• Title/Summary/Keyword: Wrist Motion

Search Result 203, Processing Time 0.023 seconds

Development of Sleeve Patterns of Structural Firefighting Protective Clothing using by 3D Body Shape and 3D Motion Analysis (3차원 인체형상과 3차원 동작분석에 의한 방화복 소매패턴 개발)

  • Han, Sul-Ah;Nam, Yun-Ja;Yoon, Hye-Jun;Lee, Sang-Hee;Kim, Hyun-Joo
    • Fashion & Textile Research Journal
    • /
    • v.14 no.1
    • /
    • pp.109-121
    • /
    • 2012
  • This study aims at developing ergonomics patterns for the sleeve of structural firefighting protective clothing through 3D motion analysis in order to ensure efficiency and safety of firefighters who are exposed to harmful environment at work. A new research pattern was developed by applying the total results of 3D motion analysis, changes of body surface length measurements, and 2D data on 3D body shape analysis on the size 3 patterns of the existing coat sleeve. For the sleeves, we used the body surface length of the range of shoulder's flexion and the joint angle of the range of wrist's ulnar deviation. And for the production of structural firefighting protective clothing using the research pattern, we recruited a recognized producer of structural firefighting protective clothing designated by KFI. Unlike everyday clothes, structural firefighting protective clothing should be able to fully protect the wearers from the harmful environment that threatens their lives and should not cause any restrictions on their movement. Therefore, the focus of research and development of such protective clothing should be placed on consistent development of new technologies and production methods that will provide protection and comfort for the wearer rather than production cost reduction or operational efficiency. This study is meaningful as it applied 3D motion analysis instead of the existing methods to develop the patterns. In particular, since 3D motion analysis enables the measurement of the range of motion, there should be continuous research on the development of ergonomics patterns that consider workers' range of motion.

Biomechanical Analysis of Arm Motion during Steering Using Motion Analysis Technique (동작분석기법을 이용한 조향동작에 대한 팔의 생체역학적 특성분석)

  • Kim, Young-Hwan;Tak, Tea-Oh
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.11
    • /
    • pp.1391-1398
    • /
    • 2011
  • Biomechanical analysis of arm motion during steering was performed using a motion analysis technique. Three-dimensional position data for each part of arm are fed into an interactive model combining a musculoskeletal arm model and the mechanical steering system to calculate joint angles and torques using inverse kinematic and dynamic analyses, respectively. The analysis shows that elbow pronation/supination, wrist flexion/extension, shoulder adduction/abduction, and shoulder flexion/extension have significant magnitudes. Sensitivity analysis of the arm joint motion with respect to seating posture and steering wheel configuration is carried out to investigate the qualitative influence of the seating posture and driver's seat configuration on the steering behavior.

Marionette Control System using Gesture Mode Change (제스처 할당 모드를 이용한 마리오네트 조정 시스템)

  • Cheon, Kyeong-Min;Kwak, Su Hui;Rew, Keun-Ho
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.21 no.2
    • /
    • pp.150-156
    • /
    • 2015
  • In this paper, a marionette control system using wrist and finger gestures through an IMU sensor is studied. The signals from the sensor device are conditioned and recognized, then the commands are sent to the 8 motors of the marionette via Bluetooth (5 motors control the motion of the marionette, and 3 motors control the location of the marionette). It is revealed that the degree of freedom of fingers are not independent from each other, therefore, some gestures are hardly made. Gesture mode changes for difficult postures of the fingers in cases of a lack of finger DOF are proposed. Therefore, the gesture mode change switches the assignment of gesture as required. Experimental results show that gesture mode change is successful for appropriate postures of a marionette.

