• Title/Summary/Keyword: Working Gas

Search Result 705, Processing Time 0.024 seconds

Hazards of Chloroprene and the Workplace Management (클로로프렌의 유해성과 작업환경 관리)

  • Kim, Hyeon-Yeong;Lim, Cheol-Hong
    • Journal of the Korean Institute of Gas
    • /
    • v.19 no.3
    • /
    • pp.1-8
    • /
    • 2015
  • In this study, we performed risk assessment of chloroprene by hazard evaluation and workplace investigation. The chemical is used to manufacture of shoes, tires, adhesives, and classified as IARC category 2B (possibly carcinogenic to humans) and target organ systemic toxicity. It is used about 1,300 tons per year in 27 sites. It was calculated the risk of carcinogenesis with chloroprene by Monte-carlo simulation that the averages are 2,199 and 26,404 in each case of working less than 15 minutes per day with local exhaust ventilation and over 4 hours per day without local exhaust ventilation. The risk of target organ systemic toxicity are 4.10 and 169.06 with high correlation with working time to be longer and with ventilation system. Therefore, it is recommended that the local exhaust ventilation and respirators to prevent occupational cancer and target organ systemic toxicity with chloroprene. Especially it is determined that there is a need to strengthen the workplace exposure limit (TWA 10 ppm) in Korea since it is managed with TWA less than 5 ppm ($18mg/m^3$) by the United States Occupational Safety and Health Administration (OSHA) as well as it has carcinogenicity, reproductive toxicity.

Experimental and CFD Study on the Exhaust Efficiency of a Smoke Control Fan in Blind Entry Development Sites (맹갱도 굴진 작업공간내 방재팬의 화재연 배기효율에 관한 현장실험 및 CFD 연구)

  • Nguyen, Vanduc;Kim, Dooyoung;Hur, Wonho;Lee, Changwoo
    • Tunnel and Underground Space
    • /
    • v.28 no.1
    • /
    • pp.38-58
    • /
    • 2018
  • The ventilation system plays a crucial role in underground mine safety. The main objective of the ventilation system is to supply sufficient air to dilute the contaminated air at working places and consequently provide tenable environment during the normal operation, while it also should be capable of controlling the fire propagation and facilitate rescue conditions in case of fire in mines. In this study, a smoke control fan was developed for the auxiliary ventilation as well as the fire smoke exhaust. It works as a free-standing auxiliary fan without tubing to dilute or exhaust the contaminated air from the working places. At the same time, it can be employed to extract the fire smoke. This paper aims to examine the smoke control efficiency of the fan when combined with the current ventilation system in mines. A series of the site experiments and numerical simulations were made to evaluate the fan performance in blind entry development sites. The tracer gas method with SF6 was applied to investigate the contaminant behavior at the study sites. The results of the site study at a large-opening limestone mine were compared with the CFD analysis results with respect to the airflow pattern and the gas concentration. This study shows that in blind development entry, the most polluted and risky place, the smoke fan can exhaust toxic gases or fire smoke effectively if it is properly combined with an additional common auxiliary fan. The venturi effect for smoke exhaust from the blind entry was also observed by the numerical analysis. The overall smoke control efficiency was found to be dependent on the fan location and operating method.

A Study on a Precision Temperature Control for Oil cooler using ON/OFF Control Method (ON/OFF 제어방식 오일쿨러의 정밀온도 제어에 관한 연구)

  • Lee, Sang-Yun
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.14 no.2
    • /
    • pp.130-135
    • /
    • 2013
  • Recently, the needs of system performances such as working speed and processing accuracy in machine tools have been increased. Especially, the working speed increment generates harmful heat at both moving part of the machine tools and handicrafts. The heat is a main drawback to progress accuracy of the processing. Hence, a oil cooler to control temperature is inevitable for the machine tools. In general, two representative control schemes, hot-gas bypass and variable speed control of a compressor, have been adopted in the oil cooler system. In this paper, the compressor's speed are controlled to keep reference value of temperature at oil outlet. The precision processing of a machine tool is required for an oil cooler guaranteeing ${\pm}0.1^{\circ}C$ temperature control. But the oil cooler with precision temperature control is expensive. Therefore in this paper, instead of a on/off(relay) control method, a PID and phase angle electric power control method is proposed for the precision control of an oil cooler. The proposed controller is implemented and tested at the temperature of $23^{\circ}C$, $24^{\circ}C$ and $25^{\circ}C$.

