Suggestion of Modified Y-View in Supine Position (Supine Position에서 Modified Y-View의 제안)

  • Shin, Seong-Gyu;Baek, Seong-Min;Lee, Hyo-Yeong
    • Journal of radiological science and technology
    • /
    • v.35 no.2
    • /
    • pp.103-107
    • /
    • 2012
  • This study was performed to design a modified Y-View as an imaging method for the Y-View in supine position for patients who requires Y-View imaging for the diagnosis of shoulder impingement syndrome but having trouble for the positioning of patients complaining of shoulder pain. On the result of comparative analysis of the images obtained by changing the lateral-medio degree of X-ray tube into $35^{\circ}$, $40^{\circ}$, and $45^{\circ}$ while patient is in supine position, $40^{\circ}$ of X-ray tube in lateral-medio direction produced the most valuable image for the diagnosis by best describing the shapes of acromion, clavicle space, and coracoacromial arch. Therefore, patients who have difficulty in Y-View position to obtain Y-View image, modified Y-View can be applied as a useful alternative method. By this study, various applications not only in shoulder impingement syndrome but also in diverse omarthralgia diseases are expected.

Comparison of Parallel and Fan-Beam Monochromatic X-Ray CT Using Synchrotron Radiation

  • Toyofuku, Fukai;Tokumori, Kenji;Kanda, Shigenobu;Ohki, Masafumi;Higashida, Yoshiharu;Hyodo, Kazuyuki;Ando, Masami;Uyama, Chikao
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.407-410
    • /
    • 2002
  • Monochromatic x-ray CT has several advantages over conventional CT, which utilizes bremsstrahlung white x-rays from an x-ray tube. There are several methods to produce such monochromatic x-rays. The most popular one is crystal diffraction monochromatization, which has been commonly used because of the fact that the energy spread is very narrow and the energy can be changed continuously. The alternative method is the use of fluorescent x-ray, which has several advantages such as large beam size and fast energy change. We have developed a parallel-beam and a fan-beam monochromatic x-ray CT, and compared some characteristics such as accuracy of CT numbers between those systems. The fan beam monochromatic x-rays were generated by irradiating target materials by incident white x-rays from a bending magnet beam line NE5 in 6.5 GeV Accumulation Ring at Tukuba. The parallel beam monochromatic x-rays were generated by using a silicon double crystal monochromator at the bending magnet beam line BL-20BM in Spring-8. A Cadmium telluride (CdTe) 256 channel array detector with 512mm sensitive width capable of operating at room temperature was used in the photon counting mode. A cylindrical phantom containing eight concentrations of gadolinium was used for the fan beam monochromatic x-ray CT system, while a phantom containing acetone, ethanol, acrylic and water was used for the parallel monochromatic x-ray CT system. The linear attenuation coefficients obtained from CT numbers of those monochromatic x-ray CT images were compared with theoretical values. They showed a good agreement within 3%. It was found that the quantitative measurement can be possible by using the fan beam monochromatic x-ray CT system as well as a parallel beam monochromatic X-ray CT system.

  • PDF

The Bone Mineral Density Value According to the Operating Time of the Dual Energy X-ray (이중 에너지 엑스레이 흡수기의 가동 시간에 따른 골밀도 값의 평가)

