• Title/Summary/Keyword: Working distance

Search Result 498, Processing Time 0.022 seconds

A Study on Student Perception of Participation in Distance Learning : Differences Between Working and Non-Working Students (직장인과 비직장인의 원격강의 수강참여 인식 비교연구)

  • Nam Sang-Zo
    • The Journal of the Korea Contents Association
    • /
    • v.5 no.2
    • /
    • pp.1-5
    • /
    • 2005
  • It is assumed that there is difference between working students and non-working students with respect to distance learning. In this paper, we surveyed attendance in distance learning courses to verify differences in perception of faithfulness, studying time, and completion of content reading. The results are analyzed and reported. The statistical analysis indicates that working students perceive that they are less faithful to their lectures. However, the results pertaining to participation time per week and content reading showed no statistical difference between working students and non-working students.

  • PDF

Numerical Analysis of Working Distance of Square-shaped Beam Homogenizer for Laser Shock Peening

  • Kim, Taeshin;Hwang, Seungjin;Hong, Kyung Hee;Yu, Tae Jun
    • Current Optics and Photonics
    • /
    • v.1 no.3
    • /
    • pp.221-227
    • /
    • 2017
  • To apply a square-shaped beam homogenizer to laser shock peening, it should be designed with a long working distance and by considering metal targets with various shapes and textures. For long working distances, a square-shaped beam homogenizer with a long depth of focus is required. In the range of working distance, the laser beam is required to have not only high efficiency but high uniformity, in other words, a good peening quality is guaranteed. In this study, we defined this range as the working distance for laser shock peening. We have simulated the effect of some parameters on the working distance. The parameters include the focal length of the condenser lens, pitch size of the array lens, and plasma threshold of the metal. The simulation was performed through numerical analysis by considering the diffraction effect.

An Experimental Study on the Thermal Characteristics of the Working Uniform Exposed to the Radiation Heat (복사열에 노출된 작업복의 열적특성에 관한 실험적 연구)

  • 방창훈;이진호;예용택
    • Journal of the Korean Society of Safety
    • /
    • v.17 no.3
    • /
    • pp.56-60
    • /
    • 2002
  • The purpose of this study was to present the thermal characteristics of the working uniform exposed to the radiation heat. The effect of exposure time and exposure distance on the changes and the relationship between physical properties were investigated experimentally. Regardless of the kind of working uniform, the surface temperature of the working uniform with exposed time sharply increases as exposed distance is more close and the reaching time of steady state is shorter. The surface temperature of working uniform exponentially decreases as exposed distance become more distant. For the safety of the working man, it is necessary that he work far away at a fixed standard distance from the radiant heat source.

A Comparative Study of Floor Area and Average Distance of Nurse Working of Planned Courtyard in Ward (중정이 계획된 병동부 바닥면적과 간호동선 평균거리 비교 연구)

  • Kim, Jea Won;Yang, Nae Won
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.25 no.2
    • /
    • pp.7-16
    • /
    • 2019
  • Purpose: The courtyard in the ward can light and ventilate in the central space and corridor of the ward. It is possible to improve the disadvantages of the existing double-corridor ward. Also, there is the advantage in that patients are able to contact with nature indoors and cause positive activities. So, the purpose of this study is quantitatively analyze the floor area and the average distance of nurse working of the courtyard in ward. Methods: The subjects are converted through the same criteria setting. And it investigate and analyze the influence of the courtyard in the ward through the analysis of the spatial composition. Result: The factors that affected the floor area increase are the planning courtyard, the corridor type and the dispersion of the medical rooms. The average distance of nurse working is more influenced by the nursing management system of the hospital than by the courtyard. So, It can improve according to the position and number of nurse station. Implications: It can be used as a primary data for courtyard plan in the ward for positive patient environment plan considering the floor area, average distance of nurse working.

Design of micro lens array (Micro lens array 설계)

  • 홍경희
    • Korean Journal of Optics and Photonics
    • /
    • v.5 no.2
    • /
    • pp.204-211
    • /
    • 1994
  • Micro array lens systems are designed for a faximile or copy machine. The array type is hexagonal. Diameter of a lens is 0.16 mm and the distance of the center of the nearest neighbor is 0.192 mm. The magnitude of the lens system is 1:1. Working distane is 10.55 mm and the spot size is less than 0.04 mm radius on axis and 0.20 mm off-axis in case of single layer system. Working distance is 7.90 mm and the spot size is less than 0.07 mm radius on axis and 0.09 mm radius off axis in case of double layer system. Performance of single layer micro array lens system and double layer micro array lens system are compared with the characteristics of the ray fans.y fans.

  • PDF

The Optimal Condition for Scanning Large Area with a Micro-electron-column (초소형 전자칼럼의 대면적 주사 적정조건)

  • Park, Sung-Soon;Kim, Ho-Seob;Jang, Won-Kweon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.6
    • /
    • pp.481-486
    • /
    • 2007
  • In large area scanning with a micro-electron-column, the operating condition for the best resolution was investigated in factors of working distance and field of view. The resolution of a test sample was dependent on electron beam energy and scanning field size. The best resolution with single deflector was obtained at 300 V and 30 mm in the electron emitting tip voltage and a working distance, respectively. The scanning area at that condition was $13.9{\times}13.9mm^2$, linearly increased with the working distance. Double deflector was employed for larger scanning size without increasing working distance, but showed only 1.7 times larger than that of single deflector, and the resolution was inverse proportional to the scanning size.

