• 제목/요약/키워드: Window ratio

검색결과 402건 처리시간 0.028초

거주자 가구배치 선호경향을 고려한 실 유형별 붙박이장 위치선정 (Determination of closet position by room style based on movable furniture layout preference of residents)

  • 진경일
    • 한국실내디자인학회논문집
    • /
    • 제40호
    • /
    • pp.86-93
    • /
    • 2003
  • Korean traditionally prefer a house with a southern exposure to other styles. Moreover, pretty part of dwelling style in Korea is apartment building. But generally, there are much more north oriented rooms than opposite one in apartment. Generally, most Korean tends to consider the direction of the room as an important factor to decide the arrangement of their furniture. Also, the location of window, door, bed, and closet can affect on the decision-making process of furniture layout. So, the closet position should be determined by not only window direction and door position, but also the furniture arrangement preference of residents. After considering the window and door position, there are 16 alternatives in a room. (Multiplied 4 window directions by 4 door positions under the assumption that the window and the door cannot be on the same side of the wall.) Also, this study analyzed each room style ratio considering the symmetry of each plan by comparing the apartment building plan. This paper studied the bedroom style by analyzing the 180 apartment building plans and survey of furniture layout; the furniture in this study represents bed and desk those are mainly laid in Korean bedroom. Finally, this paper suggested the methodology to find optimal alternatives of furniture and closet layout for high-rise apartment residents, based on the door and window position, and the furniture layout preference of residents.

차폐계수와 창면적비에 따른 공동주택의 건물에너지효율등급 평가 (The Building Energy Efficiency Rating Evaluation of Apartment depending on SC and Window area ratio)

  • 장철용;한혜심;이진숙
    • 한국태양에너지학회 논문집
    • /
    • 제30권5호
    • /
    • pp.38-43
    • /
    • 2010
  • Enhancement of exterior's insulation performance like wall or window etc. is general way for building's energy efficient and thermal performance. But exterior's opening plan is important for minimizing the energy consumption and heat loss. In this paper, energy saving rate will be analyzed and compared considering the window area's rate and window's SC(Shading Coefficient) in a apartment with Building Energy Efficiency Rating System's evaluation tool. In the process of evaluation, energy saving rate is measured at each stage of the window area's rate from 20% to 60% every 10% term and the shading coefficient value from 1.0 to 0.6. As a result of this research, energy saving evaluation could not be measured exactly with existing evaluation tool. Accord this research, Building Energy Rating System's evaluation range is needed to be broaden for exact evaluation of energy saving rate.

Drilling Fluid를 적용한 시추공의 안정성에 대한 수치해석 (Numerical Analysis of Borehole Stability Depending on Drilling Fluid)

  • 신춘원;유충식
    • 한국지반신소재학회논문집
    • /
    • 제16권2호
    • /
    • pp.183-194
    • /
    • 2017
  • 지반을 굴착하여 시추공을 형성할 때 공벽을 중심으로 응력의 재분배가 이루어지고 이 때 시추 안정액을 활용하여 공벽에 응력의 평형을 이룸으로써 공벽의 안정성을 유지한다. 시추공 내에 주입하는 시추 안정액이 시추공의 안정성을 유지하기 위한 압력의 상한과 하한의 범위를 Mud window라고 정의하고 다양한 이론에 의해 계산된다. 본 연구에서는 수치해석을 활용하여 시추공의 안정성을 분석하여 Mud window를 작성하고 이론값과 비교 분석하여 모델링에 대한 검증을 수행하였다.

국내 공동주택의 개구부형태 및 발코니 유·무에 따른 분출화염 성상에 관한 연구 (A Study on the Characterization of Fire Plume Ejected from an Opening according to the Opening Form and the Balcony of Apartment in Korea)

  • 이규민;구태윤;황의청;권영진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2017년도 춘계 학술논문 발표대회
    • /
    • pp.37-38
    • /
    • 2017
  • This study identified the effects of flame on the upper by fire plume ejected. we implemented model experiment according to investigation of housing area effect, window aspect ratio and balcony availability. we confirmed that opening ratio was increased according to housing area larger. the square window confirmed that is progressing fire plume ejected of free space. According to the value of an opening aspect ratio 'n' getting higher, the horizontal widow is getting that increased the risk as the fire spread an external to the top of opening. it is determined to the fundamental solution about fire safety in the extended balcony of apartment.

