• 제목/요약/키워드: Wilcoxon Rank Sum Test

검색결과 162건 처리시간 0.028초

하악골과 장골의 조직형태계측 비교 (COMPARATIVE HISTOMORPHOMETRIC ANALYSIS OF MANDIBLE AND ILIAC BONE ON BONE DENSITY)

  • 유소정;정문규
    • 대한치과보철학회지
    • /
    • 제38권1호
    • /
    • pp.12-25
    • /
    • 2000
  • To demonstrate possible influences of general bone density on the mandible, histomorphometric analysis was carried out in mandibles and iliac bones and the correlation of the two bone densities was tested. Comparison of bony density in women and men over 60 years in the mandible was carried out too. Quantitative computed tomography(QCT) was taken in cross-section of mandibles at the same site where histomorphometric analysis was peformed to evaluate the reliability of QCT. The analysis included 40 cadavers with no known diseases affecting the bones. The subjects consisted of 15 females and 25 males with a mean age of 60.3 years. Spearman correlation analysis and Wilcoxon rank sum test was performed. The results were as follows. 1. There was statistically no correlation between the mandible and iliac bone in the values of corrected cortical width(CCW), cortical porosity(POR) in cortex, and total bone volume(TBV), mean trabecular plate thickness(MTPT), mean trabecular plate density(MTPD), and mean trabecular plate separation(MTPS) in trabecular bone. 2. Comparison of women and men over 60 years, men had statistically higher bone density than women except fir POR of buccal and lingual cortex, and WTPD of alveolar trabeculae in mandible. 3. There was statistically significant correlation between TBV of trabecular bone and CT No., but not between POR and CT No. in mandible. According to the results above, there was no correlation between mandible and iliac bone density and between mandibular bony density and age. Further studies are required to support the results. A more noninvasive method to be able to measure the bone density of mandible should be developed and it is necessary to accumulate data on the normal values of bone density of mandible according to age and sex. Further study should be carried out about QCT to measure mandibular bony density using QCT.

  • PDF

인상 스캐닝 방법에 의해 제작된 디지털 치과 모형의 체적 안정성 평가 (Evaluation of Dimensional Stability of Digital Dental Model Fabricated by Impression Scanning Method)

  • 김재홍;김기백
    • 치위생과학회지
    • /
    • 제14권1호
    • /
    • pp.15-21
    • /
    • 2014
  • 본 연구에서는 구강으로부터 채득된 인상체를 스캐닝하여 디지털 모형을 제작하였을 때 제작된 디지털 모형의 체적 안정성을 평가하고자 하였다. 그리하여 환자의 구강을 가정한 상악 모형을 본 모형으로 채택하였다. 본 모형과 동일한 증례의 연구 모형을 치과용 석고를 이용하여 총 20개의 석고 모형을 제작하였다. 제작된 연구 모형 20개를 치과용 기성 트레이와 두 종류의 치과용 인상재를 이용하여 20개 연구 모형을 대상으로 20개의 인상을 채득하였다. 채득된 20개의 인상체를 치과용 스캐너로 스캐닝하는 방식으로 디지털 모형으로 변환하였다. 체적 안정성을 평가하기 위하여 6개의 대표 지점을 선정한 뒤 디지털 모형과 함께 디지털 모형의 근간인 석고 모형을 계측하였다. 그 결과 계측된 모든 부위에서 디지털 모형이 석고 모형보다 체적이 작은 것으로 조사되었고, 이는 통계적으로 유의하였다(p<0.05). 이러한 결과들로 추론하여 보았을 때 환자의 구강으로부터 채득된 인상체를 스캐닝하여 제작한 디지털 모형의 체적은 환자의 구강보다 작다는 것을 알 수 있었다. 그러나 이 차이는 미비한 것으로 여러 선행 연구 결과들을 근거로 하였을 때 임상적으로 허용이 가능한 것으로 생각된다.

불법약물 사용자의 약물사용 및 재사용 관련특성 (Drug use and Reuse Relating Characteristics in Illegal Drug Users)