Determination of Working Area Based on Operator's Working Comfort (사용 편의성에 기초한 작업 영역의 결정)

  • Park, Sung-Joon;Jung, Eui-Seung
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.26 no.2
    • /
    • pp.88-94
    • /
    • 2000
  • For efficient operation, vital hand controls must be easily controlled by the operator from his or her normal working position. The primary working area based on the operator-perceived working comfort was developed to serve as a design guideline to the control panel layout. Six male and four female subjects voluntarily participated in the experiment in which working comfort was measured for two types of controls - knob and lever. The operator-perceived working comfort was examined for the frontal and sagittal distances from the body center and the slope of a work surface. The response surface methodology using a central composite design was employed to develop a prediction model for operator's working comfort on each type of controls. The proposed working areas based on the actual working comfort of an operator avoided the dichotomy that considers only the reachability of control devices, and showed a distinct shape, when compared to the existing normal working areas following the Farley's concept. It was shown that the distance from the body to control devices and the slope of a work surface have a quadratic relationship to the working comfort, and that the most comfortable area for seated tasks is located at the distance of about 2∼4 cm in the sagittal direction and about 42∼43 cm in the frontal direction from the shoulder, respectively. It was also found that the working comfort varies within the working area even at the positions with an equal distance from the body. It is expected that the isocomfort working area generated in the study will be used as a useful guideline for control panel layout.

  • PDF

A Study on the Difference between Working Students and Non-Working Students in Faithfulness to the Distance (원격강의 수강시 직장인과 비직장인의 참여도 차이에 관한 연구)

  • Nam, Sang-Zo
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2004.11a
    • /
    • pp.1-4
    • /
    • 2004
  • It is usually perceived that there is conditional difference between the working students and the non-working students in distance learning. In this paper, we surveyed attendances in distance learning courses to verify the differences in faithfulness, studying time, completion of contents looking. The results are analysed and reported.

  • PDF

Braking performance of working rail-mounted cranes under wind load

  • Jin, Hui;Chen, Da
    • Wind and Structures
    • /
    • v.19 no.1
    • /
    • pp.1-14
    • /
    • 2014
  • Rail-mounted cranes can be easily damaged by a sudden gust of wind while working at a running speed, due to the large mass and high barycenter positions. In current designs, working rail-mounted cranes mainly depend on wheel braking torques to resist large wind load. Regular brakes, however, cannot satisfactorily stop the crane, which induces safety issues of cranes and hence leads to frequent crane accidents, especially in sudden gusts of wind. Therefore, it is necessary and important to study the braking performance of working rail mounted cranes under wind load. In this study, a simplified mechanical model was built to simulate the working rail mounted gantry crane, and dynamic analysis of the model was carried out to deduce braking performance equations that reflect the qualitative relations among braking time, braking distance, wind load, and braking torque. It was shown that, under constant braking torque, there existed inflection points on the curves of braking time and distance versus windforce. Both the braking time and the distance increased sharply when wind load exceeded the inflection point value, referred to as the threshold windforce. The braking performance of a 300 ton shipbuilding gantry crane was modeled and analyzed using multibody dynamics software ADAMS. The simulation results were fitted by quadratic curves to show the changes of braking time and distance versus windforce under various mount of braking torques. The threshold windforce could be obtained theoretically by taking derivative of fitted curves. Based on the fitted functional relationship between threshold windforce and braking torque, theoretical basis are provided to ensure a safe and rational design for crane wind-resistant braking systems.

Analysis and Evaluation of Slanted-edge-based Modulation Transfer Function and Focus Measurements for Optimal Assembly of Imaging Modules in Gastrointestinal Endoscopy

  • Wonju Lee;Ki Young Shin;Dong-Goo Kang;Minhye Chang;Young Min Bae
    • Current Optics and Photonics
    • /
    • v.7 no.4
    • /
    • pp.398-407
    • /
    • 2023
  • We explored a method to evaluate imaging performance for the optimal assembly of an endoscopic miniature lens and a sensor constituting an imaging module at the distal end of gastrointestinal endoscopy. For the assembly of the imaging module, the image sensor was precisely located at the focal plane when collimated light passed through the endoscopic lens. As another method, the distance between the lens and sensor was adjusted to obtain the highest focus index from images measured the star chart of the International Organization for Standardization (ISO) standard at various positions. We analyzed the slanted-edge modulation transfer function (MTF), corresponding depth of field, and number of line pairs for MTF 50% and 20% at each working distance within the range of 5-100 mm for imaging modules assembled in different ways. Assembly conditions of the imaging module with better MTF performance were defined for each working distance range of 5-30 mm and 30-100 mm, respectively. In addition to the MTF performance, the focus index of each assembled module was also compared. In summary, we examined the performance of imaging modules assembled with different methods within the suggested working distance and tried to establish the optimal assembly protocol.