• Title/Summary/Keyword: Wireless Telemetry System

Search Result 53, Processing Time 0.024 seconds

Comparison of Novel Telemonitoring System Using the Single-lead Electrocardiogram Patch With Conventional Telemetry System

  • Soonil Kwon;Eue-Keun Choi;So-Ryoung Lee;Seil Oh;Hee-Seok Song;Young-Shin Lee;Sang-Jin Han;Hong Euy Lim
    • Korean Circulation Journal
    • /
    • v.54 no.3
    • /
    • pp.140-153
    • /
    • 2024
  • Background and Objectives: Although a single-lead electrocardiogram (ECG) patch may provide advantages for detecting arrhythmias in outpatient settings owing to user convenience, its comparative effectiveness for real-time telemonitoring in inpatient settings remains unclear. We aimed to compare a novel telemonitoring system using a single-lead ECG patch with a conventional telemonitoring system in an inpatient setting. Methods: This was a single-center, prospective cohort study. Patients admitted to the cardiology unit for arrhythmia treatment who required a wireless ECG telemonitoring system were enrolled. A single-lead ECG patch and conventional telemetry were applied simultaneously in hospitalized patients for over 24 hours for real-time telemonitoring. The basic ECG parameters, arrhythmia episodes, and signal loss or noise were compared between the 2 systems. Results: Eighty participants (mean age 62±10 years, 76.3% male) were enrolled. The three most common indications for ECG telemonitoring were atrial fibrillation (66.3%), sick sinus syndrome (12.5%), and atrioventricular block (10.0%). The intra-class correlation coefficients for detecting the number of total beats, atrial and ventricular premature complexes, maximal, average, and minimal heart rates, and pauses were all over 0.9 with p values for reliability <0.001. Compared to a conventional system, a novel system demonstrated significantly lower signal noise (median 0.3% [0.1-1.6%] vs. 2.4% [1.4-3.7%], p<0.001) and fewer episodes of signal loss (median 22 [2-53] vs. 64 [22-112] episodes, p=0.002). Conclusions: The novel telemonitoring system using a single-lead ECG patch offers performance comparable to that of a conventional system while significantly reducing signal loss and noise.

REAL-TIME MONITORING TECHNOLOGY OF RAILWAY ELECTRIFICATION SYSTEM (철도시스템 전기설비의 실시간 모니터링 기술)

  • Park, Young;Jung, Ho-Sung;Kim, Hyung-Chul;Jeong, Kyu-Won;Park, Ki-Yub
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.476-477
    • /
    • 2007
  • The development of real-time monitoring technology provides reliable, timely information of railway maintenance and play a important role in determining the conditions of railway electrification system. Image motoring and wireless communication systems are currently used as remote transducer for real-time monitering. In this paper, we describe a real-time monitoring technology of railway electrification system based on the concept of high-voltage application, using the image processing and telemetry system methodology. the system and its performance for especially with regard to real-time monitering and railway electrification maintenance.

  • PDF

A FSK Radio-telemetry System for Monitoring Vital Signs in UHF Band (UHF 대역 FSK에 의한 생체신호 무선 전송장치의 개발)

  • Park D.C.;Lee H.K.
    • Journal of Biomedical Engineering Research
    • /
    • v.21 no.3 s.61
    • /
    • pp.255-260
    • /
    • 2000
  • This paper presents a radio-telemetry patient monitor. which is used for intensive cal?e units. emergency and surgical operation rooms to monitor continuously patients' vital signs. The radio-telemetry patient monitor consists of a vital sign acquisition unit. wireless data transmission units and a vital sign-monitoring unit. The vital sign acquisition unit amplifies biological signals, performs analog signal to serial digital data conversion using the one chip micro-controller. The converted digital data is modulated FSK in UHF band using low output power and transmitted to a remote site in door. In comparison with analog modulation. FSK has major advantages to improve performance with respect to noise resistance with fower error and the potential ability to process and Improve quality of the received data. The vital sign-monitoring unit consists of the receiver to demodulate the modulated digital data, the LCD monitor to display vital signs continuously and the thermal head printer to record a signal.

  • PDF

Development of a Composite Rotor for Flywheel Energy Storage System (플라이휠 에너지 저장 장치용 복합재 로터 개발)

  • Kim, Myung-Hun;Han, Hun-Hee;Kim, Jae-Hyuk;Kim, Seong-Jong;Ha, Seong-Gyu
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2005.11a
    • /
    • pp.169-172
    • /
    • 2005
  • A flywheel system is an electromechanical energy storage device that stores energy by rotating a rotor. The rotating part, supported by magnetic bearings, consists of the metallic shaft, composite rims of fiber-reinforced materials, and a hub that connects the rotor to the shaft. The delamination in the fiber wound composite rotor often lowered the performance of the flywheel energy storage system. In this work, an advanced hybrid composite rotor with a split hub was designed to both overcome the delamination problem in composite rim and prevent separation between composite rim and metallic shaft within all range of rotational speed. It was analyzed using a three-dimensional finite clement method. In order to demonstrate the predominant perfom1ance of the hybrid composite rotor with a split hub, a high spin test was performed up to 40,000 rpm. Four radial strains and another four circumferential strains were measured using a wireless telemetry system. These measured strains were in excellent agreement with the FE analysis. Most importantly, the radial strains were reduced using the hybrid composite rotor with a split hub, and all of them were compressive. As a conclusion, a compressive pressure on the inner surface of the proposed flywheel rotor was achieved, and it can lower the radial stresses within the composite rotor, enhancing the performance of the flywheel rotor.

