DOI QR코드

DOI QR Code

A Comparative Analysis of Life Cycle Cost on the Window Glass and the Insulation Film Coated Glass for Window

창호 유리의 단열필름 시공에 따른 생애주기비용 비교 분석

  • Jeong, Mingu (Department of Architectural Engineering, Graduate School, Kyonggi University) ;
  • Kim, Gwang-Hee (Department of Plant·Architectural Engineering, Kyonggi University)
  • Received : 2014.06.30
  • Accepted : 2014.08.19
  • Published : 2014.12.20

Abstract

The purpose of this study is to analyze and compare the life cycle cost of window glass with insulation film and regular glass, to verify an economical window construction method. As an approach method, the thermal performance data of each type of glass was measured using Window 6.3 and ECO2-OD Simulation Program, applied it to the case building to calculate the air conditioning and heating maintenance costs and LCC, and compared the economic feasibility. As a result, installing an additional insulation film prevents the solar heat penetration in the summer, so it reduces the cooling cost, on the other hand, it increased heating cost in winter. From the life cycle cost perspective, the effect of cooling cost reduction does not counterbalance the increase in heating cost and the additional cost from film installation and repair; therefore, the installation of insulation film may not be a proper method.

본 연구에서는 경제적인 창호공사 방안을 확인하기 위해 단열필름이 시공된 창호유리와 일반유리의 생애주기비용을 분석하여 비교하고자 하였다. 이를 위해 Window 6.3과 ECO2-OD 시뮬레이션 프로그램을 사용하여 유리 유형별 창호의 열성능 데이터를 측정하고 사례 건물에 적용하여 냉 난방 유지비용 및 LCC를 산출하여 경제성을 비교하였다. 연구결과 단열필름을 추가적으로 시공함으로써, 냉 난방 유지비용 측면에서는 하절기 태양열이 실내로 투과하는 것을 막아 냉방비용 절감 효과가 있지만, 이로 인해 동절기에는 난방비용이 증가하는 것으로 나타났다. 생애주기비용 측면에서 볼 때, 냉방비용 절감 효과가 난방비용 증가량과 필름 시공 및 수선으로 발생하는 추가비용을 상쇄하지 못하기 때문에 단열필름의 시공은 적절한 방법이 아니라고 할 수 있다.

Keywords

References

  1. Jang CY, Ahn BL, Kim CH, Hong WH. A Study on the evaluation of airtightness and insulation performance of high airtight thermal window. Proceeding of the Fall Symposium of Korean Institute of Architectural Sustainable Environment and Building Systems; 2010 Oct 8; Seoul, Korea. Seoul (Korea): Korean Institute of Architectural Sustainable Environment and Building System; 2010. p. 133-6.
  2. Jang CH. [The technical status of window]. Journal of The Korean Society of Mechanical Engineers. 2010 Jul;50(7):47-50. Korean.
  3. Ahn BL, Kim CH, Jang CY, Leigh SB. An analysis study of thermal performance of temperable double low-e glass window. Journal of Architectural Institute of Korea. 2013 Feb;29(2):211-8.
  4. Schaefer C, Brauer G, Szczyrbowski J. Low emissivity coatings on architectural glass. Journal of Surface and Coatings Technology. 1997 Aug;93(1):37-45. https://doi.org/10.1016/S0257-8972(97)00034-0
  5. Kim SH, Kim SM, Kim HS, Jo MH, Kang SH, Yu SW, Cho YH. Thermal performance evaluation of the window film insulation. Proceeding of the Fall Symposium of the Regional Association of Architectural Institute of Korea; 2011 Oct 29; Gyeongsan, Korea. Seoul (Korea): The Regional Association of Architectural Institute of Korea; 2011. p. 45-8.
  6. Choe YJ, Jo JH. A study on thermal performance improvement of film coated glass. Proceeding of the Fall Symposium of Korean Institute of Architectural Sustainable Environment and Building Systems. 2012 Oct 20; Busan, Korea. Seoul (Korea): Korean Institute of Architectural Sustainable Environment and Building Systems; 2012. p. 201-4.
  7. Jelle BP, Hynd A, Gustavsen A, Dariush A, Goudey H, Hart R. Fenestration of today and tomorrow: a state-of-the-art review and future research opportunities. Journal of Solar Energy Materials & Solar Cells. 2012 Jan;96:1-28. https://doi.org/10.1016/j.solmat.2011.08.010
  8. Yoon JH, Park JS, Kim BS, Hong SC. A study on the insulation performance evaluation of triple glazing window system by u-value sensitivity analysis. Journal of Architectural Institute of Korea. 2007 Oct;23(10):159-66.
  9. Hwang IS, Lee YL. A study of adiabatic performance for vacuum glazing with design conditions. Journal of Korean Society of Manufacturing Technology Engineers. 2012 Aug;21(4):582-7. https://doi.org/10.7735/ksmte.2012.21.4.582
  10. Garrison J, Collins R. Manufacture and cost of vacuum glazing. Journal of Solar Energy. 1995 Sep;55(3):151-61. https://doi.org/10.1016/0038-092X(95)00046-T
  11. Manz H, Brunner S, Wullschleger L. Triple vacuum glazing: heat transfer and basic mechanical design constraints. Journal of Solar Energy. 2006 Dec;80(12):1632-42. https://doi.org/10.1016/j.solener.2005.11.003
  12. Appelfeld D, Hansen C, Svendsen S. Development of a slim window frame made of glass fibre reinforced polyester. Journal of Energy and Buildings. 2010 Oct;42(10):1918-25. https://doi.org/10.1016/j.enbuild.2010.05.028
  13. [Window design guidelines for saving building energy] [Internet]. Gwacheon (Korea): Ministry of Land. Transport and maritime affairs; 2012 Jul 26 [cited 2014 Oct 1]. Available from: http://www.mltm.go.kr/USR/NEWS/m_71/dtl.jsp?lcmspage=15&id=95070689.
  14. Nam JW, Won JS. Thermal performance evaluation of the window film insulation for building energy savings. Proceeding of the Fall Symposium of The Korean Solar Energy Society; 2008 Nov 14; Daejeon, Korea. Seoul (Korea): The Korean Solar Energy Society; 2008. p. 75-80.