Clinical Usefulness of Implanted Fiducial Markers for Hypofractionated Radiotherapy of Prostate Cancer (전립선암의 소분할 방사선치료 시에 위치표지자 삽입의 유용성)

  • Choi, Young-Min;Ahn, Sung-Hwan;Lee, Hyung-Sik;Hur, Won-Joo;Yoon, Jin-Han;Kim, Tae-Hyo;Kim, Soo-Dong;Yun, Seong-Guk
    • Radiation Oncology Journal
    • /
    • v.29 no.2
    • /
    • pp.91-98
    • /
    • 2011
  • Purpose: To assess the usefulness of implanted fiducial markers in the setup of hypofractionated radiotherapy for prostate cancer patients by comparing a fiducial marker matched setup with a pelvic bone match. Materials and Methods: Four prostate cancer patients treated with definitive hypofractionated radiotherapy between September 2009 and August 2010 were enrolled in this study. Three gold fiducial markers were implanted into the prostate and through the rectum under ultrasound guidance around a week before radiotherapy. Glycerin enemas were given prior to each radiotherapy planning CT and every radiotherapy session. Hypofractionated radiotherapy was planned for a total dose of 59.5 Gy in daily 3.5 Gy with using the Novalis system. Orthogonal kV X-rays were taken before radiotherapy. Treatment positions were adjusted according to the results from the fusion of the fiducial markers on digitally reconstructed radiographs of a radiotherapy plan with those on orthogonal kV X-rays. When the difference in the coordinates from the fiducial marker fusion was less than 1 mm, the patient position was approved for radiotherapy. A virtual bone matching was carried out at the fiducial marker matched position, and then a setup difference between the fiducial marker matching and bone matching was evaluated. Results: Three patients received a planned 17-fractionated radiotherapy and the rest underwent 16 fractionations. The setup error of the fiducial marker matching was $0.94{\pm}0.62$ mm (range, 0.09 to 3.01 mm; median, 0.81 mm), and the means of the lateral, craniocaudal, and anteroposterior errors were $0.39{\pm}0.34$ mm, $0.46{\pm}0.34$ mm, and $0.57{\pm}0.59$ mm, respectively. The setup error of the pelvic bony matching was $3.15{\pm}2.03$ mm (range, 0.25 to 8.23 mm; median, 2.95 mm), and the error of craniocaudal direction ($2.29{\pm}1.95$ mm) was significantly larger than those of anteroposterior ($1.73{\pm}1.31$ mm) and lateral directions ($0.45{\pm}0.37$ mm), respectively (p<0.05). Incidences of over 3 mm and 5 mm in setup difference among the fractionations were 1.5% and 0% in the fiducial marker matching, respectively, and 49.3% and 17.9% in the pelvic bone matching, respectively. Conclusion: The more precise setup of hypofractionated radiotherapy for prostate cancer patients is feasible with the implanted fiducial marker matching compared with the pelvic bony matching. Therefore, a less marginal expansion of planning target volume produces less radiation exposure to adjacent normal tissues, which could ultimately make hypofractionated radiotherapy safer.

Validity of Clinically Used Tray Transmission Factor (임상적으로 쓰이는 차폐선반투과율의 타당성에 관한 연구)