  • PDF

A Scalable Wireless Body Area Network for Bio-Telemetry

  • Saeed, Adnan;Faezipour, Miad;Nourani, Mehrdad;Banerjee, Subhash;Lee, Gil;Gupta, Gopal;Tamil, Lakshman
    • Journal of Information Processing Systems
    • /
    • v.5 no.2
    • /
    • pp.77-86
    • /
    • 2009
  • In this paper, we propose a framework for the real-time monitoring of wireless biosensors. This is a scalable platform that requires minimum human interaction during set-up and monitoring. Its main components include a biosensor, a smart gateway to automatically set up the body area network, a mechanism for delivering data to an Internet monitoring server, and automatic data collection, profiling and feature extraction from bio-potentials. Such a system could increase the quality of life and significantly lower healthcare costs for everyone in general, and for the elderly and those with disabilities in particular.

Analysis of TM/TC data protocol of Military Unmanned Aerial Vehicles (군용 무인항공기의 TM/TC 데이터 프로토콜 분석)

  • Hong, Su-woon;Kim, Young-kil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2017.05a
    • /
    • pp.391-393
    • /
    • 2017
  • Unmanned aerial vehicles(UAVs) operating in the military for various purposes are designed to transmit information collected according to the purpose to GCS(Ground Control System), and to transmit/receive the vehicle's operational control and status information using wireless communication(or datalink). Currently, the military UAV systems in operation in Korea use unique communication methods, protocols, and message structures for each system. In this paper, we analyze the TM/TC data protocol of two types of military UAV systems currently under development and propose a more efficient TM/TC message design scheme in wireless communication(or datalink) environment. And we will discuss issues to be considered for standardization of technology for ensuring interoperability with many UAVs or newly introduced UAV systems.

  • PDF

Spin Test of 5 kWh Composite Flywheel Rotor (5 kWh 복합재 플라이휠 로터의 회전 시험)

  • Han, Hoon-Hee;Ha, Sung-Kyu;Kim, Jae-Hyuk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.9
    • /
    • pp.3135-3140
    • /
    • 2010
  • A 5 kWh composite flywheel rotor was designed and manufactured, and its spin test was performed to monitor strain distribution and burst speed. Strain distribution in radial and circumferential directions of the rotor were measured using a wireless telemetry system based on bluetooth technology for real-time strain measurement. The strains was compared with pre-calculated design values to verify the initial rotor design. We noticed the rotor failed at 19,499 rpm in the spin test, 11 % lower than the predicted burst speed of 22,000 rpm. Failure occurred at the hub which connects the shaft and the composite rotor. The performance of the composite rotor was confirmed in a general sense, and the danger of unexpected failure of composite rotor during high-speed spinning was also demonstrated in this paper. Special attention should be paid to not only composite rotor but also hub when designing a flywheel energy storage system. The telemetry system needs to be further developed, especially enduring the high centrifugal forces, and can be used in a real time monitoring system for the flywheel energy storage system.

A Study on the Evaluation Technique of Quantified Damage for Powertrain System on Traveled Courses (주행노면에 따른 동력장치의 상대 피로 손상도 평가 기법에 관한 연구)

  • Lee, Sang-Ho;Lee, Jeong-Hwan;Kang, Do-Kyung;Goo, Sang-Hwa
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.24 no.12
    • /
    • pp.74-81
    • /
    • 2007
  • This paper focuses on improvement of the reliability for endurance test to serve military automobiles. The driving loads have been measured by use of the wireless telemetry system for the drive shaft of the 4-wheel drive car. In order to analyze the transmission input torque and engine revolution of loads of the test courses and unpaved road have been made use of the revolution counting and cumulative damage by miner's rule. This paper presents the evaluated result for quantified damage about the test courses and roads.

Estimating Bathroom Water-uses based on Time Series Regression (시계열 회귀모형에 기초한 욕실 내 용수 사용량 추정)

  • Myoung, Sungmin;Kim, Donggeon;Jo, Jinnam
    • Journal of the Korea Society of Computer and Information
    • /
    • v.19 no.8
    • /
    • pp.19-26
    • /
    • 2014
  • Analysis of influential factors on water consumption in households will help predicting the water demand of end-use in household and give an explanation to cause on the change of trend. In this research, the data are gathered by radio telemetry system which is combined electronic flow-meter and wireless communication system in 140 household in Korea. Using this data, we estimate for each residential type to determine liter per capita day. we used real data to predict bathtub and washbowl water-uses and compared the ordinary least square regression model and autoregressive regression error model. The results of this study can be applied in the planning stages of water and waste water facilities.

Implementation of a Medical Information Transmission Protocol Based on Mobile Wireless Communication (무선 이동통신 기술에 기반한 의료 정보 전송 프로토콜 구현)

  • 정희창;한민수
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.1
    • /
    • pp.19-24
    • /
    • 1998
  • The main goal of this paper is to propose and to test a radio protocol based CSMA/CA (Carrier Sense Multiple Access with Collision Avoidance) for the purpose of enhancing the existing medical information system. The feature of the new medical information system, Medical Application Radio System(MARS), which operating in real time is the transmission of medical information in bi-direction between the hospital control office and patients mobile stations. MARS monitors patients linked to the network by radio and provides quick alarm, flexible documentation capabilities, asnd fast treatment for the analysis of collected medical data. The existing medical information system, radio telemetry system which transfers the message of patients to the CAP(Central Access Point) unit in one way at the speed of 9.6Kbps and operates a channel frequency bandwidth. To verify the Performance of the proposed system, we have performed the numerical analysis and have implemented a test system which consists of the 2.4Ghz radio transceiver and personal computer.

  • PDF