• Title/Summary/Keyword: Working distance

Search Result 500, Processing Time 0.029 seconds

Evaluation of Radon Exposure During Highway Tunnel Construction by New Austrian Tunneling Method (NATM 공법에 의한 고속도로 터널 공사 중 라돈 노출 평가)

  • Ye-Ji Yu;Hyoung-Ryoul Kim;Mo-Yeol Kang;Sangjun Choi
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.33 no.2
    • /
    • pp.115-125
    • /
    • 2023
  • Objectives: This study was conducted to measure the level of radon in the air at a highway tunnel construction site in a gneiss area using the New Austrian Tunneling Method (NATM) and to evaluate exposure levels by occupation. Methods: Radon concentrations in the air were measured using E-PERM at points 300 m, 600 m, and 900 m from the tunnel entrance during the excavation and waterproofing work inside the tunnel. In addition, radon concentrations were measured during external excavation to compare with the inside of the tunnel. Personal exposure levels for major occupations including tunnel workers, construction equipment operators, waterproofers, shotcrete workers, and safety and health managers who participated in the construction were estimated using radon concentration measured in the work process area and working hours by occupation. Results: As a result of a total of 77 radon measurements, the geometric mean (GM) concentration was 71.1 Bq/m3, and the maximum concentration was 127.3 Bq/m3, which was below the indoor air quality criteria. Radon concentration by process decreased in the order of the tunnel excavation process (GM= Bq/m3, GSD=1.2), waterproofing process (GM=73.35 Bq/m3, GSD=1.2), and outside excavating process (GM=45.28 Bq/m3, GSD=1.2). Processes inside the tunnel were significantly higher than outside excavating processes (p<0.05). There was no statistically significant difference in radon concentration measured inside by distance from the tunnel entrance, but the innermost point of the tunnel, 900 m (GM=79.24 Bq/m3, GSD=1.27), measured the highest. Conclusions: The occupation with the highest individual exposure to radon was tunnel worker (64.16 Bq/m3), followed by construction equipment driver (64.04 Bq/m3) and waterproofer (63.13 Bq/m3).

Development of Pollutant Transport Model Working In GIS-based River Network Incorporating Acoustic Doppler Current Profiler Data (ADCP자료를 활용한 GIS기반의 하천 네트워크에서 오염물질의 이송거동모델 개발)

  • Kim, Dongsu
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.6B
    • /
    • pp.551-560
    • /
    • 2009
  • This paper describes a newly developed pollutant transport model named ARPTM which was designed to simulate the transport and characteristics of pollutant materials after an accidental spill in upstream of river system up to a given position in the downstream. In particular, the ARPTM incorporated ADCP data to compute longitudinal dispersion coefficient and advection velocity which are necessary to apply one-dimensional advection-dispersion equation. ARPTM was built on top of the geographic information system platforms to take advantage of the technology's capabilities to track geo-referenced processes and visualize the simulated results in conjunction with associated geographic layers such as digital maps. The ARPTM computes travel distance, time, and concentration of the pollutant cloud in the given flow path from the river network, after quickly finding path between the spill of the pollutant material and any concerned points in the downstream. ARPTM is closely connected with a recently developed GIS-based Arc River database that stores inputs and outputs of ARPTM. ARPTM thereby assembles measurements, modeling, and cyberinfrastructure components to create a useful cyber-tool for determining and visualizing the dynamics of the clouds of pollutants while dispersing in space and time. ARPTM is expected to be potentially used for building warning system for the transport of pollutant materials in a large basin.

