• 제목/요약/키워드: Wind tunnel experiments

검색결과 228건 처리시간 0.02초

차량용 열제어 관리 시스템의 성능 시뮬레이션 프로그램 개발 (Development of Simulation Program of Vehicle Thermal Managements System)

  • 배석정;허형석;김현철
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 춘계학술대회논문집
    • /
    • pp.345-348
    • /
    • 2008
  • The computer-aided performance simulation can reduce periods for development of products and cut down on the cost comparing with former trial-and-error procedures. This study has developed a simulation program for a vehicle thermal management system integrating an engine cooling system and an air conditioning system considering interactions and arrangement of air side heat exchangers such as power steering oil cooler, air-cooled transmission oil cooler, condenser, and radiator. The program may be also used for the system performance analysis according to the configuration of the engine coolant side heat exchangers such as water-cooled transmission oil cooler, EGR cooler, and heater core. Experiments utilizing an environmental wind tunnel has been conducted to assess the performance of the system according to the arrangement of air side heat exchangers. Some modification of the coolant loop layout can enhance the heat core performance up to 7% according to the results of the simulations.

  • PDF

MEMS 기술을 이용한 미소 리블렛 필름 제작 및 항력 감소에의 응용 (Fabrication of a Micro-Riblet Film Using MEMS Technology and Its Application to Drag Reduction)

  • 한만희;허정기;이상준;이승섭
    • 대한기계학회논문집B
    • /
    • 제26권7호
    • /
    • pp.991-996
    • /
    • 2002
  • This paper presents the fabrication method of a micro-riblet film (MRF) using MEMS technology and the experimental results of the drag reduction of an airfoil with MRFs. Riblets having grooved surface in the streamwise direction has been proven as an effective passive control technique of the drag reduction. A V-grooved pattern on (100) silicon wafer is etched with anisotropic bulk micromachining. The MRF is completed by replicating the V-grooved pattern with polydimethylsiloxane (PDMS). Experiments were performed by measuring a velocity field behind the trailing edge of a NACA 0012 airfoil with and without MRFs in a closed-type subsonic wind tunnel using particle image velocimetry (PlV) technique. The MRF provides about 3.8 % drag reduction compared to the drag on a smooth airfoil when the freestream velocity of wind tunnel is 3.3 m/s.

횡방향 유속 변화에 따른 고압 가솔린 팬형 인젝터의 분무특성 (Spray Characteristics of High Pressure Fan Spray Injector with Various Crossflow Speed)

  • 최재문;문석수;배충식
    • 한국분무공학회지
    • /
    • 제10권3호
    • /
    • pp.38-44
    • /
    • 2005
  • The direct injection into the cylinders has been regarded as a way of the reduction in fuel consumption and pollutant emissions. The spray produced from the injector of DIS(Direct Injection Spark Ignition) engine is of paramount importance in DISI engines. Fan-spray injector as well as swirl-spray injector was developed and utilized to the DISI engines. The interaction between air flow and fuel spray was investigated in a steady flow system embodied in a wind tunnel to simulate the variety of flow inside the cylinder of the DISI engineer. The direct Mie scattered images presented the macroscopic view of the liquid spray fields interacted with crossflow. Particle sizes of fuel droplets were measured with phase Doppler anemometer(PDA) system. A faster cross-flow field made SMD larger and $D_{10}$ smaller. The experiments show the interaction of air flow field and the fuel spray field of fan-spray. The results can be utilized to construct the data-base for the spray and fuel-air mixing mechanism as a function of the flow characteristics.

