• 제목/요약/키워드: Working Gas

검색결과 708건 처리시간 0.032초

Pt/MoO$_3$가스센서의 수소 감지 특성 (H$_2$ Gas Sensing Properties of Pt/MoO$_3$ Gas Sensor)

  • 최용일;김창교;김진걸;한득영
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1996년도 춘계학술대회 논문집
    • /
    • pp.118-122
    • /
    • 1996
  • 1wt% Pt/MoO$_3$ gas sensors for detecting H$_2$ gas were fabricated by the pressed pellet method and surface structures of Pt/MoO$_2$ were investigated by TEM and XRD. It was observed that as the calcination temperature is increased, the overlayers of MoO$_3$ on Pt are produced, but the Cl content in PtCl$\_$x/ are decreased. H$_2$ gas sensing properties in N$_2$ ambient and in air ambient were investigated, respectively, and Pt/MoO$_3$ had high sensitivity at low working temp ; 7.8% at 50$^{\circ}C$, 97.7% at 100$^{\circ}C$, 97.1% at 150$^{\circ}C$ when the specimens are treated at 400$^{\circ}C$, and 99.6% at 150$^{\circ}C$ when they are treated at 200$^{\circ}C$. It shows the development of a low-power type sensor is possible by using Pt/MoO$_3$.

  • PDF

SiC 마이크로 히터가 내장된 극한 환경용 NO 센서의 제작과 특성 (Fabrication of NO sensor integrated SiC micro heaters for harsh environments and its characteristics)

  • 김강산;정귀상
    • 센서학회지
    • /
    • 제19권3호
    • /
    • pp.197-201
    • /
    • 2010
  • This paper describes the fabrication and characteristics of a NO sensor using ZnO thin film integrated 3C-SiC micro heater based on polycrystalline 3C-SiC thin film of operation in harsh environments. The sensitivity, response time, and operating properties in high temperature and voltages of NO sensors based SiC MEMS are measured and analyzed. The sensitivity of device with pure ZnO thin film at the heater operating power of 13.5 mW ($300^{\circ}C$) is 0.875 in NO gas concentration of 0.046 ppm. In the case of Pt doping, the sensitivity of at power consumption of 5.9 mW ($250^{\circ}C$) was 1.92 at same gas flow rate. The ZnO with doped Pt was showed higher sensitivity, lower working temperature and faster adsorption characteristics to NO gas than pure ZnO thin film. The NO gas sensor integrated SiC micro heater is more strength than others in high voltage and temperature environments.

불응축가스 주입량에 따른 VCHP의 열제어 특성 (Analysis of Thermal Control Characteristics of VCHP by the Charging Mass of Non-Condensible Gas)

  • 서정세;박영식;정경택
    • 설비공학논문집
    • /
    • 제17권12호
    • /
    • pp.1139-1144
    • /
    • 2005
  • This study has been performed to investigate the thermal performance of variable conductance heat pipe (VCHP) with meshed wick. The length of condenser portion in a VCHP is varied by the expansion of inert gas with the operation temperature, and the heat transport capacity is thus varied with the operating temperature. In this study, numerical evaluation of the VCHP is made for the thermal performance of VCHP, based on the diffusion model of inert gas. Water is used as a working fluid and nitrogen as a control inert gas in the copper tube. As a result, the thermal performance of VCHP has been compared with that of constant conductance heat pipe (CCHP) according to the variation of operation temperature. Maximum heat transport capacity of VCHP is mainly presented for operation temperature and the variation of operation temperature is also presented for heat transfer rate of VCHP.

선박용 디젤엔진의 배기가스 열회수 시스템 (II) - R245fa 및 Water 의 작동유체에 대한 엑서지 분석 - (Exhaust-Gas Heat-Recovery System of Marine Diesel Engine (II) - Exergy Analysis for Working Fluids of R245fa and Water -)

  • 최병철;김영민
    • 대한기계학회논문집B
    • /
    • 제36권6호
    • /
    • pp.593-600
    • /
    • 2012
  • 대형 선박의 추진용 디젤엔진에서 버려지는 배기가스의 열을 회수하기 위한 랭킨사이클이 적용된 발전시스템에 대하여 R245fa 및 water의 작동유체에 따른 그 엑서지 특성을 분석하였다. 그 이론적인 계산 결과로, R245fa에 대하여 터빈입구의 압력이 증가할수록 엑서지 효율 및 시스템의 엑서지 효율이 증가하였고, 엑서지 파괴율은 주로 응축기 및 증발기에서 상대적으로 높게 나타났다. 그리고 질량유량의 증가에 따라 시스템의 엑서지 효율이 증가하는 특성을 보였다. Water의 경우에, 증발기에서의 엑서지 파괴율은 R245fa의 경우와 유사하게 나타났지만, 터빈입구의 압력 및 질량유량 비율의 변동에 대하여 열원에 대한 엑서지 손실률이 가장 큰 폭으로 변동하였다.

