• 제목/요약/키워드: X rays

검색결과 782건 처리시간 0.026초

시경반하탕가미를 포함한 한방치료를 항생제 치료와 병용하여 호전된 뇌경색 환자의 반복되는 흡인성 폐렴 치험 1례 (Case Study of a Cerebral Infarction Patient with Recurring Aspiration Pneumonia Treated with Korean Medicine, Including Shigyungbanha-tang-gami Combined with Antibiotics)

  • 양지수;조은채;유재환
    • 대한한방내과학회지
    • /
    • 제44권2호
    • /
    • pp.97-106
    • /
    • 2023
  • Objective: This study addressed the case of a cerebral infarction patient with recurring aspiration pneumonia. Methods: A patient diagnosed with cerebral infarction with recurring aspiration pneumonia was treated with Korean medicine therapies, including herbal medication (Shigyungbanha-tang-gami), acupuncture, electro-acupuncture, and moxibustion combined with antibiotics for 31 days. To evaluate the therapeutic effect, we checked chest X-rays, lab evaluations, the number of night suctions, and body temperature. Results: After treatment, chest X-rays and inflammation markers improved. In addition, the number of night suctions decreased, and the body temperature was normalized. Aspiration pneumonia recurred. However, the intensity of the symptoms gradually weakened, and the recovery speed increased. Conclusion: These results suggest that Korean medicine therapies, including Shigyungbanha-tang-gami combined with antibiotics, have a beneficial effect on recurring aspiration pneumonia, an additional disease related to cerebral infarction.

Synthesis, physical, optical and radiation shielding properties of Barium-Bismuth Oxide Borate-A novel nanomaterial

  • B.M. Chandrika;Holaly Chandrashekara Shastry Manjunatha;K.N. Sridhar;M.R. Ambika;L. Seenappa;S. Manjunatha;R. Munirathnam;A.J. Clement Lourduraj
    • Nuclear Engineering and Technology
    • /
    • 제55권5호
    • /
    • pp.1783-1790
    • /
    • 2023
  • Barium Bismuth Oxide Borate (BBOB) has been synthesized for the first time using solution combustion technique. SEM analysis reveal flower shape of the nanoparticles. The formation of the nanoparticles has been confirmed through XRD & FTIR studies which gives the physical and chemical structure of the novel material. The UV light absorption is observed in the range 200-300 nm. The present study highlights the radiation shielding ability of BBOB for different radiations like X/Gamma rays, Bremsstrauhlung and neutrons. The gamma shielding efficiency is comparable to that of lead in lower energy range and lesser than lead in the higher energy range. The bremsstrauhlung exposure constant is comparably larger for BBOB NPs than that of concrete and steel however it is lesser than that of lead. The beauty of BBOB nanoparticles lies in, high absorption of radiations and low emission of secondary radiations when compared to lead. In addition, the neutron shielding parameters like scattering length, absorption and scattering cross sections of BBOB are found to be much better than lead, steel and concrete. Thus, BBOB nanoparticles are highly efficient in absorbing X/Gamma rays, neutrons and bremsstrauhlung radiations.

MONTE CARLO SIMULATION OF COMPTONIZATION IN A SPHERICAL SHELL GEOMETRY

  • SEON KWANG IL;MIN KYOUNG WOOK;CHOI CHUL SUNG;NAM UK WON
    • 천문학회지
    • /
    • 제27권1호
    • /
    • pp.45-53
    • /
    • 1994
  • We present the calculation of X -ray spectra produced through Compton scattering of soft X-rays by hot electrons in the spherical shell geometry, using fully relativistic Monte Carlo simulation. With this model, we show that the power-law component, which has been observed in the low luminosity state of low-mass X-ray binaries (LMXBs), is explained physically. From a spectral. analysis, we find that spectral hardness is mainly due to the relative contribution of scattered component. In addition, we see that Wi en spectral features appear when the plasma is optically thick, especially in the high energy range, $E{\gtrsim}100keV$. We suggest that after a number of scattering the escape probability approaches an asymptotic form depending on the geometry of the scattering medium rather than on the initial photon spectrum.

