• Title/Summary/Keyword: Wireless X-ray

Search Result 21, Processing Time 0.022 seconds

Wireless Triggering Pulse Generation for Digital X-ray Imaging System (디지털 x-ray 영상시스템을 위한 무선 트리거 발생기)

  • Ko, Dae-Sik;Lee, Jae-Cheol;Lee, Joo-Shin
    • Journal of Advanced Navigation Technology
    • /
    • v.11 no.2
    • /
    • pp.163-169
    • /
    • 2007
  • In this paper, we propose a method of trigger pulse generation to capture the image on time by making a synchronization between the x-ray generator and digital x-ray image acquisition system. we designed a wireless trigger pulse generation circuit to make a synchronization between x-ray generator and digital image acquisition system and analysis its performance. When it starts to detect a certain level of x-ray radiation or above from the air, this method starts to generate a ACQ_START signal to indicate the timing for image acquisition starting from digital image acquisition system. Hence, when it starts to detect under certain level of x-ray signal from the air, this method starts to generate a ACC_END signal to indicate the timing for image acquisition stop from digital image acquisition system. Image acquisition is activated only this time between ACQ_START and ACQ_END signal. By doing this wireless detecting of x-ray signal from remote, we can get more accurate timing for capturing the x-ray image and any type of x-ray generator can be connected to digital image acquisition system, regards of wired protocol. This makes easy installation. We could get 3.5 line pair / mm resolution at 20 mAs of x-ray level with resolution chart. This is same or better image comparing to conventional wired result.

  • PDF

Development of a Small Animal CT using a Linear Detector Array and Small-Scale Slip Rings

  • An Ung Hwan;Chun In Kon;Lee Sang Chul;Cho Min Hyoung;Lee Soo Yeol
    • Journal of Biomedical Engineering Research
    • /
    • v.26 no.1
    • /
    • pp.43-47
    • /
    • 2005
  • We have developed a small bore x-ray CT for small animal imaging with a linear x-ray detector array and small-scale slip rings. The linear x-ray detector array consists of 1024 elements of 400□m×400□m with a gadolinium oxysulfide (GOS) scintillator on top of them. To avoid use of expensive large diameter slip rings for projection data transmission from the X­ray detector to the image reconstruction system, we used the wireless LAN technology. The projection data are temporally stored in the data acquisition system residing on the rotating gantry during the scan and they are transmitted to the image reconstruction system after the scan. With the wireless LAN technology, we only needed to use small-scale slip rings to deliver the AC electric power to the X-ray generator and the power supply on the rotating gantry. The performances of the small animal CT system, such as SNR, contrast, and spatial resolution, have been evaluated through experiments using various phantoms. It has been experimentally found that the SNR is almost linearly proportional to the tube current and tube voltage, and the minimum resolvable contrast is less than 30 CT numbers at 40kVp/3.0㎃. The spatial resolution of the small animal CT system has been found to be about 0.9Ip/㎜. Postmortem images of a piglet is also presented.

Terahertz Time Domain Spectroscopy, T-Ray Imaging and Wireless Data Transfer Technologies

  • Paek, Mun-Cheol;Kwak, Min-Hwan;Kang, Seung-Beom;Kim, Sung-Il;Ryu, Han-Cheol;Choi, Sang-Kuk;Jeong, Se-Young;Kang, Dae-Won;Jun, Dong-Suk;Kang, Kwang-Yong
    • Journal of electromagnetic engineering and science
    • /
    • v.10 no.3
    • /
    • pp.158-165
    • /
    • 2010
  • This study reviewed terahertz technologies of time domain spectroscopy, T-ray imaging, and high rate wireless data transfer. The main topics of the terahertz research area were investigation of materials and package modules for terahertz wave generation and detection, and setup of the terahertz system for time domain spectroscopy(TDS), T-ray imaging and sub-THz wireless communication. In addition to Poly-GaAs film as a photoconductive switching antenna material, a table-top scale for the THz-TDS/imaging system and terahertz continuous wave(CW) generation systems for sub-THz data transfer and narrow band T-ray imaging were designed. Dielectric properties of ferroelectric BSTO($Ba_xSr_{1-x}TiO_3$) films and chalcogenide glass systems were characterized with the THz-TDS system at the THz frequency range. Package modules for terahertz wave transmitter/receiver(Tx/Rx) photoconductive antenna were developed.

