• Title/Summary/Keyword: X선 발생장치

Search Result 88, Processing Time 0.023 seconds

Construction of Vacuum system for PAL-XFEL

  • Na, Dong-Hyeon;Ha, Tae-Gyun;Park, Jong-Do
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2015.08a
    • /
    • pp.94.1-94.1
    • /
    • 2015
  • 4세대 방사광 가속기는 선형가속기와 언듈레이터를 활용하여 파장이 0.1 nm인 X선을 빔라인 사용자들에게 제공하는 것을 목표로 하여 2011년부터 건설되고 있다. 이 장치에서 진공시스템은 전자빔 발생장치인 RF Gun을 포함하는 입사장치(Injector)와 빔을 가속시키는 선형가속기(Linac) 그리고 결맞음 방사광을 발생시키는 언듈레이터로 나누어진다. 본 논문에서는 최종 수정 설계 후 제작 및 설치 중인 진공시스템의 건설 현황에 대하여 집중적으로 보고하고자 한다.

  • PDF

The Study on Clinical Conditions and Skin Dose of Upper-Gastrointestinal X-ray Fluoroscopy (위장 X선 투시검사에 따른 실태 및 선량에 관한 연구)

  • Kim, Sung-Chul;Ahn, Sung-Min;Jang, Sang-Sup
    • Journal of radiological science and technology
    • /
    • v.30 no.1
    • /
    • pp.7-12
    • /
    • 2007
  • This study examined present conditions of upper-gastrointestinal X-ray fluoroscopy and patient skin dose. The authors elected 21 equipments to check the X-ray equipment and exposure factor of fluoroscopy & spot exposure in university hospitals, hospitals, and clinics where perform upper-gastrointestinal X-ray fluoroscopy more than five times every day in Incheon areas. The amount of patient's skin dose during upper-gastrointestinal X-ray fluoroscopy was measured by ionization chamber.

  • PDF

The fabrication and evaluation of CdS sensor for diagnostic x-ray detector application (진단 X선 검출기 적용을 위한 CdS 센서 제작 및 성능 평가)

  • Park, Ji-Koon;Lee, Mi-Hyun;Choi, Young-Zoon;Jung, Bong-Zae;Choi, Il-Hong;Kang, Sang-Sik
    • Journal of the Korean Society of Radiology
    • /
    • v.4 no.2
    • /
    • pp.21-25
    • /
    • 2010
  • Recently, various semiconductor compounds as radiation detection material have been researched for a diagnostic x-ray detector application. In this paper, we have fabricated the CdS detecton sensor that has good photosensitivity and high x-ray absorption efficiency among other semiconductor compounds, and evaluated the application feasibility by investigating the detection properties about energy range of diagnostic x-ray generator. We have fabricated the line voltage selector(LCV) for a signal acquisition and quantities of CdS sensor, and designed the voltage detection circuit and rectifying circuit. Also, we have used a relative relation algorithm according to x-ray exposure condition, and fabricated the interface board with DAC controller. Performance evaluation was investigated by data processing using ANOVA program from voltage profile characteristics according to resistive change obtained by a tube voltage, tube current, and exposure time that is a exposure condition of x-ray generator. From experimental results, an error rates were reduced according to increasing of a tube voltage and tube current, and a good properties of 6%(at 90 kVp) and 0.4%(at 320 mA) ere showed. and coefficient of determination was 0.98 with relative relation of 1:1. The error rate according to x-ray exposure time showed exponential reduction because of delayed response velocity of CdS material, and the error rate has 2.3% at 320 msec. Finally, the error rate according to x-ray dose is below 10%, and a high relative relation was showed with coefficient of determination of 0.9898.

Design and Fabrication of High Potential Cenerator for Cathod-ray Apparatus (음극선 발생기를 위한 고전압 발생 장치의 설계 및 제작)

  • 주동만;민경일;황재효
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.2 no.2
    • /
    • pp.11-18
    • /
    • 2001
  • The design method of high potential generator of diagnostic X-ray apparatus by using inverter is presented. For the high potential generator, a line filter, a rectifier, a Pulse width modulation control, bridge drive, a high potential transformer and a high potential rectifier circuit were adopted. The high potential generator with switching frequency to be 40 KHz is fabricated by using design method presented in this method. The experimental results are as followings; variable volts of 0∼620 V and variable currents 50∼500 mA.

  • PDF

High Voltage Resonant DC-DC Converter Design for X-Ray Imaging (X-Ray 진찰용 고전압 공진형 DC-DC 컨버터 설계)

  • Baek, Jong-Mu;Joo, Hae-Jong;Cho, Moon-Taek;Lee, Chung-Sik
    • Journal of the Korean Society of Radiology
    • /
    • v.4 no.4
    • /
    • pp.11-16
    • /
    • 2010
  • In this paper, including the X-ray high voltage resonant inverter generators and high frequency high voltage transformer operating systems is proposed. X-ray generator removes the noise and was smaller, 50[kHz] to work more with the driving frequencies, and that occurred when the normal power supply available due to noise, survey the conditions and solve the problems of the poor was a problem. In addition, X-ray tube voltage, frequency controllers and tube current controller filament heating voltage transformer for high frequency transformer design and manufacture of doing X-ray devices were to become more efficient operation.

