• 제목/요약/키워드: X-레이

검색결과 83건 처리시간 0.028초

이중에너지 엑스선 흡광분석법을 이용한 골밀도검사의 관리법 (Management Methods of Bone Mineral Density Examination Using Dual Energy X-ray Absorptiometry)

  • 김호성;김태형;김상현
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제41권4호
    • /
    • pp.351-360
    • /
    • 2018
  • In recent years, demand for examination of bone mineral density (BMD) is increasing in Korea according aging society. Therefore, it is required to develop an efficient management program that can increase the safety and reliability of Dual Energy X-ray Absorptiometry (DXA) that can be applied to the criteria of the World Health Organization. It is necessary to develop a management program that can design a program to improve the accuracy and precision of the results of the analysis and to improve the accuracy of diagnosis of osteoporosis by development a high quality DXA report. It is recommended to prepare the examination manuals and to establish procedures of standard operating including the program to prevent the pitfalls during the examination, the compatibility evaluation of the examination data, and the contents of the radiation safety. In addition, relevant regulations on the production of high-quality DXA reports are required and government and related agencies should introduce individual and facility recognition programs through DXA measurement and education programs and training. It is considered that efforts should be made to prepare high quality DXA report by guidelines on all aspects of BMD for preparation about aging society.

상대운동이 있는 중첩격자계에 효율적인 Hole Searching Algorithm 개발 (Efficient Hole Searching Algorithm for the Overset Grid System with Relative Body Motion)

  • 이선형;채상현;오세종;이관중
    • 한국항공우주학회지
    • /
    • 제39권11호
    • /
    • pp.995-1004
    • /
    • 2011
  • Overset 격자계에서 사용되는 Object X-rays Method는 홀점 탐색의 일부인 교차점 탐색에 복잡한 벡터계산을 사용하고 개별 배경격자점에 대하여 물체 내외부를 판별하여 홀점을 탐색하므로 많은 시간이 소요된다. 특히 격자의 상대운동이 있을 경우 매 시간간격 마다 홀점 탐색을 수행해야 하므로 계산 시간이 가중된다. 이러한 문제를 해결하기 위해 본 연구에서는 홀점 탐색시간을 줄일 수 있는 효율적인 탐색 알고리즘을 제안한다. 빠른 탐색을 위해 격자점 수가 줄어든 가상의 표면을 사용하고 복잡한 벡터계산을 통한 교차점 탐색 대신 논리연산자를 사용하는 내외부 판별법을 사용하였다. 또한 개별 배경격자점에 대해 홀점 판별을 수행하는 대신 일괄로 홀점을 지정하여 탐색속도를 향상시켰다. 물체의 상대운동이 있을 경우 가상의 표면이 상대 운동하여 기존 방법에 비해서 홀점 탐색시간을 감소시킬 수 있었다. 임의의 2차원, 3차원 형상에 대하여 기존의 hole searching 알고리즘과 홀점 탐색속도를 비교한 결과를 제시하였다.

Array 검출 모듈 신호처리 시스템의 테스트 소프트웨어 프로그램 개발 및 디지털 신호처리 보드 개발 (Development of Test Software Program and Digital Signal Processing Board for Array Module Signal Processing System)

  • 박지오;김영길;이진
    • 한국정보통신학회논문지
    • /
    • 제22권3호
    • /
    • pp.499-505
    • /
    • 2018
  • 전 세계적으로 해운물류 안전 보안체계가 강화됨에 따라 국가물류보안 체계 구축을 위한 해운물류안전 보안 핵심기술 개발이 이루어지고 있다. 또한 미국에서 2018년 시행예정인 컨테이너 사전 100% 전수검사에 대응하기 위한 컨테이너 검색기의 핵심구성 요소인 Array 검출 시스템의 국산화 개발이 필요하다. 본 논문에서는 현재 자체 개발한 Test Digital 신호처리 Board를 가지고 TI-RTOS(Texas Instruments - Real Time Operating System)를 이용하여 개발한 Test Software Program을 제안한다. M4 MCU를 기반으로 GPIO, SRAM, TCP/IP와 SDcard등을 테스트 할 수 있는 프로그램을 개발했다. 또한 Array 검출 system 중 자체 개발한 Digital Signal Processing Board에 대한 연구를 제안하고자 한다. M4 MCU를 테스트 할 수 있는 테스트보드를 개발했고 FPGA와 MCU가 결합된 통한 X-RAY 디지털 신호처리 보드를 개발했다.