Correlation analysis of finger movements in dynamic hand grasping (잡기 동작에서 손가락 동작의 상관관계 분석)

  • Ryu, Tae-Beom;Yun, Myeong-Hwan
    • Journal of the Ergonomics Society of Korea
    • /
    • v.20 no.3
    • /
    • pp.11-25
    • /
    • 2001
  • AS human movements have the inherent property of anticipating target and can be coordinated to realize a given schedule, finger movements have stereotyped patterns during hand grasping. Finger movements have been studied in the past to find out the coordination pattern of hand joint angular movement. These studies analyzed only a few finger joints for a limited number of hand postures. This study investigated fourteen joint angles during eight hand-grasping motions to analyze the angular correlations between finger joints and to suggest motion factors which represent hand grasping. Hand grasping motions including forward arm motion were examined in ten healthy volunteers. Eight objects were used to represent real hand grasping tasks. $CyberGlove^{TM}$ and $Fasreack^{TM}$ measured hand joint angles and wrist origin. Joint angle correlations between PIJ(proximal interphalangeal joint) and MPJ(metacarpophalangeal joint) at one finger, between neighboring PIJs and MPJs were four factors related to the fast phase of hand grasping motions and eight factors related to the slow phase of hand grasping motions.

  • PDF

Hand Gesture Segmentation Method using a Wrist-Worn Wearable Device

  • Lee, Dong-Woo;Son, Yong-Ki;Kim, Bae-Sun;Kim, Minkyu;Jeong, Hyun-Tae;Cho, Il-Yeon
    • Journal of the Ergonomics Society of Korea
    • /
    • v.34 no.5
    • /
    • pp.541-548
    • /
    • 2015
  • Objective: We introduce a hand gesture segmentation method using a wrist-worn wearable device which can recognize simple gestures of clenching and unclenching ones' fist. Background: There are many types of smart watches and fitness bands in the markets. And most of them already adopt a gesture interaction to provide ease of use. However, there are many cases in which the malfunction is difficult to distinguish between the user's gesture commands and user's daily life motion. It is needed to develop a simple and clear gesture segmentation method to improve the gesture interaction performance. Method: At first, we defined the gestures of making a fist (start of gesture command) and opening one's fist (end of gesture command) as segmentation gestures to distinguish a gesture. The gestures of clenching and unclenching one's fist are simple and intuitive. And we also designed a single gesture consisting of a set of making a fist, a command gesture, and opening one's fist in order. To detect segmentation gestures at the bottom of the wrist, we used a wrist strap on which an array of infrared sensors (emitters and receivers) were mounted. When a user takes gestures of making a fist and opening one's a fist, this changes the shape of the bottom of the wrist, and simultaneously changes the reflected amount of the infrared light detected by the receiver sensor. Results: An experiment was conducted in order to evaluate gesture segmentation performance. 12 participants took part in the experiment: 10 males, and 2 females with an average age of 38. The recognition rates of the segmentation gestures, clenching and unclenching one's fist, are 99.58% and 100%, respectively. Conclusion: Through the experiment, we have evaluated gesture segmentation performance and its usability. The experimental results show a potential for our suggested segmentation method in the future. Application: The results of this study can be used to develop guidelines to prevent injury in auto workers at mission assembly plants.

Kinematic Variables Comparison of Setter Toss Motion on Volleyball According to Toss Types (배구경기 세터 토스 동작의 운동학적 비교분석)

  • Chung, Nam-Ju;Kim, Jae-Pil
    • Korean Journal of Applied Biomechanics
    • /
    • v.25 no.1
    • /
    • pp.57-64
    • /
    • 2015
  • Purpose : The purpose of this study was to analyze setter toss motion kinematically according to toss types. Method : Dependent variables were elapsed time, vertical displacement of the body center, the projected speed of the ball, and differences of the joint angle to the target for four setters positioning. Result : There was no significant difference in the time but the ball contact time was shorter when the toss distance of P3 was longer. There was significant difference in the vertical displacement of COM (p<.05). The vertical displacement of COM showed that the vertical movement gradually decreased when the quick distance was longer. The vertical displacement of COM was difference (p<.05), also there was difference of the ball speed (p<.001) at the Release point(E4). There was significant difference in the knee joint angle at a certain moment among the Release(E4) and Landing point(E5)(p<.05). The hip joint was significant difference among the Apex(E2), Ball Touch(E3), Release(E4), and the Landing point(E5) on the surface(E2, E3, E4 p<.05; E5 p<.005). The shoulder angle was significant difference among the Ball Touch(E3), Release(E4) and the Landing point(E5) on the surface(E3, E4 p<.05; E5 p<.001). The elbow was significant difference in the Apex(E2) (p<.05). The wrist was significant difference in the Release(E4) (p<.05). Conclusion : If we find the clue to expect the direction of the setter's ball, we have to fine the clues in the Apex(E2) that hip join and elbow, Ball Touch(E3) that hip joint and shoulder joint, Release(E4) that wrist, elbow, hip joint, and knee joint.

