• 제목/요약/키워드: Windows7

검색결과 610건 처리시간 0.029초

한방간호에 대한 간호학생들의 인식 및 태도에 대한 예비연구 (A Pilot Study in Cognition and Attitude of Nursing Students on Oriental Nursing)

  • 한상숙;김원옥;원정숙;현경선;최경옥;장경화;이미애;김숙영;전은영;김정숙;이은숙;배영숙
    • 동서간호학연구지
    • /
    • 제8권1호
    • /
    • pp.81-88
    • /
    • 2003
  • This research has been conducted to examine the cognition and attitude of nursing students on Oriental Nursing, the subject of this research being 789 nursing students from 9 different universities who took the Oriental Nursing class. A questionnaire, the construct validity and reliability of which have been verified through enquiries into records and references as well as preliminary researches, was used as a research tool. The questionnaire, a set of 86 questions, was developed by the researchers of this study, and the reliability of the questionnaire is Cronbach's=.85. The collected data have been analysed using SPSS windows programme 11.0 for t-test and ANOVA, and the results are as follows: 1. There was a significant difference in cognition and attitude points according to the academic year (F=14.15, p=.000). After the post-hoc test, it was revealed that the points of the students in their 4th year were significantly higher than the points of the students in their 2nd or 3rd year. 2. There was a significant difference in cognition and attitude points according to the credits the students have taken (F=28.66, p=.000). After the post-hoc test, it was revealed that the points of the students who have taken from $3{\sim}5$ to $6{\sim}8$ credits were significantly higher than the points of those who have taken from 1 to 2 credits. 3. There was a significant difference in cognition and attitude points according to the period of time the students have experienced Oriental Nursing (F=32.06, p=.000). After the post-hoc test, it was revealed that the points of the students who have practised Oriental Nursing from 1 to 2 weeks were significantly higher than the points of those who have not practised it at all. 4. There was no significant difference in cognition and attitude points according to the treatment or hospitalisation of the students themselves or their family members. 5. The cognition and attitude points of the students who are deeply interested in Oriental Nursing were significantly higher than the points of those who are not (t=8.83, p=.000). 6. The cognition and attitude points of the students who have higher expectations for the development of Oriental Nursing were significantly higher than the points of those who have not(t=5.90, p=.000). 7. The cognition and attitude points of the students who believe that the Oriental Nursing will contribute to the expansion of the roles of nurses were significantly higher than the points of those who do not (t=6.60, p=.000). 8. The cognition and attitude points of the students who expect that the Oriental Nursing will be effective in prevention of chronic diseases were significantly higher than the points of those who do not (t=5.80, p=.000). According to the results above, it was confirmed that proper education on Oriental Nursing can have affirmative effects on the cognition and attitude of the nursing students towards Oriental Nursing.

  • PDF

물리적 요소가 SPECT 영상에 미치는 영향 (The effects of physical factors in SPECT)

