Distribution of X-ray Strength in Exposure Field Caused by Heel Effect (양극의 경사각 효과에 따른 조사야 X-선 강도 분포)

  • Jang, Keun-Jo;Kim, Nam-Hun;Lee, Jun-Haeng;Lee, Sang-Bock
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.5
    • /
    • pp.223-229
    • /
    • 2011
  • When negative electron in x-ray tube is accelerated in to a high speed and then the currency of the electron is blocked by the target, x-ray happens by the conversion of the energy. The real area where the fast accelerated electron collides to a target area is called actual focal spot. When the string focused size is observed at the central ray side, where the direction x-ray comes out, the size seems to be reduced. This focus is called effective focal spot. According to radiation angle of x-rays tube, the degree of the negative pole side presents higher value than inclination, the amount of exposed radiation that patient receives differs by the angle of positive pole, which means effective focal spot is the variable. This paper presents the correlation between size of effective focal spot and amount of exposed radiation to the patient by it, and effective research for homogenized dose dispersion by the size of effective focal spot. In conclusion, following the focal size, effective range which was -8cm ~ 0 cm on average, was found and average dose rate was 0.019 R/min. Through this range, for patients with small radiation exposure, image with good density and resolution in aspect of diagnosing will be able to be obtained.

Physical Properties of Heavy Elements as Filter in Diagnostic Radiology (진단방사선영역에서 중원소 여과판의 물리적 특성)

  • Kim, Y.K.;Lee, K.S.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07d
    • /
    • pp.1977-1979
    • /
    • 1999
  • This work characterized in terms of the physical properties of heavy elements as reduction filter in the diagnostic radiology. From the results of experimental evaluation, it was founded that in the case of the Ho filter, the variety of X-ray property with kVp was less than those of Ba, Cu and Al. And the ratio of transit-dose to surface and the load of X-ray tube were increased in the order of Al, Ba, Cu and Ho. The contrast of X-ray image showed the higher value in the order of Cu, Al, Ba and Ho.

  • PDF

Non Dosimetry Measurements Use for Patients Safety : NDD-M (환자 안전을 위한 비 계측 선량측정의 활용 : NDD-M)

  • Gil, Jong-Won;Seon, Jong-Ryoul;Song, Wol-Su
    • Journal of the Korea Safety Management & Science
    • /
    • v.18 no.1
    • /
    • pp.141-145
    • /
    • 2016
  • This study was to improve to utilization of non dosimetry measurements for X-ray radiography. Experiments was passed off varying the X-ray tube voltage and the thickness of the aluminum filter by actual dose. Calculated results was set to the first beam quality factors, calculated first correction coefficient by the Microsoft Excel program was set as the second beam quality factors. To make the non dosimetry measurements simply, the Excel program apply to the new beam quality factors, the error was compared to the previous studies, and the results verify the calculated value of smaller errors.

Contrast Enhancement for Defects Extraction from Seel-tube X-ray Images (결함추출을 위한 강판튜브 엑스선 영상의 명암도 향상)

  • Hwang, Jung-Won;Hwang, Jae-Ho
    • Proceedings of the IEEK Conference
    • /
    • 2007.07a
    • /
    • pp.361-362
    • /
    • 2007
  • We propose a contrast-controlled feature detection approach for steel radiograph image. X-ray images are low contrast, dark and high noise image. So, It is not simple to detect defects directly in automated radiography inspection system. Contrast enhancement, histogram equalization and median filter are the most frequently used techniques to enhance the X-ray images. In this paper, the adaptive control method based on contrast limited histogram equalization is compared with several histogram techniques. Through comparative analysis, CLAHE(contrast controlled adaptive histogram equalization) can enhance detection of defects better.

  • PDF

X-Ray Emission Spectroscopic Analysis for Crystallized Amorphous Silicon Induced by Excimer Laser Annealing

  • John, Young-Min;Kim, Dong-Hwan;Cho, Woon-Jo;Lee, Seok;Kurmaev, E.-Z.
    • Journal of the Optical Society of Korea
    • /
    • v.5 no.1
    • /
    • pp.1-4
    • /
    • 2001
  • The results of investigating $SiL_{2,3}$/ X-ray emission valence spectra of amorphous silicon films irradiated by excimer laser are presented. It is found that laser annealing leads to crystallization of amorphous silicon films and the crystallinity increases with the laser energy density from 250 to 400 mJ/$\textrm{cm}^2$. The vertical structure of the film is investigated by changing the accelerating voltage on the X-ray tube, and the chemical and structural state of Si$_3$N$_4$ buffer layer is found not to be changed by the excimer laser treatment.