Mid to Long-term Outcome of Vascularized Pronator Quadratus-wrapped Radial Bone Flap Arthroplasty for Advanced $Kienb{\ddot{o}}ck's$ Disease (진행된 키엔벡 병에서의 방형회내근 유경 요골 피판을 이용한 관절성형술의 중장기 결과)

  • Gong, Hyun-Sik;Baek, Goo-Hyun;Lee, Young-Ho;Kim, Sae-Hoon;Cho, Young-Jae;Chung, Moon-Sang
    • Archives of Reconstructive Microsurgery
    • /
    • v.15 no.2
    • /
    • pp.101-106
    • /
    • 2006
  • The purpose of this study was to analyze the mid to long-term clinical and radiological outcome of vascularized pronator quadratus-wrapped radial bone flap arthroplasty for symptomatic advanced $Kienb{\ddot{o}}ck's$ disease. Between 1982 and 2000, 41 cases of advanced $Kienb{\ddot{o}}ck's$ disease were treated with vascularized pronator quadratus wrapped radial bone flap arthroplasty. There were 17 men and 24 women, with a mean age of 39 years at the time of operation. According to Lichtman's classification, there were 13 stage IIIb and 28 stage IV patients. The duration of follow-up averaged 6.1 ($3{\sim}22$) years. We assessed the clinical outcome by subjective pain and active range of motion of the wrist, and evaluated the radiologic outcome by using carpal height ratio and radioscaphoid angle. Postoperatively, all patient reported an improvement in their symptoms. The mean active extension and flexion were improved by $9^{\circ}$ and $6^{\circ}$, respectively (p<0.05). The carpal height ratio was decreased from a mean of 0.52 to 0.48, and the radioscahpoid angle was increased from a mean of $61^{\circ}$ to $66^{\circ}$, but the differences were not significant statistically. Vascularized pronator quadratus-wrapped radial bone flap arthroplasty improves the wrist motion and may prevent serious carpal collapse in advanced $Kienb{\ddot{o}}ck's$ Disease.

  • PDF

Analysis on the Kinematics and Dynamics of Human Arm Movement Toward Upper Limb Exoskeleton Robot Control - Part 2: Combination of Kinematic and Dynamic Constraints (상지 외골격 로봇 제어를 위한 인체 팔 동작의 기구학 및 동역학적 분석 - 파트 2: 제한조건의 선형 결합)

  • Kim, Hyunchul;Lee, Choon-Young
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.20 no.8
    • /
    • pp.875-881
    • /
    • 2014
  • The redundancy resolution of the seven DOF (Degree of Freedom) upper limb exoskeleton is key to the synchronous motion between a robot and a human user. According to the seven DOF human arm model, positioning and orientating the wrist can be completed by multiple arm configurations that results in the non-unique solution to the inverse kinematics. This paper presents analysis on the kinematic and dynamic aspect of the human arm movement and its effect on the redundancy resolution of the seven DOF human arm model. The redundancy of the arm is expressed mathematically by defining the swivel angle. The final form of swivel angle can be represented as a linear combination of two different swivel angles achieved by optimizing two cost functions based on kinematic and dynamic criteria. The kinematic criterion is to maximize the projection of the longest principal axis of the manipulability ellipsoid of the human arm on the vector connecting the wrist and the virtual target on the head region. The dynamic criterion is to minimize the mechanical work done in the joint space for each of two consecutive points along the task space trajectory. The contribution of each criterion on the redundancy was verified by the post processing of experimental data collected with a motion capture system. Results indicate that the bimodal redundancy resolution approach improved the accuracy of the predicted swivel angle. Statistical testing of the dynamic constraint contribution shows that under moderate speeds and no load, the dynamic component of the human arm is not dominant, and it is enough to resolve the redundancy without dynamic constraint for the realtime application.

