• 제목/요약/키워드: Window Lift

검색결과 20건 처리시간 0.021초

자동차 Anti-trap Power Window Lift Controller 설계 (Design of Automotive Anti-trap Power Window Lift Controller)

  • 차민혁;김학련;이주
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.51-53
    • /
    • 2001
  • Permanent Magnet DC Motors are widely used in Automotive parts because they have cheap price, simple structure and high torque-speed ratio. But the motor in automotive parts is required high quality, complex function and lower price than before. This paper deals with design of controller for safety function that body trap on the automotive window. The algorithm of controller can adapt variety conditions with temperature, electrical, driving, etc.

  • PDF

차량 윈도우 리프트 음질 향상을 위한 음질 지수 제작 및 개선에의 응용 (The Development and Application of Sound Quality Index for the Improving Sound Quality to Road Vehicle Power Window System)

  • 김성현;박동철;조현호;성원찬;강연준
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2013년도 추계학술대회 논문집
    • /
    • pp.525-530
    • /
    • 2013
  • With the increasing the importance of emotional quality of vehicle, the sound quality of systems with electric motor components has become increasingly important. Electric motors are used for windows, seats, sun roof, mirrors, steering columns, windshield wiper, climate control blowers, etc. In this paper, a study was conducted to identify sound quality factors that contribute to customer's satisfaction and preference of the window lift system. Jury test for subjective evaluation was carried out and sound quality index was developed. Averaged sound pressure level and sharpness were significant factors when glass moves down. Also, maximum loudness at stop section and averaged loudness were significant factor when glass moves up. Noise source identification was carried out for the reduced the loudness and sharpness during glass transferred section and impulsive noise at stop section, Using the source identification result, several improvement points were applied. And finally, the degree of sound quality improvement was judged using sound quality index.

  • PDF

유한요소해석을 통한 자동차용 글라스의 승강성능 예측 (Prediction of Lift Performance of Automotive Glass Using Finite Element Analysis)

  • 문형일;김헌영;최천;이인혁;김도형
    • 대한기계학회논문집A
    • /
    • 제34권11호
    • /
    • pp.1749-1755
    • /
    • 2010
  • 파워 글라스 시스템의 특성은 주로 윈도우 레귤레이터의 거동 특성과 글라스 런에 의한 저항에 의해 결정되며, 시험 결과 분석을 통해 시스템의 성능을 예측한다. 본 논문에서는 시험적인 방법의 한계를 해결하기 위해, 익스플리시트 코드를 사용한 해석적 방법을 제안하였다. 해석 모델에 사용한 글라스 런은 무니-리블린 모델을 사용하여 모델링 하였고, 다양한 조건에서의 마찰 시험을 실시하여 마찰계수를 구하였다. 또한, 윈도우 레귤레이터 파트의 메커니즘은 패스트 벨트 시스템과 슬립 링요소를 사용하여 모델링 하였고, 상승 시 발생하는 전류와 하중과의 상관관계 분석을 통해 레귤레이션 메커니즘의 신뢰성을 검증하였고, 모터의 특성을 고려하여 신뢰성 있는 글라스 상승 시간을 예측하였다.

상악동 거상술을 동반한 임플란트 식립 시에 거상술 방법에 따른 임플란트 생존율의 비교 (Comparison of implant survival rate by sinus lifting technique in implantation with sinus lift)

  • 박광수;홍기석;정진형;임성빈
    • Journal of Periodontal and Implant Science
    • /
    • 제38권3호
    • /
    • pp.445-452
    • /
    • 2008
  • Purpose: The purpose of this study was comparison of survival rate of implant as two sinus elevation techniques and when window opening procedure had done it was comparison of survival rate of implant between the procedure of implantation after 6 month of sinus elevation to allow healing period and that of implantation with sinus elevation simultaneously. Material and Methods: All 79 of patients treated at DanKook University Dental Hospital Dept. of Periodontics for 164 implantation of maxillary posterior edentulous area with sinus elevation. Sinus elevation technique was divided of the technique : Osteotome technique and window opening technique. Result: 14 implants among 96 implants was failed implants of using osteotome for sinus elevation whereas one implant of 68 implants was failed of using window opening technique. Conclusion: Window opening technique had higher survival rate than osteotome technique. In case of window opening, there was no significant difference of immediate implantation and delayed implantation.

Clinical and biological analysis in graftless maxillary sinus lift

  • Parra, Marcelo;Olate, Sergio;Cantin, Mario
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제43권4호
    • /
    • pp.214-220
    • /
    • 2017
  • Maxillary sinus lift for dental implant installation is a well-known and versatile technique; new techniques are presented based on the physiology of intrasinus bone repair. The aim of this review was to determine the status of graftless maxillary sinus lift and analyze its foundations and results. A search was conducted of the literature between 1995 and 2015 in the Medline, ScienceDirect, and SciELO databases using the keywords "maxillary sinus lift," "blood clot," "graftless maxillary sinus augmentation," and "dental implant placement." Ten articles were selected for our analysis of this technique and its results. Despite the limited information, cases that were followed for at least six months and up to four years had a 90% success rate. Published techniques included a lateral window, elevation of the sinus membrane, drilling and dental implant installation, descent of the membrane with variations in the installation of the lateral wall access and suturing. The physiology behind this new bone formation response and the results of the present research were also discussed. We concluded that this is a promising and viable technique under certain inclusion criteria.

