A Study on Dosimetry for Small Fields of Photon Beam (광자선 소조사면의 선량 측정에 관한 연구)

  • 강위생;하성환;박찬일
    • Progress in Medical Physics
    • /
    • v.5 no.2
    • /
    • pp.57-68
    • /
    • 1994
  • Purpose : The purposes are to discuss the reason to measure dose distributions of circular small fields for stereotactic radiosurgery based on medical linear accelerator, finding of beam axis, and considering points on dosimetry using home-made small water phantom, and to report dosimetric results of 10MV X-ray of Clinac-18, like as TMR, OAR and field size factor required for treatment planning. Method and material : Dose-response linearity and dose-rate dependence of a p-type silicon (Si) diode, of which size and sensitivity are proper for small field dosimetry, are determined by means of measurement. Two water tanks being same in shape and size, with internal dimension, 30${\times}$30${\times}$30cm$^3$ were home-made with acrylic plates and connected by a hose. One of them a used as a water phantom and the other as a device to control depth of the Si detector in the phantom. Two orthogonal dose profiles at a specified depth were used to determine beam axis. TMR's of 4 circular cones, 10, 20, 30 and 40mm at 100cm SAD were measured, and OAR's of them were measured at 4 depths, d$\sub$max/, 6, 10, 15cm at 100cm SCD. Field size factor (FSF) defined by the ratio of D$\sub$max/ of a given cone at SAD to MU were also measured. Result : The dose-response linearity of the Si detector was almost perfect. Its sensitivity decreased with increasing dose rate but stable for high dose rate like as 100MU/min and higher even though dose out of field could be a little bit overestimated because of low dose rate. Method determining beam axis by two orthogonal profiles was simple and gave 0.05mm accuracy. Adjustment of depth of the detector in a water phantom by insertion and remove of some acryl pates under an auxiliary water tank was also simple and accurate. TMR, OAR and FSF measured by Si detector were sufficiently accurate for application to treatment planning of linac-based stereotactic radiosurgery. OAR in field was nearly independent of depth. Conclusion : The Si detector was appropriate for dosimetry of small circular fields for linac-based stereotactic radiosurgery. The beam axis could be determined by two orthogonal dose profiles. The adjustment of depth of the detector in water was possible by addition or removal of some acryl plates under the auxiliary water tank and simple. TMR, OAR and FSF were accurate enough to apply to stereotactic radiosurgery planning. OAR data at one depth are sufficient for radiosurgery planning.

  • PDF

Development of Position Encoding Circuit for a Multi-Anode Position Sensitive Photomultiplier Tube (다중양극 위치민감형 광전자증배관을 위한 위치검출회로 개발)

  • Kwon, Sun-Il;Hong, Seong-Jong;Ito, Mikiko;Yoon, Hyun-Suk;Lee, Geon-Song;Sim, Kwang-Souk;Rhee, June-Tak;Lee, Dong-Soo;Lee, Jae-Sung
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.6
    • /
    • pp.469-477
    • /
    • 2008
  • Purpose: The goal of this paper is to present the design and performance of a position encoding circuit for $16{\times}16$ array of position sensitive multi-anode photomultiplier tube for small animal PET scanners. This circuit which reduces the number of readout channels from 256 to 4 channels is based on a charge division method utilizing a resistor array. Materials and Methods: The position encoding circuit was simulated with PSpice before fabrication. The position encoding circuit reads out the signals from H9500 flat panel PMTs (Hamamatsu Photonics K.K., Japan) on which $1.5{\times}1.5{\times}7.0\;mm^3$ $L_{0.9}GSO$ ($Lu_{1.8}Gd_{0.2}SiO_{5}:Ce$) crystals were mounted. For coincidence detection, two different PET modules were used. One PET module consisted of a $29{\times}29\;L_{0.9}GSO$ crystal layer, and the other PET module two $28{\times}28$ and $29{\times}29\;L_{0.9}GSO$ crystal layers which have relative offsets by half a crystal pitch in x- and y-directions. The crystal mapping algorithm was also developed to identify crystals. Results: Each crystal was clearly visible in flood images. The crystal identification capability was enhanced further by changing the values of resistors near the edge of the resistor array. Energy resolutions of individual crystal were about 11.6%(SD 1.6). The flood images were segmented well with the proposed crystal mapping algorithm. Conclusion: The position encoding circuit resulted in a clear separation of crystals and sufficient energy resolutions with H9500 flat-panel PMT and $L_{0.9}GSO$ crystals. This circuit is good enough for use in small animal PET scanners.