  • 윤형근
    • Progress in Medical Physics
    • /
    • v.14 no.4
    • /
    • pp.218-224
    • /
    • 2003
  • Purpose:By evaluating the dependence of the tray transmission factor (tray factor) on collimator setting and tray thickness, we determined the validity of the clinically used single tray factor for standard radiation field size (10${\times}$10 $\textrm{cm}^2$). Methods and Materials:For each X ray energies (6 and 10 MV), outputs were measured by using 5 steps of tray thickness (0, 6, 8, 10, 12 mm) and 7 steps of radiation field size (5${\times}$5, 10${\times}$10, 15${\times}$15, 20${\times}$20, 25${\times}$25, 30${\times}$30, 35${\times}$35 $\textrm{cm}^2$) at 10 cm phantom depth. Outputs were measured in both 'with tray' and 'without tray' conditions by using radiation with the same monitor units, and the tray factors were determined by the ratios of the two outputs. To evaluate the validity of a single tray factor obtained for standard radiation field, we analyzed the pattern of the field sizes in cases treated at our hospital in 2002. Results : In the 6 MV X-ray, the increases in the tray factor between the standard field (l0${\times}$10 $\textrm{cm}^2$) and the largest field (35${\times}$35 $\textrm{cm}^2$) were 0.517%, 0.835%, 1.058%, 1.066% in 6, 8, 10, and 12 mm thickness tray, respectively. In the 10 MV X-ray, the increases in the fray factor between the standard field (10${\times}$10 $\textrm{cm}^2$) and the largest field (35${\times}$35 $\textrm{cm}^2$) were 0.517%, 0.836%, 1.058%, 1.066% in 6, 8, 10, 12 mm thickness tray, respectively. In a major portion of clinical cases, when the field size was smaller than 20${\times}$20 $\textrm{cm}^2$, the tray factor was in good agreement with the standard tray factor. However, in cases where the field sizes were 30${\times}$30 $\textrm{cm}^2$ and 35${\times}$35 $\textrm{cm}^2$, the error could exceed 1.0%. Conclusion:The tray factor increased with increasing field size or decreasing tray thickness. The difference of tray factor between the small field and the large field increased with increasing tray thickness. Furthermore, the standard tray factor was valid in most clinical cases except for when the field size was greater than 30${\times}$30 $\textrm{cm}^2$, wherein the error could exceed 1.0%.

  • PDF

A Theoretical Study for Estimation of Oxygen Effect in Radiation Therapy (방사선 조사시 산소가 세포에 미치는 영향의 이론적 분석)

  • Rena J. Lee;HyunSuk Suh
    • Progress in Medical Physics
    • /
    • v.11 no.2
    • /
    • pp.157-165
    • /
    • 2000
  • Purpose: For estimation of yields of l)NA damages induced by radiation and enhanced by oxygen, a mathematical model was used and tested. Materials and Methods: Reactions of the products of water radiolysis were modeled as an ordinary time dependant equations. These reactions include formation of radicals, DNA damage, damage repair, restitution, and damage fixation by oxygen and H-radical. Several rate constants were obtained from literature while others were calculated by fitting an experimental data. Sensitivity studies were performed changing the chemical rate constant at a constant oxygen number density and varying the oxygen concentration. The effects of oxygen concentration as well as the damage fixation mechanism by oxygen were investigated. Oxygen enhancement ratio(OER) was calculated to compare the simulated data with experimental data. Results: Sensitivity studies with oxygen showed that DNA survival was a function of both oxygen concentration and the magnitude of chemical rate constants. There were no change in survival fraction as a function of dose while the oxygen concentration change from 0 to 1.0 x 10$^{7}$ . When the oxygen concentration change from 1.0 $\times$ 107 to 1.0 $\times$ 101o, there was significant decrease in cell survival. The OER values obtained from the simulation study were 2.32 at 10% cell survival level and 1.9 at 45% cell survival level. Conclusion: Sensitivity studies with oxygen demonstrated that the experimental data were reproduced with the effects being enhanced for the cases where the oxygen rate constants are largest and the oxygen concentration is increased. OER values obtained from the simulation study showed good agreement for a low level of cell survival. This indicated that the use of the semi-empirical model could predict the effect of oxygen in cell killing.

  • PDF

On-line Image Guided Radiation Therapy using Cone-Beam CT (CBCT) (콘빔CT (CBCT)를 이용한 온라인 영상유도방사선치료 (On-line Image Guided Radiation Therapy))

  • Bak, Jin-O;Jeong, Kyoung-Keun;Keum, Ki-Chang;Park, Suk-Won
    • Radiation Oncology Journal
    • /
    • v.24 no.4
    • /
    • pp.294-299
    • /
    • 2006
  • $\underline{Purpose}$: Using cone beam CT, we can compare the position of the patients at the simulation and the treatment. In on-line image guided radiation therapy, one can utilize this compared data and correct the patient position before treatments. Using cone beam CT, we investigated the errors induced by setting up the patients when use only the markings on the patients' skin. $\underline{Materials\;and\;Methods}$: We obtained the data of three patients that received radiation therapy at the Department of Radiation Oncology in Chung-Ang University during August 2006 and October 2006. Just as normal radiation therapy, patients were aligned on the treatment couch after the simulation and treatment planning. Patients were aligned with lasers according to the marking on the skin that were marked at the simulation time and then cone beam CTs were obtained. Cone beam CTs were fused and compared with simulation CTs and the displacement vectors were calculated. Treatment couches were adjusted according to the displacement vector before treatments. After the treatment, positions were verified with kV X-ray (OBI system). $\underline{Results}$: In the case of head and neck patients, the average sizes of the setup error vectors, given by the cone beam CT, were 0.19 cm for the patient A and 0.18 cm for the patient B. The standard deviations were 0.15 cm and 0.21 cm, each. On the other hand, in the case of the pelvis patient, the average and the standard deviation were 0.37 cm and 0.1 cm. $\underline{Conclusion}$: Through the on-line IGRT using cone beam CT, we could correct the setup errors that could occur in the conventional radiotherapy. The importance of the on-line IGRT should be emphasized in the case of 3D conformal therapy and intensity-modulated radiotherapy, which have complex target shapes and steep dose gradients.