Development of High Voltage Generator for Diagnostic X-ray Equipment (진단용 X선 기기의 고전압 발생장치 개발)

  • Kim, Young-Pyo;Kim, Tae-Gon;Cheon, Min-Woo;Park, Yong-Pil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2010.10a
    • /
    • pp.764-765
    • /
    • 2010
  • The medical treatment X-ray machineries used in diagnosis of the human body is possible to diagnosis inside of the human body with the method of noninvasive so that it has shared a very important role in diagnosis from the medical institution. High voltage occurrence system which is most important in occurrence of X-ray has mainly been used the existing type of high voltage transformer, however it has a low efficiency of X-ray occurrence since it is a big and heavy, and a high ripple ratio of the direct current high voltage come to the X-ray tube. In order to solve this problem, the research has been advanced about the high voltage power supply system, and the inverter type of the high voltage occurrence system which occurs a high voltage by increasing the power frequency from about ten times to about hundred times with the inverter has currently used mainly. Also, the operation of tube voltage and tube current was controlled by using PWM method and the operation results were identified using an oscilloscope.

  • PDF

A Preliminary Study on Measuring Void Fraction in a Fuel Rod Assembly by using an X-ray Imaging System (X선 영상 장치를 이용한 핵연료 집합체 내 기포율 측정을 위한 선행 연구)

  • Lee, Sun-Young;Oh, Oh-Sung;Lee, Se-Ho;Lee, Seung-Wook
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.7
    • /
    • pp.571-578
    • /
    • 2017
  • Bubbles are generated by the boiling of the cooling water when an accident occurs in the reactor and then in order to measure the void fraction, the Optical Fiber Probe(OFP) and optical camera are used in thermal hydraulic safety research. However, such an optical method is not suitable for measuring the void fraction in a $17{\times}17$ array of fuel rods due to the geometrical limitations. This study was conducted as a preliminary study using x-ray system and various phantoms before applying to rod bundles. Through radiographic and tomographic experiments, the tube voltage of the x-ray generator was 130 kVp and the tube current was 1 mA. In addition, it is possible to measure the hole of 1mm in size visually through the bubble resolution phantom, and it is confirmed that the contrast is relatively decreased in the inside of the freon in the case of the contrast evaluation using the road phantom. However, we could obtain good image without distortion when reconstructing the image. Bubble generation phantom experiments were used to confirm the flow direction of the bubbles and to acquire tomography images. The image J tool was used to measure the void fraction of 18 % for a single tomography image. This study has carried out previous researches for the measurement of the bubble rate around the nuclear fuel and could be used as a basic research for continuous research.

A Study on the Effects of Muscle Membrane in Tension Development by Computer Image (컴퓨터 영상으로 장력발생이 근육 미치는 영향에 관한 연구)

  • Shin Seung-Soo;Kim Duck-Sool
    • The Journal of the Korea Contents Association
    • /
    • v.5 no.4
    • /
    • pp.71-77
    • /
    • 2005
  • On contraction of the muscles, marked changes in X-ray reflections are observed, suggesting that conformational changes of contractile molecules and the movement of myosin heads during muscle contraction. It was found that the successive twitches decreased not only the time needed to the peak tension after the onset of stimulation but also the time needed to the maximum change of the X-ray intensity. However, the difference of the time between the peak tension and the maximum intensity change$(T_i-I_i)$ is nearly the same at any twitch.

  • PDF

X선 영상 검출기 적용을 위한 $HgI_2$ 필름의 누설전류 특성 향상에 관한 연구

  • Gwon, Cheol;Choe, Chi-Won;Son, Dae-Ung;Jo, Seong-Ho;Gang, Sang-Sik;Nam, Sang-Hui
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.345-345
    • /
    • 2007
  • 본 연구는 x선 영상검출기 적용을 위한 $HgI_2$ 필름의 누설전류 특성 향상을 위한 연구로서, $HgI_2$기반의 다양한 물질을 이용하여 다층구조 방식으로 제작된 필름의 누설전류 특성평가 및 제작된 다층구조의 상부전극물질의 변화에 따른 누설전류 특성을 평가하였다. $HgI_2$기반 다층구조의 제작 물질은 Parylene, $PbI_2$, a-Se을 사용하여 시편(parylene/ITO, ITO/$HgI_2/PbI_2$/ITO, ITO/$HgI_2$/a-Se/ITO)을 제작하였으며, 필름 제작공정은 Screen print, PVD공정으로 다층구조 필름을 제작하였다. 또 한, 다층구조로 제작된 필름에 상부 전극물질은 Au, In, ITO를 사용하여 누설전류의 특성을 평가하였다. 측정 장치로 DC Power Supply(556H. EG&G : 50~200V), X 선 발생장치(Toshiba KXO-50N), 차폐체 (Al 및 Cu), Oscilloscope (LeCroy, LC334AM, USA), Electrometer (Keithley, 6517), Ion chamber 2060 (Radical Co.)을 이용하여, 제작된 $HgI_2$기반 다층구조 sample의 누설전류 특성을 실험하였다. 이 결과로 다층구조에 제작된 물질 및 상부전극에 따른 누설전류의 특성을 평가하였다.

  • PDF