• Title/Summary/Keyword: Wind instrument

Search Result 91, Processing Time 0.034 seconds

COMPARISONS OF DENTAL ARCHES AND CROWDINGS BETWEEN MUSICAL WIND-INSTRUMENT PLAYERS GROUPS AND NON-WIND INSTRUMENT PLAYERS GROUP (관악기연주군과 비관악기군의 치열궁 및 Crowding에 관한 비교연구)

  • Lee, Won You
    • The korean journal of orthodontics
    • /
    • v.17 no.2
    • /
    • pp.289-297
    • /
    • 1987
  • For the comparisons of dental archs and crowdings between musical wind instrument players groups and non-wind instrument players groups, 64 male wind instrument players and 31 non-wind instrument players group were selected. The results of the measurements were as follow. 1 Upper intercanine widths, upper basal arch widths, lower basal arch widths were statistically significant between musical wind instrument players groups (Class A, Class B) and non-wind musical instrument players group. 2 The mean value of upper intercanine width m Class A ($373{\pm}2.3mm$) was greater than than in Class B ($362{\pm}17mm$) and non-wind musical instrument players group($360{\pm}16mm$) 3 The mean value of lower basal arch width m Class B ($422{\pm}25mm$) was greater than that in non wind instrument players group ($395{\pm}28mm$). 4 The differences in the mean values of crowdings between Class A and Class Band non-wind instrument players group were not statistically significant.

  • PDF

A Study on the Pulmonary Functional Characteristics of Amateur Wind Instrument Players and Choir Members

  • Baek, Jeong Yun;Kim, Joong Hwi
    • The Journal of Korean Physical Therapy
    • /
    • v.34 no.5
    • /
    • pp.248-254
    • /
    • 2022
  • Purpose: This study was undertaken to identify the effect of amateur wind musical performance and choir activity on pulmonary function, and to determine the usefulness as a respiration training program by measuring the pulmonary functions of subjects. Methods: A total of 90 subjects (wind instrument players group=30, choir members group=30, control group=30) participated in the experiment. Pulmonary function test (FVC, FEV1, FEV1/FVC ratio, MVV, SVC, PEF, FEF 25-75%, IRV, ERV) was conducted using a spirometer (CardioTouch 3000S, Bionet, Seoul, Republic of Korea). Each factor was measured 3 times to meet the American Thoracic Society criteria, and the highest value was used in the analysis. Results: Comparing pulmonary function between the amateur wind instrument players (WP), amateur choir members (CH), and control (CG) groups revealed significant differences in FEV1, FVC, FEV1/FVC, and ERV (p<0.05). Highest values were obtained in the WP group. Significant differences were obtained for various factors in the multiple regression analysis of practice year (PY), practice time per week (PTPW), and exercise time per week (ETPW): FEV1 and FVC in PY, FEV1/FVC in PTPW, and FEV1/FVC, MVV, PEF, and FEF (25-75%) in ETPW. Conclusion: Amateur wind instrument performance effectively improves lung function and is useful as a breathing training program for preventing debilitation and improving respiratory function.

Mouthpiece Modeling of the Electronic Wind Instrument Using a Propeller and Linear Analysis for Fast Tracking Wind Velocity (빠른 바람의 세기 추적을 위한 프로펠러를 사용한 전자 관악기 취구의 선형 모델링)

  • Kwak, Jae-Hyung;Lee, Gang-Seong
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.35 no.3C
    • /
    • pp.295-301
    • /
    • 2010
  • In this paper, we propose a new mouthpiece model for the electronic wind instrument using a propeller and linear analysis for fast tracking wind velocity blown. This method is a modification of the velocity anemometer for fast tracking wind velocity by the propeller's angular velocity (speed of revolution). In the case of velocity anemometer, wind velocity is calculated using the property that wind velocity is in proportion to the propeller's angular velocity. However, wind velocity and angular velocity of the propeller are not in one-one correspondence because wind velocity takes some transitional time for the expected wind velocity to be calculated from angular velocity. To resolve this problem, we propose a method for finding the impulse response of the system which can be considered as a linear system, and for estimating the wind velocity by deconvolving the propeller's angular velocity with the impulse response. To experiment and to prove the validity of the proposed system, we designed a mouthpiece model which consists of a motor, a propeller and an encoder. The result of estimated wind velocity in this method showed that this system is about eightfold faster than the method by the conventional velocity anemometer.

