• 제목/요약/키워드: Window installation

검색결과 130건 처리시간 0.02초

Improvement of the PVC Window Frame Installation Method Integrated with Gangform and Field Applicability Analysis

  • Choi, Hyo-Sung;Lee, Jeong-Ho;Yoo, Huyn-Seok;Kim, Young-Suk;Han, Seung-Woo
    • 한국건축시공학회지
    • /
    • 제11권5호
    • /
    • pp.482-500
    • /
    • 2011
  • In apartment housing construction, window frame installation work, which is conducted after the structural framework, is very important, because its completion time directly affects the starting time of successive interior finishing works, as well as the overall construction period. Construction delays in interior finishing works might occur due to problems inherent to the conventional window frame installation method, such as the poor verticality of window frames, and the water leakage around them. The primary objective of this study is to analyze the problems of a 'Gangform integrated PVC window frame pre-installation method' based on its pilot test results. Next, this study proposes an improved conceptual model that enables the end users to enhance the field applicability of this method in terms of productivity, time, and cost. The field applicability of the proposed 'Gangform integrated PVC window frame pre-installation method' was also verified through a survey.

창호 시공용 폴리우레탄 및 실리콘 실란트 접착성 및 상응성 평가 (The evaluation for adhesion and compatibility properties of polyurethane and silicone sealant for window installation)

  • 안명수;정진영;서연원;김성현;배기선
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2014년도 추계 학술논문 발표대회
    • /
    • pp.75-77
    • /
    • 2014
  • Using sealant for window installation is sealing the gap between the window frame and outer wall (such as concrete). A sealant serves to prevent external environmental impacts such as moisture, rain, sand, and dust entering inside of the building and make the building durable. In order to fulfill basic jointing function of sealing, at least 6 mm joint gap between two bonding surfaces are required. Also, adhesion performance between sealant and surfaces and the compatibility with other building materials are required to check before installation. In general, 2 part polyurethane sealant and 1 part silicone sealant are most common materials for sealing the joint of window. In this study, adhesion performances of those two generic sealants reflecting actual application conditions and the compatibility evaluations with other building materials are conducted to propose proper window installation procedures.

  • PDF

Thermal Performance Evaluation of Junction Thermal Bridge according to Installation Position of Window

  • Lee, Soo-Man;Kim, Dong-Yun;Ahn, Jung-Hyuk;Eom, Jae-Yong;Shin, U-Cheul
    • KIEAE Journal
    • /
    • 제17권3호
    • /
    • pp.15-21
    • /
    • 2017
  • Purpose: "Building energy design standard" is used to limit the thermal transmittance of building in Korea. However, it only covers the insulation standard for each appropriate elements of a building, not the thermal performance of Junction thermal bridge of windows and doors installed in wall. Therefore in this study, we have evaluated the thermal performance of Junction thermal bridge depending on installation method and position of windows and provide it as design data. Method: We analyzed heat transfer of 4-Track sliding window and tilt & turn triple glazed window that are placed in the first class category on window energy efficiency rating using Window 7.4 and Therm 7.4. Result : First, linear thermal transmittance of 4-Track sliding window differs by 2.2 times or more depending of installation method and location. It is higher than the linear thermal transmittance, 0.01W/mK, proposed by Passivhaus. Second, linear thermal transmittance of Tilt & turn triple glazed window differs by 7.7 times or more depending of installation method and location. The average linear thermal transmittance was less than 0.01W /mK when windows were installed on the internal wall insulation by the fixed hardware attachment method. Third, the thermal losses of a window caused by a junction thermal bridge are inversely proportional to the window area and converge gradually as the area increased.