Measurement and analysis of tractor emission during plow tillage operation

  • Jun-Ho Lee;Hyeon-Ho Jeon;Seung-Min Baek;Seung-Yun Baek;Wan-Soo Kim;Yong-Joo Kim;Ryu-Gap Lim
    • Korean Journal of Agricultural Science
    • /
    • v.50 no.3
    • /
    • pp.383-394
    • /
    • 2023
  • In Korea, the U.S. Tier-4 Final emission standards have been applied to agricultural machinery since 2015. This study was conducted to analyze the emission characteristics of agricultural tractors during plow tillage operations using PEMS (portable emissions measurement systems). The tractor working speed was set as M2 (5.95 km/h) and M3 (7.60 km/h), which was the most used gear stage during plow tillage operation. An engine idling test was conducted before the plow tillage operation was conducted because the level of emissions differed depending on the temperature of the engine (cold and hot states). The estimated level of emissions for the regular area (660 m2), which was the typical area of cultivation, was based on an implement width of 2.15 m and distance from the work area of 2.2 m. As a result, average emission of CO (carbon monoxide), THC (total hydrocarbons), NOx (nitric oxides), and PM (particulate matter) were approximately 6.17×10-2, 3.36×10-4, 2.01×10-4, and 6.85×10-6 g/s, respectively. Based on the regular area, the total emission of CO, THC, NOx, and PM was 2.62, 3.76×10-2, 1.63, and 2.59×10-4 g, respectively. The results of total emission during plow tillage were compared to Tier 4 emission regulation limits. Tier 4 emission regulation limits means maximum value of the emission per consumption power (g/kWh), calculated as ratio of the emission and consumption power. Therefore, the total emission was converted to the emission per power using the rated power of the tractor. The emission per power was found to be satisfied below Tier 4 emission regulation limits for each emission gas. It is necessary to measure data by applying various test modes in the future and utilize them to calculate emission because the emission depends on various variables such as measurement environment and test mode.

A Research on Applicability of Drone Photogrammetry for Dam Safety Inspection (드론 Photogrammetry 기반 댐 시설물 안전점검 적용성 연구)

  • DongSoon Park;Jin-Il Yu;Hojun You
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.5
    • /
    • pp.30-39
    • /
    • 2023
  • Large dams, which are critical infrastructures for disaster prevention, are exposed to various risks such as aging, floods, and earthquakes. Better dam safety inspection and diagnosis using digital transformation technologies are needed. Traditional visual inspection methods by human inspectors have several limitations, including many inaccessible areas, danger of working at heights, and know-how based subjective inspections. In this study, drone photogrammetry was performed on two large dams to evaluate the applicability of digital data-based dam safety inspection and propose a data management methodology for continuous use. High-quality 3D digital models with GSD (ground sampling distance) within 2.5 cm/pixel were generated by flat double grid missions and manual photography methods, despite reservoir water surface and electromagnetic interferences, and severe altitude differences ranging from 42 m to 99.9 m of dam heights. Geometry profiles of the as-built conditions were easily extracted from the generated 3D mesh models, orthomosaic images, and digital surface models. The effectiveness of monitoring dam deformation by photogrammetry was confirmed. Cracks and deterioration of dam concrete structures, such as spillways and intake towers, were detected and visualized efficiently using the digital 3D models. This can be used for safe inspection of inaccessible areas and avoiding risky tasks at heights. Furthermore, a methodology for mapping the inspection result onto the 3D digital model and structuring a relational database for managing deterioration information history was proposed. As a result of measuring the labor and time required for safety inspection at the SYG Dam spillway, the drone photogrammetry method was found to have a 48% productivity improvement effect compared to the conventional manpower visual inspection method. The drone photogrammetry-based dam safety inspection is considered very effective in improving work productivity and data reliability.

