in rats. For this study, 90 Sprague-Dawley strain rats were irradiated to their neck region with equal split doses of 9Gy for a 4 hours interval and 15Gy single dose by 6MV X-irradiation and sacrificed on the 1st, 3rd, 7th, 14th and 27th day after irradiation. The author observed histological changes at Hematoxylin and Eosin staining and PAS staining under a light microscope, and also observed distribution and structural changes of the microvasculature in rat submandibular gland using a scanning electron microscope by forming vascular resin casting. The results were as follows: 1. In the light microscopic examination, the microvasculature was slightly dilated and decreased in number on the 1st day after irradiation, and increase in number of microvasculature was observed on the 3rd day after irradiation. And then distribution of microvasculature was markedly increased on the 7th day after iradiation, but decreased on th 14th day after irradiation again. Such changes were greater in the single irradiated group than in the fractionated irradiated group. 2. The reaction to PAS staining on glandular cell was decreased on the 1st and the 3rd day after irradiation, and recovered on the 7th day after irradiation. The reaction was decreased on the 14th day after irradiation again, and recovered on the 28th day after irradiation. Changes were more apparent in the single irradiated group. 3. In the scanning electron microscopic examination, early changes of microvasculature were decreased capillary density, dilation of conduits and meandering. Increased capillary dentsity or anastomosis due to vascular reproduction and smooth curved running were observed on the 7th and 14th day after irradiation. Decreased capillary and smooth running tendency were observed on the 28th day after irradiation again. Such changes were greater in the single irradiated group than in the fractionated irradiated group.

  • PDF

Osteoporosis prediction from the mandible using cone-beam computed tomography

  • Barngkgei, Imad;Haffar, Iyad Al;Khattab, Razan
    • Imaging Science in Dentistry
    • /
    • 제44권4호
    • /
    • pp.263-271
    • /
    • 2014
  • Purpose: This study aimed to evaluate the use of dental cone-beam computed tomography (CBCT) in the diagnosis of osteoporosis among menopausal and postmenopausal women by using only a CBCT viewer program. Materials and Methods: Thirty-eight menopausal and postmenopausal women who underwent dual-energy X-ray absorptiometry (DXA) examination for hip and lumbar vertebrae were scanned using CBCT (field of view: $13cm{\times}15cm;$ voxel size: 0.25 mm). Slices from the body of the mandible as well as the ramus were selected and some CBCT-derived variables, such as radiographic density (RD) as gray values, were calculated as gray values. Pearson's correlation, one-way analysis of variance (ANOVA), and accuracy (sensitivity and specificity) evaluation based on linear and logistic regression were performed to choose the variable that best correlated with the lumbar and femoral neck T-scores. Results: RD of the whole bone area of the mandible was the variable that best correlated with and predicted both the femoral neck and the lumbar vertebrae T-scores; further, Pearson's correlation coefficients were 0.5/0.6 (p value=0.037/0.009). The sensitivity, specificity, and accuracy based on the logistic regression were 50%, 88.9%, and 78.4%, respectively, for the femoral neck, and 46.2%, 91.3%, and 75%, respectively, for the lumbar vertebrae. Conclusion: Lumbar vertebrae and femoral neck osteoporosis can be predicted with high accuracy from the RD value of the body of the mandible by using a CBCT viewer program.

Preparative separation of minor saponins from Panax notoginseng leaves using biotransformation, macroporous resins, and preparative high-performance liquid chromatography

  • Liu, Fang;Ma, Ni;Xia, Fang-Bo;Li, Peng;He, Chengwei;Wu, Zhenqiang;Wan, Jian-Bo
    • Journal of Ginseng Research
    • /
    • 제43권1호
    • /
    • pp.105-115
    • /
    • 2019
  • Background: Ginsenosides with less sugar moieties may exhibit the better adsorptive capacity and more pharmacological activities. Methods: An efficient method for the separation of four minor saponins, including gypenoside XVII, notoginsenoside Fe, ginsenoside Rd2, and notoginsenoside Fd, from Panax notoginseng leaves (PNL) was established using biotransformation, macroporous resins, and subsequent preparative high-performance liquid chromatography. Results: The dried PNL powder was immersed in the distilled water at $50^{\circ}C$ for 30 min for converting the major saponins, ginsenosides Rb1, Rc, Rb2, and Rb3, to minor saponins, gypenoside XVII, notoginsenoside Fe, ginsenoside Rd2, and notoginsenoside Fd, respectively, by the enzymes present in PNL. The adsorption characteristics of these minor saponins on five types of macroporous resins, D-101, DA-201, DM-301, X-5, and S-8, were evaluated and compared. Among them, D-101 was selected due to the best adsorption and desorption properties. Under the optimized conditions, the fraction containing the four target saponins was separated by D-101 resin. Subsequently, the target minor saponins were individually separated and purified by preparative high-performance liquid chromatography with a reversed-phase column. Conclusion: Our study provides a simple and efficient method for the preparation of these four minor saponins from PNL, which will be potential for industrial applications.