The Study on Properties and Application of Enhanced Dynamic Wedge Factor (향상된 동적쐐기인자(Enhanced Dynamic Wedge Factor)의 특성 및 적용에 관한 고찰)

  • Kim, Dae-Sup;Ban, Tae-Joon;Yeom, Mi-Suk;Yoo, Soon-Mi;Lee, Woo-Seok;Back, Geum-Mun;Kwon, Kyung-Tae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.22 no.1
    • /
    • pp.53-60
    • /
    • 2010
  • Purpose: We try to calculate EDW-factor easily with the formula applies essential data of EDW-factor and evaluate the validity through a measurement. Materials and Methods: We used the given value of GSTT (Golden Segmented Treatment Table) for the calculation of the EDW-factor. As to the experimental device, 0.6 cc farmer-type ion-chamber, an electrometer and water- phantom were used. A measurement was made at the maximum dose depth of the photon beam energy 6 MV and 15 MV under the condition that SSD (Source to Surface Distance) was 100 cm. The angle of the EDW (Enhanced Dynamic Wedge) which we use in an experiment was 60 degree, 30 degree, 20 degree in the Y1-OUT direction. We used Eclipse planning system (Varian, USA) as RTP system and the EDW-factor was calculated about all fields and EDW direction. In order to show the EDW-factor feature, a measurement was made at the selected field that verify the influence of the dependability about X, Y jaw and off-axis field. Results: When we change the Y1 field, it influence on the EDW-Factor and measured value. But the error between measured values and calculated values was less than 1%. The experimental result indicated the tendency that the error of the result of calculation and measured value becomes smaller as the EDW angle become smaller whether the calculation point (measurement point) and iso-center are same or not. The influence of the field size and energy did not show up. We simulated with the same condition using the RTP system. And we found that it makes no difference between the MU which is calculated manually by applying the EDW-Factor obtained from the commercial program and the value which is calculated by using RTP system. Conclusion: We excluded fitting value from well-known EDW-Factor formula and calculated EDW-factor with the formula applies essential data of EDW-factor only. As a result, there are no significant difference between the measured value and calculated value and it showed errors less than 1%. Also, we implemented the commercial program to calculate EDW-Factor conveniently without measure a factor on each field.

  • PDF

Results of Radiation Therapy for Carcinoma of the Uterine Cervix (자궁경부암의 방사선치료 성적)