차량 윈도우 리프트 음질 고급감 향상을 위한 음질 지수 제작 및 개선에의 응용 (The Development and Application of Sound Quality Index for the Improving Luxury Sound Quality of Road Vehicle Power Window System)

  • 김성현;박동철;조현호;성원찬;강연준
    • 한국소음진동공학회논문집
    • /
    • 제24권2호
    • /
    • pp.108-116
    • /
    • 2014
  • With the increasing the importance of emotional quality of vehicle, the sound quality of systems with electric motor components has become increasingly important. Electric motors are used for windows, seats, sun roof, mirrors, steering columns, windshield wiper and climate control blowers, etc. In this paper, a study was conducted to identify sound quality factors that contribute to customer's satisfaction and preference of the window lift system. Jury test for subjective evaluation was carried out and sound quality index was developed. Averaged sound pressure level and sharpness were significant factors when glass moves down. Also, maximum loudness at stop section and averaged loudness were significant factor when glass moves up. Next, noise source identification was carried out using beam forming method during glass transferred section and impulsive noise at stop section. Several improvement methods were applied using the source identification result. And finally, the degree of sound quality improvement was judged using sound quality index.

잠금장치 작동에 따른 미서기 및 LS 창호 시스템의 기밀성 (Effect of Lock Operations on Airtightness of Sliding and LS Window Systems)

  • 박종준;윤유라;김영일;정광섭
    • 설비공학논문집
    • /
    • 제27권9호
    • /
    • pp.449-454
    • /
    • 2015
  • In this study, the effects of lock operations on the infiltration rates for the two window types sliding and lift sliding (LS) are investigated through experiment and simulation. The airtightness levels of the two window types-with locks both on and off-were measured according to the KS F 2292 Test method of airtightness that is used for windows and doors. The air-flow rates of both window types with the locks on for a pressure differential of 10 Pa are $1.98m^3/(m^2h)$ and $1.68m^3/(m^2h)$, respectively; with the locks off, the air-flow rates of the sliding and LS windows are $2.64m^3/(m^2h)$ and $5.83m^3/(m^2h)$, respectively, whereby the air-flow rates are 33% higher for sliding and 247% higher for LS. The air change per hour (ACH) was calculated using the ventilation-simulation software CONTAM. For the sliding window, the ACH changed from 0.45 to 0.57 when the lock was operated from on to off, representing an increase of 27%. For the LS window, the ACH changed from 0.29 to 0.81, showing an increase of 179%.

탄성표면파 소자를 이용한 대역통과 여파기의 설계에 관한 연구 (A study on the design of bandpass filters using SAW components)

  • 전계석;황금찬;김봉열
    • 전기의세계
    • /
    • 제31권2호
    • /
    • pp.141-146
    • /
    • 1982
  • In this paper, surface acoustic wave (SAW) bandpass filter is designed using the Fourier series approach and the I$_{0}$-shin window function. And also we studied a method to realize SAW filter using the apodized ID transducer which was fabricated with aluminum metallization of about 1500 A over .deg. thickness on Y-cut Z-propagating LiNbO$_{3}$, crystal by photolithographic technique (lift-off method). Experimental results on SAW bandpass filter responses show good agreements with the theoretical characteristics.s.

  • PDF

A radiographical study on the changes in height of grafting materials after sinus lift: a comparison between two types of xenogenic materials

  • Hieu, Pham-Duong;Chung, Jin-Hyung;Yim, Sung-Bin;Hong, Ki-Seok
    • Journal of Periodontal and Implant Science
    • /
    • 제40권1호
    • /
    • pp.25-32
    • /
    • 2010
  • Purpose: The performance of implant surgery in the posterior maxilla often poses a challenge due to insufficient available bone. Sinus floor elevation was developed to increase the needed vertical height to overcome this problem. However, grafting materials used for the sinus lift technique eventually show resorption. The present study radiographically compared and evaluated the changes in height of the grafting materials after carrying out maxillary sinus elevation with a window opening procedure. This study also evaluated the difference between two xenogenic bone materials when being used for the sinus lifting procedure. Methods: Twenty-one patients were recruited for this study and underwent a sinus lift procedure. All sites were treated with either bovine bone (Bio-$Oss^{(R)}$) with platelet-rich plasma (PRP) or bovine bone (OCS-$B^{(R)}$)/PRP. A total of 69 implants were placed equally 6-8 months after the sinus lift. All sites were clinically and radiographically evaluated right after the implant surgery, 7-12 months, 13-24 months, and 25-48 months after their prosthetic loading. Results: Changes of implant length/bone length with time showed a statistically significant decreasing tendency (P<0.05). There was no significant change in the Bio-$Oss^{(R)}$ group (P>0.05). In contrast, the OCS-$B^{(R)}$ group showed a significant decrease with time (P<0.05). However, no significant difference was observed between the two groups (P>0.05). Conclusions: The results showed that there was significant reduction in comparison with data right after placement, after 7 to 12 months, 13 to 24 months, and over 25 months; however, reduction rates between each period have shown to be without significance. No significant difference in height change was observed between the Bio-$Oss^{(R)}$ and the OCS-$B^{(R)}$ groups.