  • 손혜경;김희중;나상균;이희경
    • 한국의학물리학회지:의학물리
    • /
    • 제7권1호
    • /
    • pp.65-77
    • /
    • 1996
  • 본 연구는 2-D 와 3-D 호프만 뇌 모형 ,3-D 제젝 모형, 그리고 단일광자방출전산화단층촬영을 이용하여 인공산물을 일으키는 요인중 자료 획득 요소, 감쇠, 잡음, 산란 그리고 재구성 방식이 영상에 미치는 영향을 분석, 평가하였다. 자료 획득 요소 중 섬광 카메라의 회전 각도와 반경을 각각 변화시키면서 영상을 획득하였다. 이때 회전 반경의 변화가 작을수록 더 우수한 질의 영상을 얻을 수 있었고 회전중심으로부터 반경이 짧을수록 영상이 더 우수하였으며 이는 모형에서 거리가 멀어질수록 조준기의 분해능이 떨어지기 때문이다. 제젝 모형에서 균일한 부위를 각 조준기에 대해 알맞는 감쇠계수를 찾는데 이용하였다. $^{99m}$ Tc 을 사용했을 때 각 조준기에 대해 가장 알맞는 감쇠계수는 모두 0.12$cm^{-1}$ /로 나타났으며, 이 값으로 각각의 영상에 대해 감쇠 보정을 해주었다. 감쇠 보정 전의 제젝 모형의 균일한 부위는 감쇠로 인해 움푹 패인 선 프로파일 모양을 나타내었고, 감쇠 보정을 해줌으로서 평행한 선 프로파일을 얻을 수 있었다. 또한 감쇠 보정을 해줌으로서 영상의 질을 개선할 수 있었다. 각 시간에 따른 잡음의 영향을 관찰하기 위해 1분, 2분, 5분, 10분, 20분에 대하여 각각 자료를 얻었다. 결과에서 1분 영상이 잡음의 영향을 가장 많이 받아 영상의 질이 나빴으며 반면에 20분 영상은 잡음의 영향을 적게 받아 영상의 질이 상대적으로 가장 좋았다. 이는 자료 획득 시간을 길게하여 계수되는 양을 늘려줌으로서 Poisson 분포를 따르는 방사능 분포의 통계적 오차를 줄일 수 있기 때문인 것으로 생각한다. 이중-에너지 창, 즉 산란 부분과 $^{99m}$ Tc 의 봉우리 에너지인 140KeV 중심 20% 에너지 구별 영역을 각각 설정한 후, 자료를 얻어 산란 보정 전과 후의 영상을 비교하였다. 제젝 모형의 경우 냉구 부위와 바 패턴 부위가 산란 보정 이전에 비해 산란 보정 이후가 더 잘 식별되었고, 3-D 호프만 뇌모형의 경우 산란 보정후 영상의 질이 더 우수하게 나타났다. 결론적으로 SPECT 영상이 자료 획득을 위한 매개변수, 감쇠, 잡음, 산란 그리고 재구성 방식에 많은 영향을 받는 것으로 나타났으며 임상 적용시 유용한 SPECT 자료를 얻기 위해서 이러한 인자들을 최적화 또는 보정해 주어야 할 것으로 생각된다.

  • PDF

한국인의 반복자연유산 환자에서 Thymidylate Synthase Enhancer Region (TSER) 돌연변이형의 혈중 호모시스테인 양과의 관련성 (Contribution of Thymidylate Synthase Enhancer Region (TSER) Polymorphism to Total Plasma Homocysteine Levels in Korean Patients with Recurrent Spontaneous Abortion)

  • 최윤경;강명서;김남근;김선희;최동희;안명옥;이수만
    • Clinical and Experimental Reproductive Medicine
    • /
    • 제31권3호
    • /
    • pp.183-190
    • /
    • 2004
  • Objectives: Methylenetetrahydrofolate reductase (MTHFR) mutation are commonly associated with hyperhomocysteinemia, and through their defects in homocysteine metabolism, they have been implicated as a risk factor for recurrent spontaneous abortion. Recent report describe that 28-bp tandem repeat polymorphism in thymidylate synthase enhancer region (TSER) that influence enzyme activity would affect plasma homocysteine level. We have investigated the relationship between TSER genotype and plasma homocysteine level in 54 patients with recurrent spontaneous abortion. Methods: Plasma homocysteine level was measured by fluorescent polarizing immunoassay. MTHFR mutation (C677T and A1298C) was identified by PCR-restriction fragment length polymorphism assay and TSER mutation was analyzed by PCR method. The data were analyzed using the program SAS 8.2 for Windows. Results: Total homocysteine level was significantly higher in MTHFR 677TT genotype ($9.80{\pm}3.87{\mu}mol/L$) than MTHFR 677CC genotype ($8.14{\pm}1.74{\mu}mol/L$) in Korean patients with unexplained recurrent spontaneous abortion (p=0.0143). However, the plasma homocysteine level was not significantly different in the MTHFR 1298AA ($8.42{\pm}2.65{\mu}mol/L$) and 1298CC ($6.09{\pm}0.32{\mu}mol/L$; p=0.2058) and, TSER 2R2R ($8.61{\pm}1.68{\mu}mol/L$) and 3R3R ($8.05{\pm}2.81{\mu}mol/L$; p=0.9319) mutant genotypes, respectively. In this study, we found the combination effects of TSER and MTHFR C677T genotypes. Plasma homocysteine levels were the highest ($11.47{\pm}4.66{\mu}mol/L$) in individuals with TSER 3R3R ($8.05{\pm}2.81{\mu}mol/L$) and MTHFR 677TT ($9.80{\pm}3.87{\mu}mol/L$) genotypes. Individuals with a combination of both TSER 2R2R/2R3R and MTHFR 677CC/CT genotypes ($7.69{\pm}1.77{\mu}mol/L$) had lower plasma homocysteine levels than TSER 2R2R ($8.61{\pm}1.68{\mu}mol/L$) and MTHR 677CC ($8.14{\pm}1.74{\mu}mol/L$) genotypes, respectively. The effect of MTHFR polymorphism in the homocysteine metabolism appears to be stronger than that of TSER polymorphism. Conclusion: Although statistically not significant, we found the elevated level of plasma homocysteine in combined genotypes with TSER and MTHFR (C677T and A1298C) in Korean patients with unexplained habitual abortion. In this study, we reported the possibility that TSER polymorphism is a genetic determinant of plasma homocysteine levels in the Korean patients as well as MTHFR C677T polymorphism. A large prospective study is needed to verify our findings.