Steindler Flexoplasty of Elbow in Brachial Plexus Injuries (상완 신경총 손상에서 Steindler 주관절 굴곡 성형술)

  • Han, Chung-Soo;Chung, Duke-Whan;Jeong, Bi-O;Lee, Kyung-Won
    • Archives of Reconstructive Microsurgery
    • /
    • v.14 no.1
    • /
    • pp.63-69
    • /
    • 2005
  • Purpose: The purpose of this study was to analyze the clinical results after Steindler flexoplasty. Materials and Methods: We analyzed 6 cases who had nearly normal finger and wrist joint flexion function, but could not flex elbow joint actively because of upper arm type brachial plexus injury. We performed operation during the period from February 1997 to July 2003. There were 5 males and 1 female with mean age of 28 years (range: $19{\sim}51$ years) when Steindler flexoplasty was done. The average follow-up period was 3 years 11 months (range: 12 months${\sim}$7 years 4 months). We assessed active range of motion of elbow joint, muscle power and elbow function by Mayer & Green grade scale at last follow-up. We assessed how much they were favorable for Steindler flexoplasty and had improvement of upper extremity function and correction of deformity. Results: Postoperative, flexion range of elbow joint improved to average $111.7^{\circ}$ (range: $90{\sim}130^{\circ}$). $25.8^{\circ}$ (range: $15{\sim}45^{\circ}$) in flexion contracture and $16.6^{\circ}$ (range: $10{\sim}35^{\circ}$) in pronation contracture were remained. Range of motion of elbow joint improved to average $85.3^{\circ}$ (range: $45{\sim}105^{\circ}$). Flexion power of elbow joint improved to Grade 5 in all cases. Postoperatively on Mayer & Green grade scale, there were excellent in 3 cases(50%), good in 2 cases(33.3%), fair in 1 case(16.7%). On patient's own assessment of functional improvement, there were excellent in 4 cases(66.6%), good in 1 case(16.7%) and fair in 1 case(l6.7%). Conclusion: Steindler flexoplasty can reserve good clinical results with being improved to active flexion of elbow joint in cases who have functional hand and wrist, but paralysis upper arm muscle in brachial plexus injury.

  • PDF

The Effects of Kaltenborn-Evjenth Joint Mobilization of Application Count on Joint Mobility, Pain, Functions and Grip Strength in Patients with Distal Radius Fracture (먼쪽 노뼈 골절환자에게 적용한 칼텐본-에반스 관절가동술의 적용 횟수가 노자관절의 운동성, 통증, 기능과 악력에 미치는 영향)

  • Kim, Myoung-Jin;Seo, Dong-Kwon;Lee, Yeon-Seop
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.10 no.3
    • /
    • pp.247-256
    • /
    • 2022
  • Purpose : The purpose of this study was to investigate the effects of Kaltenborn-Evjenth (KE) joint mobilization of the distal radioulnar joints (RUJ) and proximal RUJ in distal radius fractures (DRFs) on range of motion (ROM), grip strength (GS), and patient-written wrist evaluation (PRWE) in each group once, thrice, or fivefold. Methods : Forty-two subjects participated in this study. We divided the subjects with DRFs into groups applying KE concepts RUJ mobilization once, thrice, and fivefold. The patients' ROM and GS were measured using a joint goniometer and dynamometer, respectively. Pain and function were also assessed using a PRWE. In the statistical analysis, all data were tested for normality using the Shapiro-Wilk test, and paired t-tests were performed for within-group before-and-after comparisons of each intervention. One-way analysis of variance was used for between-group comparisons of differences. All statistical significance levels were set at α=.05. Results : There were significant differences in the ROM in all three groups before and after the intervention (p<.05), but there were no significant differences between the groups. There were significant differences in the GS in the three groups before and after the intervention (p<.05), but there were no significant differences between the groups. In the pain part of the PRWE, all three groups had significant differences before and after intervention (p<.05), but there was no significant difference between the groups. In the functional part of the PRWE, there were significant differences in the three groups before and after intervention (p<.05), but no significant difference occurred between the groups. Conclusion : Based on the aforementioned results, there were no significant between-group differences in ROM, GS, and PRWE (pain and function) after the application of the K-E joint mobilization to DRFs once, thrice, and fivefold. Nevertheless, there were significant within-group differences in all the above.