Simulation of Curved Surface Forming of Steel Plate by Induction Heating (유도 가열을 이용한 강판의 곡면 성형 시뮬레이션)

  • Ryu, Hyun-Su;Kim, Ho-Kyeong;Ko, Dae-Eun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.7
    • /
    • pp.4381-4387
    • /
    • 2015
  • Ship hull is a compound curved shape and most of shipyards have been using gas heating method for the surface forming of steel plate. This traditional forming process have problems such as difficulties in heat input control and poor working conditions due to loud noise and air contamination. Recently, researches on automatic hull forming system have been conducted using high frequency induction heating method which have good control ability and favorable working environment. In this study, the induction heating simulation system for curved surface forming of steel plate was developed and induction heating experiments were performed. Based on the results of this study, efficient induction heating coil design and optimal heating conditions for the automatic hull forming system can be obtained.

Design Standard of Activated Carbon Vessel for the Intermittent Emission Sources of Volatile Organic Compounds (휘발성 유기화합물의 간헐적 배출원에 대한 활성탄 흡착 시스템 설계기준)

  • Lee, Si-Hyun;Lim, Jeong-Whan;Rhim, Young-Jun;Kim, Sang-Do;Woo, Kwang-Je;Son, Mi-Sook;Park, Hee-Jae;Seo, Man-Cheol;Ryu, Seung-Kon
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.23 no.2
    • /
    • pp.250-260
    • /
    • 2007
  • It was investigated that the emission characteristics of volatile organic compounds (VOCs) from small and medium companies located on industrial complexes in Metropolitan area. The emission characteristics are intermittent sources in which VOCs emissions are highly depends on the working condition. Optimized ventilation system to improve air quality in working area for the three typical companies were installed. Adsorption characteristics of major VOCs such as MEK, IPA, and toluene emitted front the companies were investigated for design of the activated carbon vessel as a VOCs control facility in each company. Concentration of total hydrocarbon and gas amounts needed to ventilation were also used as a design parameter. Mixed adsorbent to improve adsorption characteristics of problematic solvents like IPA and the design guideline of the activated carbon vessel have been suggested.

The Effect of Process Parameters on Sealing Quality for Ir-192 Radiation Source Capsule using Resistance Spot Welding (Ir-192 방사선원의 밀봉 용접부 품질에 미치는 저항용접 공정변수의 영향)

  • Han, In-Su;Son, Kwang-Jae;Lee, Young-Ho;Lee, You-Hwang;Lee, Jun-Sig;Jang, Kyung-Duk;Park, Ul-Jae;Park, Chun-Deuk
    • Journal of Welding and Joining
    • /
    • v.27 no.1
    • /
    • pp.65-70
    • /
    • 2009
  • Ir-192 radiation sealed sources are widely employed to the therapeutic applications as well as the non-destructive testing. Production of Ir-192 sources requires a delicate but robust welding technique because it is employed in a high radioactive working environment. A GTA(Gas Tungsten Arc) welding technique is currently well established for this purpose. However, this welding method requires a frequent replacement of the electrode, which results in the delay of the production to take a preparatory action such as to isolate the radiation sources from the working place before getting access to the welding machine. Hence, a resistance welding technique is considered as an alternative method of the GTA welding technique. The advantages of resistance welding are high welding speed and high-rate production. Also it has very long life of electrode comparing to GTA welding. In this study, the resistance welding system and proper welding conditions were established for sealing Ir-192 source capsule. As a results of various experiments, it showed that electrode displacement can be employed as a indicator to predict welding quality. We proposed two mathematical models(linear and curvilinear) to estimate electrode displacement with process parameters such as applied force, welding current and welding time by using regression analysis method. Predicting results of both linear and curvilinear model were relatively good agreement with experiment.

Air Jet Effect on Performance Improvement of Non-Contact Type Seals for Oil Mist Lubrication Systems (공기분사가 오일미스트 윤활 시스템용 비접촉 시일의 성능 향상에 미치는 영향)