연지(蓮池)로 본 성혈사 나한전 꽃살문양의 생태미학과 상징성 (An Ecological Aesthetics and Symbolism of the Seonghyelsa Nahanjeon Floral Lattice with Patterns of Lotus Pond Scenery)

  • 노재현;이다영;최승희
    • 한국전통조경학회지
    • /
    • 제36권3호
    • /
    • pp.160-171
    • /
    • 2018
  • 꽃창살은 사찰경관을 구성하는 조형요소이며 조망시점이 외부에서 형성되는 장식적 경관요소라는 인식 아래, 경북 영주시 성혈사 나한전의 꽃창살에 표현된 연지의 생태미학적 특성과 도입된 소재의 상징성을 분석 해석한 본 연구의 결과는 다음과 같다. 나한전 정칸 창호에는 사각형 2개가 연속된 문틀 등 비목재 부분을 제외하고 총 176개의 순수 문양이 조각되어 있다. 그 중 중문 어칸(御間) 문살의 기본 개념은 전통정원에서 방지(方池)를 상징하는 연지의 설계언어로 판단된다. 창살 어칸에서 가장 비중이 높은 식물인 연꽃은 '청정(淸淨)'과 '불염(不染)' 그리고 불교의 극락세계인 연화장세계로 인식되며 꽃창살에 묘사된 연꽃은 생성소멸의 특징을 담은 다채로운 형태로 펼쳐져 있어 불연일체(佛蓮一體)의 경관상(景觀像)이 잘 드러나고 있다. 또한 네가래와 벗풀은 실제 연못 주변에서 발견되는 수생식물로 생태적 측면에서도 연지의 수생태계와도 부합되는 사실적 표현일 뿐 아니라 물총새, 백로, 왜가리 등 날짐승의 표현은 정적인 수생태계에 동세와 활력을 불어넣고자 한 생태미학적 발상이다. 또한 동자승을 비롯하여 수(壽) 부(富) 귀(貴) 다남(多男) 등의 기복사상을 구현하고자 한 것으로 판단되는 물총새, 기러기(백로), 물고기, 참게, 개구리 그리고 용 등 7개 분류형의 동물들과 식물이 공생하는 연지풍경을 꽃창살에 연출하였다. 성혈사 나한전 어칸의 꽃창살은 연과 연잎의 생성과 소멸, 서식처의 생태적 적지(敵地), 공생과 먹이연쇄 등 수생태계 측면에서도 매우 부합되는 표현으로 가득하며 이는 상징과 생태미학의 총화이자연지 풍경의 총합적 어울림이다.

황사 발생시 아파트 실내에서 미세먼지 크기별 농도 특성 (Characteristics of Indoor Particulate Matter Concentrations by Size at an Apartment House During Dusty-Day)

