• Title/Summary/Keyword: Wireless capsule endoscopy

Search Result 11, Processing Time 0.019 seconds

Capsule Endoscopy in Children (소아에서의 캡슐내시경)

  • Ko, Jae-Sung
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.13 no.1
    • /
    • pp.1-6
    • /
    • 2010
  • The small bowel is the most difficult intestinal segment to examine. Radiologic tests are mostly insensitive and double-balloon enteroscopy is unsuitable for the younger child. Capsule endoscopy is a novel wireless method of investigation of the small bowel. The primary indications for capsule endoscopy include evaluation of obscure gastrointestinal bleeding, small bowel Crohn's disease, and polyposis syndromes. Capsule endoscopy offers an accurate and effective means of investigating the small bowel in children. Capsule retention is a potential complication of capsule endoscopy. This review provides the indications, safety, and limitations of wireless capsule endoscopy in children.

Integrated Power Optimization with Battery Friendly Algorithm in Wireless Capsule Endoscopy

  • Mehmood, Tariq;Naeem, Nadeem;Parveen, Sajida
    • International Journal of Computer Science & Network Security
    • /
    • v.21 no.11
    • /
    • pp.338-344
    • /
    • 2021
  • The recently continuous enhancement and development in the biomedical side for the betterment of human life. The Wireless Body Area Networks is a significant tool for the current researcher to design and transfer data with greater data rates among the sensors and sensor nodes for biomedical applications. The core area for research in WBANs is power efficiency, battery-driven devices for health and medical, the Charging limitation is a major and serious problem for the WBANs.this research work is proposed to find out the optimal solution for battery-friendly technology. In this research we have addressed the solution to increasing the battery lifetime with variable data transmission rates from medical equipment as Wireless Endoscopy Capsules, this device will analyze a patient's inner body gastrointestinal tract by capturing images and visualization at the workstation. The second major issue is that the Wireless Endoscopy Capsule based systems are currently not used for clinical applications due to their low data rate as well as low resolution and limited battery lifetime, in case of these devices are more enhanced in these cases it will be the best solution for the medical applications. The main objective of this research is to power optimization by reducing the power consumption of the battery in the Wireless Endoscopy Capsule to make it battery-friendly. To overcome the problem we have proposed the algorithm for "Battery Friendly Algorithm" and we have compared the different frame rates of buffer sizes for Transmissions. The proposed Battery Friendly Algorithm is to send the images on average frame rate instead of transmitting the images on maximum or minimum frame rates. The proposed algorithm extends the battery lifetime in comparison with the previous baseline proposed algorithm as well as increased the battery lifetime of the capsule.

Reducing Power Consumption of Wireless Capsule Endoscopy Utilizing Compressive Sensing Under Channel Constraint

  • Saputra, Oka Danil;Murti, Fahri Wisnu;Irfan, Mohammad;Putri, Nadea Nabilla;Shin, Soo Young
    • Journal of information and communication convergence engineering
    • /
    • v.16 no.2
    • /
    • pp.130-134
    • /
    • 2018
  • Wireless capsule endoscopy (WCE) is considered as recent technology for the detection cancer cells in the human digestive system. WCE sends the captured information from inside the body to a sensor on the skin surface through a wireless medium. In WCE, the design of low-power consumption devices is a challenging topic. In the Shannon-Nyquist sampling theorem, the number of samples should be at least twice the highest transmission frequency to reconstruct precise signals. The number of samples is proportional to the power consumption in wireless communication. This paper proposes compressive sensing as a method to reduce power consumption in WCE, by means of a trade-off between samples and reconstruction accuracy. The proposed scheme is validated under channel constraints, expressed as the realistic human body path loss. The results show that the proposed scheme achieves a significant reduction in WCE power consumption and achieves a faster computation time with low signal error reconstruction.