CLINICAL STUDY ON THE EFFECT OF WIND INSTRUMENT PLAYING ON PERIODONTAL CONDITIONS (관악기 연주자의 치주상태에 관한 연구)

  • Lee, Won-You;Choi, Seong-Ho;Kim, Sung-Hee
    • Journal of Periodontal and Implant Science
    • /
    • v.24 no.2
    • /
    • pp.390-396
    • /
    • 1994
  • This study investigates the effect of wind instrument playing on the periodontal condition by comparing and analyzing wind instrument players and non-wind instrument players by various clinical paramenters, including periodontal index, bleeding index, simplified oral hygiene index, and non-functional tooth index. The subjects consist of 65 wind instrument players and 31 non-players. The players were divided into 4 groups ; Those who use cup-shaped mouthpieces as Group A, single reed mouthpieces as Group B, double reed mouthieces as Group C, and hole mouthpieces as Group D. Non-players are designated as Group E. The results are as follows ; 1. Periodontal Index Group A recorded $1.2{\pm}0.7$, Group B $1.1{\pm}0.7$, Group C $1.3{\pm}0.5$, Group D $2.1{\pm}0.5$, and Group E $0.9{\pm}0.6$, with no statistically significant differences among the groups. 2. Bleeding Index Group A shwed 0.23, Group B 0.25, Group C 3.0, Group D 0.38, and Group E 0.23, with no statistically significant differences among the groups. 3. Non-functional Tooth Index Group A recorded 2.0, Group B 1.0, Group C 3.0, Group D 0, Group E 0.7, with no statistically significant differences among the groups. 4. Simplified Oral Hygiene Index Buccal sides of maxillary 1st molars, lingual sides of mandibular 1st molars, labial sides of maxillary anterior teeth, and lingual sides of mandibular anterior teeth were investigated, and there was no statistically significant differences among the groups.

  • PDF

The Effect of Wind-instrument Centered Music Therapy on Respiration, Oral Motor and Articulation for Patients with Cervical Cord Injury - Case Study - (취주악기를 사용한 음악치료가 경수손상환자의 호흡, 구강운동 및 조음에 미치는 영향 -사례연구-)

  • Kim, Tai youn;Park, Shin ae;Lee, Yong seok
    • 재활복지
    • /
    • v.21 no.1
    • /
    • pp.233-252
    • /
    • 2017
  • The purpose of this study is to investigate the influence on respiration, oral motor and articulation using wind-instrument centered music therapy for patients with cervical cord injury who need continuous train of respiratory muscle. Three patients with cervical cord injury who needed continuous training of respiratory muscle were selected and post data was analyzed. The harmonica using both exhalation and inspiration was selected as an wind-instrument. Each session was taken 30 ~ 40 minutes, once a week from total 6 weeks with small group. Material about every session's work was provided for individual to maintain practice after program. Oral motor and articulation test was done to assess reflecting features of maximal expiratory flow and wind-instrument of factor related breath. Maximal expiratory flow has increased by average 25ml more, articulation has increased by 3.16 points more and the movement of oral motor has increased 11.67 points more than pre-test from the analyzation. In the comparison of the details, the increase of oral motor function was confirmed from scores on the jaw and tongue except for the lips. Based on the results of this study, this study suggests that wind-instrument centered music therapy will be a practical and effective intervention for respiratory rehabilitation in patients with cervical cord injury.

Development of 3 - Dimensional Ultrasonic Wind Direction Anemometer Measurement Technique Using Time Division Method (시분할 방식을 이용한 3차원 초음파 풍향풍속계 측정기술 개발)

  • Lee, Woo-Jin;Choi, Jae-Young;Kim, Kyung-Won;Yim, Jae-Hong
    • Journal of Sensor Science and Technology
    • /
    • v.26 no.1
    • /
    • pp.66-72
    • /
    • 2017
  • The three dimensional ultrasonic anemometer was constructed to reduce the disadvantages of the two-dimensional anemometer and to be free from the use environment. Three pairs of transmitting and receiving ultrasonic sensors were designed to face each other at an angle of $45^{\circ}$ to the upper and lower surfaces at intervals of $120^{\circ}$. 200 kHz ultrasonic sensor Oscillation, transmission and reception, level detection, power supply circuit were designed and U, V, W wind speed vector components were obtained by measuring the time of first received ultrasonic pulse by transmitting pulse ultrasound. It is implemented as firmware in ARM Coretex-M3 processor so that horizontal and vertical wind direction and wind speed can be converted into digital signal by vector calculation. In this study, The three-dimensional ultrasonic anemometer can complement the disadvantages of the two-dimensional anemometer (mechanical and ultrasonic), and it is expected to gradually replace the two-dimensional anemometer due to its high utilization rate by collecting additional information such as vertical wind.