외단열 벽체에서 창호 설치 위치에 따른 단열성능 및 냉난방 에너지 소비량 (Insulation Performance and Heating and Cooling Energy Consumption depending on the Window Reveal Depth in External Wall Insulation)

  • 이규남;정근주
    • 대한건축학회논문집:구조계
    • /
    • 제33권12호
    • /
    • pp.91-98
    • /
    • 2017
  • In this study, the effect of window installation position in the residential building with the external insulation was numerically investigated in terms of insulation performance and heating/cooling energy consumption. For different window positions, 2-D heat transfer simulation was conducted to deduce the linear thermal transmittance, which was inputted to the dynamic energy simulation in order to analyze heating/cooling energy consumption. Simulation results showed that the linear thermal transmittance ranges from 0.05 W/mK to 0.7 W/mK, and is reduced as the window is installed near the external finish line. Indoor surface temperature and TDR analysis showed that the condensation risk is the lowest when the window is installed at the middle of the insulation and wall structure. It was also found that the window installation near the external finish can reduce the annual heating/cooling energy consumption by 12~16%, compared with the window installation near the interior finish. Although the window installation near the external finish can achieve the lowest heating/cooling energy consumption, it might lead to increased condensation risks unless additional insulation is applied. Thus, it can be concluded that the window should be installed near the insulation-wall structure junction, in consideration of the overall performance including energy consumption, condensation prevention and constructability.

움직이는 창과 이중 초점 렌즈를 이용한 프랙탈-공간 다중화 기법 (A Novel Fractal-Space Multiplexing using Moving Window and Double-Focusing Lens)

  • 김수길
    • 조명전기설비학회논문지
    • /
    • 제16권6호
    • /
    • pp.1-6
    • /
    • 2002
  • 움직이는 창과 이중 초점 렌즈를 이용한 프랙탈-공간 다중화 기법의 홀로그래픽 메모리 시스템을 제안하였다. 이 시스템은 기존의 움직이는 창을 이용한 홀로그래픽 메모리 시스템의, 수직 방향으로 인접한 움직이는 창의 열에 의한 누화를 제거할 수 있으며, 이를 광학적 실험을 통해 그 가능성을 입증하였다.

스마트 윈도우 설치 속성에 따른 사무공간의 주광 환경 추이 (Trends of Daylight Environment for Office Spaces Based on Smart-Window Installation Settings)

  • 김재향;한승훈
    • 신재생에너지
    • /
    • 제19권3호
    • /
    • pp.13-21
    • /
    • 2023
  • Smart windows are capable of varying their visible light transmittance (VLT) in response to changing environmental conditions. The VLT variability of architectural windows is highly valuable because it enables indoor lighting and energy environments to align with external changes. However, challenges such as high installation costs and assurance of glass visibility have prompted the exploration of alternative solutions, including models incorporating partially applied smart windows., Prior research focused on useful daylight illuminance (UDI) analysis for south-facing office buildings, pointing out suitable areas for smart-window implementation to enhance lighting control. In this study, we broadened this scope by determining optimal smart-window application zones under changing building orientation. Furthermore, we studied the correlation between building orientation and smart-window deployment areas.

측방접근법을 이용한 상악동거상술 후 임프란트 식립에 대한 후향적 평가 (A RETROSPECTIVE EVALUATION OF IMPLANT INSTALLATION WITH MAXILLARY SINUS AUGMENTATION BY LATERAL WINDOW TECHNIQUE)

  • 기세일;유민기;김영준;국민석;박홍주;;오희균
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제30권5호
    • /
    • pp.457-464
    • /
    • 2008
  • Purpose: The aim of this study was to evaluate the clinical results of implants which were installed with maxillary sinus elevation by using lateral window technique. Materials and methods: We performed the maxillary sinus elevation by lateral window technique to 87 patients who visited Dept. of Oral & Maxillofacial Surgery, Chonnam National University Hospital from January, 2003 to January, 2007. When the residual bone height was from 3 mm to 7 mm, the sinus elevation and simultaneous implant installation was mostly performed. When the residual bone height was less than 3 mm, the sinus elevation was performed and the delayed implant installation was done after 5 or 6 months. No artificial membranes were used for coverage of the lateral bony window site and freeze dried fibrin sealant was applied to the grafted bone. The mean follow-up period was 28.5 months (ranged from 10 months to 48 months) Results: 1. Unilateral sinus elevations were performed in 51 patients and bilateral sinus elevations were performed in 36 patients. And the total number of sinus elevation procedure was 123 cases. 2. The sinus elevation and simultaneous implant installation was performed in 89 sinuses and 249 implants were installed. The sinus elevation and delayed implant installation was performed in 44 sinuses and 141 implants were installed. The total number of implants were 390 in 133 sinuses. The average healing period after sinus elevations was 6.1 months in delayed implant installation. 3. Only autogenous bone, autogenous bone mixing with allografts or autogenous bone mixing with xenografts were used as graft materials. 4. The average period from first surgery to second surgery was about 7.2 months. 5. Some patients complications, such as perforation of sinus membrane, swelling, infection and exposure of cover screw. Two implants were removed in the infected sinus. 6. The survival rate of implants with maxillary sinus elevation by lateral window technique was 99.5% and the success rate of implants was 95.1%. Conclusions: These results indicated that the implants which were installed with maxillary sinus elevation by lateral window technique showed high survival and success rates.