Wireless capsule endoscopy Locomotion

  • Wang, Zhao;Lim, Eng Gee;Leach, Mark;Xia, Tianqi;Lee, Sanghyuk
    • Journal of Convergence Society for SMB
    • /
    • v.4 no.1
    • /
    • pp.55-62
    • /
    • 2014
  • Wireless capsule endoscopy (WCE) was one of the most influential bio-medical electronic technologies to be developed at the beginning of the century. In comparison to traditional endoscopic diagnosis, this application is characterized as non-invasive and low-risk, thereby providing surgeons with a new alternative for inspecting the entire gastrointestinal (GI) track in a much more user friendly way. Apart from regular hardware upgrades, the frontier of WCE research basically lies in the miniaturization of the capsule and in active locomotion. In order to overcome the intrinsic drawback of current commercialized WCE products, which is that locomotion is generally a function of natural peristalsis, active locomotion is proposed as a series of strategies used to effectively navigate the device into different organs and conduct therapeutic functions within targeted human tissues. Reviews of several novel designs with respect to this aspect of research will be discussed in this article.

  • PDF

Enhanced Common-Mode Noise Rejection Method Based on Impedance Mismatching Compensation for Wireless Capsule Endoscopy Systems

  • Hwang, Won-Jun;Kim, Ki-Yun;Choi, Hyung-Jin
    • ETRI Journal
    • /
    • v.37 no.3
    • /
    • pp.637-645
    • /
    • 2015
  • Common-mode noise (CMN) is an unresolved problem in wireless capsule endoscopy (WCE) systems. In a WCE system, CMN originates from various electric currents found within the human body or external interference sources and causes critical demodulation performance degradation. The differential operation, a typical method for the removal of CMN rejection, can remove CMN by subtracting two signals simultaneously received by two reception sensors attached to a human body. However, when there is impedance mismatching between the two reception sensors, the differential operation method cannot completely remove CMN. Therefore, to overcome this problem, we propose an enhanced CMN rejection method. The proposed method performs not only subtraction but also addition between two received signals. Then a CMN ratio can be estimated by sufficient accumulation of division operation outcomes between the subtraction and addition outputs during the guard period. Finally, we can reject the residual CMN by combining the subtraction and addition outputs.

Development of Head Mounted Display Interface System for Controlling Wireless Capsule Endoscope (무선 캡슐내시경 조종을 위한 머리부착형 디스플레이 인터페이스 시스템의 개발)

  • Young-Eun, Hwang;Young-Don, Son
    • Journal of Biomedical Engineering Research
    • /
    • v.43 no.6
    • /
    • pp.417-423
    • /
    • 2022
  • The present study proposed a new interface system for capsule endoscopy by using head mounted display (HMD) device, which can control the orientation of the capsule endoscope with electromagnetic actuator (EMA) system. The orientation information of the HMD user was detected by the gyroscope sensor built into the device and then calculated to as an angle increment using Unity Engine compiler. The measured angle changes from the HMD were converted to the current values of the corresponding coils to be changed in the EMA system. Two experiments were designed to measure the accuracy and the intuitiveness of the HMD interface system. In the angle accuracy measurement, the capsule endoscope driven by HMD interface system showed the averaged errors of 0.68 degrees horizontally and 1.001 degrees vertically for given test angles. In the intuitiveness measurement, HMD interface system showed 1.33 times faster manipulation speed rather than the joystick interface system. In this respect, the HMD interface system for capsule endoscopy was expected to improve the overall diagnostic environment while maintaining comfort of patients and clinicians.

Dynamic Behavior Analysis of Tiny Robot

  • Wang, Zhao;Lim, Eng Gee
    • Journal of Convergence Society for SMB
    • /
    • v.4 no.1
    • /
    • pp.17-29
    • /
    • 2014
  • The wireless capsule endoscopy played an important role as the evolutionary medical device to solving the difficulties such as diagnosing the intestine diseases. Due to the limited size and functions, it has some drawbacks. The most obstacle thing is the disability of self-motion, it means that it cannot provide the speed problem. Hence, the characteristics of human digestion system is briefly introduced, especially the intestine, to get the information of endoscopy dynamics. Next, in order to make an abstraction of the condition, a new dynamic friction model called LuGre model is introduced and clearly analysed to get the characteristics and the usage of the model. By the consideration of parameters that are tightly related with the real situation of the capsule endoscopy. The Matlab Simulink was applied to build the model and verified by the simulation to discover the features.