A research on remote X-ray detector design development for marketing in field diagnosis service (현장 진단 서비스 시장 공략을 위한 '무선 X-ray 디텍터' 디자인개발에 관한 연구)

  • Song, Seong Il
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.27 no.4
    • /
    • pp.196-205
    • /
    • 2017
  • In recent years, the service design in the medical sector evolves through practical service research and development that can visualize both intangible and intangible service elements in an integrative way and derive innovative solutions to help customers feel the service more important value. With the improvement of personal income, interest in medical welfare and well-being is increasing day by day, and the focus of the medical sector shifts from the concept of treatment of diseases and illness to preventive medicine. In response to this trend, research and development of home health care system, which greatly reduces the time and space constraint of health checkup and health care by combining ubiquitous concept with medical welfare, are being actively conducted, and the needs for improving products and medical environment based on user-centered medical service and user needs in accordance with the Health Care 3.0 Era, it becomes necessary to develop on-site medical diagnostic products that reflect user-centered needs and needs. This study is intended to research and develop a product that sufficiently reflects the needs of users by applying suitable materials and shape for on-site diagnostic product in researching and developing Wireless X-ray Detector.

Comparative Analysis of pre and Post Digital X-ray Equipment Construction and Web-Based Wireless Network Environment Construction for Medical Screening Vehicles (Digital X-ray장비 구축 검진차량의 웹 기반 무선 네트워크 환경 구축 전과 후의 비교분석)

  • Ryu, Young-Hwan;Kweon, Dae-Cheol;Goo, Eun-Hoe;Dong, Kyung-Rae;Choi, Sung-Hyun;Jang, Young-Ill
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.12 no.2
    • /
    • pp.103-111
    • /
    • 2010
  • A total of 200 hospital employees participated in this study from January 2009 to June 2010. For the survey, each participant was given necessary items for external health exams. Cronbach's alpha was calculated for the survey regarding wireless networks. There was a need for educating data processing workers in the medical field regarding fundamental information prior to wireless network construction. The reason is high scores would be collected, which would reflect knowledge regarding data processing used at hospitals and the differences between paper charts and electronic charts. However, low scores were obtained which reflected knowledge regarding the differences between wired and wireless networks and Mini-PACS. Time for each patient was shortened to a maximum of three minutes and minimum of one minute for treatment and transmitting medical images when comparing pre and post wireless network construction(p < 0.01). Scores from the pre and post construction survey increase 1.98, 1.65, and 1.43 points for activity in the health screening area, usage of space in the health screening vehicle, and patient information storage respectively(p < 0.05). The number of patients receiving external health screenings twelve times was 3,655 prior to construction of a wireless network system. However, the number increased to 4,265 after construction. The increasing percentage was 17% in total. Prior to construction, X-ray images were taken 527 times, but after construction of a wireless network, this number growed to 1,194 and it was 116% increase. The loss of patient's medical treatment charts was reduced from 19.8% to 18.7% after construction. We believe that educating medical workers on Mini-PACS and Mini-OCS Systems will not only increase their efficiency but also make patients receiving better treatment.

  • PDF

A study on the digital image transfer application mass chest X-ray system up-grade (간접촬영기의 디지털 영상 변환 장치 적용에 대한 연구)

  • Kim, Sun-Chil;Park, Jong-Sam;Lee, Jon-Il
    • Journal of radiological science and technology
    • /
    • v.26 no.3
    • /
    • pp.13-17
    • /
    • 2003
  • By converting movable indirect mass chest X-ray devices for vehicles into digital systems and upgrading it to share information with the hospital's medical image information system, excellencies have been confirmed as a result of installing and running this type of system and are listed hereinafter. 1. Upgrading analog systems, such as indirect mass chest X-ray devices dependent on printed film, to digital systems allows them to be run and managed much more efficiently, contributing to the increase in the stability and the efficiency of the system. 2. Unlike existing images, communication based on DICOM standards allow images to be compatible with the hospital's outer and inner network PACS systems, extending the scope of the radiation departments information system. 3. Assuming chest-exclusive indirect mass chest X-rays, a linked development of CAD (Computer Aided Diagnosis, Detector) becomes possible. 4. By applying wireless Internet, Web-PACS for movable indirect mass chest X-ray devices for vehicles will become possible. Research in these fields must continue and if the superior image quality and convenience of digital systems are confirmed, I believe that the conversion of systems still dependent on analog images to modernized digital systems is a must.

