• Title/Summary/Keyword: Without transformer

Search Result 219, Processing Time 0.033 seconds

A Quadrature VCO Exploiting Direct Back-Gate Second Harmonic Coupling

  • Oh, Nam-Jin
    • Journal of electromagnetic engineering and science
    • /
    • v.8 no.3
    • /
    • pp.134-137
    • /
    • 2008
  • This paper proposes a novel quadrature VCO(QVCO) based on direct back-gate second harmonic coupling. The QVCO directly couples the current sources of the conventional LC VCOs through the back-gate instead of front-gate to generate quadrature signals. By the second harmonic injection locking, the two LC VCOs can generate quadrature signals without using on-chip transformer, or stability problem that is inherent in the direct front-gate second harmonic coupling. The proposed QVCO is implemented in $0.18{\mu}m$ CMOS technology operating at 2 GHz with 5.0 mA core current consumption from 1.8 V power supply. The measured phase noise of the proposed QVCO is - 63 dBc/Hz at 10 kHz offset, -95 dBc/Hz at 100 kHz offset, and -116 dBc/Hz at 1 MHz offset from the 2 GHz output frequency, respectively. The calculated figure of merit(FOM) is about -174 dBc/Hz at 1 MHz offset. The measured image band rejection is 46 dB which corresponds to the phase error of $0.6^{\circ}$.

Voltage Control and Security Assessment of Power System Using Mixed Integer Linear Programming (혼합정수 선형계획법을 이용한 계통의 전압제어 및 안전도 평가)

  • 김두현;김상철
    • Journal of the Korean Society of Safety
    • /
    • v.14 no.2
    • /
    • pp.70-76
    • /
    • 1999
  • In this paper, a mixed-integer programming approach is presented for adjusting the voltage profiles in a power system. The advent of large-scaled system makes the reactive power and voltage problem-an attempt to achieve an overall improvement of system security, service quality and economy-more complex and seriously, Although the problem is originally a nonlinear optimization problem, it can be formulated as a mixed integer linear programming(MILP) problem without deteriorating of solution accuracy to a certain extent. The MILP code is developed by the branch and bound process search for the optimal solution. The variable for modeling transformer tap positions is handled as discrete one, and other variables continuous ones. Numerical data resulting from case study using a modified IEEE 30 bus system with outaged line show that the MILP can produce more reductions of magnitude in the operating cost. The convergence characteristics of the results are also presented and discussed.

  • PDF

A Gate Drive IC for Power Modules with Shoot-through Immunity (상단락 방지용 모듈을 구동하기 위한 게이트 구동 IC)

  • Seo, Dae-Won;Kim, Jun-Sik;Park, Shi-Hong
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.22 no.7
    • /
    • pp.580-583
    • /
    • 2009
  • This paper introduces a gate drive IC for power modules with shoot-through immunity. A new approach uses a bootstrap diode as a high-side voltage bias and a level shift function at the same time. Therefore, the gate drive circuit becomes a simple and low-cost without conventional level shift functions such as HVIC(High-Voltage IC), optocoupler and transformer. The proposed gate drive IC is designed and fabricated using the Dongbu-Hitek's 0.35um BD350BA process. It has been tested and verified with IGBT modules.

A Inverter Design of Reversible Power Converter (가역 전력변환기의 인버터 설계)

  • Chun, J.H.;Lee, H.W.;Baek, S.H.;Kwak, D.K.
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.8-13
    • /
    • 2005
  • In this paper discusses single-phase DC-AC Inverter design of reversible power converter that driven by binary combination at different transformer winding ratio by BCD code level. It has a advantage that constructs a control system simply and obtain load current of good quality without filter circuit and free from noise or isolation for lower switching frequency. In this research, study on current type converter and inverter circuit that consist for possibility of AC-DC/DC-AC multi-level reversible converter.

  • PDF

Stand-Alone Wind Energy Conversion System with an Asynchronous Generator

  • Singh, Bhim;Sharma, Shailendra
    • Journal of Power Electronics
    • /
    • v.10 no.5
    • /
    • pp.538-547
    • /
    • 2010
  • This paper deals with a stand-alone wind energy conversion system (WECS) with an isolated asynchronous generator (IAG) and voltage and frequency (VF) control feeding three-phase four-wire loads. The reference generator currents are estimated using the instantaneous symmetrical component theory to control the voltage and frequency of an IAG system. A three-leg voltage source converter (VSC) with an isolated star/delta transformer is used as an integrated VSC. An integrated VSC with a battery energy storage system (BESS) is used to control the active and reactive powers of the WECS. The WECS is modeled and simulated in MATLAB using the Simulink and the Sim Power System (SPS) toolboxes. The proposed VF controller functions as a voltage and frequency regulator, a load leveler, a load balancer and a harmonic eliminator in the WECS. A comparison is made on the rating of the VSC with and without ac capacitors connected at the terminals of an IAG. Simulation and test results are presented to verify the control algorithm.