  • PDF

경계층 유동의 흡입에 의한 수직충격파 진동저감 (Reduction of Normal Shock-Wave Oscillations by Turbulent Boundary Layer Flow Suction)

  • 김희동
    • 대한기계학회논문집B
    • /
    • 제22권9호
    • /
    • pp.1229-1237
    • /
    • 1998
  • Experiments of shock-wave/turbulent boundary layer interaction were conducted by using a supersonic wind tunnel. Nominal Mach number was varied in the range of 1.6 to 3.0 by means of different nozzles. The objective of the present study is to investigate the effects of boundary layer suction on normal shock-wave oscillations caused by shock wave/boundary layer interaction in a straight duct. Two-dimensional slits were installed on the top and bottom walls of the duct to bleed turbulent boundary layer flows. The bleed flows were measured by an orifice. The ratio of the bleed mass flow to main mass flow was controlled below the range of 11 per cent. Time-mean and fluctuating wall pressures were measured, and Schlieren optical observations were made to investigate time-mean flow field. Time variations in the shock wave displacement were obtained by a high-speed camera system. The results show that boundary layer suction by slits considerably reduce shock-wave oscillations. For the design Mach number of 2.3, the maximum amplitude of the oscillating shock-wave reduces by about 75% compared with the case of no slit for boundary layer suction.

차동식 열감지기의 작동온도와 작동시간 (Operating Temperature and Time of Rate of Rise Heat Detector)

  • 류호철;이병곤
    • 한국안전학회지
    • /
    • 제9권1호
    • /
    • pp.61-67
    • /
    • 1994
  • Rate of rise heat detectors that respond to the heat generated in fire plume and alarm when the temperature reaches a specified point, give a great influences to the loss of life and property according to their reaction sensitivity. In this study, simple equations were derived which can be predicted the response time and temperature of the rate of rise heat detector with the results of hot wind tunnel tests and compartment fire experiments.

  • PDF

강제 가진에 의한 교량 플러터계수 추출 (Extraction of bridge flutter derivatives by a forced excitation)

  • 이승호;권순덕
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2009년도 춘계학술대회 논문집
    • /
    • pp.538-544
    • /
    • 2009
  • A vibration excitation system was designed and built of forced vibration experiments for using stepping motor and load cell. The identified flutter derivatives of the thin-plate acrylic model were very close to the analytical results of the idealized plate presented by Theodorsen. Five types of sectional models were tested in the wind tunnel using the proposed forced vibration method. To investigate the frequency, amplitude and angle of attack effects on flutter derivatives.

  • PDF

Wind tunnel study of wake-induced aerodynamics of parallel stay-cables and power conductor cables in a yawed flow

  • Jafari, Mohammad;Sarkar, Partha P.
    • Wind and Structures
    • /
    • 제30권6호
    • /
    • pp.617-631
    • /
    • 2020
  • Wake-induced aerodynamics of yawed circular cylinders with smooth and grooved surfaces in a tandem arrangement was studied. This pair of cylinders represent sections of stay-cables with smooth surfaces and high-voltage power conductors with grooved surfaces that are vulnerable to flow-induced structural failure. The study provides some insight for a better understanding of wake-induced loads and galloping problem of bundled cables. All experiments in this study were conducted using a pair of stationary section models of circular cylinders in a wind tunnel subjected to uniform and smooth flow. The aerodynamic force coefficients and vortex-shedding frequency of the downstream model were extracted from the surface pressure distribution. For measurement, polished aluminum tubes were used as smooth cables; and hollow tubes with a helically grooved surface were used as power conductors. The aerodynamic properties of the downstream model were captured at wind speeds of about 6-23 m/s (Reynolds number of 5×104 to 2.67×105 for smooth cable and 2×104 to 1.01×105 for grooved cable) and yaw angles ranging from 0° to 45° while the upstream model was fixed at the various spacing between the two model cylinders. The results showed that the Strouhal number of yawed cable is less than the non-yawed case at a given Reynolds number, and its value is smaller than the Strouhal number of a single cable. Additionally, compared to the single smooth cable, it was observed that there was a reduction of drag coefficient of the downstream model, but no change in a drag coefficient of the downstream grooved case in the range of Reynolds number in this study.

