• 제목/요약/키워드: Wire resistance

검색결과 406건 처리시간 0.027초

YBCO Coated Conductor의 과전류 특성해석 (Analysis of Over-current Characteristics in YBCO Coated Conductor)

  • 이찬주;남관우;강형구;고태국;석복렬
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 B
    • /
    • pp.693-694
    • /
    • 2006
  • In order to develop a high temperature superconducting(HTS) coil for the fault current limiter(FCL), the over-current characteristics in YBCO coated conductor(CC) with Ni-W alloy substrate are analyzed. The HTS wire is wound by bifilar winding method for resistive current limitation and it is operated in 65K sub-cooled nitrogen. In order to analyze the resistance and the temperature characteristics of the CC wire, an analysis program is developed considering all the composition materials except the buffer layer. Using this program, the temperature rise, the resistance development and the current limitation of CC are calculated depending on the applied voltage and the stabilizer materials. According to the analysis results, under the temperature restriction of 300K, the maximum voltage per meter is determined as 40V/m if the stabilizer is $25{\mu}m$ thick stainless steel at each side. Finally, the wire length needed for the distribution level HTS FCL is estimated.

  • PDF

카본열선을 사용하는 전기장판의 국부가열에 의한 화재원인 분석 (Fire Cause Analysis of Local Heating on Carbon Type Hot Wire Electric Pad)

  • 송재용;김진표;남정우;사승훈
    • 한국화재소방학회논문지
    • /
    • 제24권4호
    • /
    • pp.104-108
    • /
    • 2010
  • 본 논문은 카본열선을 사용하는 전기장판에서 발생한 전기화재에 관하여 기술하였다. 카본열선을 사용하는 전기장판은 카본 재질의 특성상 전기용접이나 납땜 등의 방법으로 접속이 불가능하며, 열선 끝단을 카본 재질의 연결부를 만들어 접속해야 한다. 이러한 과정에서 열선 사이의 불완전 접속이 발생되며, 불완전 접속부에는 접촉저항의 증가로 국부적인 발열이 발생되고, 최종적으로 화재사고로 진전된다. 본 논문에서는 카본 열선 접속부에서 불완전 접속이 형성되는 경우, 접속부에서 전기적 발열에 의해 발생되는 열선의 손상 형태를 분석하여 화재원인을 규명하였다. 이러한 분석 결과는 카본 열선을 사용하는 전기장판의 화재원인 조사의 기초 자료로 활용 가능할 것으로 기대한다.

A study on the TiN coating applied to a rolling wire probe

  • Song, Young-Sik;S. K. Yang;Kim, J.
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2003년도 추계학술발표회초록집
    • /
    • pp.118-118
    • /
    • 2003
  • In a rolling wire probe, a key component of an inspection apparatus for PDP electrode patterns, the electric performance of it is known to be strongly dependent on the surface condition of a collet pin, a needle pin, and a wire. However, the collet and needle pins rotate very rapidly in contact with each other, which results in the degradation of the surface by the heat and friction and finally the formation of black wear marks on the surface after a several hundred hours test. Once the black wear marks appear on the surface, the electric resistance of the probe increases sharply and so the integrity of the probe is severely damaged. In this experiment, TiN coating, which has excellent electric conductances and good wear-resistance, has been applied on the surface of collect and needle pins for preventing the surface damages. In order to achieve the homogeneous coating with a good adhesion property, special coating substrate stages and jigs were designed and applied during coating. TiN has been deposited using 99.999% Titanium target by a DC reactive sputtering method. According to the components and jigs, processing parameters, such as DC power, RF bias and the flow rate ratio of Ar and N$_2$ used as reactive gases, has been controlled to obtain good TiN films. Detailed problems and solutions for applying the new substrate stages and jigs will be discussed.

