• Title/Summary/Keyword: Working Device

Search Result 557, Processing Time 0.027 seconds

Design and control of the precision heat actuator using thermoelectric device (열전소자를 이용한 정밀 열구동기구의 설계 및 제어)

  • 서장렬;김선민;이선규
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.395-398
    • /
    • 1997
  • In the modem manufacturing system, to achieve the unmanned automation, the stability of accuracy is required through a long working period. The thermal deformation of precision machine is predominant in this long time stability. While grinding slender and long workpiece at cylindrical grinding machine, we support workpiece using steadies to prevent the vibration of workpiece. The thermal deformation of the machine by grinding and internal heat source cause processing errors, so the steadies for compensating the thermal deformation in real time are strongly needed. In order to compensate these thermal deformation and grinding processing errors, the device to determine the precise positioning having the stroke of 10.mu.m is necessary. This paper suggests design and make the device to determine the precise positioning using thermoelectric device, to investigate the control characteristics and presents the heat actuator will be very useful in machine tool.

  • PDF

A Working-set Sensitive Page Replacement Policy for PCM-based Swap Systems

  • Park, Yunjoo;Bahn, Hyokyung
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.17 no.1
    • /
    • pp.7-14
    • /
    • 2017
  • Due to the recent advances in Phage-Change Memory (PCM) technologies, a new memory hierarchy of computer systems with PCM is expected to appear. In this paper, we present a new page replacement policy that adopts PCM as a high speed swap device. As PCM has limited write endurance, our goal is to minimize the amount of data written to PCM. To do so, we defer the eviction of dirty pages in proportion to their dirtiness. However, excessive preservation of dirty pages in memory may deteriorate the page fault rate, especially when the memory capacity is not enough to accommodate full working-set pages. Thus, our policy monitors the current working-set size of the system, and controls the deferring level of dirty pages not to degrade the system performances. Simulation experiments show that the proposed policy reduces the write traffic to PCM by 160% without performance degradations.

The package loading equipment development cutting both ends in the process of packaging lumber for improving the working environments (작업환경개선을 위한 목재포장공정에 있어서의 양끝절단포장적재장치 개발)

  • Kang, Ji-Ho;Hong, Dong-Pyo
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.29 no.1
    • /
    • pp.135-142
    • /
    • 2006
  • The package loading process of tile lumbering industry is an operation that after a pair of workers binds three or six lumber into a unit and cut the both ends of the lumber, carry and pack and load the weight cargo of 30-50kg. The package loading process causes lots of noise and wood dust when the lumber are cut and brings about the main cause of the musculoskeletal disorder when workers carry the heavy goods. Therefore, we developed the monolithic package loading equipment cutting both ends that is enable to improve the working method and environments of the existing package loading process. The noise and wood dust were reduced by developing the device and the main cause of shirking duties on working place was solved by preventing the musculoskeletal disorder and improving the working environments as excluding the work of carrying heavy goods.

Design of SDRAM Controller in HDL (HDL을 이용한 SDRAM Controller의 설계)

  • 김용국;오경욱;이영희
    • Proceedings of the IEEK Conference
    • /
    • 1999.06a
    • /
    • pp.753-756
    • /
    • 1999
  • In this research we designed and synthesized an effective Synchronous DRAM controller for Interleaved Column Mode Access with VHDL. When target device was ALTERA CPLD MA$\times$712 105 logic cells were used. The result of the simulation at 66MHz clock operation, the clock-to-output time t$_{co}$ was 4.5㎱ and the SDRAM controller was in good working order.r. good working order.

  • PDF

Study on Optimal Working Conditions for Picking Head of Self-Propelled Pepper Harvester by Factorial Test