  • PDF

Development of DAP(Dose Area Product) for Radiation Evaluation of Medical and Industrial X-ray generator (의료 및 산업용 X-선 발생장치의 선량평가를 위한 면적선량계(DAP) 개발)

  • Kwak, Dong-Hoon;Lee, Sang-Heon;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.22 no.2
    • /
    • pp.495-498
    • /
    • 2018
  • In this paper, we propose an DAP system for dose evaluation of medical and industrial X-ray generator. Based on the DAP measurement technique using the Ion-Chamber, the proposed system can clearly measure the exposure radiation dose generated by the diagnostic X-ray apparatus. The hardware part of the DAP measures the amount of charge in the air that is captured by an X-ray. The high-speed processing algorithm part for cumulative radiation dose measurement through microcurrent measures the amount of charge captured by X-ray at a low implementation cost (power) with no input loss. The wired/wireless transmission/reception protocol part synchronized with the operation of the X-ray generator improves communication speed. The PC-based control program part for interlocking and aging measures the amount of X-ray generated in real time and enables measurement graphs and numerical value monitoring through PC GUI. As a result of evaluating the performance of the proposed system in an accredited testing laboratory, the measured values using DAP increased linearly in each energy band (30, 60, 100, 150 kV). In addition, since the standard deviation of the measured value at the point of 4 division was ${\pm}1.25%$, it was confirmed that the DAP showed uniform measurements regardless of location. It was confirmed that the normal operation was not less than ${\pm}4.2%$ of the international standard.

Analysis of V2V Broadcast Performance Limit for WAVE Communication Systems Using Two-Ray Path Loss Model

  • Song, Yoo-Seung;Choi, Hyun-Kyun
    • ETRI Journal
    • /
    • v.39 no.2
    • /
    • pp.213-221
    • /
    • 2017
  • The advent of wireless access in vehicular environments (WAVE) technology has improved the intelligence of transportation systems and enabled generic traffic problems to be solved automatically. Based on the IEEE 802.11p standard for vehicle-to-anything (V2X) communications, WAVE provides wireless links with latencies less than 100 ms to vehicles operating at speeds up to 200 km/h. To date, most research has been based on field test results. In contrast, this paper presents a numerical analysis of the V2X broadcast throughput limit using a path loss model. First, the maximum throughput and minimum delay limit were obtained from the MAC frame format of IEEE 802.11p. Second, the packet error probability was derived for additive white Gaussian noise and fading channel conditions. Finally, the maximum throughput limit of the system was derived from the packet error rate using a two-ray path loss model for a typical highway topology. The throughput was analyzed for each data rate, which allowed the performance at the different data rates to be compared. The analysis method can be easily applied to different topologies by substituting an appropriate target path loss model.

A NEAR REAL-TIME FLARE ALERTING SYSTEM BASED ON GOES SOFT X-RAY FLUX

  • MOON Y.-J.;PARK Y. D.;SEONG H.-C.;LEE C.-W.;SIM K. J.;YUN H. S.
    • Journal of The Korean Astronomical Society
    • /
    • v.33 no.2
    • /
    • pp.123-126
    • /
    • 2000
  • We have developed a near real-time flare alerting system which (1) downloads the latest GOES-l0 1-8 ${\AA}$ X-ray flux 1-min data by an automated ftp program and shell scripts, (2) produces a beep sound in a simple IDL widget program when the flux is larger than a critical value, and (3) makes it possible to do a wireless alerting by a set of portable transceivers. Thanks to the system, we have made successful Ha flare observations by the Solar Flare Telescope in Bohyunsan Optical Astronomy Observatory. This system is expected to be helpful for ground-based flare observers.

  • PDF