Analysis and Design of a Soft-Switched PWM Sepic DC-DC Converter

  • Kim, In-Dong;Kim, Jin-Young;Nho, Eui-Cheol;Kim, Heung-Geun
    • Journal of Power Electronics
    • /
    • v.10 no.5
    • /
    • pp.461-467
    • /
    • 2010
  • This paper proposes a new soft-switched Sepic converter. It has low switching losses and low conduction losses due to its auxiliary communicated circuit and synchronous rectifier operation, respectively. Because of its positive and buck/boost-like DC voltage transfer function (M=D/(1-D)), the proposed converter is desirable for use in distributed power systems. The proposed converter has versions both with and without a transformer. The paper also suggests some design guidelines in terms of the power circuit and the control loop for the proposed converter.

Bridgeless Flyback PFC Rectifier Using Single Magnetic Core and Dual Output Windings

  • Shin, Jong-Won;Baek, Jong-Bok;Cho, Bo-Hyung
    • Proceedings of the KIPE Conference
    • /
    • 2011.07a
    • /
    • pp.145-146
    • /
    • 2011
  • In this paper, a bridgeless flyback power factor correction (PFC) rectifier which uses single magnetic core is proposed. The proposed PFC rectifiers utilize bidirectional switch to handle both positive and negative input voltage without bridge diodes. A transformer with dual output windings enables the rectifier dispense with any additional magnetic component. The operation of the proposed flyback PFC rectifier is analyzed, and its higher efficiency than its conventional counterpart is verified by experiment.

  • PDF

Traceable AC Voltage and Current Measurements Using Digital Sampling Technique (디지털 샘플링 방법을 사용한 교류전압과 전류의)

  • Wijesinghe, W.M.S.;Park, Young-Tae
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.686_687
    • /
    • 2009
  • The traceability maintenance system for the AC voltage and current has been developed at the frequency range of 20 Hz to 100 Hz without using any compensation technique which is used at thermal converter (TC) ac-dc transfer system at low frequencies. The system uses a digital voltmeter (DVM) as a data acquisition system of the input waveform and stored data in memory. The developed algorithm acquires and processes the sampling data to calculate the root mean square (rms) value of the input voltage of DVM which operates at DC 10 V range for better accuracy. The best uncertainty of the AC voltage measurements is $3 {\mu}V/V$ within the frequency range. The best uncertainty of the AC current measurements is better than the $5 {\mu}A/A$ and mainly depend on the current to voltage converter, ac-dc current shunt or Current Transformer (CT), used for the measurement

  • PDF

High Voltage Pulse Generator Using Power Semiconductor Switcher (전력용 반도체 소자를 이용한 새로운 고전압 펄스발생회로)

  • Baek, Ju-Won;Kim, Heung-Geun
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.50 no.8
    • /
    • pp.408-415
    • /
    • 2001
  • Using power semiconductor switches such as IGBTs, diodes and L-C circuits, novel repetitive impulse voltage generator is developed. In the presented circuits, high voltage pulse is generated by series-connection of capacitors and IGBTs. Therefore, the high voltage pulse is obtained by circuit configuration without any high voltage pulse transformer and high voltage dc source. Especially, the proposed circuit can operate up to several kHz and have high reliability and longer life than conventional ones. In also gives voltage balance of IBGTs automatically. So, the difference of characteristics of IGBTs and drive signal does not cause severe problems. To verify the proposed circuit, 20kV and 300A pulse generator is manufactured and tested.

  • PDF

A Study on Performance of Current Transformer in High Voltage System (고압계통 변류기 동작 특성 검토)

  • Choi, Ki-Yeol;Lee, Duck-Soo;Park, Moon-Bin;Kim, Hee-Taek;Chang, Ki-Poong
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.5-7
    • /
    • 2006
  • Current transformers(CTs) whose rating is selected per a full load current of a feeder in high voltage system can be easily saturated due to high fault current that may be several hundred times of the full load current of the feeder. However, the protective relay shall operate properly at the fault without mis-operation under the CT saturation. So, in selecting the CT rating, it is necessary to consider the behaviour of CT and a performance of protection scheme in condition where CT can be saturated. In this paper, a performance of CT and a degree of saturation are studied and verified whether its ratings are proper for the operation of the protective relay.

  • PDF