• Title/Summary/Keyword: Work capacity evaluation

Search Result 153, Processing Time 0.024 seconds

Assessment of Educational Conditions for 28 National Universities in South Korea

  • Jeong, Dong-Bin
    • Asian Journal of Business Environment
    • /
    • v.7 no.1
    • /
    • pp.25-29
    • /
    • 2017
  • Purpose - In this paper, we categorize and segment the 28 national universities in South Korea and measure the degree of dissimilarity (or similarity) between pairs of ones by using dissimilarity distance matrix and cluster analysis, respectively, based on the seven quantitative evaluation of educational conditions (percentage of small-scale courses, percentage of lecture by the faculty, collection of books per student, material purchase per student, percentage of building capacity, percentage of real estate capacity and rate of accommodation) in 2015. In addition, multidimensional scaling (MDS) techniques can obtain visual representation for exploring patterns of proximities among 28 national universities based on seven attributes of educational conditions. Research design, data, and methodology - This work is carried out by the 2015 Announcement of University Information, which is provided by Ministry of Education in South Korea and utilized by multivariate analyses with CLUSTER, PROXIMITIES and ALSCAL modules in IBM SPSS 23.0. Results - We make certain that 28 national universities can be categorized into five clusters which have similar traits by applying two-stage cluster analysis. MDS is utilized to perform positioning of grouped places of cluster and 28 national universities joining every cluster. Conclusions - Both types and traits of each national university can be relatively assessed and practically utilized for each university competitiveness based on underlying results.

Experimental Study on Combined Ocean Thermal Energy Conversion with Waste Heat of Power Plant

  • Jung, Hoon;Jo, Jongyoung;Chang, Junsung;Lee, Sanghyup
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.5 no.3
    • /
    • pp.215-222
    • /
    • 2019
  • This work is experimental study of 10 kW specialized Combined Ocean Thermal Energy Conversion. We propose a C-OTEC technology that directly uses exhaust thermal energy from power station condensers to heat the working fluid (R134a), and tests the feasibility of such power station by designing, manufacturing, installing, and operating a 10 kW-pilot facility. Power generation status was monitored by using exhaust thermal energy from an existing power plant located on the east coast of the Korean peninsula, heat exchange with 300 kW of heat capacity, and a turbine, which can exceed enthalpy efficiency of 45%. Output of 8.5 kW at efficiency of 3.5% was monitored when the condenser temperature and seawater temperature are $29^{\circ}C$ and $7.5^{\circ}C$, respectively. The evaluation of the impact of large-capacity C-OTEC technology on power station confirmed the increased value of the technology on existing power generating equipment by improving output value and reducing hot waste water. Through the research result, the technical possibility of C-OTEC has been confirmed, and it is being conducted at 200 kW-class to gain economic feasibility. Based on the results, authors present an empirical study result on the 200 kW C-OTEC design and review the impact on power plant.

Neuro Fuzzy System for the Estimation of the Remaining Useful Life of the Battery Using Equivalent Circuit Parameters (등가회로 파라미터를 이용한 배터리 잔존 수명 평가용 뉴로 퍼지 시스템)

  • Lee, Seung-June;Ko, Younghwi;Kandala, Pradyumna Telikicherla;Choi, Woo-Jin
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.26 no.3
    • /
    • pp.167-175
    • /
    • 2021
  • Reusing electric vehicle batteries after they have been retired from mobile applications is considered a feasible solution to reduce the demand for new material and electric vehicle costs. However, the evaluation of the value and the performance of second-life batteries remain a problem that should be solved for the successful application of such batteries. The present work aims to estimate the remaining useful life of Li-ion batteries through the neuro-fuzzy system with the equivalent circuit parameters obtained by Electrochemical Impedance Spectroscopy (EIS). To obtain the impedance spectra of the Li-ion battery over the life, a 18650 cylindrical cell has been aged by 1035 charge/discharge cycles. Moreover, the capacity and the parameters of the equivalent circuit of a Li-ion battery have been recorded. Then, the data are used to establish a neuro-fuzzy system to estimate the remaining useful life of the battery. The experimental results show that the developed algorithm can estimate the remaining capacity of the battery with an RMSE error of 0.841%.

