• Title/Summary/Keyword: Wire structure

Search Result 655, Processing Time 0.031 seconds

First-order Wire-wound SQUID Gradiometer System Having Compact Superconductive Connection Structure between SQUID and Pickup Coil (SQUID와 검출코일의 초전도 결합방식이 개선된 1차 권선형 미분계 시스템)

  • Lee, Y.H.;Yu, K.K.;Kim, J.M.;Kwon, H.;Kim, K.;Park, Y.K.
    • Progress in Superconductivity
    • /
    • v.9 no.1
    • /
    • pp.23-28
    • /
    • 2007
  • In order to have a superconductive connection between the wire-wound pickup coil and input coil, typically Nb terminal blocks with screw holes are used. Since this connection structure occupies large volume, large stray pickup area can be generated which can pickup external noise fields. Thus, SQUID and connection block are shielded inside a superconducting tube, and this SQUID module is located at some distance from the distal coil of the gradiometer to minimize the distortion or imbalance of uniform background field due to the superconducting module. To operate this conventional SQUID module, we need a higher liquid He level, resulting in shorter refill interval. To make the fabrication of gradiometers simpler and refill interval longer, we developed a novel method of connecting the pickup coil into the input coil. Gradiometer coil wound of 0.125-mm diameter NbTi wires were glued close to the input coil pads of SQUID. The superconductive connection was made using an ultrasonic bonding of annealed 0.025-mm diameter Nb wires, bonded directly on the surface of NbTi wires where insulation layer was stripped out. The reliability of the superconductive bonding was good enough to sustain several thermal cycling. The stray pickup area due to this connection structure is about $0.1\;mm^2$, much smaller than the typical stray pickup area using the conventional screw block method. By using this compact connection structure, the position of the SQUID sensor is only about 20-30 mm from the distal coil of the gradiometer. Based on this compact module, we fabricated a magnetocardiography system having 61 first-order axial gradiometers, and measured MCG signals. The gradiometers have a coil diameter of 20 mm, and the baseline is 70 mm. The 61 axial gradiometer bobbins were distributed in a hexagonal lattice structure with a sensor interval of 26 mm, measuring $dB_z/dz$ component of magnetocardiography signals.

  • PDF

Basic Design of Multipurpose Fisheries Base for Marine Ranching Program (바다목장화를 위한 다목적 수산기지의 기초설계)

  • Kim, Hyeon-Ju;Lee, Na-Ry
    • Journal of Ocean Engineering and Technology
    • /
    • v.13 no.4 s.35
    • /
    • pp.143-150
    • /
    • 1999
  • Multipurpose fisheries base was conceptually designed to establish marine ranching system in the coastal waters around Tongyoung, southern sea of Korea. Fisheries base for marine ranching system has integrated various facilities which were required for the process of spawning, rearing, training, releasing, monitoring and catching functions. This base has five steel piles for supporting upper structure and systems. Four steel piles are surrounded by circular net pen made by steel wire, they have the function of the protection against fouling for pile and scouring for bottom soil as well as secondary rearing and short stocking. We can use the last pile to moor a ship and access to the base. Principal structure with steel piles is designed by optimization technique considering design external forces in the coastal waters of return period of 50 years. Design optimization Problem is formulated for this base. Optimal design of multipurpose fisheries base is numerically investigated by sequential quadratic programming method.

  • PDF

Study on the Application of Tuned Pendulum Slab Damper system (TPSD) to Building structure (진자슬래브에 의한 진동제어시스템의 적용성 평가)

  • Kim, Yang-Jung;Seo, Gun-Bae
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2012.11a
    • /
    • pp.181-184
    • /
    • 2012
  • The Tuned Pendulum Slab Damper(TPSD)system is mainly composed of suspended pendulum slab which was hanging with cable wire from the top floor of building without any extra loads structurally, and can be helpful to reduce vibration with effect of tuned mass damper function by the principle of pendulum movement. The experiment was performed with miniatures of the 30stories of steel structure building by the forced vibration test using shaking table, and the result was reduced about 42% of vibration. The purpose of this study was to make analysis of application of the TPSD system to new building and exist building against strong wind or seismic wave. The result of this study was that the TPSD system shall be satisfactory in field of execution, process control, safety and economical efficiency with saving up to 70% of construction cost.

  • PDF

Beam stability improvement of a liquid metal ion source (액체 금속 이온원의 빔 안정도 향상)

  • 현정우;임연찬;김성수;박철우;이종항;강승언
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2004.04a
    • /
    • pp.504-507
    • /
    • 2004
  • Previous studies on the liquid Gallium ion sources used an electro-chemically etched tungsten wire with a coil-type heater. Such a structure requires excessive power consumption in the course of heating the liquid metal. In this work, a new structure is proposed that replaces the coil-type heater. It uses a Gallium reservoir made of six pre-etched 250 $\mu\textrm{m}$ tungsten wires that surround the needle electrode. Gallium loading at the reservoir is observed to be much more stable, resulting in an improved beam stability.