  • Lee, Hae-Jung;Kim, Ho-Sung;Kim, Eun-Hye
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.40-45
    • /
    • 2010
  • Purpose: Recently, the performance of the X-ray tube was very much improved by the power generation of the technology. However, the overload of equipment is occurred by the increment of the equipment operating time according to the increment of the examination number of cases. The X-ray dose can change by heat occurrence of the X-ray tube due to this. Moreover, the change of the bone mineral density value is possible to occur. Therefore, We tries to whether the change of the bone mineral density value of each equipment according to the difference of the examination number of cases and operating time occur or not. Materials and Methods: The BMD value was measured by the Aluminum Spine Phantom and the European Spine Phantom in each equipment, in order to find out about the difference of the time general classification bone mineral density value by using the Dual energy X-ray absorptiometry. And after scanning each phantom by using X-ray dose meter (Unfors Mult-O-Meter), a dose was measured by the same condition. As to, an average and standard deviation were found and the change of each equipment much BMD value was compared and it evaluated. Results: $Mean{\pm}SD$ of each equipment by using the Aluminum Spine Phantom, A equipment was $1.174{\pm}0.002$, $1.171{\pm}0.005$, $1.173{\pm}0.005$, B equipment was $1.186{\pm}0.003$, $1.187{\pm}0.003$, $1.185{\pm}0.003$, C equipment was $1.180{\pm}0.003$, $1.182{\pm}0.004$, $1.183{\pm}0.002$, D equipment was $1.188{\pm}0.004$, $1.185{\pm}0.003$, $1.185{\pm}0.004$. By using the European Spine Phantom, A equipment was $1.143{\pm}0.006$, $1.153{\pm}0.009$, $1.161{\pm}0.003$, B equipment was $1.134{\pm}0.004$, $1.13{\pm}0.008$, $1.127{\pm}0.015$, C equipment was $1.143{\pm}0.006$, $1.134{\pm}0.01$, $1.133{\pm}0.006$, D equipment was $1.14{\pm}0.001$, $1.122{\pm}0.002$, $1.131{\pm}0.008$, altogether included in the normal range. Conclusion: There was no significant change of the BMD value of using a phantom by time zones. Therefore, if the quality control is made to use the extent management method of the equipment for beginning in the present application, the reliability of the BMD equipment will be able to be enhanced.

  • PDF

A Composite DorsoPlantar Axial X-ray Projection Study on the Bones of the Whole Infant's Foot (유아 발 전체의 뼈에 대한 합성 전후축방향 엑스선촬영법 연구)

  • Park, Yun;Ahn, Byung-Ju
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.7
    • /
    • pp.1007-1013
    • /
    • 2021
  • A Study that Cronbach Alpha values were Significantly higher at 0.813 in the Composite AP axial Radiography Signal to Noise Ratio(SNR) for Evaluating uniform Density and Advanced Images of the Entire Foot without overlap with the legs. The Subjective Evaluation ROC also scored a high score of 18 on Foot Calcaneus bone 10° from the Foot Metatarsal bone, and 18 on the Examination by tilting the Sharpness X-ray Tube 20° from the Foot Calcaneus bone. Results show uniform Density and images at 10° rearward of Foot Metatarsal bone and 20° forward of Foot Calcaneus bone during the Composite AP axial Radiography X-ray Examination of Infants.

A Study of Radiographic Methods to X-ray Study of Patients with Spinal Scoliosis and Vertebrae Bone Fracture of Lumbar Spine (척주측만증과 허리뼈 골절 수술 환자의 엑스선 촬영법 연구)

  • Ahn, Byung-Ju;Lee, Jun-Haeng
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.3
    • /
    • pp.425-431
    • /
    • 2019
  • The Study In order to obtain images of overlap of the two iron cores in the spinal cord simple x-ray scan after surgery of patients with ulcer lateral sclerosis and a fractured backbone, the researcher conducted a subjective evaluation on five radiographers of the university hospital's imaging department for more than 10 years. The results of the experiment showed that the lateral shot of lateral scoliosis of the spinal cord was taken with the middle face of the IR plane, and then the X-ray tube angle was taken vertically with the vertical spinal column fan-tom position, resulting in two overlapping images and high scores in the subjective evaluation. In addition, lateral shots of the lumbar dislocation fractured lumbar vertebrae were taken with the forehead aligned with the center of the IR plane and then with the X-ray angle perpendicular to the fourth waistline and the angle of the spinal cord perpendicular to the fourth waistline, the image of the two iron cores could be obtained from the radiographer.

