• Title/Summary/Keyword: Wooden House Standard Model

Search Result 4, Processing Time 0.021 seconds

Hygrothermal Performance Improvement Plan of Standard Model for Rural Housing and Wooden Housing (농촌주택 및 목조주택 표준모델 구조체의 습·열 환경 성능 개선 방안)

  • Yoo, Dong-Wan;Lee, Tae-Goo
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.23 no.4
    • /
    • pp.63-71
    • /
    • 2021
  • The purpose of this study was to investigate whether the standard models for rural housing and wooden housing model have performance for hygrothermal and to propose a way of improvement relevant to hygrothermal performance for those models. All of the models to be analyzed were found to have some parts that were absent of stability in terms of performance for hygrothermal. In the process of analyzing the causes and proposing improvement measures, the following conclusions were derived. Fist, The exterior surface of the structure should be composed of a structure with good moisture permeability, and for the interior surface, a variable vapor retarder paper should be applied in consideration of the reverse condensation phenomenon in summer. Second, in terms of performance for hygrothermal, applications of external insulation plaster finish to the exterior wall or of ventilation method using a rafter vent on the roof should be avoided. Third, a rain screen method with a ventilation layer should be applied to the exterior wall, and a method of constructing ventilation layer separated from the insulation layer with a vapor retarder paper should be applied to the roof. Fourth, the application of insulation materials having capillary action, such as wood fiber insulation board or cellulose insulation board, contributes to more stable performance for hygrothermal.

A study on the Plan Modular Establishment for the Development of Wooden Dwelling Model - Focused on the Post & Beam Structure - (목조주택 모형개발을 위한 평면모듈 설정에 대한 연구 - 기둥-보 방식 구조를 중심으로 -)

  • Kang, Man-Ho;Joo, Seok-Joong;Kim, Jae-Deok
    • Journal of the Korean housing association
    • /
    • v.18 no.1
    • /
    • pp.141-148
    • /
    • 2007
  • In this research, to develope wooden house model with post & beam structure which is commensurate with domestic environment, we analyzed the size and module of a unit space and space organization of existing habitation, then, based on the result, we tried to suggest general wood house modules. For this, we investigated 98 floor plans for 30 pyeong apartment in Seoul, Gyounggi-do, Gwangju, and Jeolla-do. The results are showed as follows. 1) It has shown that 7 posts distances are available in 2 bay floor plan type - 3.0 m, 3.3 m, 3.6 m, 3.9 m, 4.2 m, 4.5 m, and 4.8 m. 2) It has shown that 8 posts distances are available in 3 bay floor plan type - 3.0 m, 3.3 m, 3.6 m, 3.9 m, 4.2 m, 4.5 m, 4.8 m, and 5.1 m. It was concluded as follows, applying the standard of regulations of horizontal modular coordination design, from $\ulcorner$the standard of modular coordination design in architecture(KSF 1525)$\lrcorner$. 1) The available widths are 3.0 m, 3.3 m, 3.6 m, 4.2 m, and 4.8 m, and the available depths are 3.0 m, 3.3 m, 3.6 m, and 4.2 m. 2) To guarantee a space through post module of a room combination, we can use a module of 3.6 m, 4.2 m, 4.8 m except 3.0 m, 3.3 m among available modules. The module investigated in post & beam structure wooden house is applied in basic 6 floor plans as follows. 1) When organize the room on the basis of tile module of 3.6 m, 4.2 m, it was possible to organize the floor plan. 2) After arranging main room, making practical application of variableness which is advantage of post & beam structure, putting to practical use of extra space that becomes the combination of atypical room such as kitchen, dining room, and bathroom, it was possible to organize the floor plan of the residence. 3) It is possible to organize whole rooms through the plan module from 3.6 m to 4.2 m, that decides the floor plan of a wooden house.

Fire Resistance Performance and Thermal Performance Evaluation of Structural Insulated Panels for Low-Energy Houses (구조단열패널의 저에너지주택 적용을 위한 내화 및 단열성능 평가)

  • Lee, Hyeon-Ju;Nah, Hwan-Seon;Lee, Cheol-Hee;Choi, Sung-Mo
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.3 no.2
    • /
    • pp.36-46
    • /
    • 2012
  • Structure Insulated Panel (SIP) is an wooden structure material with which structure and insulation functions are satisfied. Hence, it would be a cost-effective model to implement low energy house which has higher insulation and structure performance and which the wall thickness is able to be reduced. In this study, performance of thermal insulation and fire resistance were evaluated in order to verify applicability to low energy house. Fire resistance test is performed on vertical load bearing members for partitions, and the test results satisfy one hour of fire resistance condition according to KS F 2257. The members include two layers of fireproof gypsum board with thicknesses of 12.5mm attached to SIP. Thermal insulation performance is satisfied with the 2012 standard ($0.225W/m^2{\cdot}K$). As the performance of resistance and thermal insulation are satisfied, SIP is expected to be applied to low energy building materials. In the future, the structural safety will be confirmed by structural performance and seismic performance test and the guidelines for distribution will be drawn up.

Evaluation and Analysis of The Building Energy Saving Performance by Component of Wood Products Using EnergyPlus (EnergyPlus를 이용한 건물 부위별 목질제품 적용에 따른 건축물 에너지 절감 기여도 평가)

  • Seo, Jungki;Wi, Seunghwan;Kim, Sumin
    • Journal of the Korean Wood Science and Technology
    • /
    • v.44 no.5
    • /
    • pp.655-663
    • /
    • 2016
  • Increasing green house gas and it consequent climate change problems are discussed as a global issue. Accordingly, future local green house gas emission will increase up to 40% of the entire local green house gas emission and therefore, efforts to reduce the emission in construction industry is urgently required. Therefore, in this study, heating energy demand was analyzed by using the EnergyPlus simulation according to wood material finishes configuration. EnergyPlus has the entry for a variety of buildings and heating, ventilation, air conditioning (HAVC) system components, in particular buildings, air conditioning systems, and performs simultaneous integrated calculated through the feedback between the heat source unit, a verification program according to the ASHRAE Standard 140-2007 to be. The climate data for the simulation we used the data IWEC in Incheon and Gwangju provided by EnergyPlus. The analysis of simulation model was farm and fishing house standard design drawings: 2012, presented at the Korea Rural Community Corporation. The results of simulation of central region and southern region were effected by wood products of simulation model into the interior finish, exterior finish, windows, wooden structure. Also, it was confirmed that the reduced heating energy demand.