투과일사의 유입길이에 따른 Tilt 창호의 적정 기울기 산정 (The Calculation on the Optimum Angle of Tilt Type Window by Length of Transmitted Solar Radiation)

  • 조성우
    • 설비공학논문집
    • /
    • 제22권9호
    • /
    • pp.635-640
    • /
    • 2010
  • This study is suggested tilt window type to be restrained solar radiation through vertical window type in buildings. The shading and aesthetical effect of buildings would be solved by installation of tilt window type. For investigate optimum an angle of tilt window and building azimuth in reference region, the distance of transmitted solar radiation is calculated. The results of calculation showed optimum an angle of tilt window is obtained $7^{\circ}$ that the distance of transmitted solar radiation is 20% of 1.5m of balcony width. In case of an tilt window angle of $7^{\circ}$, the optimum building azimuth is showed $SW15^{\circ}{\sim}SE15$.

색채와 광원이 쇼윈도 전시효과에 미치는 영향 (A Experimental Study on the Influence of the Display Effect by Color and Light Source in Show Window)

  • 이정옥;김현지
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제9권4호
    • /
    • pp.49-54
    • /
    • 1995
  • This paper is an experimental study on the influence of the demonstration effect by color and light source in show window. This experiment used semantic differentical method in model show window of actual size. The important outcomes of this study are summarized below. 1. In the result by factor analysis, three factors are classified. They are diversity, emotion, lightness. 2. In the study on the influence by light source, incandescence lamp is the most effective light source in every items. 3. In the result of the study on the influence by color source, according to each factor bring out following result ; Green is the most effective in diversity factor and ligthness factor. Yellow is the most effective in emotion factor.

  • PDF

창호 유리의 단열필름 시공에 따른 생애주기비용 비교 분석 (A Comparative Analysis of Life Cycle Cost on the Window Glass and the Insulation Film Coated Glass for Window)

  • 정민구;김광희
    • 한국건축시공학회지
    • /
    • 제14권6호
    • /
    • pp.583-590
    • /
    • 2014
  • 본 연구에서는 경제적인 창호공사 방안을 확인하기 위해 단열필름이 시공된 창호유리와 일반유리의 생애주기비용을 분석하여 비교하고자 하였다. 이를 위해 Window 6.3과 ECO2-OD 시뮬레이션 프로그램을 사용하여 유리 유형별 창호의 열성능 데이터를 측정하고 사례 건물에 적용하여 냉 난방 유지비용 및 LCC를 산출하여 경제성을 비교하였다. 연구결과 단열필름을 추가적으로 시공함으로써, 냉 난방 유지비용 측면에서는 하절기 태양열이 실내로 투과하는 것을 막아 냉방비용 절감 효과가 있지만, 이로 인해 동절기에는 난방비용이 증가하는 것으로 나타났다. 생애주기비용 측면에서 볼 때, 냉방비용 절감 효과가 난방비용 증가량과 필름 시공 및 수선으로 발생하는 추가비용을 상쇄하지 못하기 때문에 단열필름의 시공은 적절한 방법이 아니라고 할 수 있다.