• Title/Summary/Keyword: X-대역

Search Result 400, Processing Time 0.023 seconds

A Study on the Phase-looked Dielectric Resonator Oscillator using Bias Tuning (바이어스 동조를 이용한 위상 고정 유전체 공진 발진기에 관한 연구)

  • 류근관;이두한;홍의석
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.19 no.10
    • /
    • pp.1982-1990
    • /
    • 1994
  • We implemented a PLDRO(Phase Locked Dielectric Resonator Oscillator) using the concept of the feedback property of PLL(Phase Locked Loop) for Ku-band(10.95-11.70 GHz). The conventional approaches to a PLDRO design use varactor diode tuning method.. But in theis paper, the PLDRO has the advantage of the frequency sensitivity to changes in the supple voltage of the oscillating device without the frequency-variable part by varactor diode voltage-control. and uses a SPD(Sampling Phase Detector) for phase-comparision. The PLDRO is composed of the DRO phase-locked to the reference signal of UHF band by using a SPD for high frequency stability and can be available for European FSS(Fixed Satellite Service) at 10.00GHz. The PLDRO generates the output power of 8.67 dBm at 10.00 GHz and has a phase noise of -81 dBc/Hz at 10 kHz offset from carrier. The hamonic and spurious characteristics have -42.33 dBc and -65dBc respectively. This PLDRO has much better frequency stability, lower phase noise, and more economical effect for a satellite system than conventional DRO.

  • PDF

A Design and Construction of Phase-locked Dielectric Resonator Oscillator for VSAT (VSAT용 위상고정 유전체 공진 발진기의 설계 및 구현)

  • 류근관;이두한;홍의석
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.19 no.10
    • /
    • pp.1973-1981
    • /
    • 1994
  • A PLDRO(Phase Locked Dielectric Resonator Oscillator) in Ku-band(10.95-11.70GHz) is designed with the concept of the feedback property of PLL(Phase Locked Loop). A series feedback type DRO is developed, and VCDRO(Voltage Controlled Dielectric Resonator Oscillator) using a varactor diode as a voltage-variable capacitor is implemented to tune oscillating frequency electrically. Then, PLDRO is designed by using a SPD(Sampling Phase Detector). This PLDRO is phase-locked voltage controlled DRO to reference source(VHF band) by SPD at 10.00 GHz for European FSS(Fixed Satellite Service). The PLDRO generates output power greater than 10dBm at 10.00 GHz and has phase noise of -80 dBc/Hz at 10 KHz offset from carrier. This PLDRO achieves much better frequency stability than conventional VCDRO.

  • PDF

Development of 400MHz Wide-Band Correlation Board for Radio Astronomy Spectrometer (전파천문관측용 400MHz 광-대역 상관기 보드의 설계 및 제작)

  • Lee, Chang-hoon;Park, Han-Kyu;Kim, Kwang-Dong;Koo, Bon-Chul;Byun, Do-Young;Han, Seog-Tae;Kim, Tae-Sung
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.41 no.2
    • /
    • pp.37-44
    • /
    • 2004
  • In this paper, we performed the design and the development of the wide-band correlation board to be an important role in the autocorrelation spectrometer's building for the observation study of an extra-galaxy's spectral lines and the survey research of the special radio sources in field of the radio astronomy. In this research, the developed correlation board by using QUAINT correlator chip(made by NRAO) has maximum 100 MHz clock speed and operate at a intermediate frequency with 400 MHz bandwidth. For the Performance test we supply the 0.5 and 1.67 MHz rectangular wave, then we obtain the autocorrelation coefficients. The final results, which process by using FFT, get the almost same results compare with the theoretical correlation.

A Study on the Fabrication of 1W Power Amplifier for IMT2000 Repeater Using Nonlinear Analysis (비선형 해석법을 이용한 IMT2000 중계기용 1W 전력증폭기 제작 연구)

  • 전광일
    • Journal of the Institute of Electronics Engineers of Korea TE
    • /
    • v.37 no.2
    • /
    • pp.83-90
    • /
    • 2000
  • A simple low-cost and small size 1.88-198 GHz Band RF power amplifier module is developed for IMT2000 repeater. The power amplifier consists of two stage amplifiers that the first stage amplifier is drive amplifier using discrete type P-HEMT (ATF-34143, 800 micron gate width, Agilent Technologies) and the second is power amplifier with 300Bm 1dB gain compression point using GaAs FET(EFA240D-SOT89, 2400 micron gate width, Excelics Semiconductor). this power amplifier module feature a 29.5dBm 1dB gain compression point, 29.5dB gain, 42dBm 3rd order intercept point(OIP3) and -10dB/-l2dB input/output return loss over the 1880-1980 MHz. This PA module is fully integrated using MIC technology into a small size and design by full nonlinear design technologies. The dimensions of this PA module are 42(L) $\times$ 34(W) mm.