  • Lee Kyung-Ja
    • Radiation Oncology Journal
    • /
    • v.13 no.4
    • /
    • pp.359-368
    • /
    • 1995
  • Purpose : This is a retrospective analysis for pattern of failure, survival rate and prognostic factors of 114 patients with histologically proven invasive cancer of the uterine cervix treated with definitive irradiation. Materials and Methods : One hundred fourteen patients with invasive carcinoma of the cervix were treated with a combination of intracavitary irradiation using Fletcher-Suit applicator and external beam irradiation by 6MV X-ray at the Ewha Womans University Hospital between March 1982 and Mar 1990. The median age was 53 years(range:30-77 years). FIGO stage distribution was 19 for IB, 23 for IIA, 42 for IIB, 12 for IIIA and 18 for IIIB. Summation dose of external beam and intracavitary irradiation to point A was 80-90 Gy(median:8580 cGy) in early stage(IB-IIA) and 85-100 Gy(median:8850 cGy) in advanced stage(IIB-IIIB). Kaplan-Meier method was used to estimate the survival rate and multivariate analysis for progrostic factors was performed using the Log likelihood for Weibull Results : The pelvic failure rates by stage were $10.5{\%}$ for IB. $8.7{\%}$ for IIA, $23.8{\%}$ for IIB, $50.0{\%}$ for IIIA and $38.9{\%}$ for IIIB. The rate of distant metastasis by stage were $0{\%}$ for IB, $8.7{\%}$ for IIA, $4.8{\%}$ for IIB. $0{\%}$ for IIIA and $11.1{\%}$ for IIIB. The time of failure was from 3 to 50 months and with median of 15 months after completion of radiation therapy. There was no significant coorelation between dose to point A($\leq$90 Gy vs >90 Gy) and pelvic tumor control(P>0.05). Incidence rates of grade 2 rectal and bladder complications were $3.5{\%}$(4/114) and $7{\%}$(8/114), respectively and 1 patient had sigmoid colon obstruction and 1 patient had severe cystitis. Overall 5-year survival rate was $70.5{\%}$ and disease-free survival rate was $53.6{\%}$. Overall 5-year survival rate by stage was $100{\%}$ for IB, $76.9{\%}$ for IIA, $77.6{\%}$ for IIB $87.5{\%}$ for IIIA and $69.1{\%}$ for IIIB. Five-rear disease-free survival rate by stage was $81.3{\%}$ for IB, $67.9{\%}$ for IIA, $46.8{\%}$ for IIB, $45.4{\%}$ for IIIA and $34.4{\%}$ for IIIB. The prognostic factors for disease-free survival rate by multivariate analysis was performance status(p= 0.0063) and response rate after completion of radiation therapy(p= 0.0026) but stage, age and radiation dose to point A were not siginificant. Conclusion : The result of radiation therapy for early stage of the uterine cervix cancer was relatively good but local control rate and survival rate in advanced stage were poor inspite of high dose irradiation to point A above 90 Gy. Prospective randomized studies are recommended to establish optimal tumor doses for various stages and volume of carcinoma of uterine cervix, And ajuvant chemotherapy or radiation-sensitizing agents must be considered to increase the pelvic control and survival rate in advanced cancer of uterine cervix.

  • PDF

Effective Dose Evaluation using Clinical PET/CT Acquisition Protocols (전신 PET/CT 영상 획득 프로토콜을 이용한 유효선량 평가)

  • Nam, So-Ra;Son, Hye-Kyung;Lee, Sang-Hoon;Lee, Chang-Lae;Cho, Hyo-Min;Kim, Hee-Joung
    • Progress in Medical Physics
    • /
    • v.17 no.3
    • /
    • pp.173-178
    • /
    • 2006
  • The purpose of this study was to evaluate the radiation dose for clinical PET/CT protocols in clinical environments using Alderson phantom and TLDs. Radiation doses were evaluated for both Philips GEMINI 16 slice PET/CT system and GE DSTe 16 slice PET/CT system. Specific organ doses with $^{137}Cs$ transmission scan, high quality CT scan and topogram in philips GEMINI PET/CT system were measured. Specific organ doses with CT scan for attenuation map, CT scan for diagnosis and topogram in GE DSTe PET/CT system were also measured. The organs were selected based on ICRP60 recommendation. The TLDs used for measurements were selected for within an accuracy of ${\pm}5%$ and calibrated in 10 MV X-ray radiation field. The effective doses for $^{137}Cs$ transmission scan, high qualify scan, and topogram in Philips GEMINI PET/CT system were $0.14{\pm}0.950,\;29.49{\pm}1.508\;and\;0.72{\pm}0.032mSv$ respectively. The effective doses for CT scan to make attenuation map, CT scan to diagnose and topogram in GE DSTe PET/CT system were $20.06{\pm}1.003,\;24.83{\pm}0.805\;and\;0.27{\pm}0.008mSv$ respectively. We evaluated the total effective dose by adding effective dose for PET Image. The total PET/CT doses for Philips GEMINI PET/CT (Topogram+$^{137}Cs$ transmission scan+PET, Topogram+high qualify CT+PET) and GE DSTe PET/CT (Topogram +CT for attenuation map+ PET, Topogram+diagnostic CT+ PET) are $7.65{\pm}0.951,\;37.00{\pm}1.508,\;27.12{\pm}1.003\;and\;31.89{\pm}0.805mSv$ respectively. Further study may be needed to be peformed to find optimal PET/CT acquisition protocols for reducing the patient exposure with good image qualify.