  • PDF

X-RAY ARCHIVAL DATA ANALYSIS OF TIME VARIABILITIES IN SEYFERT GALAXY MCG-2-58-22

  • CHOI CHUL-SUNG;DOTANI TADAYASU;YI INSU;FLETCHER ANDRE;KIM CHULHEE
    • 천문학회지
    • /
    • 제34권3호
    • /
    • pp.129-135
    • /
    • 2001
  • We report results from an analysis of the X-ray archival data on MCG-2-58-22 obtained with Ginga, ROSAT and ASCA. By analyzing both short- and long-term light curves, we find clear time variations, ranging widely from, $\~10^3$ s to more than several years, in the X-ray energy range 0.1 - 10 keV. In addition, a flare is detected in 1991, overlaid on a gradual, secular flux decrease from 1979 to 1993; this flare has a time scale of about 1 year, and the X-ray flux increased by at least a factor of 3. The implications of these observational results are discussed in terms of accretion flow dynamics near a supermassive black hole.

  • PDF

Trial of Computer Simulation of Image Reconstruction from Incomplete Data for New CT with Reduced Exposure

  • Hayakawa, Yoshinori;Furuya, Toshimitsu;Sakakibara, Norifumi
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.382-384
    • /
    • 2002
  • Filtered-Back-Projection technique is used in X-ray CT image reconstruction. This requires X-ray transmission data from all directions. As the transverse cross-section of the body is approximately 50 cm, transmitted X-rays in this direction are strongly attenuated. If X-ray transmission data in this direction is avoided, exposure to the patients seems to be reduced one 20th of usual value. Some alternative method has to be found for clinically sufficient image quality. New methods are under development and tentative results are reported that utilizes the principle of superposition.

  • PDF

DETECTION OF X-RAY EMISSION FROM GALAXIES INSIDE AND TOWARDS THE NEARBY VOIDS

  • KIM CHULHEE;BOLLER TH.;GHOSH KAJAL K.
    • 천문학회지
    • /
    • 제38권1호
    • /
    • pp.1-6
    • /
    • 2005
  • We searched for X-ray emission from the 665 galaxies inside and towards the nearby voids by analyzing the ROSAT All-Sky Survey (RASS) data as well as the ROSAT pointed observations (PSPC). As a result we have detected six X-ray emitting galaxies. Two (UGC 10205 and NGC 7509) are in the high density region in the local void, three (UGC 749, MCG +11-10-073, and Mrk 464) are towards the nearby voids, and UGC 32 is located in the low density region. We carried out a timing analysis for both Mrk 464 and UGC 32, and a spectral analysis for Mrk 464. The light curve of Mrk 464 shows the possibility of periodic X-ray flux variation and UGC 32 shows weak, but rapid variation.

Basic Physical Principles and Clinical Applications of Computed Tomography

  • Jung, Haijo
    • 한국의학물리학회지:의학물리
    • /
    • 제32권1호
    • /
    • pp.1-17
    • /
    • 2021
  • The evolution of X-ray computed tomography (CT) has been based on the discovery of X-rays, the inception of the Radon transform, and the development of X-ray digital data acquisition systems and computer technology. Unlike conventional X-ray imaging (general radiography), CT reconstructs cross-sectional anatomical images of the internal structures according to X-ray attenuation coefficients (approximate tissue density) for almost every region in the body. This article reviews the essential physical principles and technical aspects of the CT scanner, including several notable evolutions in CT technology that resulted in the emergence of helical, multidetector, cone beam, portable, dual-energy, and phase-contrast CT, in integrated imaging modalities, such as positron-emission-tomography-CT and single-photon-emission-computed-tomography-CT, and in clinical applications, including image acquisition parameters, CT angiography, image adjustment, versatile image visualizations, volumetric/surface rendering on a computer workstation, radiation treatment planning, and target localization in radiotherapy. The understanding of CT characteristics will provide more effective and accurate patient care in the fields of diagnostics and radiotherapy, and can lead to the improvement of image quality and the optimization of exposure doses.