저온 열원과 LNG 냉열을 이용하는 암모니아-물 동력 사이클의 열역학적 성능 해석 (Thermodynamic Performance Analysis of Ammonia-Water Power Generation System Using Low-temperature Heat Source and Liquefied Natural Gas Cold Energy)

  • 김경훈;김경천
    • 대한기계학회논문집B
    • /
    • 제38권6호
    • /
    • pp.483-491
    • /
    • 2014
  • 본 연구에서는 현열 형태의 저온 열원과 LNG의 냉열을 이용하는 복합 동력 생산시스템에 대한 열역학적 성능 해석을 수행하였다. 시스템의 작동유체로서 암모니아-물의 비공비 혼합물을 고려하였으며 재생기가 없는 기본 사이클과 있는 재생 사이클의 경우를 비교 해석하였다. 작동유체의 암모니아 농도나 응축 온도에 따라 시스템의 순생산일, 엑서지 파괴, 열효율이나 엑서지 효율 등에 미치는 다양한 영향에 대해 분석하고 논의하였다. 해석 결과는 시스템의 성능 특성이 작동유체의 암모니아 농도나 응축 온도에 따라 민감하게 변화하며, 열원유체 단위질량당 순생산일은 기본 사이클이 유리하나 열효율이나 엑서지 효율은 재생 사이클이 유리하다는 사실을 보여준다.

치과기공사들의 건강관리 실태 및 인식수준에 관한 조사 연구 (A Study on the Health Management of Dental Technicians and Their Awareness of the Same)

  • 최운재
    • 대한치과기공학회지
    • /
    • 제22권1호
    • /
    • pp.113-128
    • /
    • 2000
  • The purpose of this study was to serve as a basis for the development of dental technology and for creating a condition that dental technicians could work with pride and right values, by examining what problems there were in their health care, what they thought about them, and how the problems could be solved, The findings of this study were as below: 1. The most serious and harmful element in dental technology workshop was a dust(57.5%) and a noise(33.3%). 2. Approximately 99.0% of the dental technicians investigated made a complain of air pollution caused by noise. Their opinion on a possible measure to remove noise air pollution was that the noise-generating machine should be replaced(64.1%) or that it should be isolated(28.8%). 3. 76.0% complained air pollution cause by dust deteriorates their working efficiency. As a way to eliminate it, they suggested a dust chamber(35.3%) or an air cleaner(27.5%) should be installde. 4. About 80% made a complain of gas air pollution. The most common related symptom was a headache(56.9%). They thought that gas-generating machine should be isolated(39.9%) or that an air purifier should be prepared(33.3%). 5. The largest impact of heat and light on their body was weakening their eyesight(56.9%). 47.1% got burn once though four times, and 34.3% did five times or more. The way to prevent them was to install an automatic casting machine(66.0%) or use protective glasses(28.1%). 6. Approximately 47.7% were considering a change of occupation, and the most common reason was heavy work(23.5%), followed by poor prospect(21.6%) and working environment(19.0%) in the order named. 7. 88.9% responded they were likely to have an occupational disease. Their idea about the proper frequency of regular health examination was once a year(53.6%), or once per every six months(41.8%). 8. The field they were most interested in was health care(39.2%), followed by academic research activities(31.4%). This fact indicated it's most urgently required to improve their working environment.

  • PDF

Gasoline 취급 사업장의 작업환경 측정 및 위해성 평가 (Working Environment and Risk Assessment of Gasoline in Workplace)

  • 김현영
    • 한국가스학회지
    • /
    • 제18권4호
    • /
    • pp.1-7
    • /
    • 2014
  • 화학물질로부터 근로자의 건강보호를 위해 사용량이 많으나 작업환경 및 유해성 평가 자료가 부족한 gasoline에 대해 유해성(hazards)을 조사하고 국내 취급실태 및 일부 취급 사업장의 작업환경 측정을 통해 위해성(risk assessment)을 평가하였다. 연구결과 gasoline은 생식독성 추정 및 생식세포 변이원성 물질인 1B, 그리고 IARC Group 2B, ACGIH A3 물질이었다. 작업환경 측정결과는 TLV-TWA 기준 $900mg/m^3$미만이었으며, 유해성 평가결과 발암 $RfC_{(Worker)}$$0.3mg/m^3$, 만성흡입독성 $RfC_{(Worker)}$$2.7mg/m^3$, 발달독성 $RfC_{(Worker)}$$2.7mg/m^3$이었다. 그리고 위험도 평가에서 발암성은 459, 만성흡입독성은 51, 발달독성은 51이었으며, 이를 토대로 한 gasoline의 위험도는 1을 초과하는 물질로 평가되었다.