  • PDF

Study on the Small Fields Dosimetry for High Energy Photon-based Radiation Therapy (고에너지 광자선을 이용한 방사선 치료 시 소조사면에서의 흡수선량평가에 관한 연구)

  • Jeong, Hae-Sun;Han, Young-Yih;Kum, O-Yeon;Kim, Chan-Hyeong
    • Progress in Medical Physics
    • /
    • v.20 no.4
    • /
    • pp.290-297
    • /
    • 2009
  • In case of radiation treatment using small field high-energy photon beams, an accurate dosimetry is a challenging task because of dosimetrically unfavorable phenomena such as dramatic changes of the dose at the field boundaries, dis-equilibrium of the electrons, and non-uniformity between the detector and the phantom materials. In this study, the absorbed dose in the phantom was measured by using an ion chamber and a diode detector widely used in clinics. $GAFCHROMIC^{(R)}$ EBT films composed of water equivalent materials was also evaluated as a small field detector and compared with ionchamber and diode detectors. The output factors at 10 cm depth of a solid phantom located 100 cm from the 6 MV linear accelerator (Varian, 6 EX) source were measured for 6 field sizes ($5{\times}5\;cm^2$, $2{\times}2\;cm^2$, $1.5{\times}1.5\;cm^2$, $1{\times}1\;cm^2$, $0.7{\times}0.7\;cm^2$ and $0.5{\times}0.5\;cm^2$). As a result, from $5{\times}5\;cm^2$ to $1.5{\times}1.5\;cm^2$ field sizes, absorbed doses from three detectors were accurately identified within 1%. Wheres, the ion chamber underestimated dose compared to other detectors in the field sizes less than $1{\times}1\;cm^2$. In order to correct the observed underestimation, a convolution method was employed to eliminate the volume averaging effect of an ion chamber. Finally, in $1{\times}1\;cm^2$ field the absorbed dose with a diode detector was about 3% higher than that with the EBT film while the dose with the ion chamber after volume correction was 1% lower. For $0.5{\times}0.5\;cm^2$ field, the dose with the diode detector was 1% larger than that with the EBT film while dose with volume corrected ionization chamber was 7% lower. In conclusion, the possibility of $GAFCHROMIC^{(R)}$ EBT film as an small field dosimeter was tested and further investigation will be proceed using Monte Calro simulation.

  • PDF

The Effect of Photoneutron Dose in High Energy Radiotherapy (10 MV 이상 고에너지 치료 시 발생되는 광중성자의 영향)

  • Park, Byoung Suk;Ahn, Jong Ho;Kwon, Dong Yeol;Seo, Jeong Min;Song, Ki Weon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.1
    • /
    • pp.9-14
    • /
    • 2013
  • Purpose: High-energy radiotherapy with 10 MV or higher develops photoneutron through photonuclear reaction. Photoneutron has higher radiation weighting factor than X-ray, thus low dose can greatly affect the human body. An accurate dosimetric calculation and consultation are needed. This study compared and analyzed the dose change of photoneutron in terms of space according to the size of photon beam energy and treatment methods. Materials and Methods: To measure the dose change of photoneutron by the size of photon beam energy, patients with the same therapy area were recruited and conventional plans with 10 MV and 15 MV were each made. To measure the difference between the two treatment methods, 10 MV conventional plan and 10 MV IMRT plan was made. A detector was placed at the point which was 100 cm away from the photon beam isocenter, which was placed in the center of $^3He$ proportional counter, and the photoneutron dose was measured. $^3He$ proportional counter was placed 50 cm longitudinally superior to and inferior to the couch with the central point as the standard to measure the dose change by position changes. A commercial program was used for dose change analysis. Results: The average integral dose by energy size was $220.27{\mu}Sv$ and $526.61{\mu}Sv$ in 10 MV and 15 MV conventional RT, respectively. The average dose increased 2.39 times in 15 MV conventional RT. The average photoneutron integral dose in conventional RT and IMRT with the same energy was $220.27{\mu}Sv$ and $308.27{\mu}Sv$ each; the dose in IMRT increased 1.40 times. The average photoneutron integral dose by measurement location resulted significantly higher in point 2 than 3 in conventional RT, 7.1% higher in 10 MV, and 3.0% higher in 15 MV. Conclusion: When high energy radiotherapy, it should consider energy selection, treatment method and patient position to reduce unnecessary dose by photoneutron. Also, the dose data of photoneutron needs to be systematized to find methods to apply computerization programs. This is considered to decrease secondary cancer probabilities and side effects due to radiation therapy and to minimize unnecessary dose for the patients.