Fabrication of High Density and High Uniformity Irradiation Light Source for Exposure Curing System Using 365 nm and 385 nm Wavelength SMD LED and High Transmittance Silicone Resin TIR Bar Type Lens (365 nm 및 385 nm SMD LED와 TIR 바형 렌즈를 이용하는 고밀도 고균일성 특성의 경화용 광원모듈 제작 )

  • Pil Hong Jeong;Beom Jin Kim;Yeong Jin Kim;Dong Gyu Jeon;Hyo Min Kim;Jae Hyeon Kim;Hyeong Min Kim;Gyu Seong Lee;Kawan Anil;Eung Ryul Park;Soon Jae Yu;Min Jun Ann;Do Won Hwang
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.37 no.4
    • /
    • pp.394-399
    • /
    • 2024
  • An irradiator is developed using two UVA wavelength ranges of SMD LEDs as a curing light source. This module has dimensions of 545×111×300 mm3 and is equipped with a TIR bar-shaped lens made of PDMS silicone resin. The developed irradiator offers high uniformity, with 89% in the centerline of the horizontal axis direction, for two different wavelength ranges of 365 nm and 385 nm. The radiation intensity from the light source module shows highly directional characteristics, and the irradiator provides a maximum irradiance of 1,634 mW/cm2 at a working distance of 50 mm. During the initial 5 minutes of operation, the irradiance experiences a rapid decrease. However, this issue is addressed by optimizing the LED's current reduction characteristics and managing the Transistor's temperature rise in the constant current circuit. After continuous operation for approximately 60 minutes. The highest temperature, near the central part of the irradiating surface, reaches 69.7℃, while the lowest temperature, near the edges, is 41.1℃.

The Usefulness Evaluation of Radiation Shielding Devices in PET Scan Procedures (PET 검사 프러시저별 방사선 차폐기구의 유용성 평가)

  • Kim, Yeong-Seon;Seo, Myeong-Deok;Lee, Wan-Kyu;Jeong, Yo-Cheon;Kim, Sang-Wook;Seo, Il-Teak;Song, Jae-Beom
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.65-76
    • /
    • 2010
  • Purpose: he use of PET scanners and the number of patient in Korea have been increased for recent several years dramatically. For this reason, technologists have more possibilities to be exposed to the radiation. The hospitals using PET scanners should make an effort to reduce the radiation exposure dose. The purpose of this study was to evaluate the radiation exposure does when using radiation shielding devices. The evaluation was performed through questionnaire survey and experiment. Materials and Methods: First, the technologists who had experience working in PET center in 2008-2009 were surveyed with questionnaire and TLD Figures, personal opinion of utilization of radiation shielding devices are analyzed. Second, we measured the shielding rate of shielding devices which have been using in PET study procedures. We divided the procedures into four steps; distribution, moving, injection of $^{18}F$-FDG and patient setup. Results: First, the results of this survey, using of L-block+Syringe shield, L-block, Syringe shield, No shield during the injection, were each 58.5%, 20%, 9%, 12.3%. The TLD values according to utilization of radiation shield, using both L-block+Syringe Shield and L-block showed the lower TLD values, and Syringe shield only or No shield showed the higher TLD values. Second, the results of experiments according to PET study procedures measured the shielding rates as follows. The shielding rates during the distribution using L-block, L-block+Apron shield were measured 97.4%, 97.7%. The shielding rates during the $^{18}F$-FDG delivery to the injection room using mobile Syringe shield, Syringe holder, Syringe shield carrier were each 81.7%, 98.9%, 99.7%. The shielding rates during the injection using Syringe shield, L-block, L-block+Syringe shield were measured each 51.9%, 98.3%, 98.7%. The shielding rates of Apron were measured in each 30, 60, 90, 120, 150 cm distance. The measurement were each 16.9%, 14.2%, 16.6%, 17.1%, 18.1%, 18.6%. Conclusion: The most effective method for radiation shielding is to using L-block during the $^{18}F$-FDG distribution and Syringe shield carrier during in moving $^{18}F$-FDG. For the $^{18}F$-FDG injection, L-block+Syringe shield have to be used. The shielding effect of Apron has shown average 16.4%. According to the survey of questionnaire, the operators recognized well risk of the radiation exposure but, tended ignore in working. The radiation dose according to recognition of radiation exposure risk was not relevant. but radiation dose according to utilization of radiation shield lower the more use it. The main reason of no use of shielding devices is cumbersome, 55% of the respondents answered. I'm sure, by use of radiation shield in all PET procedure, radiation exposure will be reduced considerably.