Development of Respiration Gating RT Technique using Moving Phantom and Ultrasound Sensor: a feasibility study (동 팬텀과 초음파 센서를 이용한 호흡운동 조절 방사선치료 기술 개발)

  • Lee, Suk;Lee, Sang-Hoon;Shin, Dong-Ho;Yang, Dae-Sik;Choi, Myung-Sun;Kim, Chul-Yong
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2004.11a
    • /
    • pp.122-125
    • /
    • 2004
  • In radiotherapy of tumors in liver, enough planning target volume (PTV) margins are necessary to compensate breathing-related movement of tumor volumes. To overcome the problems, this study aims to obtain patients' body movements by using a moving phantom and an ultrasonic sensor, and to develop respiration gating techniques that can adjust patients' beds by using reversed values of the data obtained. The phantom made to measure patients' body movements is composed of a microprocessor (BS II, 20 MHz, 8K Byte), a sensor (Ultra-Sonic, range 3 cm ${\sim}$3 m), host computer (RS232C) and stepping motor (torque 2.3Kg) etc., and the program to control and operate it was developed. The program allows the phantom to move within the maximum range of 2 cm, its movements and corrections to take place in order, and x, y and z to move successively. After the moving phantom was adjusted by entering random movement data(three dimensional data form with distance of 2cm), and the phantom movements were acquired using the ultra sonic sensor, the two data were compared and analyzed. And then, after the movements by respiration were acquired by using guinea pigs, the real-time respiration gating techniques were drawn by operating the phantom with the reversed values of the data. The result of analyzing the acquisition-correction delay time for the three types of data values and about each value separately shows that the data values coincided with one another within 1% and that the acquisition-correction delay time was obtained real-time (2.34 ${\times}$ 10$^{-4}$sec). This study successfully confirms the clinic application possibility of respiration gating techniques by using a moving phantom and an ultra sonic sensor. With ongoing development of additional analysis system, which can be used in real-time set-up reproducibility analysis, it may be beneficially used in radiotherapy of moving tumors.

  • PDF

Comparison of Electrical Signal Properties about Top Electrode Size on Photoconductor Film (광도전체 필름 상부 전극크기에 따른 전기적 신호 특성 비교)

  • Kang, Sang-Sik;Jung, Bong-Jae;Noh, Si-Cheul;Cho, Chang-Hoon;Yoon, Ju-Sun;Jeon, Sung-Pyo;Park, Ji-Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.2
    • /
    • pp.93-96
    • /
    • 2011
  • Currently, the development of direct conversion radiation detector using photoconductor materials is progressing in widely. Among of theses photoconductor materials, mercuric iodide compound than amorphous selenium has excellent absorption and sensitivity of high energy radiation. Also, the detection efficiency of signal generated in photoconductor film varies by electric filed and geometric distribution according to top-bottom electrode size. Therefore, in this work, the x-ray detection characteristics are investigated about the size of top electrode in $HgI_2$ photoconductor film. For sample fabrication, to solve the problem that is difficult to make a large area film, we used the spatial paste screen-print method. And the sample thickness is $150{\mu}m$ and an film area size is $3cm{\times}3cm$ on ITO-coated glass substrate. ITO(Indium-Tin-Oxide) electrode was used as top electrode using a magnetron sputtering system and each area is $3cm{\times}3cm$, $2cm{\times}2cm$ and $1cm{\times}1cm$. From experimental measurement, the dark current, sensitivity and SNR of the $HgI_2$ film are obtained from I-V test. From the experimental results, it shows that the sensitivity increases in accordance with the area of the electrode but the SNR is decreased because of the high dark current. Therefore, the optimized size of electrode is importance for the development of photoconductor based x-ray imaging detector.