DESIGN AND PERFORMANCE EVALUATION OF A CABBAGE LOADER

  • Chang, Y.C.;Cho, S.I.;Yeo, Y.W.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2000.11b
    • /
    • pp.480-488
    • /
    • 2000
  • Cabbage is the most important vegetables in korea. The cabbage production was based on arduous human labor. A comprehensive research for substituting the human work by machines has been performed at present. In general, cabbage is cultivated on hillside in korea. The harvested cabbage in a field and carrying it to a vehicle for transportation are very laborious work. Hand labor in cabbage transportation to the market damages the quality of cabbage and is also a cause to increase the cost of cabbage production. This study was to design and evaluate a prototype cabbage loader for deserving efficient and safe transportation of cabbage. The developed cabbage loader was a semi-tracked vehicle operated by a hydraulic system, allowing the safe transporting and the loading of cabbage in a steep field. The maximum loading capacity of the loader was 1.0 ton. By using safety devices attached to the loader, the static slopes were 34.0% and 37.4% for the left and the rear roll-over, respectively. The maximum field speed was about 6km/hr with two cabbage pallets of 750kg at a 25% inclined field. The field capacity was about 35 pallets/hr in case of picking up, carrying and unloading two cabbage pallets. The field efficiency of the loader was analyzed to be more than 8 times in comparison of the conventional human labor. The developed loader would be applied for loading and carrying the other vegetables due to the similarity of operations. The study suggested a standard approach to the design of field machines operated in a steep field.

  • PDF

Evaluation of Central Commissary School Foodservice Operations' Practices and their Dietitians' Job Duties (공동조리 급식학교의 운영실태 및 영양사 업무 평가)

  • Kwak, Tong-Kyung;Kim, Jeong-Lee
    • Journal of the Korean Society of Food Culture
    • /
    • v.9 no.2
    • /
    • pp.159-170
    • /
    • 1994
  • Central commissary school foodservice operations' practices and their dietitians' job duties were assessed and compared with those of their counterpart of conventional school foodservice operations to find out strategies for early settlement and better management for commissary system. Survey qestionnaires consisted of general background, employees' work schedule and dietitians' job duties. 12 commissary schools(out of 22 existing in Korea) and 77 conventional schools from Kyungkido were participated in the survey. The results of this study can be summarized as follows: 1. Central commissary school foodservice was presently utilized at 5 schools from islands type, 11 schools from rural type, and 6 schools from urban type, consisting total of 22 commissary schools, and 52 satellite schools. 2. Dietitians were evenly employed with their experiences, 55.5% were those with less than 2 years of experience, 44.6% were those with more than 2 years of experience. 3. Commissary schools employed more full-time empolyees$(1.8{\pm}0.7)$ than conventional schools$(0.3{\pm}0.5)$, however as far as the production capacity was concerned, only the part-time employees played significant roles(p<.01). Regardless of the number of students, an absolute number of full-time employees were employed, and their duties were not carried out efficiently. The part-time employees of commissary schools performed more loaded work compared to their counterparts in conventional schools. 4. Out of the dietitians' foodservice duties, 'basic food service production$(3.9{\pm}0.7)$' were carried out adequately, whereas 'nutrition education and advertisement$(2.5{\pm}0.6)$' and 'administrative affairs and information related duties$(2.8{\pm}0.9)$' were not. In order to enhance their working capacity, systematic organizational reforms are imminent. 5. Survey results also showed that dietitians performed less duties at satellite school than at the central commissary. This indicates more systematic foodservice management practices are urgently needed.

  • PDF

A Study on Developing the Evaluation Framework for Industrial Information Systems and its Application (기업정보화 수준평가 시스템 개발 및 적용사례)

  • 이학주;임춘성
    • Proceedings of the CALSEC Conference
    • /
    • 2002.01a
    • /
    • pp.65-85
    • /
    • 2002
  • In order to achieve competitive business goals, every enterprise needs to evaluate the current level of IS(information systems) performance and their utilization. The evaluation is to measure technical capacity and operational capability of enterprise information systems and to diagnose their effectiveness of business goals and efficiency of resources. Furthermore, organizations need to apply information technology(IT) proactively instead of reactively. However. it is usually very difficult for an enterprise to accumulate knowledge acquired during construction of the information systems and apply it to maintain and evaluate them. Also. most researches regarding evaluation are limited in some parts of evaluation fields, the most prominent being lack of the entire views and integrated relationships of enterprise activities. This dissertation develops an integrated evaluation system, which is based on the continuous improvement model of information systems performance. that effectively measures the level of enterprise information systems performance. enabling enterprises to achieve their goals of information systems and related business strategies. The contents of this work are composed of the continuous improvement model of information systems performance, an integrated evaluation system for IS performance and case study.