  • PDF

양자점을 이용한 808 nm 파장대역의 고출력 레이저 칩 개발

  • O, Hyeon-Ji;Park, Seong-Jun;Kim, Min-Tae;Kim, Ho-Seong;Song, Jin-Dong;Choe, Won-Jun;Myeong, Jae-Min
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2012.05a
    • /
    • pp.87.2-87.2
    • /
    • 2012
  • 고출력 반도체 레이저 다이오드는 발진 파장 및 광 출력에 따라 다양한 분야에 응용되고 있으며, 특히 발진파장이 808 nm 및 1470 nm 인 고출력 레이저 다이오드의 경우 재료가공, 펌핑용 광원 (DPSSL, 광섬유 레이저), 의료, 피부미용 (점 제거), 레이저 다이오드 디스플레이 등 가장 다양한 응용분야를 가진 광원 중의 하나라고 할 수 있다. 일례로 재료가공의 경우, 레이저 용접, 레이저 인쇄, 하드디스크의 레이저 텍스쳐링 등 그 응용분야는 무수히 많으며, 최근에는 미래 성장동력 사업의 하나로 중요한 이슈가 되는 태양전지에서 에지 분리 (edge isolation), ID 마킹, 레이저 솔더링 등에서 필수불가결한 광원으로 각광받고 있다. 808 nm 대역 In(Ga)AlAs quantum dots laser diode (QDLD) 성장을 위하여 In(Ga)AlAs QD active 와 In(Ga)AlAs QD LD 성장으로 크게 분류하여 여러 가지 test 실험을 수행하였다. 우선 In(Ga)AlAs QD LD 성장에 앞서 high power LD에 적용 가능한 GaAs/AlGaAs quantum well의 성장 및 전기 측정을 수행하여 그 가능성을 보았다. In(Ga)AlAs QD active layer의 효과적인 실험 조건 조절을 위해 QD layer는 sequential mithod (ex. n x (InGaAlAs t sec + InAs t sec + As 10 sec)를 사용하였다. In(Ga)AlAs QD active layer는 성장 온도, 각 sequence 별 시간, 각 source 양, barrier 두께 조절 및 타입변형, Arsenic flux 등의 조건을 조절하여 실험하였다. 또한 위에서 선택된 몇 가지 active layer 를 이용하여 In(Ga)AlAs QD LD 성장 조건 변화를 시도하였다.

  • PDF

A Study of Call Admission Scheme using Power Strength Threshold value between APs in Wireless LAN Environments (무선랜 환경에서 AP간 전력임계치값을 통한 호 처리 연구)

  • Lim, Seung-Cheol
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.15 no.3
    • /
    • pp.107-112
    • /
    • 2015
  • A smart phone and the number of wireless terminals are mobile-to the nature of the AP mobility are many call transfer between wireless terminals and AP (Access Point). Each wireless terminal that is the call processing process for each is relatively large to cause the wireless traffic, and a factor that inhibits the efficient use of the radio band on the AP. In this paper, we use the power intensity threshold and threshold timer of the AP received by the mobile station to reduce the amount of switching traffic between the AP's cause and traffic generation factors between the wireless device and the AP that can effectively utilize the radio traffic from the AP the measures proposed. The proposed method and the conventional method is improved by simulation to handle the amount of radio traffic from the AP it was confirmed that it is possible to effectively utilize the whole of the radio band.

The Ultrasonic Image Processing by Peak Value, Time Average and Depth Profile Technique in High Frequency Bandwidth (고주파대역에서 피크값, Time Average 및 Depth Profile 초음파 영상처리)

  • 이종호
    • Journal of the Korean Institute of Telematics and Electronics T
    • /
    • v.35T no.3
    • /
    • pp.120-127
    • /
    • 1998
  • In this paper, ultrasonic images of 25MHz bandwidth were acquired by applying peak value variation, time average and depth profile algorithm to acoustic microscopy and its performance was compared and analysed with each other. In the time average algorithm, total reflecting pulse wave from a spot on the coin was converted to digital data in time domain and average value of the converted 512 data was calculated in computer. Time average image was displayed by gray levels colour of acquired N x N matrix average data in the scanning area on the sample. This technique having smoothing effects in time domain make developed an ultrasonic image on a highly scattering area. In depth profile technique, time difference between the reference and the reflected signal was detected with minimum resolution performance of 2ns, thus we can acquired real 3 dimensional shape of the scanning area in accordance with relative magnitude. Through these experiments, peak value, time average and depth profile images were analysed and advantages of each algorithm were proposed.

