• Title/Summary/Keyword: Whole-body

Search Result 2,789, Processing Time 0.043 seconds

Expression of Jun and p53 Genes from the Brain of Rats Irradiated with $^{60}Co{\gamma}$-ray (감마선 조사에 의한 뇌조직의 Jun 및 p53유전자 발현)

  • Kim Yong Seok;Woo Chong Kyu;Lee Yong Sung;Koh Jai Kyung;Chun Ha Chung;Lee Myung Za
    • Radiation Oncology Journal
    • /
    • v.14 no.4
    • /
    • pp.265-279
    • /
    • 1996
  • Damage produced by radiation elicits a complex response in mammalian cells, including growth rate changes and the induction of a variety of genes associated with growth control and apoptosis. At doses of 10,000 cGy or greater, the exposed individual was killed in a matter of minutes to a couple of days, with symptoms consistent with pathology of the central nervous system(CNS) including degenerative changes. The nature of the damage in irradiated cells underlies the unique hazards of ionizing radiation. Radiation injury to CNS is a rare event in clinical medicine, but it is catastrophic for the patient in whom it occurs. The incidence of cerebral necrosis has been reported as high as 16% for doses greater than 6,000 cGy. In this study, the effect of radiation on brain tissue was studied in vivo. Jun and p53 genes in the rat brain were induced by whole body irradiation of rat with 600Co in doses between 1 Gy and 100 Gy and analyzed for expression of jun and p53 genes at the postirradiation time up to 6 hours. Northern analyses were done using 1.8 Kb & 0.8 Kb-pGEM-2-JUN/Eco RI/Pst I fragments, 2.0 Kb-php53B/Bam HI fragment and ,1.1 Kb-pBluescript SK--ACTIN/Eco RI fragment as the digoxigenin or [${\alpha}^{32}P$] dCTPlabeled probes for Jun, p53 and ${\beta}$-actin genes, respectively. Jun gene seemed to be expressed near the threshold levels in 1 hour after irradiation of $^{60}$Co in dose less than 1 Gy and was expressed in maximum at 1 hour after irradiation of $^{60}$Co in dose of 30 Gy. Jun was expressed increasingly with time until 5 or 6 hours after irradiation of $^{60}$Co in doses of 1 Gy and 10 Gy. After irradiation of $^{60}$Co in dose between 20 Gr and 100 Gy, the expression of Jun was however increased to peak in 2 hours and decreased thereafter. p53 gene in this study also seemed to be expressed near the threshold levels in 1 hour after irradiation of $^{60}$Co in dose less than 1 Gy and was expressed in maximum at 6 hours after irradiation of $^{60}$Co in dose of 1 Gy, p53 was expressed increasingly with time until 5 or 6 hours after irradiation of $^{60}$Co in dose between 1 Gy and 40 Gy. After irradiation of $^{60}$Co in doses of 50 Gy and 100 Gy, the expression of p53 was however increased to peak in 2 hours and decreased thereafter. The expression of Jun and p53 genes was not correlative in the brain tissue from rats. It seemed to be very important for the establishment of the optimum conditions for the animal studies relevant to the responses of genes inducible on DNA damage to ionizing radiation in mammalian cells. But there are many limitations to the animal studies such as the ununiform patterns of gene expression from the tissue because of its complex compositions. It is necessary to overcome the limitations for development of in situ Northern analysis.

  • PDF

Study on Measurements of the Mandible BMD According to the ROI Variation (관심영역 변화에 따른 하악골 골밀도 측정에 대한 연구)