  • PDF

Fixed Relays for Next Generation Wireless Systems - System Concept and Performance Evaluation

  • Pabst Ralf;Esseling Norbert;Walke Bernhard H.
    • Journal of Communications and Networks
    • /
    • v.7 no.2
    • /
    • pp.104-114
    • /
    • 2005
  • This work presents a concept and the related analysis of the traffic performance for a wireless broadband system based on fixed relay stations acting as wireless bridges. The analysis focuses on the important performance indicators end-to-end throughput and delay, taking into account the effects of an automated repeat request protocol. An extension to a MAC frame based access protocol like IEEE 802.11e, 802.15.3, 802.16a, and HIPERLAN2 is outlined and taken as basis for the calculations. The system is intended for both dense populated areas as an overlay to cellular radio systems and to provide wide-area broad-band coverage. The two possible deployment scenarios for both dense urban and wide-area environments are introduced. Analytical and validating simulation results are shown, proving the suitability of the proposed concept for both of the mentioned scenarios. It is established that the fixed relaying concept is well suited to substantially contribute to provide high capacity cellular broad-band radio coverage in next generation (NG) cellular wireless broadband systems.

Experimental and analytical investigation on seismic behavior of RC framed structure by pushover method

  • Sharma, Akanshu;Reddy, G.R.;Eligehausen, R.;Vaze, K.K.
    • Structural Engineering and Mechanics
    • /
    • v.39 no.1
    • /
    • pp.125-145
    • /
    • 2011
  • Pushover analysis has gained significant popularity as an analytical tool for realistic determination of the inelastic behaviour of RC structures. Though significant work has been done to evaluate the demands realistically, the evaluation of capacity and realistic failure modes has taken a back seat. In order to throw light on the inelastic behaviour and capacity evaluation for the RC framed structures, a 3D Reinforced concrete frame structure was tested under monotonically increasing lateral pushover loads, in a parabolic pattern, till failure. The structure consisted of three storeys and had 2 bays along the two orthogonal directions. The structure was gradually pushed in small increments of load and the corresponding displacements were monitored continuously, leading to a pushover curve for the structure as a result of the test along with other relevant information such as strains on reinforcement bars at critical locations, failure modes etc. The major failure modes were observed as flexural failure of beams and columns, torsional failure of transverse beams and joint shear failure. The analysis of the structure was by considering all these failure modes. In order to have a comparison, the analysis was performed as three different cases. In one case, only the flexural hinges were modelled for critical locations in beams and columns; in second the torsional hinges for transverse beams were included in the analysis and in the third case, joint shear hinges were also included in the analysis. It is shown that modelling and capturing all the failure modes is practically possible and such an analysis can provide the realistic insight into the behaviour of the structure.

The study on construction of the practical testing ground of grid-connected photovoltaic system (태양광발전 계통연계 실증시험장 구축에 관한 연구)

  • Kim, Euihwan;Jang, Juyeon
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.65.2-65.2
    • /
    • 2010
  • Currently the variety of governmental business support and research for supplying solar energy have been actively progressed. As of now, however, There are no practical testing infrastructures of grid-connected photovoltaic system which test performance of solar power facility in domestic. Therefore, in KEPRI, there is in progress construction of practical testing ground of 500 kW class grid-connected PV System for developing the evaluation of the performance technology including the Module, PCS, and etc, that is the important instrument of the PV System, in Gochang area. It analyzed the site creation work for constructing the practical testing ground and new construction of control room and the unit standards, specifications and capacity of required equipment. For the system detailed design, configuration, instrument-specific parameters established, power generation predictions of Array Type and the components of testing ground are needed to build.

  • PDF

PLC Filter Capacity Improvement and Efficiency Evaluation of Smart Street Lighting System (스마트 가로등 시스템의 전력선통신 필터 성능 개선 및 효율 평가)

  • Kim, Myung-Ho
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.2
    • /
    • pp.154-157
    • /
    • 2009
  • In order to give handiness to the management of the existing street lighting system which is based on the one way communication and to reduce the maintenance cost, the power line communication filter in the two way communication which is based on the CDMA communication and power line communication was improved and accordingly the stability of the communication performance was improved. Also, the efficiency of existing street lighting system and smart street lighting system was evaluated as Visual studio system. As a result, when the number of street lights is 10,000, the hours of daily work fell 50% and the number of necessary maintenance staff decreased 40%. Compared to the maintenance costs of the existing street lighting system, it could be expected to have the cut costs of almost 100 million won a year on the basis of 60 switch board and 1,200 street lights.