  • PDF

Evaluation on the Radiation Exposure of Radiation Workers in Proton Therapy (양성자 치료 시 방사선 작업 종사자에게 미치는 방사선 피폭에 대한 평가)

  • Lee, Seung-Hyun;Jang, Yo-Jong;Kim, Tae-Yoon;Jeong, Do-Hyung;Choi, Gye-Suk
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.24 no.2
    • /
    • pp.107-114
    • /
    • 2012
  • Purpose: Unlike the existing linear accelerator with photon, proton therapy produces a number of second radiation due to the kinds of nuclide including neutron that is produced from the interaction with matter, and more attention must be paid on the exposure level of radiation workers for this reason. Therefore, thermoluminescence dosimeter (TLD) that is being widely used to measure radiation was utilized to analyze the exposure level of the radiation workers and propose a basic data about the radiation exposure level during the proton therapy. Materials and Methods: The subjects were radiation workers who worked at the proton therapy center of National Cancer Center and TLD Badge was used to compare the measured data of exposure level. In order to check the dispersion of exposure dose on body parts from the second radiation coming out surrounding the beam line of proton, TLD (width and length: 3 mm each) was attached to on the body spots (lateral canthi, neck, nipples, umbilicus, back, wrists) and retained them for 8 working hours, and the average data was obtained after measuring them for 80 hours. Moreover, in order to look into the dispersion of spatial exposure in the treatment room, TLD was attached on the snout, PPS (Patient Positioning System), Pendant, block closet, DIPS (Digital Image Positioning System), Console, doors and measured its exposure dose level during the working hours per day. Results: As a result of measuring exposure level of TLD Badge of radiation workers, quarterly average was 0.174 mSv, yearly average was 0.543 mSv, and after measuring the exposure level of body spots, it showed that the highest exposed body spot was neck and the lowest exposed body spot was back (the middle point of a line connecting both scapula superior angles). Investigation into the spatial exposure according to the workers' movement revealed that the exposure level was highest near the snout and as the distance becomes distant, it went lower. Conclusion: Even a small amount of exposure will eventually increase cumulative dose and exposure dose on a specific body part can bring health risks if one works in a same location for a long period. Therefore, radiation workers must thoroughly manage exposure dose and try their best to minimize it according to ALARA (As Low As Reasonably Achievable) as the International Commission on Radiological Protection (ICRP) recommends.

  • PDF

Development of the Home-Based Pulmonary Rehabilitation Program for Patients with Chronic Lung Disease (만성 폐질환 환자에서 재택 호흡재활치료방법 개발 연구)

  • Yoon, Seong-Ho;Na, Joo-Ok;JeGal, Yang-Jin;Kim, Myung-Wha;Kim, Eung-Suk;Shim, Tae-Sun;Lim, Chae-Man;Lee, Sang-Do;Koh, Youn-Suck;Kim, Woo-Sung;Kim, Won-Dong;Kim, Dong-Soon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.52 no.6
    • /
    • pp.597-607
    • /
    • 2002
  • Background : Even though it is well known that pulmonary rehabilitation (PR) improves exercise capacity, and the quality of life, in patients with chronic lung diseases, not many patients can attend hospital based intensive PR in Korea. The purpose of this study was to develop a method for a home-based PR program, and study its effectiveness. Materials and Methods : Twenty patients with chronic lung diseases were randomly divided into two groups : a home PR group comprising of 10 male patients, with a mean age of 70 years, and a control group comprising of 10 male patients, with a mean age of 65 years. We developed exercise programs, depending on the exercise capacity of each patient, which were easy to do at home. The PR program consisted of a 12 week period of enforced aerobic (mostly walking) and muscle strengthening exercises, as prescribed by the exercise specialist, in accordance with the functional capacity of the patient. In addition to the education, nutritional and psychiatric consultation was undertaken, and respiratory muscle training arranged. Patients visited hospital every 2 weeks for evaluation and exercise prescription. Results : All patients finished the 12 week course of therapy. Following the home PR, the endurance times and work capacity of the upper and lower extremities were significantly increased in the treatment group in comparison to the controls. The six minute working (Eds note:should) 'working' read "walking"?) distance was increased from $465{\pm}60m$ to $508{\pm}37m$ and the maximal inspiratory pressure from $72.8{\pm}27.2cmH_2O$ to $91.4{\pm}30.9cmH_2O$. The quality of life, as assessed by St Georges Respiratory Questionnaire (SGRQ), was also improved following PR. (Eds note:do you have figures for before and after, and a reference for the SGRQ?i.e. for the main paper.) Conclusion : The home PR program we developed seemed to be applicable, and effective, to most of the patients with chronic lung diseases in this study.