  • PDF

동피복 복합선재 제조를 위한 연속주조공정의 최적화 (The Optimization of Continuous Casting Process for Production of Copper Clad Steel Wire)

  • 조훈;김대근;황덕영;조형호;김윤규;김영직
    • 한국주조공학회지
    • /
    • 제25권6호
    • /
    • pp.259-264
    • /
    • 2005
  • The copper clad steel wire is used extensively as lead wires of electronic components such as capacitors, diodes and glass sealing lamp because the wire combines the strength and low thermal expansion characteristic of Fe-Ni steel with the conductivity and corrosion resistance of copper. In order to fabricate the copper clad steel wire, several processes including electro-plating, tubecladding extrusion process and dip forming process have been introduced and applied. The electroplating process for the production of copper clad steel wire shows poor productivity and induces environmental load generation such as electroplating solution. The dip forming process is suitable to mass production of copper clad steel such as trolley wire. and need expensive manufacturing facilities. The present paper describes the improvement of the conventional continuous casting process to fabricate copper clad steel wire, which its core metal is low thermal expansion Fe-Ni alloy and its sheath material is copper. In particular, the formation of intermetallic compound at interface between core and sheath was investigated in order to introduce optimum continuous casting process parameter for fabrication of copper clad steel wire with higher electrical conductivity. The mechanical strength of copper clad steel wire was also investigated through wiredrawing process with of 95% in total reduction ratio.

쓰레기 매립지 가스 포집관에서 가스조성에 따른 계측오차의 최소화 (Minimizing the Measurement Error from Gas Compositions of Gas Vent in Sanitary Landfill)

  • 이해승;이문형
    • 환경위생공학
    • /
    • 제17권1호
    • /
    • pp.28-35
    • /
    • 2002
  • 본 연구 목적은 계측저항이 없는 열선유속계를 이용하여 매립지 가스의 유량을 산정할 때 가스조성에 의해 발생되는 계측오차를 최소화할 수 있는 방안을 제시하고자하였다. Rotor meter와 가스조성 밀도를 이용하여 산정한 관 중심유속을 계측저항이 없는 열선유속계를 이용하여 구한 관 중심유속을 비교함으로서 계측오차를 측정하였다. 실험결과 열선 유속계와 rotor meter를 이용한 매립지 가스유속 계측오차의 최소화 방안을 통하여 매립지 가스유량의 오차 범위를 10% 이내로 최소화 할 수 있는 것으로 조사되었다.

코로나 방전에 의한 방진/의료용 마스크 여과재의 기능화 가공 (Functional Finishing of Nonwoven Filter for Dust-proof/Medical Masks by Corona Discharging Treatment)

  • 홍영기
    • 한국염색가공학회지
    • /
    • 제25권3호
    • /
    • pp.232-239
    • /
    • 2013
  • In this study, 25gsm melt-blown polypropylene nonwoven for dust-proof/medical masks was finished by the corona discharging treatment. The influence of corona discharging parameters on the filtration efficiency was investigated. Several parameters such as discharging voltage, discharging speed, distance to discharging wire and configuration of discharging system had an effect on filtration efficiency, while the parameters had no effect on breathing resistance. Optimum corona discharging conditions are as follows: Wires were installed on the upper part of the nonwoven and paper pipe was installed on the lower part of the nonwoven having a distance of 5cm. The sequence of wire voltages was +60 kV, +60 kV, 0, -60 kV, and -60 kV. The discharging voltage and speed were 60 kV and 30m/min respectively. The nonwoven treated by corona discharging at the optimum condition showed a filtration efficiency of 80% or more, which is suitable for dust-proof/medical masks.

가공지선이 연결된 송전철탑의 탑각저항 측정에 관한 연구 (A Study on the Measurement of Footing Resistance of Transmission Towers with Overhead Grounding wires)

  • 이원교;최종기;이영우;최인혁;김경철
    • 한국전기전자재료학회논문지
    • /
    • 제23권1호
    • /
    • pp.61-64
    • /
    • 2010
  • Footing Resistance of a 154 kV transmission towers in korea is commonly required to be less than 15 ohm to avoid lightning back-flashover accident. The periodic measurement of Footing Resistance is important to verify that the grounding performance of the towers has been maintained good. Towers are electrically connected in parallel with overhead grounding wire, therefore footing resistance of each tower will be measured after disconnecting the overhead ground wires from the towers. however, In this paper, three direct measurement methods of footing resistance are presented. There are very useful methods without disconnecting overhead ground wires from the tower under measurement. They are compared in KEPCO 154 kV transmission towers. The experimental results describe performances of them.