  • 주상우;지준호
    • 한국입자에어로졸학회지
    • /
    • 제15권1호
    • /
    • pp.37-44
    • /
    • 2019
  • 본 연구에서는 국내에서 가장 일반적인 유형의 주택으로서 3인 가구가 거주하는 공급면적 $117.69m^2$의 일반형 아파트를 측정 주택으로 선정하여 실증 측정을 진행하였다. 황사 발생이 포함된 3일 측정기간 동안 미세먼지 변화 특성을 관찰하여 분석하였다. 관측된 미세먼지($PM_{10}$)를 상대적으로 큰 먼지($PM_{10-2.5}$)와 초미세먼지($PM_{2.5}$)로 나누어 대기와 실내의 먼지의 농도변화를 분석하였다. 연구 결과로 재실자의 활동이 없는 외출이나 취침 기간에는 주택의 침기 특성을 확인할 수 있었다. 미세먼지 중 상대적으로 큰 $PM_{10-2.5}$ 크기 입자는 외기의 풍속이 5 m/s까지 증가하여 침기량이 증가해도 대기 농도 대비 실내 농도비가 7% 이하인 반면, $PM_{2.5}$의 경우 외기 속도가 5 m/s까지 증가하면 50% 이상으로 증가하였다. 황사가 심한 대기 상태에도 본 연구의 측정 주택의 경우 실내 $PM_{10-2.5}$는 시평균$15{\mu}g/m^3$로 대기 농도의 5% 수준으로 일상 조건과 비슷했다. 재실자의 활동이 있는 경우에는 미세먼지 중 초미세먼지를 제외한 상대적으로 큰 먼지는 자연환기와 실내 사람의 움직임과 같은 행동 영향이 지배적이었다. 실내 $PM_{10-2.5}$ 농도는 대기 농도가 낮은 경우에는 대기 농도의 약 50%를 차지하는 경우도 있었다. 재실자의 활동 중, 초미세먼지의 발생이 클 것으로 예상되는 굽기나 튀기기가 포함된 조리나 실내 흡연이 없었기 때문에, 재실자가 없는 경우와 마찬가지로 초미세먼지는 실내 농도가 실외 농도의 추이에 따라 함께 변동하는 양상을 보였다. 외부공기가 침기에 의해 창틈, 문틈으로 유입되는 과정에서 초미세먼지는 약 30~40% 정도가 제거되고 실내로 많은 비율이 유입되기 때문에 실외 초미세먼지의 실내에 대한 영향이 컸다. 본 연구의 분석 데이터는 측정이 이루어진 대표 주택에 해당하는 것으로, 새로 지어진 기밀 성능이 높은 신축 아파트나 침기가 상대적으로 클 것으로 예상되는 오래된 단독주택에서는 다른 특성이 나타날 것으로 예상되므로, 이에 대한 추가적인 연구가 필요하다고 생각된다.

Open Source를 이용한 MicroPACS의 구성과 활용 (Application of MicroPACS Using the Open Source)

  • 유연욱;김용근;김영석;원우재;김태성;김석기
    • 핵의학기술
    • /
    • 제13권1호
    • /
    • pp.51-56
    • /
    • 2009
  • 목적 : Small-scalled PACS, Pc-based PACS로 표현되는 MicroPACS 시스템 구축에 대한 관심도가 급격하게 증가하고 있는 추세이다. MicroPACS 시스템은 PACS를 작은 규모에서 사용할 수 있도록 구성해놓은 것이고, 이 시스템을 구성하기 위해서는 DICOM viewer나 연결프로그램 등이 필요하다. 이것은 공개소스프로그램(Open Source Program)을 통해서 어느 누구나 쉽게 무료로 다운로드를 받을 수 있게 되어있다. 본 논문은 Open source program으로 MicroPACS를 직접 구성해보았고, 저장매체로서의 활용가치를 측정하기위하여 성능, 안정성 측면에서 기존의 광 저장매체(CD, DVDRAM)와 비교 분석하였다. 실험재료 및 방법 : 1. 소형 PACS를 구축하기 위해서 먼저 다음 기준에 맞는 DICOM Server Software를 검색한다. (1) 윈도우체제에서 사용가능할 것. (2) Free ware일 것. (3) PET/CT scanner와 호환되어야 할 것. (4) 사용하기 쉬워야 할 것. (5) 저장의 한계가 없어야 할 것. 2. (1) MicroPACS의 성능을 평가하기 위해 환자 1명의 Data ($^{18}F$-FDG Torso PET/CT)를 현재 Back-up장치로 쓰이는 광 저장매체(CD, DVD-RAM)와 MicroPACS에 저장하는데 소요되는 시간(Back up time)과 workstation으로 복구되기까지의 시간(Retrieval time)을 비교해 보았다. (2) PET/CT 검사를 시행했던 환자 1명의 병록번호와 검사 시행날짜를 핵의학과 직원 7명을 대상으로 알려주고 Data를 찾는데 소요되는 시간을 MicroPACS와 광 저장매체(CD, DVD-RAM)에서 각각 측정하여 비교하였다. 3. 기존의 백업장치로 쓰였던 CD들 중에서 2004년부터 2006년까지 500장을 무작위로 뽑아서 loading을 하였고 그중에서 얼마만큼의 에러가 발생하였는지를 측정하여 MicroPACS의 안정성을 비교평가하였다. 결과 : 1. Server와 DICOM viewer 기능을 갖춘 11개의 open source software 중에서 Conquest DICOM Server를 선택하였다. 2. (1) Backup과 Retrieval 시간 비교(단위 : 분)는 다음과 같다; DVD-RAM(5.13,2.26)/Conquest DICOM Server (1.49,1.19) by GE DSTE (p<0.001), CD (6.12,3.61)/Conquest (0.82,2.23) by GE DLS (p<0.001), CD (5.88,3.25)/Conquest (1.05,2.06) by SIEMENS. (2) CD ($156{\pm}46$초), DVD-RAM ($115{\pm}21$초) and Conquest DICOM Server ($13{\pm}6$초). 3. 1년간 MicroPACS에서의 데이터손실은 없었으며(0%), 500장의 CD 중에서 14개(2.8%)가 Loading하는데 실패하였다. 결론 : 현재 많은 병원에서 도입되고 있는 Full PACS를 open source software를 통하여 소규모의 PACS로 재현해 보았고, 그 결과 가능하다는 결론이 나왔다. 데이터 저장의 유용성을 평가한 결과에서 MicroPACS를 이용하는 것이 기존의 광저장매체를 사용하는 것보다 효율적이고 작업속도가 향상 된다는 것을 확인할 수 있다.