The Health Status of Rural Farming Women (농촌여성(農村女性)의 건강실태(健康實態)에 관한 연구(硏究))

  • Park, Jung-Eun
    • Journal of agricultural medicine and community health
    • /
    • v.15 no.2
    • /
    • pp.97-106
    • /
    • 1990
  • 1. Background Women's health and their involvement in health care are essential to health for everyone. If they are ignorant, malnourished or over-worked, the health &-their families as well as their own health will suffer. Women's health depends on broad considerations beyond medicine. Among other things, it depends upon their work in farming. their subordination to their families, their accepted roles, and poor hygiene with poorly equipped housing and environmental sanitation. 2. Objectives and Contents a. The health status of rural women : physical and mental complaints, experience of pesticides intoxication, Farmer's syndrome, experiences of reproductive health problems. b. participation in and attitudes towards housework and farming c. accessibility of medical care d. status of maternal health : fertility, family planning practice. induced abortion, and maternal care 3. Research method A nationwide field survey, based on stratified random sampling, was conducted during July, 1986. Revised Cornell Medical index(68 out of 195 items). Kawagai's Farmers Syndrome Scale, and self-developed structured questionnaires were used to rural farming wives(n=2.028). aged between 26-55. 4. Characteristics of the respondents mean age : 40.2 marital status : 90.8% married mean no. of household : 4.9 average years of education : 4.7 yrs. average income of household : \235,000 average years of residence in rural area : 36.4 yrs average Working hours(household and farming) : 11 hrs. 23 min 5. Health Status of rural women a. The average number of physical and mental symptoms were 12.4, 4.7, and the rate of complaints were 22.1%, 38.8% each. revealing complaints of mental symptomes higher than physical ones. b. 65.4% of rural women complained of more than 4 symptoms out of 9, indicating farmer's syndrome. 11.9 % experienced pesticide overdue syndrome c. 57.6% of respondents experienced women-specific health problems. d. Age and education of respondents were the variables which affect on the level of their health 6. Utilization of medical services a. The number of symptoms and complaints of respondents were dependent on the distance to where the health-care service is given b. Drug store was the most commonly utilized due to low price and the distance to reach. while nurse practitioners were well utilized when there were nurse practitioner's office in their villages. c. Rural women were internalized their subordination to husbands and children, revealing they are positive(93%) in health-care demand for-them but negative(30%) for themselves d. 33.0% of respondents were habitual drug users, 4.5% were smokers and 32.3% were alcohol drinkers. and 86.3% experienced induced-abortion. But most of them(77.6%) knew that those had negative effects on health. 7. Maternal Health Care a. Practice rate of contraception was 48.1% : female users were 90.9% in permanent and 89.6% in temporary contraception b. Induced abortions were taken mostly at hospital(86.3%), while health centers(4.7%), midwiferies(4.3%). and others(4.5%) including drug stores were listed a few. The repeated numbers of induced abortion seemed affected on the increasing numbers of symptoms and complaints. c. The first pre-natal check-up during first trimester was 41.8%, safe delivery rate was 15.6%, post-natal check-up during two months after delivery. Rural women had no enough rest after delivery revealing average days of rest from home work and farming 8.3 and 17.2. d. 86.6% practised breast feeding, showing younger and more educated mothers depending on artificial milk 8. Recommendations a. To lessen the multiple role over burden housing and sanitary conditions should be improved, and are needed farming machiner es for women and training on the use of them b. Health education should begin at primary school including health behavior and living environment. c. Women should be encouraged to become policy-makers as well as administrators in the field of women specific health affairs. d. Women's health indicators should be developed and women's health surveillance system too.