  • PDF

The Effect of Patenting Conditions on the Tensile Property of High Carbon Steels added with Si (Si 첨가 고탄소강의 인장 성질에 미치는 패턴팅 조건의 영향)

  • Lee, J.B.;Lee, S.Y.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.6 no.2
    • /
    • pp.49-58
    • /
    • 1993
  • Isothermal transformation behavior during patenting and variations of microstructure and tensile strength of patented wires were investigated in Si-added high carbon steel. The TTT curves of the steels were made for two different austenitizing temperature. As the salt bath temperature was increased, the observed microstructures were bainite at $450^{\circ}C$, the mixture of bainite and pearlite at $500^{\circ}C$, and to pearlite at $600^{\circ}C$, The tensile strength of patented wire exhibited the highest value when the structure was pearlite. while the bainitic structure showed the lowest.

  • PDF

Electromagnetic Interference Reflectivity of Nanostructured Manganese Ferrite Reinforced Polypyrrole Composites

  • Chakraborty, Himel;Chabri, Sumit;Bhowmik, Nandagopal
    • Transactions on Electrical and Electronic Materials
    • /
    • v.14 no.6
    • /
    • pp.295-298
    • /
    • 2013
  • Nano-size manganese ferrite reinforced conductive polypyrrole composites reveal a core-shell structure by in situ polymerization, in the presence of dodecyl benzene sulfonic acid as the surfactant and dopant, and iron chloride as the oxidant. The structure and magnetic properties of manganese ferrite nano-fillers were measured, by using X-ray diffraction and vibrating sample magnetometer. The morphology, microstructure, and conductivity of the composite were characterized by transmission electron microscopy, Fourier transform infrared spectroscopy, and four-wire technique. The microwave-absorbing properties of composites reinforcement dispersed in resin coating with the coating thickness of 1.2 nm were investigated, by using vector network analyzers, in the frequency range of 8~12 GHz. A reflection loss of -8 dB was observed at 10.5 GHz.

Implementation of Double Resonance in the Cylindrical Monopole (광대역화를 위한 원통형 모노폴 안테나의 이중공진 구조 설계)

  • Chun, Joong-Chang
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.6 no.4
    • /
    • pp.267-271
    • /
    • 2013
  • A new structure of double-resonant cylindrical monopole is proposed for multiple band applications. Multiple band property for the proposed antenna is achieved by adjusting the coupling structure of the antenna base for a double resonance. Measured results of the proposed antenna are compared with those of wire and thick cylinder monopoles.

Bitmap Intersection Lookup (BIL);A Packet Classification's Algorithm with Rules Updating

  • Khunkitti, Akharin;Promrit, Nuttachot
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.767-772
    • /
    • 2005
  • The Internet is a packet switched network which offers best-effort service, but current IP network provide enhanced services such Quality of Services, Virtual Private Network (VPN) services, Distribute Firewall and IP Security Gateways. All such services need packet classification for determining the flow. The problem is performing scalable packet classification at wire speeds even as rule databases increase in size. Therefore, this research offer packet classification algorithm that increase classifier performance when working with enlarge rules database by rearrange rule structure into Bitmap Intersection Lookup (BIL) tables. It will use packet's header field for looking up BIL tables and take the result with intersection operation by logical AND. This approach will use simple algorithm and rule structure, it make classifier have high search speed and fast updates.

  • PDF

An experimental Study of the Wake Flow Past a Rectangular Cylinder (長方形柱 後流에 關한 實驗的 硏究)

  • Nam, Cheong-Do
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.15 no.3
    • /
    • pp.45-56
    • /
    • 1991
  • This paper describes characteristics of the flow pattern of the flow past a rectangular cylinder experimentally investigated. The width-to-length ratio of the section varried from 2 to4. For the statistical treatment, autocorrelation coefficient, probability density function and power spectral density function are obtained by the digital processing technic through on-line system with a hot wire anemometer. As a results, it was found that strong periodic coherent eddies structure is sustained to about 20H downstream from the cylinder. And nearer the cylinder in the wake, the number of turbulent eddies of a large scale coherent structure are comparatively much more dominant than that of a small scale one. By the analysis of power spectrum, It was cleared that there exists a certain range of the width to length ratio between 2.5 and 3 of which the flow pattern changes abruptly with a sudden discontinuity in Strouhal number.

  • PDF

Seismic performances of steel reinforced concrete bridge piers

  • Deng, Jiangdong;Liu, Airong;Yu, Qicai;Peng, Guoxing
    • Steel and Composite Structures
    • /
    • v.21 no.3
    • /
    • pp.661-677
    • /
    • 2016
  • The quasi static test of the steel reinforced concrete (SRC) bridge piers and rigid frame arch bridge structure with SRC piers was conducted in the laboratory, and the seismic performance of SRC piers was compared with that of reinforced concrete (RC) bridge piers. In the test, the failure process, the failure mechanism, hysteretic curves, skeleton curves, ductility coefficient, stiffness degradation curves and the energy dissipation curves were analyzed. According to the $M-{\Phi}$ relationship of fiber section, the three-wire type theoretical skeleton curve of the lateral force and the pier top displacement was proposed, and the theoretical skeleton curves are well consistent with the experimental curves. Based on the theoretical model, the effects of the concrete strength, axial compression ratio, slenderness ratio, reinforcement ratio, and the stiffness ratio of arch to pier on the skeleton curve were analyzed.