Radiotherapy Results of Midline Malignant Reticulosis (MMR) (중심선 악성 세망증의 방사선 치료 결과)

  • Yun, Sang-Mo;Kim, Jae-Cheol
    • Radiation Oncology Journal
    • /
    • v.14 no.4
    • /
    • pp.291-297
    • /
    • 1996
  • Purpose : This study was performed to evaluate survival, failure patterns, and prognostic factors of MMR patients after radiation therapy. We also discussed the need for chemotherapy. Materials and Methods : A retrospective analysis was done for 23 patients with MMR who were treated with radiation therapy from June 1985 to November 1992. There were 19 male and 4 female patients, The patients' age ranged from 17 to 71 years (median 39 years). Systemic symptoms including fever, weight loss, or malaise were found in $30\%$ of the patients. The nasal cavity was most frequently involved No patients had nodal involvement at diagnosis. There were 2 patients with distant metastasis at presentation. Radiation therapy was delivered five times a week, 1.8 Gy daily, total $45\~54$ Gy (median 50.4 Gy) using 6 MV X-ray No patients received chemotherapy as initial treatment. Results : Overall 5-year and 10-year survival rates were $52.4\%$ and $44.1\%$, respectively. Seventy Percent(12/17) of the patients achieved complete response to radiotherapy, and $29.4\%$ (5/17) achieved partial response. The Patients with complete response showed a better 5-year survival rate than those with partial response ($66.9\%$ vs. $20\%$. p=0.004). Symptom duration before diagnosis, the presence of systemic symptom, and the number of primary sites had no influence on survival. The patterns of failure were as follows: local failure(1), failure in adjacent site(1), local and distant failure(1) distant metastasis(2). and conversion to malignant lymphoma(1). We could not find factors associated with the patterns of failure. Conclusion : The most important facto associated with survival was the response to radiotherapy. Seventeen percent of the patients had distant metastasis, and the salvage after distant metastasis was not successful. However. about $50\%$ of the patients could achieve long-term survival with local radiation therapy alone. Therefore, chemotherapy of MMR should be done after a prospective randomized study for the factors associated with distant metastasis.

  • PDF

Evaluation of Radiation Shielding Rate of Lead Aprons in Nuclear Medicine (핵의학과에서 사용하는 납 앞치마의 방사선 차폐율 평가)

  • Han, Sang-Hyun;Han, Beom-Heui;Lee, Sang-Ho;Hong, Dong-Heui;Kim, Gi-Jin
    • Journal of radiological science and technology
    • /
    • v.40 no.1
    • /
    • pp.41-47
    • /
    • 2017
  • Considering that the X-ray apron used in the department of radiology is also used in the department of nuclear medicine, the study aimed to analyze the shielding rate of the apron according to types of radioisotopes, thus ${\gamma}$ ray energy, to investigate the protective effects. The radioisotopes used in the experiment were the top 5 nuclides in usage statistics $^{99m}Tc$, $^{18}F$, $^{131}I$, $^{123}I$, and $^{201}Tl$, and the aprons were lead equivalent 0.35 mmPb aprons currently under use in the department of nuclear medicine. As a result of experiments, average shielding rates of aprons were $^{99m}Tc$ 31.59%, $^{201}Tl$ 68.42%, and $^{123}I$ 76.63%. When using an apron, the shielding rate of $^{131}I$ actually resulted in average dose rate increase of 33.72%, and $^{18}F$ showed an average shielding rate of -0.315%, showing there was almost no shielding effect. As a result, the radioisotopes with higher shielding rate of apron was in the descending order of $^{123}I$, $^{201}Tl$, $^{99m}Tc$, $^{18}F$, $^{131}I$. Currently, aprons used in the nuclear medicine laboratory are general X-ray aprons, and it is thought that it is not appropriate for nuclear medicine environment that utilizes ${\gamma}$ rays. Therefore, development of nuclear medicine exclusive aprons suitable for the characteristics of radioisotopes is required in consideration of effective radiation protection and work efficiency of radiation workers.