  • PDF

Uniform Slot Width Bow-tie-shaped Meander Slot Antenna for 5 GHz Application (균일한 슬롯 폭을 갖는 5 GHz 대역 보우타이 형태의 미앤더 슬롯 안테나)

  • 위상혁;김정민;유태훈;육종관;박한규
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.13 no.8
    • /
    • pp.769-776
    • /
    • 2002
  • In this paper, we propose uniform slot width bow-tie-shaped meander slot antenna for 5 GHz application. The conventional bow-tie slot antenna has broadband characteristic, however, its size is large. Meanwhile, the meander slot antenna has small size, but it has quite narrow bandwidth. The proposed antenna geometry is a variation of the meander slot antenna incorporating bow-tie shape to realize miniaturized antenna having relatively large bandwidth. Simulated results show that with the same slot width and total slot length, the bandwidth of the proposed antenna is 3 times wider than that of meander slot antenna, and its resonant frequency is 3.01 GHz lower than that of the equal size(H x V) bow-tie slot antenna, and measured results show that the bandwidth of proposed antenna is 218 MHz(5.142 GHz ~ 5.360 GHz) which satisfy the required bandwidth from 5.15 GHz to 5.35 GHz.

A Dual-Band Asymmetrical Metamaterial Antenna for Orthogonal Radiation Patterns (수직한 방사패턴을 형성하는 이중대역 비대칭 배열 메타물질 안테나)

  • Pyo, Seong-Min;Han, Sang-Min;Lee, Dong-Hyo;Kim, Young-Sik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.9
    • /
    • pp.2246-2252
    • /
    • 2009
  • A new metamaterial antenna with dual resonant modes is presented using an asymmetrical periodic arrangement for orthogonal radiation patterns. The proposed antenna produces two orthogonal modes by the asymmetrical periodic unit-cell arrangement. The orthogonal resonant mode provides perpendicular radiation patterns without changing the antenna polarization at each resonant mode. The fabricated antenna shows good agreements with the theoretical analysis of the electric-field. The experimental results shows the orthogonal radiation patterns along x- and y-axises, and gains are 3.34 and 3.86 dBi at each radiating resonant mode, respectively. Additionally, slotted ground structures are embedded on the back side of the antenna in order to reduce the size and enhance the radiation efficiency of 12 % and 27 %, respectively.

Acquisition of Monochromatic X-ray using Graded Multilayer Mirror (Graded 다층박막거울을 이용한 단색 엑스선 획득)

  • Ryu, Cheolwoo;Choi, Byoungjung;Son, Hyunhwa;Kwon, Youngman;Kim, Byoungwook;Kim, Youngju;Chon, Kwonsu
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.4
    • /
    • pp.205-211
    • /
    • 2015
  • At a recent medical imaging technology, the major issue of X-ray diagnosis in breast cancer is the early detection of breast cancer and low patient's exposure dose. As one of studies to acquire a monochromatic X-ray, Technologies using multilayer mirror had been preceded. However, a uniform multilayer mirror that consists of uniform thin-film thickness can acquire a monochromatic X-ray only in the partial area corresponds to angle of incidence of white X-ray, so there are limits for X-ray imaging technology applications. In this study, we designed laterally graded multilayer mirror(below GML) that reflects same monochromatic X-ray over the entire area of thin-film mirror, which have the the thickness of the linear gradient that correspond to angle of incidence of white X-ray. By using ion-beam sputtering system added the mask control system we fabricated a GML which has size of $100{\times}100mm^2$. The GML is designed to achieve the monochromatic X-ray of 17.5kev energy and has thin-film thickness change from 4.62nm to 6.57nm(3.87nm at center). It reflects the monochromatic X-ray with reflectivity of more than 60 percent, FWHM of below 2.6keV and X-ray beam width of about 3mm. The monochromatic X-ray corresponded to 17.5keV using GML would have wide application in development of mammography system with high contrast and low dose.