  • 이소영
    • 한국보건간호학회지
    • /
    • 제16권2호
    • /
    • pp.400-411
    • /
    • 2002
  • This study was performed to identify the drug use and reuse relating characteristics and reuse relating factors in illegal drug users. Subjects consisted of 88 illegal drug users. Some of them were confined in a mental hospital or National Forensic Psychiatric Hospital located in Chung-nam province, others on attending a drug abuse prevention program in Seoul Probational Institute. Data were collected during the period from February 1, 2002 to February 25, 2002, and analyzed by SAS program. version 6.12. for Wilcoxon rank sum test, Pearson Correlation, Multiple regression. Results were as follows; 1. Drug use characteristics were as follows. $19.3\%$ was has drug family history and $20.7\%$ was has alcohol family history. Main drug was Phillopon$44.3\%$, inhalants $35.2\%$, LSD et al $22.7\%$. Drug use rate of months was everyday $31.2\%$, every other day $24.4\%$. 2. $100\%$ has experienced abstinence and reuse. Abstinence period was less than 12 months in $49.4\%$ and reuse period was less than 6 months in $58.6\%$. 3. Drug use and reuse characteristics related to general characteristics was identified as below. Abstinence period of male was longer than that of female. Person who have drug family history experienced more drugs and person who have family alcohol history started earlier. 4. Reuse periods was correlated with abstinence periods, age. And abstinence period was correlated with age and outcome that following reuse. 5. The multiple regression was used to identify the relating factors that influence reuse period and abstinence period. At the state of controlling abstinence period. inhalants users have 10.07 days shorter reuse period than others. And abstinence period had lengthened age, bad health status, early initiate age, and long reuse period.

  • PDF

구강내에서 임플랜트 지대주 형성 시 내부연결방식과 외부연결방식간의 열전달 효과 비교 (THE COMPARATIVE STUDY OF THERMAL INDUCTIVE EFFECT BETWEEN INTERNAL CONNECTION AND EXTERNAL CONNECTION IMPLANT IN ABUTMENT PREPARATION)

  • 허중보;고석민
    • 대한치과보철학회지
    • /
    • 제45권1호
    • /
    • pp.60-70
    • /
    • 2007
  • Statement of problem: The cement-type abutment would be needed for the reduction of its body in order to correct the axis and to assure occlusal clearance. In the case of intraoral preparation, there is a potential risk that generated heat could be transmitted into the bone-implant interface, where it can cause deterioration of tissues around the implant and failed osseointegration. Purpose: The purpose of this study was to assess the difference of the heat transmitting effect on external and internal connection implant types under various conditions. Material and method: For evaluating the effects of alternating temperature, the thermocoupling wires were attached on 3 areas of the implant fixture surface corresponding to the cervical, middle, and apex. The abutments were removed 1mm in depth horizontally with diamond burs and were polished for 30 seconds at low speed with silicone points using pressure as applied in routine clinical practice. Obtained data were analyzed using Mann-Whitney rank-sum test and Wilcoxon / Kruskal-Wallis Tests. Result: Increased temperature on bone-implant interface was evident without air-water spray coolant both at high speed reduction and low speed polishing (p<.05). But, the difference between connection types was not shown. Conclusion: The reduction procedure of abutment without using proper coolant leads to serious damage of oral tissues around the implant irrespective of external and internal connection type.

Preliminary clinic study on computer assisted mandibular reconstruction: the positive role of surgical navigation technique

  • Huang, Jin-Wei;Shan, Xiao-Feng;Lu, Xu-Guang;Cai, Zhi-Gang
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제37권
    • /
    • pp.20.1-20.7
    • /
    • 2015
  • Background: The objectives of the present study were to investigate the reliability and outcomes of computer-assisted techniques in mandibular reconstruction with a fibula flap and verify whether the surgical navigation system was feasible in mandible reconstructive surgery. Methods: Eight cases were enrolled in the computer assisted surgery (CAS) group and 14 cases in the traditional group. The shaping and fixation of the fibula grafts were guided by computer assisted techniques, which could be monitored with the BrainLAB surgical navigation system. The variation of mandible configuration was evaluated by CT measurement in the Mimics software, including the variation of length, width, height and gonial angle of the mandible. The 3D facial soft tissue alteration was also analyzed in 3D chromatogram by Geomagic software. Results: All 22 fibula flaps survived. The mandibular configurations and facial contours had a better clinic result in the CAS group. The length, width, height and gonial angle of the reconstructive mandible were more similar to the original one. The Wilcoxon rank sum test analysis suggested significant differences in the measurements. The chromatographic analysis also visually showed superiority over the traditional group. Conclusions: The computer assisted surgical navigation method used in mandibular reconstruction is feasible and precise for clinical application. The contour of the reconstructed mandible and facial symmetry are improved with computer techniques.