  • Tak, Jeong-Nam
    • Journal of radiological science and technology
    • /
    • v.32 no.3
    • /
    • pp.271-276
    • /
    • 2009
  • The aim of this study was to evaluate the effect of Bone Mineral Density(BMD) at mandible. So, we studied how to measure the BMD at mandible using DEXA(Dual energy X-ray absorptiometry, DEXA) by Horner er al (1996) and knew reproducibility of the measurements. Thirty-five patients (13 men, 22 women, mean age : 25.4 years) were examined using the GE Lunar Prodigy Advance(LUNAR Corporation, madison, USA). They were examined in Semiprone position of their body and true lateral position of their mandible selected the Lumbar lateral mode. We used the custom mode in analysis when ROI (area $30{\times}2.5\;mm^2$). Three ROIs ($30{\times}2.5\;mm^2$, $50{\times}2.5\;mm^2$, $20{\times}2.5\;mm^2$) were located each at the two different sites of the mandible (angle of mandible and mental symphysis) and BMD was measured. Differences in BMD measurement was statistically compared according to the size and location of ROI. BMD was $1.320{\pm}0.358g/cm^3$ in men and was $1.152{\pm}0.340g/cm^3$ in women. BMD at the angle of mandible was $1.201{\pm}0.361g/cm^3$ in men and was $1.025{\pm}0.377g/cm^3$ in women. BMD of men at the mental symphysis was $1.434{\pm}0.341g/cm^3$ and that of women was $1.19{\pm}0.358g/cm^3$. With the ROI of $20{\times}2.5\;mm^2$, BMD was $1.262{\pm}0.384g/cm^3$ in men and was $1.113{\pm}0.357g/cm^3$ in women. With the ROI of $50{\times}2.5\;mm^2$, BMD of men was $1.320{\pm}0.358g/cm^3$ and that of women was $1.129{\pm}0.340g/cm^3$. There was a statistically significant difference of BMD according to the size and location of ROI. When measuring mandible BMD, there are good for increasing ROI and locate between ramus and mental symphysis. Especially following exam, refer to same size and location with fore exam. According to study which measure mandible BMD, It's correct to measure better a portion of mandible then whole of BMD. Using DEXA protocol is studied good for the additional study to compare the BMD at mandible. Later date, It will be good for measurement value in implant and bone graft quantitatively. Using DEXA method gain BMD threshold value in korean.

  • PDF

Effects of Probiotics as an Alternative for Antibiotics on Growth Performance, Nutrient Digestibility, Noxious Gas Emission and Fecal Microbial Population in Growing Piglets (항생제 대체 생균제가 자돈의 생산성,영양소 이용률, 유해가스 발생량 및 분내 미생물 수에 미치는 영향)

  • Kim, Jong-Duk;Chung, Heung-Woo;Shim, Kum-Seob;Park, Seung-Young;Ju, Jong-Cheol;Song, Jae-Jun;Lee, Kyung-Ho;Park, Joong-Kook;Park, Do-Yun;Kim, Chang-Hyun
    • Korean Journal of Organic Agriculture
    • /
    • v.18 no.4
    • /
    • pp.527-539
    • /
    • 2010
  • This study was conducted to determine the effect of probiotics as an alternative for antibiotics on growth performance, nutrient digestibility, noxious gas emission and fecal microbial population in growing piglets. A total of 96 piglets ($22.5{\pm}1.3$kg average body weight) were allotted to 3 different treatment groups and replicated 4 times with 8 piglets per replicate in randomized complete block design. Treatments were T1) (Control, basal diet+0.2% antibiotics), T2) 0.2% probiotics complex and T3) 0.3% Bacillus probiotics. During the whole experiment period, there were no differences (p>0.05) in average daily gain (ADG), average daily feed intake (ADFI) and feed efficiency. However, digestibility of dry matter, crude protein, ether extract, nitrogen free extract and crude ash were showed higher in probiotics groups (T2 and T3) than those of control. In noxious gas emission, ammonia, amine, hydrogen sulfide and mercaptan were significantly (p<0.05) reduced in T2 and T3 treatments compared to those in control. Moisture content of feces was not significantly different among treatments. The colony forming units (CFU) of total bacteria, E. coli and thermoduric bacteria in feces were significantly different among treatments. The CFU of total bacteria, E. coli and thermoduric bacteria in T3 treatment were reduced by feeding probiotics B. From this study, we suggest that probiotics A and B are likely able to improve the growth performance and nutrients digestibility, reduce noxious gas emission and change the fecal microbial composition in growing piglets.

The Differentiation of Benign from Maligant Soft Tissue Lesions using FDG-PET: Comparison between Semi-quantitative Indices (FDG-PET을 이용한 악성과 양성 연부조직 병변의 감별: 반정량적 지표간의 비교)