  • PDF

The Study on the Protection and Actual Condition of Using the Dental X-ray Unit (치과진단용 X선발생장치의 이용 실태 및 방어에 관한 연구)

  • Kang, Eun-Ju;Yoo, Beong-Gyu
    • Journal of radiological science and technology
    • /
    • v.23 no.2
    • /
    • pp.43-54
    • /
    • 2000
  • This paper will present the result of research which was done with 201 places on the actual condition of using dental diagnostic radiography unit and the protection of radiography. The purpose of this paper is to comprehend the actual condition of using dental x-ray unit and to protect when they do radiation work. Moreover this paper was completed to prepare basic materials that could be helpful to reduce the exposure from radiation. This paper obtains the following result. 1. On radiation photographing work in the dentist office, 50.3% of dental hygienists treat this job, and 19.2% of assistants, 10.8% of dentists, 5.6% of radiolotechnologists and 4.2% others performed this job. 2. The case that radiation worker is educated about diagnostic radiography safety supervision has been shown 14.4% and uneducated case has been shown 78.1%. 3. The result about the actual condition of using the oral diagnostic radiation per day was that a number of film which take photograph again (less than 1 exposure) was 40.3%. Normal photographing($1{\sim}10$ exposure) was 85.1% which is the highest percentage. Using the bitewing film and occlusal film was 7.0%, and 12.4% respectively. The percent that they use cephalo film and panoramic film was 16.4% 29.8% respectively. 4. Dental intra diagnostic radiography unit made in $1996{\sim}2000$ was 24.9% and the one made in $1991{\sim}1995$ was 19.9%, in $1986{\sim}1990$ was 19.9%, in 1985 was 9.5% according to the answer. On kVp, they use 60 kVp mostly(61.7%) and On mA, they use 10 mA with the highest percent(66.7%). On the dental extra diagnostic radiography units which are used for doing the extra oral radiography, the one made in $1996{\sim}2000$ was 13.4%, in $1991{\sim}1995$ was 9.5%, in $1985{\sim}1990$ was 2.0% according to the answer. They use $71{\sim}80\;kVp$ with 10.9% and $60{\sim}75\;kVP$ with 9.5%. They use less than 10 mA with 19.4% and $11{\sim}15\;mA$ with 2.5%. $16{\sim}20\;mA$ with 1.5%. But the case they exactly do not know how much mA they use or they do not have any mA was 76.6%. 5. General characteristics and the part of protection through the protective equipment by operator are completed with 89.1%. They have shown the similar difference in the relationship with age(p<0.001), experience(p<0.05) and in-patient(p<0.05). 6. When they take photographs of radiation with general quality, how far they keep the proper distance from the cone is as follows, Keeping safe distance is 12.9% according to the answer with the low percent. This result is similar with the difference related in experience(p<0.05) and work(p<0.05), the area of working(p<0.05) and in-patient(p<0.05). 7. The answer about the question-if they hold the tube head when they take photographs with general characteristics is as follows. The answer that they never hold the tube head and cone occupies 62.7% with the highest percent. It is shown the similar difference with age(p<0.05). 8. According to the study that they put on dosimeter with general characteristics is as follows. 64.7% has never put on the dosimester with the highest percent. 33.8% showed similar differences with experience(p<0.05), work(p<0.001), the area of work(p<0.005)and in-patient(p<0.001).

  • PDF