Spectral Computed Tomography: Fundamental Principles and Recent Developments

  • Aaron So;Savvas Nicolaou
    • Korean Journal of Radiology
    • /
    • 제22권1호
    • /
    • pp.86-96
    • /
    • 2021
  • CT is a diagnostic tool with many clinical applications. The CT voxel intensity is related to the magnitude of X-ray attenuation, which is not unique to a given material. Substances with different chemical compositions can be represented by similar voxel intensities, making the classification of different tissue types challenging. Compared to the conventional single-energy CT, spectral CT is an emerging technology offering superior material differentiation, which is achieved using the energy dependence of X-ray attenuation in any material. A specific form of spectral CT is dual-energy imaging, in which an additional X-ray attenuation measurement is obtained at a second X-ray energy. Dual-energy CT has been implemented in clinical settings with great success. This paper reviews the theoretical basis and practical implementation of spectral/dual-energy CT.

Production of clothes for beach volleyball players: Safe against ultraviolet radiation damage

  • He Huang
    • Geomechanics and Engineering
    • /
    • 제32권6호
    • /
    • pp.627-637
    • /
    • 2023
  • Volleyball is an international sport with many fans. This sport has made significant progress in schools and clubs. Volleyball is suitable for all age groups and can be used in different environments. It has many social and physical benefits. During the game provides special physical training for the players and is considered one of the most exciting games. Another type of volleyball is beach volleyball, a beach sport and one of the Olympic sports held on the sand with the same rules as volleyball. This sport is usually played in coastal areas, especially with wide sandy beaches. Because this sport is played in open spaces, the players stay in this space for a long time and are exposed to dangerous ultraviolet radiation. It is a wavelength of light in the range of electromagnetic waves with a wavelength between 10 and 400 nm. This wavelength is shorter than visible light and more protracted than X-ray. Ultraviolet (UV) rays are naturally present in sunlight and include about 10% of all waves emitted from the sun's surface. Prolonged exposure to ultraviolet light causes acute and chronic damage to the skin and vision and even destroys the entire immune system. Different covers of the earth's surface reflect different amounts of UV rays. For example, snow cover, sand, and seawater surface reflect this radiation. Therefore, the health of volleyball players is in danger due to this harmful radiation. This work aims to introduce a type of clothing made of nanoparticles that can repel ultraviolet rays and protect beach volleyball players whose health is at risk from this radiation.

LIGA 공정에서의 노광시간과 X선마스크 흡광체의 두께 (Exposure Time and X-Ray Absorber thickness in the LIGA Process)

  • 길계환;이승섭;염영일
    • 한국진공학회지
    • /
    • 제8권2호
    • /
    • pp.102-110
    • /
    • 1999
  • The LIGA X-ray exposure step was modelled into three inequalities, by assuming that the X-ray energy attenuated within a resist is deposited only in the localized range of the resist. From these inequalities, equations for the minimum and maximum exposure times required for a good quality microstructure were obtained. Also, an equation for the thickness of an X-ray mask absorber was obtained from the exposure requirement of threshold dose deposition. The calculation method of the synchrotron radiation power from a synchrotron radiation source was introduced and applied to an X-ray exposure step. A power from a synchrotron radiation source was introduced and applied to an X-ray exposure step/ A power function of photon energy, approximating the attenuation length of the representative LIGA resist, PMMA, and the mean photon energy of the XZ-rays incident upon an X-ray mask absorber were applied to the above mentioned equations. Consequently, the tendencies of the minimum and maximum exposure and with respect to mean photon energy and thick ness of PMMA was obtained. Additionally, the tendencies of the necessary thickness of PMMA and photon energy of the X-ray mask absorber with respect to thickness of PMMA and photon energy of the X-rays incident upon an X-ray mask absorber were examined. The minimum exposure time increases monotonically with increasing mean photon energy for the same total power density and is not a function of the thickness of resist. The minimum exposure time increases with increasing mean photon energy for the same total power density in the case of the general LIGA process, where the thickness of PMMA is thinner than the attenuation length of PMMA. Additionally, the minimum exposure time increases monotonically with increasing thickness of PMMA. The maximally exposable thickness of resist is proportional to the attenuation length of the resist at the mean photon energy with its proportional constant of ln $(Dd_m/D_{dv})$. The necessary thickness of a gold X-ray mask absorber due to absorption edges of gold, increases smoothly with increasing PMMA thickness ratio, and is independent of the total power density itself. The simplicity of the derived equations has made clearly understandable the X-ray exposure phenomenon and the correlation among the exposure times, the attenuation coefficient and the thickness of an X-ray mask absorber, the attenuation coefficient and the thickness of the resist, and the synchrotron radiation power density.

  • PDF