  • PDF

유전자 알고리즘을 이용한 다분류 SVM의 최적화: 기업신용등급 예측에의 응용 (Optimization of Multiclass Support Vector Machine using Genetic Algorithm: Application to the Prediction of Corporate Credit Rating)

  • 안현철
    • 경영정보학연구
    • /
    • 제16권3호
    • /
    • pp.161-177
    • /
    • 2014
  • 기업신용등급은 금융시장의 신뢰를 구축하고 거래를 활성화하는데 있어 매우 중요한 요소로서, 오래 전부터 학계에서는 보다 정확한 기업신용등급 예측을 가능케 하는 다양한 모형들을 연구해 왔다. 구체적으로 다중판별분석(Multiple Discriminant Analysis, MDA)이나 다항 로지스틱 회귀분석(multinomial logistic regression analysis, MLOGIT)과 같은 통계기법을 비롯해, 인공신경망(Artificial Neural Networks, ANN), 사례기반추론(Case-based Reasoning, CBR), 그리고 다분류 문제해결을 위해 확장된 다분류 Support Vector Machines(Multiclass SVM)에 이르기까지 다양한 기법들이 학자들에 의해 적용되었는데, 최근의 연구결과들에 따르면 이 중에서도 다분류 SVM이 가장 우수한 예측성과를 보이고 있는 것으로 보고되고 있다. 본 연구에서는 이러한 다분류 SVM의 성능을 한 단계 더 개선하기 위한 대안으로 유전자 알고리즘(GA, Genetic Algorithm)을 활용한 최적화 모형을 제안한다. 구체적으로 본 연구의 제안모형은 유전자 알고리즘을 활용해 다분류 SVM에 적용되어야 할 최적의 커널 함수 파라미터값들과 최적의 입력변수 집합(feature subset)을 탐색하도록 설계되었다. 실제 데이터셋을 활용해 제안모형을 적용해 본 결과, MDA나 MLOGIT, CBR, ANN과 같은 기존 인공지능/데이터마이닝 기법들은 물론 지금까지 가장 우수한 예측성과를 보이는 것으로 알려져 있던 전통적인 다분류 SVM 보다도 제안모형이 더 우수한 예측성과를 보임을 확인할 수 있었다.