Results of Concurrent Chemoradiotherapy and Intraluminal Brachytherapy in Esophageal Carcinoma - Retrospective Analysis with Respect to Survival - (식도암에서 동시 항암화학방사선요법과 관내근접치료의 결과 -생존율을 중심으로 한 후향적 분석-)

  • Nam Taek-Keun;Nah Byung-Sik;Chung Woong-Ki;Ahn Sung-Ja;Song Ju-Young
    • Radiation Oncology Journal
    • /
    • v.22 no.1
    • /
    • pp.25-32
    • /
    • 2004
  • Purpose : Evaluate the efficacies and toxicities of concurrent chemoradiotherapy (CCRT), with or without intraluminal brachytherapy (ILB), using a retrospective analysis in esophageal carcinomas with respect to survival. Materials and Methods : From April 1995 to July 2001, a total of 65 patients, diagnosed with an esophageal carcinoma, were treated by CCRT, with 21 also treated by ILB after CCRT. External radiotherapy was peformed using 6 or 10 MV X-rays, with a dose range of $46.8~\69.6$ Gy (median; 59.4). The ILB was peformed using high-dose-rate brachytherapy with Ir-192. The fractionation of ILB was 3 Gy by 4, or 5 Gy by 2 fractions. Cisplatin $(75\;mg/m^2)$ was given on each first day of weeks 1, 5, 9 and 13, and 5-FU $(1,000\;mg/m^2)$ as a continuous infusion for the first 4 days of each course. Results : The median survival time of all patients was 15 months, and the 1, 2 and 3-year survival rates were 55.4, 29.2 and $20.7\%$, respectively. The 2-year survival rates of the patients with and without ILB were 33.3 and $27.3\%$, respectively (p=0.80). The 2-year survival rates of the patients with a complete, partial and no response were 44.1, 13.8 and $0\%$, respectively (p=0.02). The response to treatment was the only significant factor affecting the overall survival from a multivariate analysis. Conclusion : This study has shown that the survival outcomes of CCRT were much better than previous results with radiotherapy alone. However, the addition of ILB after CCRT showed no advantage over that of CCRT alone.

Computer Assisted EPID Analysis of Breast Intrafractional and Interfractional Positioning Error (유방암 방사선치료에 있어 치료도중 및 분할치료 간 위치오차에 대한 전자포탈영상의 컴퓨터를 이용한 자동 분석)

  • Sohn Jason W.;Mansur David B.;Monroe James I.;Drzymala Robert E.;Jin Ho-Sang;Suh Tae-Suk;Dempsey James F.;Klein Eric E.
    • Progress in Medical Physics
    • /
    • v.17 no.1
    • /
    • pp.24-31
    • /
    • 2006
  • Automated analysis software was developed to measure the magnitude of the intrafractional and interfractional errors during breast radiation treatments. Error analysis results are important for determining suitable planning target volumes (PTV) prior to Implementing breast-conserving 3-D conformal radiation treatment (CRT). The electrical portal imaging device (EPID) used for this study was a Portal Vision LC250 liquid-filled ionization detector (fast frame-averaging mode, 1.4 frames per second, 256X256 pixels). Twelve patients were imaged for a minimum of 7 treatment days. During each treatment day, an average of 8 to 9 images per field were acquired (dose rate of 400 MU/minute). We developed automated image analysis software to quantitatively analyze 2,931 images (encompassing 720 measurements). Standard deviations ($\sigma$) of intrafractional (breathing motion) and intefractional (setup uncertainty) errors were calculated. The PTV margin to include the clinical target volume (CTV) with 95% confidence level was calculated as $2\;(1.96\;{\sigma})$. To compensate for intra-fractional error (mainly due to breathing motion) the required PTV margin ranged from 2 mm to 4 mm. However, PTV margins compensating for intefractional error ranged from 7 mm to 31 mm. The total average error observed for 12 patients was 17 mm. The intefractional setup error ranged from 2 to 15 times larger than intrafractional errors associated with breathing motion. Prior to 3-D conformal radiation treatment or IMRT breast treatment, the magnitude of setup errors must be measured and properly incorporated into the PTV. To reduce large PTVs for breast IMRT or 3-D CRT, an image-guided system would be extremely valuable, if not required. EPID systems should incorporate automated analysis software as described in this report to process and take advantage of the large numbers of EPID images available for error analysis which will help Individual clinics arrive at an appropriate PTV for their practice. Such systems can also provide valuable patient monitoring information with minimal effort.