• Title/Summary/Keyword: Width load

Search Result 1,040, Processing Time 0.031 seconds

Analysis, Design and Implementation of an Interleaved DC/DC Converter with Series-Connected Transformers

  • Lin, Bor-Ren;Chen, Chih-Chieh
    • Journal of Power Electronics
    • /
    • v.12 no.4
    • /
    • pp.643-653
    • /
    • 2012
  • An interleaved DC/DC converter with series-connected transformers is presented to implement the features of zero voltage switching (ZVS), load current sharing and ripple current reduction. The proposed converter includes two half-bridge converter cells connected in series to reduce the voltage stress of the switches at one-half of the input voltage. The output sides of the two converter cells with interleaved pulse-width modulation are connected in parallel to reduce the ripple current at the output capacitor and to achieve load current sharing. Therefore, the size of the output chokes and the capacitor can be reduced. The output capacitances of the MOSFETs and the resonant inductances are resonant at the transition instant to achieve ZVS turn-on. In addition, the switching losses on the power switches are reduced. Finally, experiments on a laboratory prototype (24V/40A) are provided to demonstrate the performance of the proposed converter.

Buckling and Limit Width-Thickness Ratios of Steel Columns under Compression at Elevated Temperatures (온도 상승에 따른 압축강재의 좌굴 및 한계 판폭두께비)

  • Kang, Seong-Deok;Kim, Jae-Uk;Choi, Hyun-Sik
    • Journal of Korean Association for Spatial Structures
    • /
    • v.12 no.3
    • /
    • pp.55-62
    • /
    • 2012
  • 본 연구는 온도 증가에 따른 압축을 받는 H형 강재의 플랜지와 웨브의 국부 및 전체좌굴응력 내화해석 프로그램 개발과 플랜지와 웨브가 항복파괴전에 국부좌굴이 일어나지 않을 한계 판폭두께비의 상관값을 구하는 프로그램을 개발하는 것이다. 고온에서의 강재의 응력-변형도 관계식은 EC3:Part 1.2를 근거로 하였으며, 비교, 검토를 위하여 영국 BS5950의 강재를 대상으로 온도 증가에 따른 압축을 받는 강재의 플랜지와 웨브의 파괴온도와 하중을 본 연구의 내화해석 프로그램으로 예측하였다. 본 연구는 좌굴 및 항복에 대한 내화해석 프로그램을 개발하는 것을 목적으로 하고 적용 예를 통하여 좌굴 및 한계 판폭두께비를 분석하고 개발 프로그램의 타당성을 검토하였다.

Area-Optimized Design of BICMOS Buffers (BICMOS 버퍼의 면적 최적 설계)

  • Lee, Heui-Deok;Han, Chul-Hi
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.27 no.10
    • /
    • pp.89-95
    • /
    • 1990
  • A model for bipolar-CMOS buffer design is presented which offers a guideline for determining device sizes based on speed and capacitive load. Closed-form solutions for area optimization are obtained assuming high level injection and channel velocity limitation. The solutions and circuit simulations show that the areas of BICMOS buffers are optimized by scaling the emitter length and the channel width approximately in proportion with capacitive load.

  • PDF

Simulation for the analysis of distortion and electrical characteristics of a two-dimensional BJT (2차원 BJT의 전기적 특성 및 왜곡 해석 시뮬레이션)

  • 이종화;신윤권
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.35D no.4
    • /
    • pp.84-92
    • /
    • 1998
  • A program was developed to analyze the electrical characteristics and harmonic distrotion in a two-dimensional silicon BJT. The finite difference equations of the small signal and its second and thired harmonics for basic semiconductor equations are formulated treating the nonlinearity and time dependence with Volterra series and Taylor series. The soluations for three sets of simultaneous equations were obtained sequantially by a decoupled iteration method and each set was solved by a modified Stone's algorithm. Distortion magins and ac parameters such as input impedance and current gains are calculated with frequency and load resistance as parameters. The distortion margin vs. load resistancecurves show cancellation minima when the pahse of output voltage shifts. It is shown that the distortionof small signal characteristics can be reduced by reducing the base width, increasing the emitter stripe length and reducing the collector epitaxial layer doping concentration in the silicon BJT structure. The simulation program called TRADAP can be used for the design and optimization of transistors and circuits as well as for the calculation of small signal and distortion solutions.

  • PDF

A Study for Structural Capacity Evaluation of Embedded Steel Plate Connected with Prestressed Concrete Beam to Build Large Space Educational Facilities (대공간 교육시설 축조를 위한 프리스트레스트 보에 사용되는 접합 강재의 성능평가에 대한 연구)

  • Lee, Kyoung-Hun
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.10 no.2
    • /
    • pp.1-7
    • /
    • 2011
  • An experimental study to evaluate structural capacity of an embedded plate connected with prestressed concrete beam was performed. Embedded steel plates and prestressed concrete beam were connected with stud-bolts at the ends of concrete beam specimens. About 1,000 kN concentrated load was applied at 450mm away from the end of beam specimen. A 3,000 kN capacity static Oil-jack was used to direct concentrated load. The maximum strain of stud-bolt recorded $90{\times}10^{-6}$(mm/mm) and wide width cracks were not founded. Any falling failures of concrete and large deformations were not founded either between steel plate and prestressed concrete specimen. As a result, construction performance can be improved using this embedded steel plate connection system apply to large space educational facilities.