방사선종양학과에 근무하는 방사선사의 조직몰입, 직무몰입, 직무만족이 전문 직업성에 미치는 영향 (The Influence of Organizational Commitment, Job Commitment and Job Satisfaction on Professionalism Perceived by Radiotechnologists Working in the Department of Radiation Oncology)

  • 김양수;이선영;이준성;곽근택;박주경;이승훈;황호인;차석용
    • 대한방사선치료학회지
    • /
    • 제24권2호
    • /
    • pp.67-75
    • /
    • 2012
  • 목 적: 본 연구는 방사선종양학과에 근무하는 방사선사들의 전문 직업성을 확인하고, 조직몰입, 직무몰입, 직무만족이 전문직업성에 미치는 영향요인을 파악하며, 이들 상호관련성을 분석하여 향후 방사선사들의 전문 직업성 향상을 위한 기초자료로 제공하고자 시행하였다. 대상 및 방법: 본 연구는 2012년 3월 2일부터 3월 30일까지 방사선종양학과에 근무하는 방사선사를 대상으로 E-mail 설문조사를 하였으며, 설문 응답자 272명 대상으로 하였다. 자료는 SPSS 13.0 for Window를 사용하여 분석하였다. 일반적 특성은 빈도, 백분율로 제시하였으며, 일반적 특성과 전문 직업성 차이는 t-test와 ANOVA를, 전문 직업성, 조직/직무몰입, 직무만족과의 상관관계는 Pearson Correlation 계수를 사용하였으며, 관련변인이 전문 직업성에 영향을 미치는 요인은 다단계 다중회귀분석을 적용하여 분석하였다. 결 과: 전문 직업성 정도는 하위영역에서 자체규정에 대한 신념 $17.74{\pm}2.32/3.55{\pm}.46$, 소명의식 $17.58{\pm}2.63/3.52{\pm}.53$, 전문조직의 준거성 $17.14{\pm}2.39/3.43{\pm}.48$, 공적 서비스 $15.97{\pm}2.48/3.19{\pm}.50$, 자율성 $15.68{\pm}2.28/3.14{\pm}.46$점 순의 결과를 보였으며, 전체 평균은 $83.89{\pm}7.63$점(Summation of Items)/$3.37{\pm}.49$점(Numbers of Items)이었다. 일반적 특성과 전문 직업성의 통계적 관계에서는 연령(P<.001), 근무기간(P<.001), 교육수준(P<.05), 월수입(P<.001), 전문방사선사 자격증취득 유무(P<.001), 직위(P<.001), 전문성 발전기회(P<.001) 등이 통계적으로 유의하였다. 조직몰입, 직무 몰입, 직무 만족의 결과는 조직몰입 전체 평균$80.10{\pm}8.15/3.34{\pm}.34$이며, 하위영역에서 정서몰입 $28.64{\pm}4.61/3.58{\pm}.58$, 유지적 몰입 $27.54{\pm}4.22/3.44{\pm}.53$, 규범적 몰입 $23.95{\pm}2.94/2.99{\pm}.37$ 순으로 높게 나타났으며, 직무몰입의 평균점수는 $32.47{\pm}5.77/3.30{\pm}.60$, 직무만족의 평균점수는 $63.39{\pm}10.16/3.17{\pm}.51$점이었다. 전문 직업성과 조직 몰입, 직무 몰입, 직무 만족의 상관관계는 전문 직업성은 조직몰입과 정적인 상관관계(r=.522, P<.05), 직무몰입과 정적 상관관계(r=.444, P<.05), 직무만족과 정적 상관관계(r=.507, P<.05)를 보였으며, 조직몰입은 직무몰입과 정적 상관관계(r=.549, P<.05), 직무만족과 정적 상관관계(r=.433, P<.05)를 보였으며, 직무몰입은 직무만족과 정적 상관관계(r=.462, P<.05)를 나타냈다. 다중회귀분석의 결과를 보면 최종모형은 정서몰입(B=.755, P<.05), 규범적 몰입(B=.305, P<.05), 직무만족(B=.092, P<.05), 전문성발전기회(B=-1.505, P<.05), 직위(B=-1.155, P<.05) 순으로 나타났으며, 미치는 영향을 설명하는 $R^2$=.504로 나타났다. 결 론: 방사선종양학과에 근무하는 방사선사들의 전문 직업성 정도와 미치는 영향 요인의 결과는 정서몰입, 규범몰입, 직무만족이 높을수록 전문 직업성 높으며, 전문성 발전기회가 적고 직위가 낮은 방사선사들에게 좀 더 다양하고 많은 기회가 주어진다면 전문 직업에 대한 의식이 높아질 것으로 생각된다.

  • PDF

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF