RF Sputtered $SnO_2$, Sn-Doped $In_2O_3$ and Ce-Doped $TiO_2$ Films as Transparent Counter Electrodes for Electrochromic Window

  • 김영일;윤주병;최진호;Guy Campet;Didier Camino;Josik Portier;Jean Salardenne
    • Bulletin of the Korean Chemical Society
    • /
    • 제19권1호
    • /
    • pp.107-109
    • /
    • 1998
  • The $SnO_2$, Sn-doped $In_2O+3\; and \;Ce-doped\; TiO_2$ films have been prepared by RF sputtering method, and their opto-electrochemical properties were investigated in view of the applicability as counter electrodes in the electrochromic window system. These oxide films could reversibly intercalate $Li^+$ ions owing to the nanocrystalline texture, but remained colorless and transparent. The high transmittance of the lithiated films could be attributed to the prevalence of the $Sn^{4+}/Sn^{2+}\; and\; Ce^{4+}/Ce^{3+}$ redox couples having 5s and 6s character conduction bands, respectively. For the Ce-doped $TiO_2$ film, $(TiO_2)_{1-x}(CeO_2)_x$, an optimized electrochemical reversibility was found in the film with the composition of x = 0.1.

고효율 로이유리 창호의 정량적 단열성능 평가 (An Evaluation for the Quantitative Thermal Performance of High Energy Efficiency Low-e Window)

  • 최경석;최현중;강재식;양관섭;이숭언
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.970-975
    • /
    • 2006
  • In the high oil prices age, intensification of energy efficiency promotion in the building sector is required. Windows are dominating large percentage whole building loads, and are regarding as the primary target of energy efficiency. The purpose of this study is to draw up a technical counterplan for the intensification of windows energy efficiency and spread promotion by quantitative thermal performance with KS test method for a comparison between the general Pair glass windows and the Low-e pair glass windows.

  • PDF

가변 투과시스템의 광제어 특성을 고려한 통합 채광시스템의 적용성 평가에 관한 연구 (A Design and Performance Evaluation of Differentiated Daylight-Glazing Systems)

  • 김곤;김정태
    • 조명전기설비학회논문지
    • /
    • 제19권2호
    • /
    • pp.13-22
    • /
    • 2005
  • 채광과 직사광 제어라는 자연조명의 상반된 목적을 동시에 충족시키기 위하여 본 연구에서 기존의 유리 창호를 용도와 기능에 따라 채광창과 조망창의 두 부분으로 분리한 이중분할창호시스템이 설계되었다. 채광량을 극대화하기 위하여 고창부의 채광창은 투명유리를 사용하며 조망창은 제어를 위한 다양한 기능성 유리를 적용하였다. 부가적으로 물리적 광제어 및 조절장치인 광선반, 수평 및 수직형 블라인드가 내장된 일체형 이중분할창호를 포함한 포괄적인 광제어 기법의 양적$\cdot$질적 조명효과를 통합적으로 평가하여, 제안된 창호시스템의 적용성을 평가하였다. 조망창과 채광고창의 경계부에 수평형 광선반을 설치하면 일차적인 직사광 유입으로 인하여 극심하게 높은 조도를 나타내는 창면 관접부의 조도를 완화시키는 차폐효과와 아울러 광선반의 반사 능력으로 인하여 채광성능면에서 불리한 실내측 후면부의 조도를 증가시키는데 현격한 효과를 2차적으로 기대할 수 있다. 실내바닥 수평면의 평균조도는 차광기능에 의하여 균제도가 2배 이상 향상되며 수평 슬릿의 반사에 의하여 $16(\%)$ 이상 증가하는 효과가 있으며 태양고도가 낮고 방위각이 정남향이 아닌 경우 수직 차광재를 사용하면 광제어 기능으로 인한 균제도의 향상과 $10(\%)$이상의 후면부 조도의 증가 및 조망이 확보되는 상대적인 장점이 있다.

축소모형을 이용한 분할형 유리 투과체 창호시스템의 채광성능실험 (Scale Model Experiment on Daylighting of Differentiated Glazing System)

  • 정인영;김정태
    • KIEAE Journal
    • /
    • 제4권4호
    • /
    • pp.61-68
    • /
    • 2004
  • Daylight is a critical factor in architecture, as it helps enhance the working efficiency and pleasantness of the people working inside, in addition to reduce the power consumption in heating and cooling and make the interior space brighter. There are many kinds of glazing and daylighting systems. At present, research and efforts for their development are carried out, alongside quantitative evaluation. This study aims to present basic materials to be used to design proper glazing and daylighting systems in architecture based on a quantitative evaluation by scale models of existing office buildings. The result of the study can be summarized as follows. 1)As a result of the experiment, it appeared that the ratio of the interior illumination (i.e. at the working table, ceiling and wall) against the outdoor illumination increases at a constant rate, as the transmittance of the glazing goes up. 2) It was found that the SIR(Sunlight Illuminance Ratio) of a separated window system goes up by 20-50% at the rear part than in the case of an ordinary window system.

공동주택의 배치유형에 따른 창호 시스템의 채광특성 (Daylighting Performance of Refurbished Window System based on Site Plans in Recently-Planned Apartment Houses)

  • 김곤;노지웅
    • KIEAE Journal
    • /
    • 제8권1호
    • /
    • pp.37-44
    • /
    • 2008
  • Though they have advantages in terms of aesthetic in modern architecture, however, rectangular-shaped towers causes being short of natural light due to deep interior space. There are compromised attempts to take advantages of each building shape selectively. As a result, we now witness the advent of Y-shaped, T-shaped, V-shaped and ㅈ-shaped buildings on the market. The mutative type of apartment houses usually faces southwest or southeast, which has lot of daylighting availability but anyhow, the proportion of the apartment houses which have a full south aspect. The need to verify the potential of daylighting in new building-block shapes exists. At the same time, the expansion of balcony area was legalized and thus, a visual buffer area does not exist any more. All-glass window wall on apartment houses without a balcony produces pretty harmful area with direct sunbeam. Recently, the refurbished version of conventional windows has been developed for the purposed of minimizing energy loss occurred around windows. This research initialized a series of research to deal with almost all on window wall for apartment houses. First of all, huge amount of already-designed examples of apartment houses have been analyzed in terms of floor plan, elevation, orientation and glazing materials.

초등학교 채광 성능 실태조사에 따른 건축계획적 개선방안에 관한 연구 (Architectural Implementation for the Daylight-Performance in the Elementary School)

  • 이정철;임홍수;김곤;구재오
    • KIEAE Journal
    • /
    • 제10권3호
    • /
    • pp.43-50
    • /
    • 2010
  • Natural lighting is directly connected with our mental and physical health. For working or learning effect, the proper natural lighting is required for improving our living conditions. School facilities, especially, are the place where includes students' ordinary activities with learning behaviors during the school years from elementary to high school. This study was carried out for the purpose introducing a basic database in that planning a school by researching on the actual in the natural lighting system of some schools' classroom, estimating, and analyzing through a simulation, which resulted in a method of improving the natural lighting system. As a result of measuring and analyzing Daylight Factor(DF) during the time from 9 am to 3 pm when students are activating in their classroom, generally DF range of the sides near to window and aisle seats zone are not distributed well. Besides, two out of four school which are researched would not reach the standards of the law for school sanitary while rest of the schools meet the standards; Average DF 5% and Minimum DF 2%. And the result of a simulation by RADIANCE program shows the most appropriate DF range when it is applied in variable numbers about an oriehows the- South-east 15, south-east 30, south-east 45, south-west 15, south-west 30, and south-west 45 degrees. When it is applied in the variable numbers about glass transmittance - 60%, 70%, and 80% in condition facing south of a classroom, the result shows that the DF range of 80% transmittance is relatively higher than other glasses in the classroom. Thus, when a school is built, plans for an orientation is necessary for improve of elementary schools' environment with the glass installation which is made for high transmittance and is regarded with the students' activities time.

금속유기화학증착법으로 사파이어 기판에 증착된 단층 SiO2, TiO2 저반사막의 광 투과율, 내열성, 기계적 특성에 관한 연구 (A Study on the Transmittance, Heat-Resistance, and Mechanical Properties of SiO2, TiO2 Anti-Reflective Single Layers Deposited on Sapphire Substrate by MOCVD)

  • 심규인;엄형우;강형;최세영
    • 한국군사과학기술학회지
    • /
    • 제17권5호
    • /
    • pp.672-679
    • /
    • 2014
  • To improve sensing capability of infrared, heat-resistance and mechanical properties, the $SiO_2$ and $TiO_2$ anti-reflective layers were coated on sapphire substrate by MOCVD. The standard wavelength was 4,600nm, and the thickness of anti-reflective layers were 379 and 758nm in case of ${\lambda}/4$ and ${\lambda}/2$ of incident angle($65^{\circ}$), respectively. The $SiO_2$ and $TiO_2$ anti-reflective layers were coated 12.6 and 9.7nm/min of deposition rates by increasing oxygen pressure to set the ideal refractive index of 1.283. In case of $SiO_2({\lambda}/2)$ coating, the transmittance increased from 55.0 to 62.7%. The transmittance of $TiO_2({\lambda}/2)$ anti-reflective layer also increased from 55.0 to 64.8%. The flexural strength of $SiO_2({\lambda}/2)$ and $TiO_2({\lambda}/2)$ layer coated sapphire increased from 337.8 to 362.9 and 371.8MPa, respectively. The flexural strength at $500^{\circ}C$ of these materials also increased respectively to 304.5, 358.2MPa from 265.9MPa. From these results, we confirmed these materials can be used as transmission window of infrared light.

위상지연 필름을 이용한 가시광 투과율 가변형 스마트윈도우 제작 (Fabrication of Visible Light Transmittance-variable Smart Windows Using Phase Retardation Films)

  • 김일구;양호창;박영민;홍영규;이승현
    • 마이크로전자및패키징학회지
    • /
    • 제29권4호
    • /
    • pp.29-34
    • /
    • 2022
  • 위상지연 필름을 이용하여 가시광선 투과도 제어가 가능한 스마트윈도우 제작 기술을 제안한다. 위상지연 필름의 phase retardation(𝚪)이 𝛑/2(𝚫n·d = 𝛌/4)인 경우 선편광을 원편광으로 변환시켜줄 수 있으며, 서로 다른 배향각도를 갖는 두 장의 𝛌/4 위상지연 필름을 이용하여 광투과 모드(45°/-45°)와 광차단 모드(45°/45°) 제어가 가능한 스마트윈도우를 제작할 수 있다. 본 연구에서는 복굴절 물질인 reactive mesogen (RM)의 두께에 따른 retardation 특성(𝚫n·d)을 평가함으로써 𝚫n·d가 𝛌/4인 위상지연 필름을 제작하였다. 서로 다른 𝚫n·d 값을 갖는 위상지연 필름이 적용된 스마트윈도우의 광차단 특성을 평가한 결과, 𝛌/4 위상지연 필름 기반의 스마트윈도우에서 가장 높은 광차단율(≥20%)을 보였다. 이를 통해 𝚫n·d의 값이 𝛌/4 일 때 위상지연 효과가 가장 높다는 것을 확인하였으며, 𝛌/4 위상지연 필름을 적용하여 150×150 mm2 크기의 스마트윈도우를 구현하였다.

창호의 광학적 특성에 따른 ZeSH의 일사취득 및 난방부하에 관한 민감도 분석 (A Sensitivity Analysis about Solar Heat Gain and Heating Load of ZeSH According to Optical Characteristics of Window system)

  • 손선우;백남춘;서승직
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 춘계학술발표대회 논문집
    • /
    • pp.66-71
    • /
    • 2009
  • To reduce the building energy consumption, the major advanced nations are conducting actively many researches on so called a "self-sufficient building(or other words zero energy building)" which can support its required energy by itself. Given this background, KIER(Korea Institute of Energy Research) built full size test-bed of the zero energy solar house in early 2002, and has studied on the self-sufficient heating load up to now. We analyse the sensitivity between the heating load and the solar radiation gain according to the change the effective transmittance of windows. The authors classified 9 cases by solar transmittance of glass. The results demonstrate the solar radiation amount is 0.466 MWh from the eastern zone of Fl.,1(the first floor), 0.332 MWh from Fl.,2(the second floor), 1.194 MWh form the southern zone of F1., and 0.822 MWh from the southern zone of Fl.,2 on the case 1(each cases are classified by window types). On the case 9, the solar radiation amount is 3.127 MWh, 2.662 MWh, 8.799 MWh and 6.078 MWh from the same condition. For the Fl.,1, the amount of Heat Load that is saved per year ranged 10.5 to 48 %, and the reduction was anywhere from 0.2 to 17.9% for Fl.,2

  • PDF

첨단채광시스템 실험용 Mock-Up 모형의 형상 및 모니터링 프로토콜 시스템에 관한 비교분석 - IEA SHC Task21을 중심으로- (Comparative Analysis on the Mock-ups' Configuration and Monitoring Protocol System of Advanced Daylighting Systems for Daylighting Experiment - Focused on IEA SHC Task21-)

  • 정인영;최상현;김정태
    • KIEAE Journal
    • /
    • 제4권1호
    • /
    • pp.11-20
    • /
    • 2004
  • Innovative daylighting systems in buildings in various climatic zones around the world have been developed under the IEA SHC Task21. The performance assessment were obtained by monitoring the most systems using full-scale test model rooms or actual buildings under real sky conditions. This study aims to analyze the configuration and monitoring system of the nine Mock-up models of the IEA SHC Task21 comparatively. For the purpose, the geometry of the test rooms (length, width, height, window area, glazed area and occupied), reflectance of walls, floor and ceiling, transmittance of glazing (transmittance for hemispherical irradiation, normal irradiation and U-value) were compared. And equipment for measurement (manufacturer, range, calibration, maximum calibration error, cosine response error, fatigue error), and data acquisition system (manufacturer, type, number of differential analogue input channels, A/D converter resolution in bits, data acquisition software) were also analyzed comparatively. Some findings of these experimental methodology of standard monitoring have been proven to be a valuable one for future assessment of advanced daylighting systems in our country.