  • Na, Byeong-Cheol;Jeon, Gyeong-Jin;Han, Dong-Cheol
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.9 s.180
    • /
    • pp.2159-2166
    • /
    • 2000
  • Recently, high performance machining center requires special type of sealing mechanism that prevent a leakage of oil jet or oil mist lubrication system. Sealing of oil-air mixture plays important r oles to have an enhanced lubrication for performance machining center. Current work emphasizes on investigations of the air jet effect on the protective collar type labyrinth seal. To improve sealing capabilities of conventional labyrinth seals, air jet is injected against the leakage flow. In this study, an adapted model is introduced to improve sealing capability of conventional non-contact type seals. It has a combined geometry of a protective collar type and an air jet type. Both of a numerical analysis by CFD (Computational Fluid Dynamics) and experimental measurements are carried out to verify sealing improvement. The sealing effects of the leakage clearance and the air jet magnitude aic studied in various parameters. Gas or liquid has been used as a working fluid for most of nori-contact types seals including the labyrinth seal. However, it is more reasonable to regard two-phase flows because oil mist or oil jet are used for high performance spindle's lubrication. In this study, working fluid is regarded as two phases that are mixed flow of oil and air phase. Both of turbulence and compressible flow model are also introduced in a CFD analysis to represent an isentropic process. Estimation of non-leaking property is determined by amount of pressure drop in the leakage path. Results of pressure drop in the experiment match reasonably to those of the simulation by introducing a flow coefficient. Effect of the sealing improvement is explained as decreasing of leakage clearance by air jetting. Thus, sealing effect is improved by amount of air jetting even though clearance becomes larger

Evaluation of the Appropriateness of Smoke Control Conditions of Platform at the Subway Fire by using FDS (FDS를 이용한 지하철 객실 화재 시 승강장 제연조건의 적정성 평가)

  • Kim, Ki-Sung;Song, Dong-Woo;Lee, Su-Kyung
    • Fire Science and Engineering
    • /
    • v.27 no.5
    • /
    • pp.8-14
    • /
    • 2013
  • In the subway, various fires continue to take place across the world. In the Daegu subway accident in 2003, many people were damaged by shortened visibility range caused by toxic gas and smoke. This paper, assuming that a subway fire happens in the Mandeok Station of the subway system in Busan, analyzed different smoke-spreading situations depending on the ventilation situation at its platform (opening of the train doors, operation of ventilation facilities in the tunnel, and working of fire door), using FDS. The calculation proved that it would be more effective to secure evacuation route when the ventilation facilities of the tunnel are not operated, than when they are on. And, it was also found that the case where the doors of the platform to the escape route and only the platform-facing doors of the subway car on fire office are open would be more effective to ventilation than the case where all the doors are open. And, it was found to be important that the fire doors of the platform are working properly.

Performance Design of Boiler for Waste Heat Recovery of Engine Coolant by Rankine Steam Cycle (엔진 냉각수 폐열 회수를 위한 랭킨 스팀 사이클용 보일러의 성능 설계)

  • Heo, Hyung-Seok;Bae, Suk-Jung;Hwang, Jae-Soon;Lee, Heon-Kyun;Lee, Dong-Hyuk;Park, Jeong-Sang;Lee, Hong-Yeol
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.19 no.5
    • /
    • pp.58-66
    • /
    • 2011
  • A 2-loop waste heat recovery system with Rankine steam cycles for the improvement of fuel efficiency of gasoline vehicles has been investigated. A high temperature loop(HT loop) is a system to recover the waste heat from the exhaust gas, a low temperature loop(LT loop) is for heat recovery from the engine coolant cold relatively. This paper has dealt with a layout of a LT loop system, the review of the working fluids, and the design of the cycle. The design point and the target heat recovery of the LT boiler, a core part of a LT loop, has been presented and analytically investigated. Considering the characteristics of the cycle, the basic concept of the LT boiler has been determined as a shell-and tube type counterflow heat exchanger, the performance characteristics for various design parameters were investigated.

Design of Integrated Safery System for Sealed Places (밀폐된 공간을 위한 통합안전시스템의 설계)

  • Jeong, Min-Seung;Lee, Chang-Shin;Cho, Woo-Hyeon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.23 no.1
    • /
    • pp.97-102
    • /
    • 2019
  • Disaster accidents at industrial sites have been increasing every year. In shipyards there are countless enclosed spaces causing issues like harmful-toxic gases stuck in those sealed areas. And due to such special and complicated structures of the working places with many layers of walls separating each other, there exist more issues of communication with workers trapped inside when accidents happen. Under this circumstance there must be a huge difficulty to evacuate or rescue the workers in case of any disaster. Therefore, in this paper, We would like to introduce the "integrated safety system" to more effectively deal with the problems and prevent such disasters in tough working environments. The suggested integrated safety system can prevent accidents in advance because it can control the data on the location of the workers in real time and the numerical values such as gas, oxygen, and carbon dioxide generated in the workplace in real time.