초등학생들의 굴절이상과 시력과의 관계 (Relationship of Visual Acuity and Refractive Error in Elementary School Students)

  • 박은규
    • 한국안광학회지
    • /
    • 제13권4호
    • /
    • pp.141-143
    • /
    • 2008
  • 목적: 본 논문에서는 초등학생들의 시력과 굴절이상과의 관계를 조사하고 이들의 상관관계를 분석하였다. 방법: 초등학교 1, 3, 6학년 200명(400안)을 선정하여 나안시력과 굴절이상을 측정하였다. 결과: 저학년에서 고학년으로 갈수록 근시도는 증가하고, 시력은 감소하였고, 1차 회귀직선방정식은 Y=2.1471X-3.1484 (F=313.9377, P<0.001)로 나타났다. 원시도와 시력에 대한 1차 회귀직선방정식은 Y=-0.6854X+1.1764 (F=7.054, P<0.01)로 나타나 원시도와 시력 감소의 유의한 상관관계가 확인되었다. 시력과 난시도의 관계는 Y=2.2509X-2.8738 (F=21.7952, P<0.001)로 나타나 유의한 상관관계가 확인되었다. 결론: 근시, 원시, 난시 모두 시력과 유의한 상관관계가 확인되었다.

  • PDF

3차 의료기관 응급의료센터로 전원되는 환자에 대한 조사연구 - 중복 재검사에 관한 조사 - (A study on patients transferred to emergency medical center of university hospital -About reexamination status of patients transferred -)

  • 유순규
    • 한국응급구조학회지
    • /
    • 제3권1호
    • /
    • pp.20-32
    • /
    • 1999
  • The purpose of this retrospective research of 603 patients who were transferred to the emergency medical center of university hospital from 1 Jan, 1998 to 31 Jan, 1998 was making of basic data for emergency medical transfer system improvement countermeasure and the point at issue of overlapping reexamination ststus of patients transfered to emergency medical center of university hospital from 1,2 level hospital. The data analysis was done by SPSS, t-test, ANOVA, Pearson correlation. The results were as follows: 1. Male to female ratio was 1.7:1 and peak age group was patients over forties and under nine years of age(70.5%) 2. Traumatic patients were 17.8%, motor vehicle accident patients were 16.7% and Non-traumatic patients were 65.3%. Transferring hospital was divided into 2groups: primary hospital, secondary hospital. The majority was secondary hospital(73.3%). The result of symptom severity classification of patients transferred to 3rd emergency medical center was urgent patients 32.5%, emergency patients 33.58%, non-emergency patients 34.0% 3. Most highest score items amoung overlapping reexamination of patients transfered to emergency medical center of university hospital from 1,2 level hospital were CBC test, simple X-ray (0.93점), CBC test(0.97점), urin test(0.88점), chemistry test(0.94점), simple X-ray(0.98점), CT(0.42점), EKG(0.89점) amoung overlapping reexamination of motor vehicle accident patients were more higher reexamination score than traumatic patients and non-traumatic patients 4. CBC test(P<0.001), urin test(P<0.001), chemistry test(P<0.001), simple X-ray(P<0.001), CT(P<0.01), EKG(P<0.001) amoung overlapping reexamination of patients in 2 level hospital were more higher reexamination score than 1 level hospital patients 5. About symptom severity classification of patients transferred to 3rd emergency medical center, CBC test(P<0.001), urin test(P<0.001), chemistry test(P<0.001), simple X-ray(P<0.01), CT(P<0.001), EKG(P<0.001) amoung overlapping reexamination items in urgent patients were more higher reexamination score than other patients 6. Influencing variation for overlapping reexamination in hospital was CBC test(P<0.001), CT (P<0.001), MRI (P<0.05).

  • PDF

cdma2000 1x 이동국 모뎀을 위한 하드웨어-소프트웨어 동시 검증 방법 (A Hardware-Software Co-verification Methodology for cdma2000 1x Compliant Mobile Station Modem)

  • 한태희;한성철;한동구;김성룡;한금구;황석민;김경호
    • 대한전자공학회논문지SD
    • /
    • 제39권7호
    • /
    • pp.46-56
    • /
    • 2002
  • 본 논문에서는 3세대 이동 통신 표준안의 하나인 cdma2000 1x를 지원하는 이동국 모뎀칩 개발에 사용된 하드웨어-소프트웨어 동시 검증 방법과 환경에 대해 기술한다. 하드웨어의 프로토타이핑 없이 레지스터 전송단계의 가상 하드웨어 모델과 물리 계층의 소프트웨어 모델을 채널링크 시뮬레이터, 다기능 테스트벤치와 유기적으로 결합하여 효과적인 통합 검증 환경을 구축함으로써 300만 게이트급의 복잡한 시스템 집적회로 개발 기간과 배용을 대폭 단축하였다.