• Title/Summary/Keyword: Winding

검색결과 2,086건 처리시간 0.027초

Performance Comparison of the Railway Traction IPM Motors between Concentrated Winding and Distributed Winding

  • Park, Chan-Bae;Lee, Byung-Song;Lee, Hyung-Woo
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권1호
    • /
    • pp.118-123
    • /
    • 2013
  • This paper presents performance comparison between concentrated winding and distributed winding of IPMSM (Interior Permanent Magnet Synchronous Motors) which is recently used for light-weight railway applications. Motors are designed on various schemes and analyzed by using FEM (Finite Element Method) instead of EMCNM (Equivalent Magnetic Circuit Network Method) in order to take into account saturation and non-linear magnetic property. The overall performance such as torque, torque ripple, losses, demagnetization, efficiency, power density and so on are investigated in detail at the rated and maximum operating speed. The results of the analysis found that both concentrated and distributed winding IPMSMs are promising candidates for high power railway traction motor.

열연코일 권취형상 불량 자동진단 시스템 개발 (Development of Diagnostic System for Winding Profile Abnormality of Hot Coils)

  • 이성진
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 추계학술대회논문집A
    • /
    • pp.590-595
    • /
    • 2000
  • On the contrary to the increasing needs of shape qualities, most of quality inspections are carried out by manual or operator's insight. To find the causes of shape inferiority, it is required to gather and analyze the shape measurement data. As a result the winding profile measurement system ($TELE-SCANNER^{(R)}$) is developed to analyze the coiling process and automate the manual measuring process for winding profile of hot-rolled coils. The winding profile measurement system measures and analyzes winding profile shapes of hot-rolled coils, and classifies them into several dominant patterns that are related to normal or abnormal mechanical conditions of down-coiler. The system also contains analysis software to quantify the winding profile shapes and patterns, and to produce statistics to help search the causes of profile shape inferiority.

  • PDF

Convex형 권선배치방식을 취한 권철심변압기의 충격파절연설계에 관한 연구 (Study on Insulation Design of Surge Voltages for Convex Winding type Ribbon Core Transformer)

  • 황영문;조철제;김중한
    • 전기의세계
    • /
    • 제22권3호
    • /
    • pp.13-24
    • /
    • 1973
  • In this report, as a method to solve the problems on impulse insulation coordination in ribbon core transformer owing to it's BIL stepping up, new design to alter winding distribution of multiple-layer concentric winding to Convex type winding is proposed. The main focus of this method is to settle the weakness of axial direction insulation strength and as a result of theoretical analysis through experiment of model transformers, the following conclusions are obtained; (a) As the electric loadings in a design which increases by strengthenning axial direction insulation endurance in presently avarilable transformers owing to it's BIL stepping up can be restricted in Convex type winding, reasonable design will be suited to the transformer with higher BIL. (b) Convex type winding is a very improved insulation design in respect of insulation coordination because it has shield plate effect to even impulse oscillation. (c) There is a disadvantage to cause leakage flux to increase in Convex type winding, however, the constancy of electric loadings in a design in spite of BIL stepping up restricts the increase of leakage flux to some extent.

  • PDF

Alternate Pirn의 권취형상 제어를 위한 기구학적 제어 알고리즘 개발 (Development of a Kinematic Winding Control Algorithm for the Alternate Pirn)

  • 최영휴;김광영;김종수;박대원
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1996년도 추계학술대회 논문집
    • /
    • pp.413-418
    • /
    • 1996
  • Alternate pirn winding is more difficult to control than others because starting points of its traverse strokes are changed alternately through the winding operations. However, the alternate pirn winding is ye useful method because the yarn can be hardly broken when it is unwinded from full packaged bobbin. This paper presents kinematic control algorithm for the alternate pirn. The proposed algorithm can decide the values of control variables such as bobbin speed and traverse speed from the given input parameters and constraints by using the kinematic relations of the winding mechanism. The compute simulations and experimental verifications of the developed winding control algorithm are carried out It is concluded that the proposed algorithm is an efficient and reliable alternative to traditional trial and error control methods.

  • PDF

Permanent Magnet Excitation in Small Axial Flux Driver with MR Sensor and Thin Film Multilayer Winding

  • 최도순
    • 한국산업정보학회논문지
    • /
    • 제6권1호
    • /
    • pp.70-76
    • /
    • 2001
  • NdFeB로 만들어진 permanent magnet dc driver는 많은 분야에서 사용된다. 그중 소형 disk type servo driver는 컴퓨터의 hard disk driver나 floppy driver등과 같은 소형기기의 구동용으로 사용된다. 기존의 dc drive는 coil를 감아 winding으로 사용한다. 만들어진 driver에는 coper printed multilayer winding을 사용하였다. 이 논문에서는 thin film multilayer winding의 제조방법, 특성에 관하여 논한다. 또한 dc driver의 commutation를 위해 사용되는 hallsensor 대신에 비 선형 특성의 MR sensor를 선형화시켜 driver의 commutation에 사용하였으며 이렇게 만들어진 소형 driver의 rpm, torque등의 특성을 연구하였다.