  • PDF

Sample selection approach using moving window for acoustic analysis of pathological sustained vowels according to signal typing

  • 이지연
    • 말소리와 음성과학
    • /
    • 제3권3호
    • /
    • pp.99-108
    • /
    • 2011
  • The perturbation parameters like jitter, shimmer, and signal-to-noise ratio (SNR) are largely estimated in the particular segment from the subjective or whole portion of the given pathological voice signal although there are many possible regions to be able to analyze the voice signals. In this paper, the pathological voice signals were classified as type 1, 2, 3, or 4 according to narrow band spectrogram and the value differences of the perturbation parameters extracted in the subjective and entire portion tended to be getting bigger as from type 1 to type 4 signals. Therefore, sample selection method based on moving window to analyze type 2 and 3 signals as well as type 1 signals is proposed. Although type 3 signals cannot be analyzed using the perturbation analysis, the type 3 signals by selecting out the samples in which error count is less than 10 through moving window were analyzed. At present, there is no method to be able to analyze the type 4 signals. Future research will endeavor to determine the best way to evaluate such voices.

  • PDF

실내조명환경의 시각적 쾌적성 확보 및 조명부하 저감을 위한 채광제어방법에 관한 연구 (A Study on Daylight Control Method for Securing Visual Comfort and Reducing Lighting Loads on Interior Lighting Environment)

  • 한상필
    • 한국태양에너지학회 논문집
    • /
    • 제32권6호
    • /
    • pp.100-105
    • /
    • 2012
  • In previous study, to investigate the impression of the compound lighting based on the AC-Model at the full-size room, the impressions of various compound lighting were completed as compared with that of the uniform lightings through the comparison method (a paired comparison) by Semantic Differential scaling. Also, we examined the effect of the supplementary lighting type increasing the lights at the side of the window and the blind-control lighting type, and they were compared with the existing compound lighting type. In results, pared comparison of the compound lighting and the uniform lighting, indicates that the impression of the compound lighting is generally similar to that of the uniform lighting when there are same ratios of the light from the window. Based on these results, we suggest that the AC-Model might be applied to various conditions. And we also introduce the method for daylighting that it is possible to reduce discomfort glare and to improve visual impressions as the supplementary type and blind-control type on the compound lighting. And it was found that electric power consumption of the compound lighting room was lower than that of the uniform lighting room when as same lighting ratio of the compound lighting and the uniform lighting from the window was provided or there was the lighting distribution simulated to same light ratio from the window. Since the method of the ACModel was described in the experimental condition, additional studies should be performed to determine if this model could be applied to different window configurations, lighting layout and types of a room.

창호를 통한 열전달 현상에 관한 연구 (A Study on the Heat Transfer Phenomenon through the Glazing System)

  • 강은율;오명원;김병선
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 추계학술발표대회 논문집
    • /
    • pp.32-37
    • /
    • 2009
  • An energy loss through the window system occupies about 10 to 30 percent on energy consumption of the whole building. That is the reason, several elements for a building composition of window system are the weakest from the heat. Insulation performance increases for the reducing heat loss. Heat transfer through the window system that is reducing heat transfer through conduction, convection and radiation. Insulation performance reinforcement methods classify improving heat specific quality of window system and improving efficiency of whole window system. The most application method among each methods is reducing emission ratio of the window system(Low-E glass), increasing a number of glazing(multiple window) and a method of vacuuming between glazing and glazing. Therefore this study is investigated a sort of glazing and specific character, U-value calculation with changing glazing thickness and calculation of temperature distribution and U-value with a glazing charging gas kind from double glazing. For a conclusion, an aspect of U-value figure at the smallest value case of vacuum glazing with Low-E coating. That means insulation efficiency is the best advantage during a building plan selecting vacuum glazing with Low-E coating for a energy saving aspect. In this way, U-value become different the number of glazing, coating whether or not and selecting injection gas. Therefore selecting of glazing is very important after due consideration by a characteristic and use of building and consideration of strong point and weak point.