Numerical Modeling and Experiment for Single Grid-Based Phase-Contrast X-Ray Imaging

  • Lim, Hyunwoo;Lee, Hunwoo;Cho, Hyosung;Seo, Changwoo;Lee, Sooyeul;Chae, Byunggyu
    • Progress in Medical Physics
    • /
    • v.28 no.3
    • /
    • pp.83-91
    • /
    • 2017
  • In this work, we investigated the recently proposed phase-contrast x-ray imaging (PCXI) technique, the so-called single grid-based PCXI, which has great simplicity and minimal requirements on the setup alignment. It allows for imaging of smaller features and variations in the examined sample than conventional attenuation-based x-ray imaging with lower x-ray dose. We performed a systematic simulation using a simulation platform developed by us to investigate the image characteristics. We also performed a preliminary PCXI experiment using an established a table-top setup to demonstrate the performance of the simulation platform. The system consists of an x-ray tube ($50kV_p$, 5 mAs), a focused-linear grid (200-lines/inch), and a flat-panel detector ($48-{\mu}m$ pixel size). According to our results, the simulated contrast of phase images was much enhanced, compared to that of the absorption images. The scattering length scale estimated for a given simulation condition was about 117 nm. It was very similar, at least qualitatively, to the experimental contrast, which demonstrates the performance of the simulation platform. We also found that the level of the phase gradient of oriented structures strongly depended on the orientation of the structure relative to that of linear grids.

The effects of voltage of x-ray tube on fractal dimension and anisotropy of diagnostic image

  • Baik, Jee-Seon;Lee, Sam-Sun;Park, Kwan-Soo;Huh, Kyung-Hoe;Yi, Won-Jin;Heo, Min-Suk;Choi, Soon-Chul
    • Imaging Science in Dentistry
    • /
    • v.37 no.4
    • /
    • pp.211-215
    • /
    • 2007
  • Purpose: The purpose of this study was to evaluate the effect of the kV on fractal dimension of trabecular bone in digital radiographs. Materials and Methods: 16 bone cores were obtained from patients who had taken partial resection of tibia due to accidents. Each bone core along with an aluminum step wedge was radiographed with an occlusal film at 0.08 sec and with the constant film-focus distance (32 cm). All radiographs were acquired at 60, 75, and 90 kV. A rectangular ROI was drawn at medial part, distal part, and the bone defect area of each bone core image according to each kV. The directional fractal dimension was measured using Fourier Transform spectrum, and the anisotropy was obtained using directional fractal dimension. The values were compared by the repeated measures ANOVA. Results : The fractal dimensions increased along with kV increase (p < 0.05). The anisotropy measurements did not show statistically significant difference according to kV change. The fractal dimensions of the bone defect areas of the bone cores have low values contrast to the non-defect areas of the bone cores. The anisotropy measurements of the bone defect areas were lower than those of the non-defect areas of the bone cores, but not statistically significant. Conclusion: Fractal analysis can notice a difference of a change of voltage of x-ray tube and bone defect or not. And anisotropy of a trabecular bone is coherent even with change of the voltage of x-ray tube or defecting off a part of bone.

  • PDF

Calibration Examination of Dose Area Product Meters using X-ray (X선을 이용한 면적선량계의 교정 연구)

  • Jung, Jae Eun;Won, Do-Yeon;Jung, Hong-Moon;Kweon, Dae Cheol
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.1
    • /
    • pp.37-42
    • /
    • 2017
  • We measured the absorbed dose and the area dose using an ionization chamber type of area dose product (DAP) meter and measured the calibration factor in the X-ray examination. In the indirect dose measurement method, the detector was installed in the radiation part of the X-ray equipment, and the measured value was calculated as the dose at the exposure part. The instrument used to calculate the calibration factor was an X-ray equipment (DK-550R / F, DongKang Medical Co., Ltd., Seoul, Korea). The calibration method for the calibration factor was to connect the DAP meter (PD-8100, Toreck Co. Ltd., Japan) to the calibration dosimeter tube voltage of 70 kV, tube current of 500 mA, 0.158 sec. The reference dosimeter used a semiconductor (DOSIMAX plus A, Scanditronix, $Wellh{\ddot{o}}fer$, Germany). After installing the DAP meter on the front of the multi-collimator of the ionization chamber, the calibration factor of the dosimeter was obtained using the reference dosimeter for accurate dose measurement. Experimental exposure values and values from the calibration dosimeter were calculated by multiplying each calibration factor. The calibration factor was calculated as 1.045. In order to calculate the calibration coefficient according to the tube voltage in the ionization type DAP dosimeter, the absorbed dose and the area dose were calculated and the calibration factor was calculated. The corrective area dose was calculated by calculating the calibration factor of the DAP meter.