다공질 사암의 층리에 따른 국부적 공극특성 변화와 수리 이방성 특성 (A Study of Locally Changing Pore Characteristics and Hydraulic Anisotropy due to Bedding of Porous Sandstone)

  • 양화영;김한나;김경민;김광염;민기복
    • 터널과지하공간
    • /
    • 제23권3호
    • /
    • pp.228-240
    • /
    • 2013
  • 퇴적암에서 나타나는 이방성은 층리에 의한 영향이 크며, 암석의 수리적 특성에도 영향을 주게 된다. 본 연구에서는 층리가 발달한 다공질 사암을 대상으로, 층리구조에 의해 발생한 공극구조 이방성이 사암의 수리 이방성에 미치는 영향을 분석하였다. 사암의 공극구조 이방성 파악을 위해 X-ray CT(computed tomography)를 이용하여 내부 공극률의 변화양상을 분석하였다. 층리방향에 따른 수리이방성은 층리면과 수평면이 이루는 각도를 $0^{\circ}$에서 $90^{\circ}$까지 $15^{\circ}$간격으로 코어링한 샘플을 제작하여 투수실험을 통해 파악하였다. 투수실험 결과 층리면과 투수방향이 수직인 경우 투수율이 가장 작은 값을 나타낸 반면, 층리면과 투수방향이 평행일 때 가장 높은 투수율을 나타내었으며, 평균 수리이등방비($k_{90^{\circ}}/k_{0^{\circ}}$)가 1.8로 층리에 따른 수리 이방성이 확연하게 나타났다. 또한, 이러한 사암의 수리이방특성은 층리에 의해 공극특성이 서로 다른 층상구조가 형성되기 때문임을 확인하였다.

ALOS-1 L-band PALSAR와 COSMO-SkyMed X-band SAR 시계열 영상을 이용한 도심지 변위관측 성능 비교 분석 (Comparison of Observation Performance of Urban Displacement Using ALOS-1 L-band PALSAR and COSMO-SkyMed X-band SAR Time Series Images)

  • 최정현;김상완
    • 대한원격탐사학회지
    • /
    • 제34권2_1호
    • /
    • pp.283-293
    • /
    • 2018
  • 본 연구에서는 두개의 SAR 위성(ALOS-1과 COSMO-SkyMed) 영상에 PSInSAR 기술을 적용하여 각기 다른 센서 특성에 따른 변위 관측 성능의 차이를 분석하였다. 수치지형도 레이어로부터 건물 레이어를 추출하여, SAR 위성 영상으로부터 추출된 PS를 건물구조물과 지표면에서 추출되는 PS로 분류하고 각각 밀도 분석을 수행하였다. 연구지역에서 추출된 PS의 밀도는 ALOS-1 PALSAR의 경우 $0.023point/m^2$, COSMO-SkyMed는 $0.1point/m^2$로 ALOS-1에 비해 4배 이상의 PS가 추출되었다. 또한, 건물에서의 PS 밀도뿐만 아니라 지면에서의 관측 밀도도 크게 증가하였다. ALOS-1 PALSAR의 평균 변위속도는 ${\pm}1cm/yr$ 이내의 값을 갖는 반면 COSMO-SkyMed의 경우 ${\pm}0.3cm/yr$ 이내의 매우 안정적인 값을 보이고 있다. 비록 동일 기간의 자료를 사용한 것이 아니기 때문에 정량적인 비교는 어렵지만, L-band에 비해 X-band SAR 시스템의 변위관측 정밀도가 매우 높다고 할 수 있다. X-band와 L-band SAR 영상 비교분석을 통해 지반침하, 싱크홀과 같이 도심지 지표면에서 유용한 신호를 획득하는 것이 중요한 연구에서 PS 관측 밀도 및 변위 관측 정밀도를 고려하였을 때 X-band SAR 자료가 매우 효과적이다.