  • Kang, Kyung-Sik;Park, Hoon-Sang;Park, Seung-Je;Kang, Young-Sun;Kim, Dae-Cheol
    • Journal of Biosystems Engineering
    • /
    • v.41 no.1
    • /
    • pp.12-20
    • /
    • 2016
  • Purpose: Pepper prices have risen continuously because of a decrease in cultivation area; therefore, mechanical harvesting systems for peppers should be developed to reduce cost, time, and labor during harvest. In this study, a screw type picking head for a self-propelled pepper harvester was developed, and the optimal working conditions were evaluated considering helix types, winding directions of helix, and rotational speeds of the helix. Methods: The screw type was selected for the picking head after analyzing previous studies, and the device consisted of helices and a feed chain mechanism for conveying pepper branches. A double helix and a triple helix were manufactured, and rotational speeds of 200, 300, and 400 rpm were tested. The device was controlled by a variable speed (VS) motor and an inverter. Both the forward and reverse directions were tested for the winding and rotating directions of the helix. An experiment crop (cultivar: Longgreenmat) was cultivated in a plastic greenhouse. The test results were analyzed using the SAS program with ANOVA to examine the relationship between each factor and the performance of the picking head. Results: The results of the double and triple helix tests in the reverse direction showed gross harvest efficiency levels of 60-95%, mechanical damage rates of 8-20%, and net marketable portion rates of 50-80%. The dividing ratio was highest at a rotational speed of 400 rpm. Gross harvest efficiency was influenced by the types of helix and rotational speed. Net marketable portion was influenced by rotational speed but not influenced by the type of helix. Mechanical damage was not influenced by the type of helix or rotational speed. Conclusions: Best gross harvest efficiency was obtained at a rotational speed of 400 rpm; however, operating the device at that speed resulted in vibration, which should be reduced.

Evaluation of Soil Loss with Surface Covering Methods Using Strip Tillage Seeding Device

  • Lee, Jeong-Tae;Ryu, Jong-Soo;Lee, Gye-Jun;Jung, Hee-Ju;Kim, Jeom-Soon;Park, Seok-Ho
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.47 no.6
    • /
    • pp.425-431
    • /
    • 2014
  • Most fields in highland areas are covered with rye or hairy vetch for conservation during a fallow. However, using cover crops needs an effort to sow, and this makes top soil more vulnerable to loss due to surface disturbances. The aims of this study were to develop an automatic seeding-regulator device using a low-price, extensive-use GPS sensors and a DC motors and to evaluate a working efficiency of it after adaptation to partial tillage machine for reducing seeding effort. The amount of runoff water and soil loss was evaluated with partial tillage and simultaneous-seeding after harvesting soybean, in 17% slope lysimeters. In results, the seeding amount with the machine speed was stable between $0.5{\sim}0.8m\;s^{-1}$ of working sections. The automatic control device of seeding-rate could be enough to solve the slip problems of power selecting supply system or five four-wheel drive device. In partial tillage and simultaneous seeding, runoff water was 11.6% ($1.8m^3ha^{-1}$) of the scatter-seeding control ($15.5m^3ha^{-1}$) and soil loss was 13.2% ($7kg\;ha^{-1}$) of the scatter-seeding control ($53kg\;ha^{-1}$). These results suggest that partial tillage and simultaneous-seeding methods are very effective in decreasing work effort and soil loss of sloped land.

Effect of Sputtering Working Pressure on the Optical and Electrical Properties of InZnO Thin-Film Transistors (스퍼터링 공정 압력이 InZnO 박막트랜지스터의 광학 및 전기적 특성에 미치는 영향)

  • Park, Ji-Min;Kim, Hyoung-Do;Jang, Seong Cheol;Kim, Hyun-Suk
    • Korean Journal of Materials Research
    • /
    • v.30 no.4
    • /
    • pp.211-216
    • /
    • 2020
  • Amorphous In-Ga-Zn-O (a-IGZO) thin film transistors, because of their relatively low mobility, have limits in attempts to fulfill high-end specifications for display backplanes. In-Zn-O (IZO) is a promising semiconductor material for high mobility device applications with excellent transparency to visible light region and low temperature process capability. In this paper, the effects of working pressure on the physical and electrical properties of IZO films and thin film transistors are investigated. The working pressure is modulated from 2 mTorr to 5 mTorr, whereas the other process conditions are fixed. As the working pressure increases, the extracted optical band gap of IZO films gradually decreases. Absorption coefficient spectra indicate that subgap states increase at high working pressure. Furthermore, IZO film fabricated at low working pressure shows smoother surface morphology. As a result, IZO thin film transistors with optimum conditions exhibit excellent switching characteristics with high mobility (≥ 30㎠/Vs) and large on/off ratio.