  • PDF

LabVIEW를 이용한 소형 유도전동기의 권선고장 자동진단 (Auto-Detection of Stator Winding Fault of Small Induction Motor using LabVIEW)

  • 송명현;박규남;한동기;우혁재
    • 전기학회논문지P
    • /
    • 제55권4호
    • /
    • pp.202-206
    • /
    • 2006
  • In this paper, an auto detection method of stator winding fault of small induction motor is suggested. The Park's vector pattern which is obtained from 3-phase current signal by d-q transforming, is very good to detect winding fault. Comparing the Park's vector pattern of testing motor with its of healthy motor, the Park's vector pattern of fault motor is became an ellipse and the asymmetry is increased by the winding fault series. So for detecting the dis-symmetry, id-filtered function, Min-value, and Max-value are suggested for auto detecting. Using LabVIEW programing, 3-phase healthy motor and several kind of winding fault motors are tested and the test results are shown that the suggested method can gives us a possibility of an auto detecting winding fault.

초전도 한류소자의 병렬연결에 따른 자속구속형 초전도 한류기의 특성 분석 (Characteristics of a Flux-Lock Type Superconducting Fault Current Limiter According to the Parallel Connection of the Superconducting Elements.)

  • 오금곤;정병익;최효상
    • 전기학회논문지P
    • /
    • 제57권2호
    • /
    • pp.198-201
    • /
    • 2008
  • We investigated the operating characteristics of the flux-lock type superconducting fault current limiter(SFCL) with the parallel connection between the primary and secondary windings which are connected with two superconducting units in series. The parallel connection for current level increase of the flux-lock type SFCL is necessary to apply the SFCL into the power system. The resistance generated in superconducting units was dependent upon the winding direction of the primary and the secondary coils, which can reduce the power burden. The resistance of the superconducting elements in the subtractive polarity winding is higher than that of the additive polarity winding. The fault current limiting effect of the subtractive polarity winding is better than that of the additive polarity winding. From this results, we confirmed that the power capacity of the flux-lock type SFCL could be increased by the parallel connection of the superconducting units.

면취기 시스템에 있어서 부하의 관성모멘트에 따른 가변 PID 일정 장력제어의 기초연구 (A Basic Study on the constant Tension control with variable PID as a function of inertia moment in the winding roll System)

  • 허진;전홍배;김철한;사공건
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 하계학술대회 논문집
    • /
    • pp.654-657
    • /
    • 2000
  • In the winding system, the constant tension control is too important. In this study, we've used a variable PID system as a function of a radius of winding roll. As a result, it was possible to measure a winding roll radius in the real time by making a mathematical model for measuring a winding roll radius. Finally, we've compared PID parameters as a function of winding roll radius after getting PID parameters in terms of the Ziegler & Nichols(ZN) method.

  • PDF

500MW 급 대형 발전기 권선단부의 전자기력과 동특성 해석 (Analysis of Vibration and Electromagnetic Forces on a Generator End-winding for 500 MW Fossil Power Plant)

  • 김철홍;주영호
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 추계학술대회논문집 II
    • /
    • pp.826-831
    • /
    • 2001
  • Electromagnetic forces generate vibrations in the end-winding of large generators. A finite element analysis using a commercial S/W is performed to calculate electromagnetic force of end-winding in two pole generator for 500 MW fossil power plant. Also, this paper presents analytical and experimental modal analysis results of generator end- winding. Using validated FE model, 3D electromagnetic model which computes the forces on the end-winding is coupled with a 3D mechanical model which calculates the dynamic displacement and stress under electromagnetic forces. These results will be used to evaluate reliability of end-winding and applied to update model.

  • PDF

Effect of Winding Configuration on the kVA Rating of Wye-connected Autotransformer Applied to 12- pulse Rectifier

  • Meng, Fangang;Du, Qingxiao;Gao, Lei;Li, Quanhui;Man, Zhongcheng
    • Journal of Power Electronics
    • /
    • 제19권2호
    • /
    • pp.463-474
    • /
    • 2019
  • This paper presents the effect of winding configuration on the kVA rating of a wye-connected autotransformer applied to a 12-pulse rectifier. To describe the winding configuration of the wye-connected autotransformer, position and proportional parameters are defined and their quantitative relation is calculated. The voltages across and currents through the windings are measured under different winding connections. Consequently, a relation between the kVA rating and position parameter is established in accordance with the analysis, and the optimal winding configuration is obtained on the basis of this relation. A wye-connected autotransformer with the least equivalent kVA rating and simplest winding configuration is designed and applied to the 12-pulse rectifier. Simulations and experiments are conducted to validate the theoretical analysis.