이중 에너지 엑스레이 흡수기의 가동 시간에 따른 골밀도 값의 평가 (The Bone Mineral Density Value According to the Operating Time of the Dual Energy X-ray)

  • 이해정;김호성;김은혜
    • 핵의학기술
    • /
    • 제14권1호
    • /
    • pp.40-45
    • /
    • 2010
  • Purpose: Recently, the performance of the X-ray tube was very much improved by the power generation of the technology. However, the overload of equipment is occurred by the increment of the equipment operating time according to the increment of the examination number of cases. The X-ray dose can change by heat occurrence of the X-ray tube due to this. Moreover, the change of the bone mineral density value is possible to occur. Therefore, We tries to whether the change of the bone mineral density value of each equipment according to the difference of the examination number of cases and operating time occur or not. Materials and Methods: The BMD value was measured by the Aluminum Spine Phantom and the European Spine Phantom in each equipment, in order to find out about the difference of the time general classification bone mineral density value by using the Dual energy X-ray absorptiometry. And after scanning each phantom by using X-ray dose meter (Unfors Mult-O-Meter), a dose was measured by the same condition. As to, an average and standard deviation were found and the change of each equipment much BMD value was compared and it evaluated. Results: $Mean{\pm}SD$ of each equipment by using the Aluminum Spine Phantom, A equipment was $1.174{\pm}0.002$, $1.171{\pm}0.005$, $1.173{\pm}0.005$, B equipment was $1.186{\pm}0.003$, $1.187{\pm}0.003$, $1.185{\pm}0.003$, C equipment was $1.180{\pm}0.003$, $1.182{\pm}0.004$, $1.183{\pm}0.002$, D equipment was $1.188{\pm}0.004$, $1.185{\pm}0.003$, $1.185{\pm}0.004$. By using the European Spine Phantom, A equipment was $1.143{\pm}0.006$, $1.153{\pm}0.009$, $1.161{\pm}0.003$, B equipment was $1.134{\pm}0.004$, $1.13{\pm}0.008$, $1.127{\pm}0.015$, C equipment was $1.143{\pm}0.006$, $1.134{\pm}0.01$, $1.133{\pm}0.006$, D equipment was $1.14{\pm}0.001$, $1.122{\pm}0.002$, $1.131{\pm}0.008$, altogether included in the normal range. Conclusion: There was no significant change of the BMD value of using a phantom by time zones. Therefore, if the quality control is made to use the extent management method of the equipment for beginning in the present application, the reliability of the BMD equipment will be able to be enhanced.

  • PDF

MCNP 시뮬레이션을 통한 450 kVp 엑스레이 튜브의 콘크리트 차폐벽 두께 계산 및 반가층 방법을 이용한 계산과의 결과 비교 (Calculation of Concrete Shielding Wall Thickness for 450 kVp X-ray Tube with MCNP Simulation and Result Comparison with Half Value Layer Method Calculation)

  • 이상헌;허삼석;이은중;김찬규;조규성
    • 방사선산업학회지
    • /
    • 제10권1호
    • /
    • pp.29-35
    • /
    • 2016
  • Radiation generating devices must be properly shielded for their safe application. Although institutes such as US National Bureau of Standards and National Council on Radiation Protection and Measurements (NCRP) have provided guidelines for shielding X-ray tube of various purposes, industry people tend to rely on 'Half Value Layer (HVL) method' which requires relatively simple calculation compared to the case of those guidelines. The method is based on the fact that the intensity, dose, and air kerma of narrow beam incident on shielding wall decreases by about half as the beam penetrates the HVL thickness of the wall. One can adjust shielding wall thickness to satisfy outside wall dose or air kerma requirements with this calculation. However, this may not always be the case because 1) The strict definition of HVL deals with only Intensity, 2) The situation is different when the beam is not 'narrow'; the beam quality inside the wall is distorted and related changes on outside wall dose or air kerma such as buildup effect occurs. Therefore, sometimes more careful research should be done in order to verify the effect of shielding specific radiation generating device. High energy X-ray tubes which is operated at the voltage above 400 kV that are used for 'heavy' nondestructive inspection is an example. People have less experience in running and shielding such device than in the case of widely-used low energy X-ray tubes operated at the voltage below 300 kV. In this study, Air Kerma value per week, outside concrete shielding wall of various thickness surrounding 450 kVp X-ray tube were calculated using MCNP simulation with the aid of Geometry Splitting method which is a famous Variance Reduction technique. The comparison between simulated result, HVL method result, and NCRP Report 147 safety goal $0.02mGy\;wk^{-1}$ on Air Kerma for the place where the public are free to pass showed that concrete wall of thickness 80 cm is needed to achieve the safety goal. Essentially same result was obtained from the application of HVL method except that it suggest the need of additional 5 cm concrete wall thickness. Therefore, employing the result from HVL method calculation as an conservative upper limit of concrete shielding wall thickness was found to be useful; It would be easy, economic, and reasonable way to set shielding wall thickness.