SUS 304 마이크로 와이어 직선화 처리에 관한 연구 (Study on Micro Wire Straightening Process in SUS 304)

  • 신홍규;김남수;김웅겸;홍남표;김병희;김헌영
    • 산업기술연구
    • /
    • 제24권A호
    • /
    • pp.17-22
    • /
    • 2004
  • In the study, we have developed a straightening system for 304 micro wires that are normally used in the medical and semi-conductor fields. To apply heat to the micro wires, we introduced the direct wire heating method which generates the thermal energy by the electrical resistance of the wire itself. To avoid the deterioration of the wire surface by the environment, such as the oxidation or the hydration, the $N_2$ gas was filled in the glass pipe in which the straightening process was being performed. A precision tension meter was also attached to control the tension of the wire during the heating and straightening process. In order to control the straightening process, several experimental investigations with varying the tension, the feeding velocity and the temperature (current) was carried out. As a result of experiments, we obtained the optimal processing conditions satisfying the straightness requirement of the micro wires.

  • PDF

용접 조건이 소형 용기용 Sn 도금 강재의 와이어 심 용접성에 미치는 영향 (Effect of Welding Parameters on Wire Seam Weldability of Tin Coated Steels for Small Containers)

  • 김기철;이기호;이목영
    • Journal of Welding and Joining
    • /
    • 제15권5호
    • /
    • pp.74-83
    • /
    • 1997
  • Effect of welding parameters such as current, speed and electrode pressure on the weld quality of tin coated steels for small containers was discussed in this paper. Welding was performed with low frequency wire seam welding system which was loaded with 1.5mm in diameter copper wire electrode. The welding parameters were monitored at the position close to the welding spot so as to minimize the instrumentation error, and the signals were stored into a digital data acquisition system before analysis. Results showed that critical current for sufficient nugget size increased as the base material thickness increased, while the width of the optimum welding range was reduced. The acceptable welding condition derived from this study was found to be effective within the thickness range of $\pm$10% of the nominal (0.25mm) thickness. Tin coating layer was proved not to affect seriously on the weld quality, i.e. strength and formability, since consumable wire electrode was used in this process. Test results also demonstrated that the welding current was thought to be the most effective parameter to form an acceptable weld, while welding speed or electrode pressure exerted less effect on the nugget formation. However, these two parameters played an important role because the former was related to the nugget overlap interval, and the latter, to the formation of expulsion during welding.

  • PDF

Enhancing seismic performance of ductile moment frames with delayed wire-rope bracing using middle steel plate

  • Ghalandari, Akram;Ghasemi, Mohammad Reza;Dizangian, Babak
    • Steel and Composite Structures
    • /
    • 제28권2호
    • /
    • pp.139-147
    • /
    • 2018
  • Moment frames have considerable ductility against cyclic lateral loads and displacements; however, sometimes this feature causes the relative displacement to exceed the permissible limits. This issue can bring unfavorable hysteretic behavior on the frame due to the reduction in the stiffness and resistance against lateral loads. Most of common bracing systems usually control lateral displacements through increasing stiffness while result in decreasing the capacity for energy absorption. This has direct effect on hysteresis curves of moment frames. Therefore, a system that is capable of both having the capacity of energy absorption as well as controlling the displacements without a considerable increase in the stiffness is quite important. This paper investigates retrofitting of a single-storey steel moment frame using a delayed wire-rope bracing system equipped with the ductile middle steel plate. The steel plate is considered at the middle intersection of wire ropes, where it causes cables to be continuously in tension. This integrated system has the advantage of reducing considerable stiffness of the frame compared to cross bracing systems as a result of which it could also preserve the frame's energy absorption capacity. In this paper, FEM models of a delayed wire-rope bracing system equipped by steel plates with different geometries have been studied, validated, and compared with other researchers' laboratory test results.