  • PDF

지수창함수를 사용한 임팩트햄머 실험에서 주파수응답함수의 왜곡과 개선책 (FRF Distortion Caused by Exponential Window Function on Impact Hammer Testing and Its Solution)

  • 안세진;정의봉
    • 한국소음진동공학회논문집
    • /
    • 제13권5호
    • /
    • pp.334-340
    • /
    • 2003
  • Exponential window function Is widely used In impact hammer testing to reduce leakage error as well as to get a good S/N ratio. The larger its decaying rate is, the more effectively the leakage errors are reduced. But if the decay rate of the exponential window is too large, the FRF is distorted. And the modal parameters of the system can not be exactly identified by modal analysis technique. Therefore, it is a difficult problem to determine proper decay rate in impact hammer testing. In this paper, amount of the FRF distortion caused by exponential window is theoretically uncovered. A new circle fitting method is also proposed so that the modal parameters are directly extracted from impulse response spectrum distorted by the exponential-windowed impulse response data. The results by the conventional and proposed circle fitting method are compared through a numerical example.

창호통합형 배열회수 환기시스템의 열성능 및 경제성 평가 (An Analysis on Thermal Performance and Economic of Heat Recovery Ventilation System Integrated with Window)

  • 성욱주;조수;송규동
    • 설비공학논문집
    • /
    • 제24권8호
    • /
    • pp.646-655
    • /
    • 2012
  • This study is intended to analyze the thermal performance and evaluate the applicability about non-duct type heat recovery ventilation system integrated with window. Eventually, economic analysis of the system is conducted according to building energy saving ratio of it. As results of the thermal performance, the U-factor of the window conducted on the basis of KS F 2278 appears to $1.8W/m^2K$, and the effective heat exchange efficiency of the ventilator conducted on the basis of KS B 6879 appears 49.95% for cooling, 66.89% for heating. In the applicability evaluated by TRNSYS 16, the caes of applying the heat recovery ventilator integrated with window is found to reduce the cooling or heating load by 2.9% or 13.5% than the non-ventilator case. The results of economic analysis taking a side of consumer is verified as the payback is 3 years, and the accumulated earning is 1,408,133 won in terms of '600,000 won/unit' for initial cost, 10 years for useful life of the system.

Optimizing the maximum reported cluster size for normal-based spatial scan statistics

  • Yoo, Haerin;Jung, Inkyung
    • Communications for Statistical Applications and Methods
    • /
    • 제25권4호
    • /
    • pp.373-383
    • /
    • 2018
  • The spatial scan statistic is a widely used method to detect spatial clusters. The method imposes a large number of scanning windows with pre-defined shapes and varying sizes on the entire study region. The likelihood ratio test statistic comparing inside versus outside each window is then calculated and the window with the maximum value of test statistic becomes the most likely cluster. The results of cluster detection respond sensitively to the shape and the maximum size of scanning windows. The shape of scanning window has been extensively studied; however, there has been relatively little attention on the maximum scanning window size (MSWS) or maximum reported cluster size (MRCS). The Gini coefficient has recently been proposed by Han et al. (International Journal of Health Geographics, 15, 27, 2016) as a powerful tool to determine the optimal value of MRCS for the Poisson-based spatial scan statistic. In this paper, we apply the Gini coefficient to normal-based spatial scan statistics. Through a simulation study, we evaluate the performance of the proposed method. We illustrate the method using a real data example of female colorectal cancer incidence rates in South Korea for the year 2009.