  • PDF

Study on the Various Size Dependence of Ionization Chamber in IMRT Measurement to Improve Dose-accuracy (세기조절 방사선치료(IMRT)의 환자 정도관리에서 다양한 이온전리함 볼륨이 정확도에 미치는 영향)

  • Kim, Sun-Young;Lee, Doo-Hyun;Cho, Jung-Keun;Jung, Do-Hyeung;Kim, Ho-Sick;Choi, Gye-Sook
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.18 no.1
    • /
    • pp.1-5
    • /
    • 2006
  • Purpose: IMRT quality assurance(Q.A) is consist of the absolute dosimetry using ionization chamber and relative dosimetry using the film. We have in general used 0.015 cc ionization chamber, because small size and measure the point dose. But this ionization chamber is too small to give an accurate measurement value. In this study, we have examined the degree of calculated to measured dose difference in intensity modulated radiotherapy(IMRT) based on the observed/expected ratio using various kinds of ion chambers, which were used for absolute dosimetry. Materials and Methods: we peformed the 6 cases of IMRT sliding-window method for head and neck cases. Radiation was delivered by using a Clinac 21EX unit(Varian, USA) generating a 6 MV x-ray beam, which is equipped with an integrated multileaf collimator. The dose rate for IMRT treatment is set to 300 MU/min. The ion chamber was located 5cm below the surface of phantom giving 100cm as a source-axis distance(SAD). The various types of ion chambers were used including 0.015cc(pin point type 31014, PTW. Germany), 0.125 cc(micro type 31002, PTW, Germany) and 0.6 cc(famer type 30002, PTW, Germany). The measurement point was carefully chosen to be located at low-gradient area. Results: The experimental results show that the average differences between plan value and measured value are ${\pm}0.91%$ for 0.015 cc pin point chamber, ${\pm}0.52%$ for 0.125 cc micro type chamber and ${\pm}0.76%$ for farmer type 0.6cc chamber. The 0.125 cc micro type chamber is appropriate size for dose measure in IMRT. Conclusion: IMRT Q.A is the important procedure. Based on the various types of ion chamber measurements, we have demonstrated that the dose discrepancy between calculated dose distribution and measured dose distribution for IMRT plans is dependent on the size of ion chambers. The reason is small size ionization chamber have the high signal-to-noise ratio and big size ionization chamber is not located accurate measurement point. Therefore our results suggest the 0.125 cc farmer type chamber is appropriate size for dose measure in IMRT.

  • PDF

Optimum Dose Combination of External Radiation and High Dose Rate ICR in FIGO IB Uterine Cervical Cancer (병기 IB 자궁경부암의 방사선치료에서 외부방사선치료와 고선량율 강내치료의 최적선량 배합)