  • PDF

Design of Miniaturized Telemetry Module for Bi-Directional Wireless Endoscopy

  • Park, H. J.;H. W. Nam;B. S. Song;J. H. Cho
    • Proceedings of the IEEK Conference
    • /
    • 2002.07a
    • /
    • pp.494-496
    • /
    • 2002
  • A bi-directional and multi-channel wireless telemetry capsule, 11mm in diameter, is presented that can transmit video images from inside the human body and receive a control signal from an external control unit. The proposed telemetry capsule includes transmitting and receiving antennas, a demodulator, decoder, four LEDs, and CMOS image sensor, along with their driving circuits. The receiver demodulates the received signal radiated from the external control unit. Next, the decoder receives the stream of control signals and interprets five of the binary digits as an address code. Thereafter, the remaining signal is interpreted as four bits of binary data. Consequently, the proposed telemetry module can demodulate external signals so as to control the behavior of the camera and four LEDs during the transmission of video images. The proposed telemetry capsule can simultaneously transmit a video signal and receive a control signal determining the behavior of the capsule itself. As a result, the total power consumption of the telemetry capsule can be reduced by turning off the camera power during dead time and separately controlling the LEDs for proper illumination of the intestine.

  • PDF

Design of UWB Antenna for the External Receiver of Capsule Endoscopy (캡슐 내시경의 외부 수신기용 UWB 안테나 설계)

  • Kim Hong-Seok;Oh Min-Seok;Cheon Chang-Yul
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.8 s.99
    • /
    • pp.790-796
    • /
    • 2005
  • In order to accomplish a wireless communication of capsule endoscopy, an environment study in the human body and receiving antenna design have been performed. The proposed antenna is the loop antenna designed to minimize the propagation loss in multi-loss layer such as the human body and utilize the magnetic field. Considering the propagation loss in the human body, the frequency range is from 400 MHz to 500 MHz. Acorrrding to the FCC regulations, the permittivity and conductivity for each human tissue were extracted. We set up an equivalent model and make an aqueous solution which is replaced with the human body. Due to movement of capsule in the human body which propagation loss is extremly severe, an array antenna is required. Irrespective of the location of transmission antenna transmitting a signal of 1 mW, we confirme what it is possible for the enough signal detection as the average signal level of array antenna is -60 dBm.

Design and fabrication of the Locomotive Mechanism for Capsule Endoscopes Using Shape Memory Alloys (SMA) (SMA를 이용한 캡슐 내시경의 이동메커니즘 설계 및 제작)

  • Lee, Seung-Hak;Kim, Byung-Kyu;Park, Jong-H.;Park, Jong-Oh
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.27 no.11
    • /
    • pp.1849-1855
    • /
    • 2003
  • Newly commercialized wireless capsule endoscope has many advantages compared to conventional push-type endoscopes. However, it is moved by the peristaltic waves. Therefore, it can not diagnose desired zones actively. In this paper, a locomotive mechanism for wireless capsule endoscope is proposed to increase the efficiency of endoscopy. We designed and fabricated a prototype using SMA springs and bio-mimetic clamping device. The hollow space in the prototype is allocated for further system integration of a camera module, a RF module and a battery. And the sequential control scheme is employed to improve the efficiency of its locomotion. To validate the performance of the locomotive mechanism, experiments on a silicone rubber pad and in vitro tests are carried out. The results of the experiments indicate that proposed mechanism is effective in harsh environments such as digestive organs of a human.