Effects of Taping the Lower Back on the Lumbopelvic Region and Hip Joint Kinematics During Sit-to-Stand

  • Kim, Si-Hyun;Park, Kyue-Nam;Kwon, Oh-Yun;Choi, Houng-Sik
    • 한국전문물리치료학회지
    • /
    • 제21권4호
    • /
    • pp.49-55
    • /
    • 2014
  • Excessive lumbar flexion during sit-to-stand (STS) is a risk factor for lower back pain. Postural taping can prevent unwanted flexion of the lumbar spine. This study aimed to demonstrate the effect of taping the lower back on the lumbopelvic region and hip joint kinematics during STS. Sixteen healthy subjects participated. All subjects performed the STS with and without taping of the lower back. A three-dimensional motion analysis system was used to measure the kinematics of the lumbar spine, pelvis, and hip joint during STS. The angle of the peak lumbar flexion, pelvic anterior tilting, and hip flexion and angular displacement of the lumbar spine between starting position and maximal lumbar flexion were collected. Paired t-tests, or Wilcoxon's rank-sum test for non-parametric distribution, were used to assess differences in the measurements with and without taping. A p-value <.05 was taken to indicate a significant difference. Significant differences were observed in the angle of the peak lumbar flexion, pelvic anterior tilting, hip flexion and angular displacement of the lumbar spine (p<.05). Taping was associated with a significant decrease in the angle of peak lumbar flexion and angular displacement of the lumbar spine between the starting position and maximal lumbar spine flexion. In addition, the peak angle of pelvic anterior tilting and hip flexion were significantly increased with taping. The findings of this study suggest that taping the lower back can decrease excessive lumbar flexion, and increase the pelvic anterior tilting and hip flexion motion during STS.

Blue LED 방식의 스캐너로 제작된 치과용 3차원 디지털 모형의 정확도 평가 (Evaluation of validity of three dimensional dental digital model made from blue LED dental scanner)

  • 김재홍;정재관;김기백
    • 한국산학기술학회논문지
    • /
    • 제15권5호
    • /
    • pp.3007-3013
    • /
    • 2014
  • 본 연구의 목적은 블루 LED 기반의 치과용 스캐너를 이용하여 제작된 3차원 디지털 모형의 정확도를 평가하는 것이다. 본 연구를 위하여 20개의 동일한 석고 모형 제작 후 블루 LED기반의 치과용 스캐너를 이용하여 석고 모형과 동일한 20개의 3차원 디지털 모형을 제작하였다. 정확도를 평가하기 위해 두 집단의 모형을 대상으로 6개의 계측 거리를 지정한 후 측정하였다. 통계분석은 비모수 검정법인 윌콕슨 순위 합 검정법을 이용하여 비교 분석하였다(제1종 오류수준=0.05). 비록 모든 부위에서 디지털 모형이 석고 모형보다 작은 것으로 분석되었으나(p<0.05), 임상적 허용 수치를 벗어나지 않았다.

메티마졸 투여 중인 갑상선기능항진증 환자에서 한약의 임상증상 완화효과에 대한 증례보고 (A Case Report on The Relieving Effect of Herbal Medicine on Clinical Symptoms in Patients with Hyperthyroidism Taking Methimazole)

  • 윤현자
    • 대한한의학방제학회지
    • /
    • 제31권3호
    • /
    • pp.203-213
    • /
    • 2023
  • 본 증례는 그레이브스병에 의한 갑상선기능항진증으로 진단된 환자에서 메티마졸 단독 투여에도 계속된 갑상선기능항진증의 증상치료를 위하여 한의 변증진단(辨證診斷) 과정을 통하여 심담허겁(心膽虛㥘)과 심화상염(心火上炎) 변증형(辨證形)을 도출하고 가미온담탕(加味溫膽湯)에 청심연자음(淸心蓮子飮)을 합방(合方)한 한약을 메티마졸과 병행투여 한 사례이다. 본 증례에서 한약이 메티마졸의 갑상선 호르몬 억제 효과는 계속 유지하면서 갑상선기능항진증 환자의 증상을 완화한 효과를 보여준 결과는 갑상선기능항진증 치료에 있어서 한약이 베타 차단제를 대체하여 메티마졸과 병행투여할 수 있는 약물로써 가능성이 있다는 것을 보여준다.

Characteristics and Socio-Demographic Distribution of Precarious Employment Among Korean Wage Workers: A Proposition of Multidimensional Approach Using a Summative Score