Effect of Base Roughness of Footing on Settlement Characteristics of Footing (기초저면의 조도가 기초의 침하 특성에 미치는 영향)

  • Yoo, Nam-Jae;Kim, Young-Gil;Park, Byung-Soo
    • Journal of Industrial Technology
    • /
    • v.12
    • /
    • pp.15-23
    • /
    • 1992
  • This research is to investigate the effect of base roughness of footing on characteristics of load-settlement curve. Parametric experiments of small scaled model test were performed with changing the properties of base roughness of model footing; Gluing the vinyl, aluminum, sand paper, sand beneath the model footing surface. The width of model footing and relative density of soil foundation were also changed to investigate their effects on settlement characteristics of footing. The ultimate bearing capacity as well as the initial slope of load-settlement curve obtained from test results were compared with those from limit equilibrium methods proposed by Terzaghi, Hansen and Meyerhof. From test results, it was confirmed that the base roughness affected the failure mechanisms of showing different shapes of slip lines formed beneath the footing.

  • PDF

A Study on the Collapse Characteristics of Hat-shaped Members with Spot Welding under Axial Compression(II) (모자형 단면 점용접부재의 축방향 압궤특성에 관한 연구(II))

  • 차천석;양인영
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.17 no.5
    • /
    • pp.195-201
    • /
    • 2000
  • The fundamental spot welded sections of automobiles (hat-shaped and double hat-shaped sections) absorb most of the energy in a front impact collision. The sections of various thickness, shape and weld width on the flange lave been tested on axial impact crush load (Mass 40kg, Velocity 7.19m/sec) using a vertical air pressure crash est device Characteristics of impact collapse have been reviewed and a structure of optimal energy absorbing capacity is suggested.

  • PDF

Nonlinear finite element modeling of steel-sheathed cold-formed steel shear walls

  • Borzoo, Shahin;Ghaderi, Seyed Rasoul Mir;Mohebi, Saeed;Rahimzadeh, Ali
    • Steel and Composite Structures
    • /
    • v.22 no.1
    • /
    • pp.79-89
    • /
    • 2016
  • Cold formed steel shear panel is one of the main components to bearing lateral load in low and mid-rise cold formed steel structures. This paper uses finite element analysis to evaluate the stiffness, strength and failure mode at cold formed steel shear panels whit steel sheathing and nonlinear connections that are under monotonic loading. Two finite element models based on two experimental model whit different failure modes is constructed and verified. It includes analytical studies that investigate the effects of studs and steel sheathing thickness changes, fasteners spacing at panel edges, one or two sides steel sheathing and height-width ratio of wall on the lateral load capacity. Dominant failure modes include buckling of steel sheet, local buckling in boundary studs and sheet unzipping in the bottom half of the wall.

A Study on Synchronized AC Source Voltage Regulator of Voltage Fed Inverter using a Photovoltatic Effect

  • Hwang, Lak-Hoon;Lee, Chun-Sang;Kim, Jong-Lae;Jang, Byong-Gon
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.547-553
    • /
    • 1998
  • In this paper, we composed of utility interactive pv generation system of voltage source inverter, and represented uninterrutible power supply (UPS) equipment maintaining constant voltage, using a pulse width modulation(PWM) voltage fed inverter, as power source disconnection, voltage variation and output current variation with load variation. This system is driven by being synchronized voltage fed inverter and AC source, and in the steady state of power source charge battery connected to dc side with solar cell using a photovoltaic (PV) that it was so called constant voltage charge. In addition, better output waveform was generated because of PWM method, and it was proved to test by experiment maintained constant output voltage regardless of AC source disconnection, load variation, and voltage variation of AC power source.

  • PDF

Analysis, Design and Implementation of an Interleaved Single-Stage AC/DC ZVS Converters

  • Lin, Bor-Ren;Huang, Shih-Chuan
    • Journal of Power Electronics
    • /
    • v.12 no.2
    • /
    • pp.258-267
    • /
    • 2012
  • An interleaved single-stage AC/DC converter with a boost converter and an asymmetrical half-bridge topology is presented to achieve power factor correction, zero voltage switching (ZVS) and load voltage regulation. Asymmetric pulse-width modulation (PWM) is adopted to achieve ZVS turn-on for all of the switches and to increase circuit efficiency. Two ZVS half-bridge converters with interleaved PWM are connected in parallel to reduce the ripple current at input and output sides, to control the output voltage at a desired value and to achieve load current sharing. A center-tapped rectifier is adopted at the secondary side of the transformers to achieve full-wave rectification. The boost converter is operated in discontinuous conduction mode (DCM) to automatically draw a sinusoidal line current from an AC source with a high power factor and a low current distortion. Finally, a 240W converter with the proposed topology has been implemented to verify the performance and feasibility of the proposed converter.