An Iterative Method for Flat-Field Correction of Digital Radiography When Detector is at Any Position (반복적인 방법을 이용한 임의의 DR detector 위치에서의 flat field correction 방법 연구)

  • Kim, Do-Il;Lee, Hyoung-Koo;Kim, Sung-Hyeon;Park, Dae-Sop;Choe, Bo-Young;Suh, Tae-Suk
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2004.11a
    • /
    • pp.64-66
    • /
    • 2004
  • When examing patients with DRs it is necessary to remove bad pixels and lines and to correct non-uniform offsets and x-ray field. For non-uniformity correction a flat field x-ray image is needed, and to obtain it the center of detector is usually aligned with the focal spot of the x-ray tube, which is conserved when examing patients to preserve the flat field. In some of radiographic techniques, however, it is necessary to move the x-ray tube off the center position of detector or tilt the detector. We investigated the effect of detector tilting on the non-uniformity correction, and propose a method to reduce the effect using a new algorithm. The flat field of X-ray in the DR detector could be guaranteed with this result.

  • PDF

The Relationship of the Filtration and the Side-scattered Dose in Verious Radiation Shielding Materials (방사선차폐물질(放射線遮蔽物質)에서 발생(發生)하는 측방산란선(側方散亂線)의 측정(測定))

  • Huh, Joon;Kim, Chang-Kyun
    • Journal of radiological science and technology
    • /
    • v.7 no.1
    • /
    • pp.35-40
    • /
    • 1984
  • Side-direction scattered dose from various radiation shielding materials was measured at 50cm distance from the central beam of primary ray by used several kinds of added filters for a x-ray deep therapeutic installation, the obtained results were as follows : 1. Dose rate by tube voltage was more increased at heavy filtration than light filtration. 2. Scattered doses produced by constant tube voltage in all shielding materials were decreased at heavier filtration. 3. Scattered doses produced by constant shielding material in all tube voltages were decreased at heavier filtration.

  • PDF

Misinterpretation of a skin fold artifact as pneumothorax on the chest x-ray of a trauma patient in Korea: a case report

  • Yoojin Park;Eun Young Kim;Byungchul Yu;Kunwoo Kim
    • Journal of Trauma and Injury
    • /
    • v.37 no.1
    • /
    • pp.86-88
    • /
    • 2024
  • Misinterpreting radiographic findings can lead to unnecessary interventions and potential patient harm. The urgency required when responding to the compromised health of trauma patients can increase the likelihood of misinterpreting chest x-rays in critical situations. We present the case report of a trauma patient whose skin fold artifacts were mistaken for pneumothorax on a follow-up chest x-ray, resulting in unnecessary chest tube insertion. We hope to help others differentiate between skin folds and pneumothorax on the chest x-rays of trauma patients by considering factors such as location, shape, sharpness, and vascular markings.

Fabrication and Characteristics of X-ray Position Detection Sensor (방사선 위치 검출센서의 제작 및 특성)

  • Park, Hyung-Jun;Kim, In-Su
    • Journal of IKEEE
    • /
    • v.19 no.4
    • /
    • pp.535-540
    • /
    • 2015
  • A microstrip gas chamber (MSGC), applied to digital radiography system, was designed and constructed. The microstrip electrodes were fabricated with Chrome(Cr.). by photolithography process on Silicon(Si) wafer and glass substrate. The width of anode and cathode electrodes was $10{\mu}m$, and $290{\mu}m$, respectively. The distance of the electrodes was $100{\mu}m$, and the active area was $50{\times}50mm^2$. And the number of anode was 80. The microstrip electrodes were damaged when discharges occurred over the 600 V of anode voltage. As the result of experiments. It detected the typical output signals of the pulse width, 20 ns, under the condition that the detecting gas was Ar(90%) + $CH_4$(10%), X-ray tube voltage was 42 kV, and tube current was 1 mA.

A Comparative Experiments for Tube Agglutination Test of Pullorum Antiserum with gamma-Ray 60Co Irradiated Salmonella pullorum (방사성동위원소(放射性同位元素)로 처리(處理)한 추백리균(雛白痢菌)의 응집반응(凝集反應)에 대한 비교시험(比較試驗))

  • Seo, Boo Kap
    • Korean Journal of Veterinary Research
    • /
    • v.16 no.1
    • /
    • pp.7-10
    • /
    • 1976
  • An agglutinability between naturally infected positive chicken serum of pullorum disease and hyperimmumized rabbit antiserum was compared. And the following results were obtained and summarized. 1. On the agglutinability, Salmonella pullorum antigen which irradiated gamma-ray was more excellent than another both formalized and heated antigen. 2. Time of judgemented as positive titer in the tube agglutination test to the naturally infected positive chicken serum was it most suitable for 12 hours at $37^{\circ}C$. 3. Agglutination titer of positive immune chicken serum against gamma-ray irradiate Salmonella pullorum were as 320~640x.

  • PDF