  • Choi, Joon-Young;Lee, Kyung-Han;Choe, Yearn-Seong;Choi, Yong;Kim, Sang-Eun;Seo, Jai-Gon;Kim, Byung-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.31 no.1
    • /
    • pp.90-101
    • /
    • 1997
  • The purpose of this study is to evaluate the diagnostic accuracy of various quantitative indices for the differentiation of benign from malignant primary soft tissue tumors by FDG-PET. A series of 32 patients with a variety of histologically or clinically confirmed benign (20) or malignant (12) soft tissue lesions were evaluated with emission whole body (5min/bed position) PET after injection of [$^{18}F$]FDG. Regional 20min transmission scan for the attenuation correction and calculation of SUV was performed in 16 patients (10 benign, 6malignant) followed by dynamic acquisition for 56min. Postinjection transmission scan for the attenuation correction and calculation of SUV was executed in the other 16 patients (10 benign, 6 malignant). The following indices were obtained. the peak and average SUV (pSUV, aSUV) of lesions, tumor-to-background ratio acquired at images of 51 min p.i. ($TBR_{51}$), tumor-to-background ratio of areas under time-activity curves ($TBR_{area}$) and the ratio between the activities of tumor ROI at 51 min p. i. and at the time which background ROI reaches maximum activity on the time-activity curves ($T_{51}/T_{max}$). The pSUV, aSUV, $TBR_{51}$, and $TBR_{area}$ in malignant lesions were significantly higher than those in benign lesions. We set the cut-off values of pSUV, aSUV, $TBR_{51},\;TBR_{area}$ and $T_{51}/T_{max}$ for the differentiation of benign and malignant lesions at 3.5, 2.8, 5.1, 4.3 and 1.55, respectively. The sensitivity, specificity and accuracy were 91.7%, 80.0%, 84.4% by pSUV and aSUV, 83.3%, 85.0%, 84.4% by $TBR_{51}$, 83.3%, 100%, 93.8% by $TBR_{area}$ and 66.7%, 70.0%, 68.8% by $T_{51}/T_{max}$. The time-activity curves did not give additional information compared to SUV or TBR. The one false negative was a case with low-grade fibrosarcoma and all four false positives were cases with inflammatory change on histology. The visual, analysis of FDG-PET also detected the metastatic lesions in malignant cases with comparable accuracy In conclusion, all pSUV, aSUV, $TBR_{51}$, and $TBR_{area}$ are useful metabolic semi-quantitative indices with good accuracy for the differentiation of benign from malignant soft-tissue lesions.

  • PDF

Improved Clinical Staging of Esophageal Cancer with FDG-PET (양전자단층촬영술을 이용한 식도암의 병기 결정 성적 향상)

  • Kim, Young-Hwan;Choi, Joon-Young;Lee, Kyug-Soo;Choi, Yong-Soo;Lee, Eun-Jeong;Chung, Hyun-Woo;Lee, Su-Jin;Lee, Kyung-Han;Shim, Young-Mog;Kim, Byung-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.4
    • /
    • pp.282-287
    • /
    • 2004
  • Purpose: Since preoperative staging in esophageal cancer is important in both therapy and prognosis, there had been many efforts to improve its accuracy. Recent studies indicate that whole body FDG-PET has high sensitivity in detection of metastasis in esophageal cancer. Therefore, we added FDG-PET to other conventional methods in staging esophageal cancer to evaluate the usefulness of this method. Materials & Methods: Subjects were 142 esophageal cancer patients (average $62.3{\pm}8.3$ yrs) who received CT and PET just before operation. First, we compared N stage and M stage of the CT or PET with those of the post-operative results. Then we compared the stage according to the EUS (T stage) and CT (N and M stage) or SUS (T stage) and CT & PET (N and M stage) to that according to the post-operative results. Results: Among 142 patients, surgical staging of 69 were N0 and 73 were N1. In M staging, 128 were M0 and 14 were M1. Sensitivity, specificity, and accuracy of N staging were 35.6%, 89.9%, 62.0% with CT and 58.9%, 71.0%, 64.7% with PET, respectively. In M staging, 14.3%, 96.9%, 88.7% with CT and 50.0%, 94.5%, 90.1%, with PET, respectively. The concordances of [EUS+CT] and [EUS+CT+PET] with post-operative results were 41.2% and 54.6%, respectively and there was significant improvement of staging with additional PET scan (p<0.005). Conclusion: The concordance of [EUS+CT+PET] with post-operative result was significantly increased compared to that of [EUS+CT]. Thus, the addition of FDG-PET with other conventional methods may enable more accurate preoperative staging.

A Comparative Analysis of Standard Uptake Value Using the Recovery Coefficient Before and After Correcting Partial Volume Effect (부분 체적 효과에서 회복 계수를 이용한 보정 전과 후 SUV의 비교 분석)