Primary Study to Develop the Instrument of Pattern Identification for Common Cold (감모변증도구 개발에 관한 예비 연구)

  • Byun, Jun-Seop;Yang, Su-Young;Kang, Wee-Chang;Park, Yang-Chun
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.23 no.6
    • /
    • pp.1226-1233
    • /
    • 2009
  • Common cold occurs frequently and occupies an important position in medical treatment however obvious treatment is not suggested. There has been no agreement of pattern identification for common cold in oriental medicine. The purpose of this study is to develop a standard instrument of pattern identification for common cold which will be applied to clinical research. The items and structure of the instrument were based on review of published literature. The advisor committee on this study was organized by 9 oriental respiratory internal medicine professors of 11 oriental medical colleges nationwide. The experts attended 3 consultation meetings and discussed developing the instrument, and we also took professional advices by e-mail. The results were as follows; First, we divided the pattern identification of common cold into nine pattern: Wind-cold type, Wind-heat type, Contain summerheat type, Contain dampness type, Qi deficiency type, Blood deficiency type, Yang deficiency type, Yin deficiency type, Influenza. Second, we got the mean weights to each symptom of nine pattern identification which had been scored on a 5-point scale - ranging from 0 to 4 by the 9 experts. Third, we made out the Korean instrument of the pattern identification for common cold. It was composed self reporting questionnaire and researcher reporting questionnaire. Though this study is not proved about validity, reliability, the instrument of pattern identification for common cold is meaningful and expected to be applied to the subsequent research. And also, we hope to improve the instrument and make up for this study through various research and discussion.

A Study on the Development of Hourly Evaporation Recording Instrument for Class A Pan (대형증발계용 매시간 증발 기록계 개발에 관한 연구)

  • Bu-Yong Lee
    • Journal of Environmental Science International
    • /
    • v.10 no.5
    • /
    • pp.323-327
    • /
    • 2001
  • A new method is developed to estimate the evaporation of water from a surface with high accuracy and resolution. The principle of new method is to detect a weight change of buoyant weight according to a change in water level of Class A Pan mesured by the use of a strain-gauge load cell. Field test of evaporation recording new instrument was carried out at Suwon for 10 days July 1999. It is possible in field observation to measure hourly evaporation amount by newly developed evaporation recording instrument in Class A Pan against strong solar radiation. Present study provide a possibility of domestic high accuracy instrument development below than 0.1mm water level measurement accuracy. If there is low humidity and high wind speed conditions which is possible to evaporate from water surface during night time. And it needs continuous study to understand between meteorological elements and latent heat effect at ground level by field observation study using high accuracy evaporation recording instrument.

  • PDF

Frequency Characteristics Analysis for Quality Assessment on Korean Traditional Wind Instruments (국악관악기 품질평가를 위한 음고특성분석)

  • Park, Soo-Hong;Ock, Seung-Ho;Seo, In-Hwa;Kim, So-Ri;Jeong, Hwan-Hee
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.302-307
    • /
    • 2011
  • In this study, peak frequencies of korean traditional wind instruments according to instruments were measured for introducing quality certification system. Also major dimensions of instruments were measured too, for analysis on manufacturing precesion.

  • PDF

Analysis of the Climate inside Multi-span Plastic Greenhouses under Different Shade Strategies and Wind Regimes

  • He, Keshi;Chen, Dayue;Sun, Lijuan;Huang, Zhenyu;Liu, Zhenglu
    • Horticultural Science & Technology
    • /
    • v.32 no.4
    • /
    • pp.473-483
    • /
    • 2014
  • In this work, the effects of shade combination, shade height and wind regime on greenhouse climate were quantified. A two-dimensional (2-D) computational fluid dynamics (CFD) model was developed based on an 11-span plastic greenhouse in eastern China for wind almost normal to the greenhouse orientation. The model was first validated with air temperature profiles measured in a compartmentalized greenhouse cultivated with mature lettuce (Lactuca sativa L., 'Yang Shan'). Next, the model was employed to investigate the effect of shade combinations on greenhouse microclimate patterns. Simulations showed similar airflow patterns in the greenhouse under different shade combinations. The temperature pattern was a consequence of convection and radiation transfer and was not significantly influenced by shade combination. The use of shade screens reduced air velocity by $0.02-0.20m{\cdot}s^{-1}$, lowered air temperature by $0.2-0.8^{\circ}C$ and raised the humidity level by 0.9-2.0% in the greenhouse. Moreover, it improved the interior climate homogeneity. The assessment of shade performance revealed that the external shade had good cooling and homogeneity performance and thus can be recommended. Furthermore, the effects of external shade height and wind regime on greenhouse climate parameters showed that external shade screens are suitable for installation within 1 m above roof level. They also demonstrated that, under external shade conditions, greenhouse temperature was reduced relative to unshaded conditions by $1.3^{\circ}C$ under a wind speed of $0.5m{\cdot}s^{-1}$, whereas it was reduced by merely $0.5^{\circ}C$ under a wind speed of $2.0m{\cdot}s^{-1}$. Therefore, external shading is more useful during periods of low wind speed.