  • Seong-Uk Baek;Min-Seok Kim;Myeong-Hun Lim;Taeyeon Kim;Jin-Ha Yoon;Jong-Uk Won
    • Safety and Health at Work
    • /
    • 제14권4호
    • /
    • pp.476-482
    • /
    • 2023
  • Introduction: There is a growing global interest in the issue of precarious employment. We aimed to analyze the characteristics and socio-demographic distribution of precarious employment using a summative score approach. Methods: To operationalize precarious employment, we utilized data from the Korean Working Conditions Survey and focused on three distinct dimensions: employment insecurity, income inadequacy, and a lack of rights and protections. By constructing a summative scale ranging from -16 to 2, with lower scores indicating higher precariousness, we measured employment precariousness among Korean wage workers. To compare employment precariousness according to survey participant characteristics, we employed the Wilcoxon Rank Sum Test. Results: We analyzed a weighted number of 38,432 workers. The overall sample showed a median (Q1, Q3) summative scale score of -3 (-6, -1). The median summative score was lower for women compared to men (men: -2; women: -5; p < 0.001), as well as for young or older workers compared to middle-aged workers (young: -4; middle-aged: -2; older: -5; p < 0.001). Similarly, workers with lower educational levels (middle school or below: -8; high school: -5; college or above: -2; p < 0.001) and non-white collar workers (blue collar: -5; service/sales worker: -6; white collar: -2; p < 0.001) experienced higher levels of employment precariousness. Conclusion: Our findings indicate that certain vulnerable groups, such as women, young or older adults, workers with low educational attainment, and caregiving or low-skilled elementary workers, are disproportionately exposed to high employment precariousness. Active policy interventions are needed to improve the employment quality of vulnerable groups.

뼈 검사 영상과 골반 X선 영상의 결합 유용성 평가 (Evaluation of the combination of Bone Scan Image and Pelvic X-ray Image)

  • 이충운;유연욱;김용근;원우재
    • 핵의학기술
    • /
    • 제22권1호
    • /
    • pp.23-27
    • /
    • 2018
  • [목적] 뼈 검사는 골격계 질환에 대한 예민도와 높은 해상력의 핵의학 영상 검사이다. 본 연구는 추가적인 방사선피폭없이 뼈 검사 영상과 골반 X선 영상의 결합을 시행하고 영상의 해부학적 정보와 관용도를 증가시켜 환자 병변 진단에 도움이 되고자 한다. 2015년 11월에서 2016년 8월까지 본원에서 뼈 검사를 실시한 환자 중 골반 X선 촬영을 시행한 236명을 대상으로 진행하였다.(남자 64명, 여자 172명, 평균연령 $50.96{\pm}15.39$세) 검사장비는 감마카메라 Symbia Ecam(SIEMENS, Germany)을 사용하였고 디지털 엑스레이는 DRS-800(Listem, Korea)을 사용하였다. 영상의 결합 및 분석프로그램은 Osirix version 3.8.1(Osirix, USA), 통계프로그램은 Stata/SE 버전 14.0(StataCorp, USA)를 사용하였다. 환자에게 $^{99m}Tc-DPD$ 740 MBq을 정맥주사한 후 2~4시간이 지난 뒤에 검사를 진행하였다. 감마카메라 영상 획득 조건은 Matrix size $256{\times}1024$, Zoom 1.00, 검사 속도 17 cm/min로 하였다. 디지털 엑스레이는 Collimator size $14^{{\prime}{\prime}}{\times}17^{{\prime}{\prime}}$, 77 kVp(60~97kVp), 평균 30 mAs(20~48)로 전상장골극과 치골결합 사이 수직입사를 하였다. Osirix 상에서 골반 뼈의 윤곽 및 가상의점을 선택하여 결합하고 획득한 영상을 핵의학과 5년 이상 근무한 방사선사 3명에 의해 평가 되었으며, 모두 동일할 경우 일치, 하나라도 동일하지 않을 경우 불일치로 평가하였다. 전체 236명 중 일치하는 대상은 216명 (91.53%) 이다. 연령의 중위수 및 범위(최소값~최대값)는 일치하지 않는 그룹에서 67(46~81)세, 일치하는 그룹에서 52(22~87)세로, 일치하지 않는 그룹의 연령이 더 높은 것을 확인하였고, 두 군 간에 연령이 다른지 Wilcoxon rank-sum test를 수행해 본 결과, 통계적으로 유의하게 두 군 간에 나이가 차이나는 것을 확인할 수 있었다(p < 0.0001). 남자는 64명 중 60명(93.75%), 여자는 172명 중 156명(90.70%)가 일치하였고, 골반 병변이 없던 환자는 54명 중 54명(100.00%), 골반 병변이 있던 환자는 182명 중 162명(89.01%) 일치하였고, 골반 병변 여부에 따른 일치율은 통계적으로 유의한 차이를 보였다(p = 0.0094). 뼈 검사와 골반 X선 영상을 결합하는데 있어서 여러 가지 변수가 있을 수 있었고 환자의 연령과 골반병변이 영상의 결합에 일부 영향을 줄 수 있을 것으로 생각된다. 본 연구를 통하여 방사선 피폭 없이 소아의 골반 골육종 진단에 도움이 되리라 사료되고 이와 같은 영상의 결합 연구를 통해서 핵의학 영상발전에 도움이 될 것으로 기대된다.