저진공 펄스 직류 전원 BCl3 플라즈마의 전기적 특성과 GaAs의 식각 특성 분석

  • 이제원;박동균;노강현;신주용;조관식;손근용;송한정
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2011년도 제41회 하계 정기 학술대회 초록집
    • /
    • pp.137-137
    • /
    • 2011
  • 펄스 직류 $BCl_3$ 플라즈마의 전기적 특성과 GaAs의 건식식각을 연구하였다. 공정변수는 펄스 직류 전압 (350~550 V), 펄스 직류 주파수 (100~250 kHz), 리버스 시간 (0.4~1.2 ${\mu}s$)이었다. 전기적 특성은 오실로스코프를 이용하여 분석하였다. 펄스 직류 전원의 경우 평균 전압이 일정하더라도 주파수가 커지거나 리버스 시간이 커지면 peak-to-peak 전압이 증가한다는 사실을 이해하였다. GaAs 식각 실험 후 샘플의 식각률, 식각 선택비, 표면 형상을 비교, 분석하였다. GaAs의 식각 결과는 식각 속도, 식각 선택비, 표면 형상, 잔류 물질 분석을 실시하엿다. 본 실험에서는 1대의 기계적 펌프만을 상ㅇ하여 진공 압력을 유지하였다. GaAs의 식각 속도는 10 sccm $BCl_3$를 사용한 경우 최대 0.4 ${\mu}m$까지 얻을 수 있었다. 감광제에 대한 최대 식각 선택비는 약 2.5 : 1이었다. BCl3 플라즈마의 경우 75 mTorr의 저진공 조건에서는 500 V, 250 kHz, 0.7 ${\mu}s$의 실험에서 가장 좋은 식각 특성을 얻을 수 있엇다. X-레이 광전 분석기 데이터에 의하면, 식각된 GaAs의 표면을 깨끗하였으며, 염소와 관련된 잔류 물질은 거의 발견되지 않았다.

  • PDF

철계 복합 분말로 제조된 오버레이 용접층의 미세조직 및 특성 (Microstructure and Characterization of Overlay Welding Layer using Fe-based Composite Powders)

  • 민홍;이종재;이진규
    • 한국분말재료학회지
    • /
    • 제26권3호
    • /
    • pp.214-219
    • /
    • 2019
  • In this study, the microstructure and characterization of an overlay welding layer using Fe-based composite powders are reported. The effects of the number of passes and composition of powders on the microstructure and mechanical properties are investigated in detail. The welding wire and powders are deposited twice on a stainless-steel rod using a laser overlay welding process. The microstructure and structural characterization are performed by scanning electron microscopy and X-ray diffraction. The mechanical properties of the first and second overlay layers are analyzed through the micro-Vickers-hardness tester and abrasion wear tester. In the second overlay layer, the hardness and specific wear are approximately 840 Hv and $2.0{\times}10^{-5}mm^3/Nm$, respectively. It is suggested that the increase of the volume fractions of $(Cr,Fe)_7C_3$ and NbC phases in the second welding layer enhances the hardness and wear resistance.

Intra Oral CMOS X-ray Image Sensor용 DC-DC 변환기 설계 (Design of a DC-DC converter for intra-oral CMOS X-ray image sensors)

  • 장지혜;김려연;허성근;;김태우;하판봉;김영희
    • 한국정보통신학회논문지
    • /
    • 제16권10호
    • /
    • pp.2237-2246
    • /
    • 2012
  • 본 논문에서는 구강센서를 소형화하고 제조 원가를 낮추기 위해 구강센서에서 필요로 하는 바이어스 회로를 구강센서 칩 내부에서 만들어주었다. 제안된 DC-DC 변환기 회로는 기준전류 발생기(reference current generator) 회로의 IREF를 이용하여 전압 레귤레이터(voltage regulator)에 필요한 기준전류와 바이어스 전류를 각각 공급해준다. 이들 전류가 각각의 전압 레귤레이 회로에서 해당되는 기준전압을 생성하여 부궤환(negative feedback)에 의해 목표전압을 regulation하게 된다. 그리고 기준전류가 전류 복사비(current mirror ratio)에 의해 mirroring되어 정전류인 IB0/IB1을 공급해주고, VREF 전압을 공급해주도록 설계하였다. $0.18{\mu}m$ X-ray CMOS 이미지 센서 공정을 이용하여 설계된 구강센서의 DC-DC 변환기의 출력 전압의 평균 전압, ${\sigma}$$4{\sigma}$는 양호한 측정 결과를 얻었다. 그리고 line-pair pattern 영상은 blurring 없이 높은 해상도 특성을 보였으며, 좋은 구강 영상을 획득하였다.