트윈 빌딩의 적합 직교 분해 기법을 이용한 풍하중 및 풍응답 평가 (Evaluating Wind Load and Wind-induced Response of a Twin Building using Proper Orthogonal Decomposition)

  • 김법렬
    • 한국전산구조공학회논문집
    • /
    • 제31권6호
    • /
    • pp.309-314
    • /
    • 2018
  • 트윈 빌딩의 풍하중의 특성과 구조적 특성은 일반 고층건물보다 복잡하다. 이러한 특성을 조사하기 위해서 풍동실험을 통해서 트윈 빌딩의 풍압을 계측하였다. 계측된 데이터와 적합 직교 분해 기법을 이용하여 풍압의 패턴을 파악하였다. 1차 모드에서는 채널링 효과가 2차 모드에서는 와류 효과가 나타났다. 또한, 두 빌딩의 하중의 상관관계를 파악하였는데, 풍 방향 하중은 양의 상관관계를 가지며, 풍 직각 방향의 하중은 명확한 상관관계가 나타나지 않았다. 이러한 상관관계는 횡 방향 변위에도 영향을 미쳤다. 양의 상관관계를 가지면 트윈 빌딩을 연결하는 구조부재의 영향이 적게 작용한 반면에 음의 상관관계를 가지면 연결 구조부재의 영향이 횡 방향의 변위를 줄이는데 큰 영향을 미치게 되었다.

간척지 내 단동형 온실의 풍하중에 대한 구조 안정성 분석 (Structural Safety of Single-Span Greenhouses under Wind Load of Costal Reclaimed Lands)

  • 홍세운;김락우;최원
    • 한국농공학회논문집
    • /
    • 제59권4호
    • /
    • pp.109-117
    • /
    • 2017
  • Coastal reclamation has created large flat lands, part of which is an attractive site to construct greenhouse complexes for the horticulture industry. Wind environments over these coastal lands are entirely different from those of the inland area, and demand increased structural safety. The objective of this study is to evaluate the structural safety of two single-span greenhouses, peach type and even-span type, under the wind characteristics of coastal reclaimed lands. The wind pressure coefficients acting on the walls and roofs of two greenhouses were measured by wind tunnel experiments, and those acting on the roofs were approximately two times larger than those suggested by the existing design guidelines. Consequently, structural analysis conducted by SAP2000 showed that greenhouse structures designed by the existing guidelines might lead to structural failure under coastal wind conditions because their maximum allowable wind speeds were lower than the design wind speed. Especially, the peach type greenhouse constructed in a reclaimed land could be damaged by approximately 48 % of the design wind speed and needed improvement of structural designs. This study suggested increasing the spacing of rafters with thicker pipes for the peach type greenhouse to enhance economic feasibility of the building under strong wind conditions of reclaimed lands.

건물 옥상에 설치되는 옥상 간판의 피크풍압 분포에 대한 연구 (A Study on the Distribution of the Peak Wind Pressure for Rooftop Signboards)

  • 남병희;유장열;이남훈;유기표
    • 한국공간구조학회논문집
    • /
    • 제18권2호
    • /
    • pp.79-86
    • /
    • 2018
  • Unlike other types of outdoor advertisements, rooftop signboards are installed on the roofs of buildings, rather than on their outer walls. This means that the area of a rooftop signboard is commonly larger than that of a general outdoor signboard. Moreover, as such signboards are greatly influenced by the wind, they can suffer a lot of damage from typhoons and strong winds every year. However, there is no wind load specification for rooftop signboards. In this study, wind pressure experiments were conducted to investigate the peak wind pressure on each side of rooftop signboards installed on the roofs of 5-15 story buildings in a city center. The minimum peak wind pressure coefficient was -3.0 at the bottom edges of the front and back of the rooftop signboards and -2.0 along the entire length of the sides. As the height of the rooftop signboard increased with the increasing height of the buildings, the peak value was found to be larger than the absolute peak value for the minimum peak wind pressure coefficient. The maximum and minimum peak wind pressure distributions of the rooftop outdoor signboards were influenced by the position of the signboard and the wind angle.