  • Lee Sang Wook;Suh Chang Ok;Chung Eun Ji;Kim Woo Cheol;Chang Sei Kyung;Keum Ki Chang;Kim Gwi Eon
    • Radiation Oncology Journal
    • /
    • v.14 no.3
    • /
    • pp.201-209
    • /
    • 1996
  • Purpose : To assess the efficacy of high dose rate - intracavitary radio-therapy (HDR-ICR) in the radiotherapy of FIGO stage IB squamous cell carcinoma of uterine cervix and to determine the optimum dose combination scheme of external radiotherapy and ICR to achieve acceptable local control without severe complication. Materials and Methods : One hundred and sixty two patients with FIGO stage Ib squamous cell carcinoma of uterine cervix who received definitive radiotherapy between May 1979 and December 1990 were retrospectively analyzed. All the patients received external radiotherapy combined with HDR-ICR. External dose of 40-46 Gy in 4.5-5 weeks was given to whole pelvis(median 45 Gy) and ICR dose of 30-39 Gy in 10-13 times was given to the point A. Midline shielding was done after 20-45 Gy of external radiotherapy(median 40 Gy) Summation of external dose Plus ICR dose to the point A range were 64.20-95.00 Gy. and mean was 83.94 Gy. We analyzed the local control rate, survival rate, and late complication rate. Rusults : Initial complete response rate was $99.4\%$ for all patients. Overall 5-year survival rate was $91.1\%$ and 5-year disease free survival rate was $90.9\%$. Local failure rate was $4.9\%$ and distant failure rate was $4.3\%$. Tumor size was the only significant prognostic factor. When tumor size greater than 3cm, 5-rear survival rate was $92.6\%$ and less than 3cm, that was $79.6\%$. Late complication rate was $23.5\%$ with $18.5\%$ of rectal complication and $4.9\%$ of bladder complication. Mean rectal dose summation of external midline dose plus ICR rectal point dose was lower in the patients without rectal complication(74.88 Gr) than those with rectal complication (78.87 Gy). Complication rate was increased with low rate of improvement of survival rate when summation of external midline dose plus point A or point R dose by ICR was greater than 70-75 Gy. Conclusion : The definitive radiation therapy using high dose rate ICR in FIGO stage IB uterine cervical cancer is effective treatment modality with good local control and survival rate without severe complication.

  • PDF

Characteristics of the Maximum Glow Intensity According to the Thermoluminescent Phosphors used in the Absorbed Dose Measurement of the Radiation Therapy (방사선치료 선량 측정에 사용되는 열형광체에 따른 최대 형광 강도 특성)

  • Kang, Suman;Im, Inchul;Park, Cheolwoo;Lee, Mihyeon;Lee, Jaeseung
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.4
    • /
    • pp.181-187
    • /
    • 2014
  • The purpose of this study were to analyze the characteristic of the glow curves in order to the glow temperature of the thermoluminescent dosimeters (TLDs) for the absorbed dose measurement of the radiation therapy. In this study, we was used the TLDs of the LiF:Mg${\cdot}$Ti, LiF:Mg${\cdot}$Cu${\cdot}$P, $CaF_2$:Dy, $CaF_2$:Mn (Thermo Fisher Scientific Inc., USA). The source-to-solid dry phantom (RW3 slab, IBA Dosmetry, Germany) surface distance was set at 100 cm, and the exposure dose of 100 MU (monitor unit) was used 6- and 15-MV X-rays, and 6- and 12-MeV electron beams in the reference depth, respectively. After the radiations exposure, we were to analyze the glow curves by using the TL reader (Hashaw 3500, Thermo Fisher Scientific Inc., USA) at the fixed heating rate of $15^{\circ}C/sec$ from $50^{\circ}C$ to $260^{\circ}C$. The glow peaks, the trapping level in the captured electrons and holes combined with the emitted light, were discovered the two or three peak. When the definite increasing the temperature of the TLDs, the maximum glow peak representing the glow temperature was follow as; $LiF:Mg{\cdot}Ti$: $185.5{\pm}1.3^{\circ}C$, $LiF:Mg{\cdot}Ti$: $135.0{\pm}5.1^{\circ}C$, $CaF_2$:Dy: $144.0{\pm}1.6^{\circ}C$, $CaF_2$:Mn: $294.3{\pm}3.8^{\circ}C$, respectively. Because the glow emission probability of the captured electrons depend on the heating temperature after the exposure radiation, TLDs by applying the fixed heating rate, the accuracy of measurement will be able to improve within the absorbed dose measurement of the radiation therapy.