A Study on Job Satisfaction, Working Environment and Turnover Intention of Dental Technicians in Daegu Area (대구지역 치과기공사의 직무만족 및 작업환경과 이직의도에 관한 연구)

  • Park, Hong-Ryurn;Moon, Seon-Jeong
    • The Korean Journal of Health Service Management
    • /
    • v.6 no.4
    • /
    • pp.191-204
    • /
    • 2012
  • The purpose of this study was to provide basic data necessary for improvement by closely examining factors of having influence upon dental technicians' turnover. Questionnaire survey was conducted of 204 dental technicians who work at dental hospitals, clinics and dental laboratory rooms in Daegu area. The following conclusions were obtained. The satisfaction with job was high in job position in more than co-representative, in the whole and other task, and in less than 9 hours as for working hours. In the satisfaction with working environment, dissatisfaction was high in women, in the working career with 7~9 years, in chief level as for the job position in charge, in being responsible for porcelain in case of the duty field, and in more than 10 people as for the number of employees. The higher satisfaction with job satisfaction and working environment led to the lower turnover intention. Turnover intention was low in case of having ventilation fan & dust collector desk and in case of being well ventilated inside the workshop. As the above results, it is considered to be necessary for arranging institutional device of protecting dental technicians' health and reducing turnover through improving working environment such as forming comfortable environment of using the dust-collecting facilities and the ventilation facilities, wearing suitable individual protective gear and arranging the rest space.

New Graphene Electronic Device Structure for High Ion/Ioff Ratio

  • Jeong, Hyeon-Jong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.112-112
    • /
    • 2012
  • Graphene has been considered as one of the potential post Si-materials due to its high mobility. [1] However, since graphene is semi-conductor with zero band gap, it is difficult to achieve high Ion/Ioff ratio, one of the most important requirements for commercial devices. There have been many attempts to open its band gap for high Ion/Ioff ratio, but most of them end up lowering the mobility. [2-5] Thus, we proposed and demonstrated a new device structure for graphene transistor based on one of the unique properties of graphene for high Ion/Ioff: using this approach, we were able to achieve the ratio over $10^5$. [6] Our device has several major advantages over previously proposed graphene based electronic devices. Since our device does not alter the given properties of graphene, such as opening the band gap, it has no fundamental issues on mobility degradations. In addition, our device is fully compatible with current Si technology and we were able to fabricate the devices with 6 inch wafer scale with CVD (Chemical Vapor Deposition) grown graphene. In this presentation, we will discuss about the details of our graphene device including the device structure and the detailed understanding of working mechanism. We will present device characteristics including I-V curves with $10^5$ on/off ratio. We will also present the performance of an inverter based on our devices. Finally, we will discuss the current issues and their potential solutions.

  • PDF

Evaluation of radiological safety according to accident scenarios for commercialization of spent resin mixture treatment device

  • Choi, Woo Nyun;Byun, Jaehoon;Kim, Hee Reyoung
    • Nuclear Engineering and Technology
    • /
    • v.54 no.7
    • /
    • pp.2606-2613
    • /
    • 2022
  • Spent resin often exceeds radiation limits for safe disposal, creating a need for commercial-scale treatment techniques to reduce resin radioactivity. In this study, the radiological safety of a commercialized spent resin treatment device with a treatment capacity of 1 ton/day was evaluated. The results confirm that the device is radiologically safe in the event of an accident. This device desorbs 14C from the spent resin, allowing disposal as low-level waste instead of intermediate-level waste. The device also reduces overall waste by recycling the extracted 14C. Potential accident scenarios were explored to enable dose assessments for both internal and external exposure while preventing further spillage of the device and processing the spilled resin. The scenarios involved the development of a surface fracture on the resin mixture separator and microwave systems, which were operated under pressure and temperature of 0-6 bar and 0-150 ℃, respectively. In the case of accidents with separator and microwave device, the maximum allowable working time of worker were derived, respectively, considering external and internal exposures. When wearing the respirator corresponding to APF 50, in the case of the microwave device accident scenario, the radiological safety was confirmed when the maximum worker worked within 132.1 h.