CO 가스 산화를 위한 백금/다공성 골드 전극의 개발 (Preparation of Pt/porous Gold Electrode for CO Oxidation)

  • 신소향;김휘로;오천석;고재욱;김영훈
    • 한국가스학회지
    • /
    • 제15권4호
    • /
    • pp.27-32
    • /
    • 2011
  • 가스 설비의 증가와 함께 가스 사용시 안전관리가 중요해 지고 있다. 그 일환으로 국가적인 차원에서 U-safety 시스템 도입이 추진되고 있으며, 이를 위해서는 실시간으로 현장에서 가스 누출에 대한 검지가 가능해야 한다. 탄화수소류로 주로 구성된 가스의 누출 감지는 열저항을 이용하는 방식이지만, 도관에 함께 매설될 시에는 폭발 가능성으로 인해 적용이 불가하다. 이에 상온에서 메탄이나 일산화탄소와 같은 탄화수소류를 전기화학적 촉매 반응으로 검지할 수 있는 방법이 필요하다. 본 연구에서는 다공성 골드 분말을 팰렛 형태로 제조하여 백금 나노입자를 전해 도금법으로 도핑하여, CO의 $CO_2$ 산화 반응을 유도할 수 있는 촉매 전극을 제조하였다. Pt/PAu 전극의 경우, 약 21%의 CO 전환률을 보여서 탄화수소류의 상온 촉매전환과 함께 전기화학적 센싱이 가능함을 보였다. 이는 추후 메탄 가스 검지에 적용할 수 있는 여지를 마련했다고 판단된다.

모작업장에서 휘발성 유기오염물질의 분석과 근로자들의 건강위해성 평가 (Health Risk Assessment and Analysis on the Volatile Organic Compounds in Some Workplace)

  • 이효민;김명수;최시내;윤은경;박종세
    • Journal of Preventive Medicine and Public Health
    • /
    • 제30권3호
    • /
    • pp.530-539
    • /
    • 1997
  • This study was conducted to assess the health risk on the volatile organic compounds such as toluene, xylene, and styrene in painting workplace. It was monitored through personal air sampling during working time in selected 5 workplaces and analysed using gas chromatography. For the settlement of exposure situation, there were regarded working conditions such as working hours, yearly working days, and working years. Also, Monte-Carlo simulation was used for the induction of hazard index using toxicity value from IRIS(Integrated risk information system) database. The results of risk assessment were summarized as follows. 1. The air concentration of toluene was $7.096{\pm}15,644ppm,\;2.586{\pm}4.275ppm\;for\;xylene,\;1.914{\pm}5.320ppm$ for styrene in blast painting workplaces. The level of toluene was different significantly compared with the level of xylene and styrene. 2. Computated chronic daily intake values of 95th percentile on toluene, xylene and styrene treated by Monte-Carlo simulation were 9.616, 3.567, 2.782 mg/kg/day, respectively. 3. Computated hazard index values of 75th percentile on toluene, xylene and styrene treated by Monte-Carlo simulation were 3.5, 1.0 and 1.6, respectively. Adverse health effects on the toluene, xylene and styrene would be expected by working exposure in selected 5 workplaces since the hazard indices of three compounds were exceeded 1 in the surroundings of 75th percentile though having the low emerged frequency.

  • PDF

$LiBr-H_2O$계 흡수식냉동기의 부식에 미치는 LiBr 농도의 영향 (The Effect of LiBr Concentration on Corrosion of Absorption Refrigeration Systems Using $LiBr-H_2O$ Working Fluids)

  • 임우조;정기철
    • 한국가스학회지
    • /
    • 제5권4호
    • /
    • pp.33-39
    • /
    • 2001
  • 흡수식냉동기의 작동매체로 사용되고 있는 LiBr수용액 중에서 각 구성재료인 일반구조용 압연강재, 동 및 동합금재인 Ai-Ni bronze의 부식거동에 관한 연구를 하기 위하여, 여러 가지 농도의 LiBr 수용액 중에서 각 재료에 대한 분극실험을 실시하여 부식거동을 고찰한 결과 다음과 같은 결론을 얻었다. 1) 수용액의 LiBr 농도가 증가할수록 각 재료의 분극저항은 낮아지고, 개로전위는 비전 위화되면서 부식전류밀도는 높게 배류된다. 2) 일반구조용 압연강재의 개로전위는 동 및 Al-Ni bronze의 개로전위보다 비전위화되면서 부식전류밀도는 더 높게 배류된다. 3) 동 및 Al-Ni bronze에 대한 $62\%$ LiBr 수용액 중에서의 양극분극은 활성태로 지속되지만, 천연해수 중에서의 양극분극은 활성태가 지속되다가 부동태화전류가 나타난다.

  • PDF