  • Ko, Hyun-Soo;Park, Soon-Ki;Choi, Jae-Min;Kim, Jung-Sun;Jung, Woo-Young
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.10-16
    • /
    • 2011
  • Purpose: The partial volume effect occurs because of limit of the spatial resolution. It makes partial loss of intensity and causes SUV to be lower than it should actually be. So the purpose of this study is to calculate recovery coefficient for correcting PVE from phantom study and to compare before and after SUV correction applying to PET/CT examination. Materials and Methods: The flangeless Esser PET phantom consisting of four hot cylinders was used for this study. All of the hot cylinders were filled with FDG solution of 20.72 MBq per 1000 ml, and the phantom background was filled with FDG solution of different concentrations (33.30, 22.20, 16.65 MBq per 6440 ml) to yield H/B ratios of around 4:1, 6:1 and 8:1. Using the Biograph Truepoint 40(SIEMENS, Germany), we applied recovery coefficient method to 30 patients who were diagnosed with lung cancer after PET/CT exam. And then we analyzed and compared SUV before and after correcting partial volume effect. Results: The smaller the diameter of hot cylinder becomes, the more recovery coefficient decreased. When we applied recovery coefficient to clinical patients and compared SUV before and after correcting PVE, before the correction all lesions gave an average max SUV of 7.83. And after the correction, the average max SUV increases to 10.31. The differences in the max SUV between before and after correction were analyzed by paired t test. As a result, there were statistically significant differences (t=7.21, p=0.000). Conclusion: The SUV for quantification should be measured precisely to give consistent information of tumor uptake. But PVE is one of factors that causes SUV to be lower and to be underestimated. We can correct this PVE and calculate corrected SUV using the recovery coefficient from phantom study. And if we apply this correction method to clinical patients, we can finally assess and provide quantitative analysis more accurately.

  • PDF

Quality Control of Upper Gastrointestinal Series(UGIS) by The Image Quality Evaluation Table of Korea and Japan (한.일 화질평가표에 의한 우리나라 위장조영검사의 품질관리)

  • Oh, Hye-Kyong;Kim, Jung-Min;Kim, Chang-Gyun;Park, Young-Seon;Seon, Jong-Ryul;Choi, In-Seok
    • Journal of radiological science and technology
    • /
    • v.34 no.4
    • /
    • pp.277-285
    • /
    • 2011
  • To determine the quality control of UGIS, we acquired 105 patients sampling image at 21 general screening centers. The results of image quality evaluation table containing two countries's UGIS showed that the mean of image qualified education table of our country was 73.3 and the standard error was 4.49; In addition, 19 organizations of 21 general screening centers were given appropriate judgement. The average of image qualified education table of Japan was 58 and the standard error was 4.45. Only 8 organizations were given appropriate judgement. Although we made the image quality evaluation tables with same images, there were many differences in the result of two tables. We figured out the problem about the description of whole stomach and photograph skills. Furthermore, we analysed the situation of the UGIS at each general screening center with the acquired images. The biggest problem of the UGIS of our country was that the procedures were performed without clear medical methods. Methods of UGIS were different at every 21 general screening centers, and most of them did not take exam of anterior surface of stomach of the UGIS. In addition, some general screening centers did not include mucosal relief method or esophagography which is required to include in the image qualified education table of our country. Because polisography is used in the same body position, the problem occured about indiscreet exposure dose of patients. Therefore we have to make an effort to get X-ray images which have enough diagnosis information by the quality control of UGIS.

The Effect of Ginkgo Biloba Extract on Radiosensitivity of Mouse Skin and Jejunal Crypt (Ginkgo Biloba Extract가 마우스 피부 및 공장 소낭선의 방사선감수성에 미치는 영향)

  • Shin, Kyung-Hwan;Ha, Sung-Whan
    • Radiation Oncology Journal
    • /
    • v.16 no.2
    • /
    • pp.107-114
    • /
    • 1998
  • Purpose : Ginkgo biloba extract(GBE) is known to increase the peripheral blood circulation. This study was designed to evaluate the effect of GBE on the acute normal tissue radiation reaction. Materials and Methods : mice were divided into two groups, radiation alone and two doses GBE plus radiation, for both acute skin reaction and jejunal crypt assay. GBE was given i.p. one hour before irradiation with priming dose given one day earlier. Thirty to Fifty Gy for acute skin reaction and 11 to 14 Gy for jejunal crypt were irradiated to right hind leg and whole body, respectively. Results : Radiation doses($RD_{50}$) for Peak skin score of 2.0 were 44.2Gy (40.6-48.2Gy) for radiation alone and 44.4Gy(41.6-47.4Gy) for two doses GBE plus radiation, showing no effect of GBE on acute radiation skin damage. The numbers of regenerating jejunal crypts per circumference were also almost the same for each radiation dose level(p=0.57-0.94), and the mean lethal doses($D_o$) were 1.800y(1.57-2.09Gy) for radiation alone and 1.88Gy(1.65-2.18Gy) for two doses GBE plus radiation, indicating no effect of GBE on jejunal crypt cell survival after radiation. Conclusion : GBE doesn't increase acute normal tissue radiation reaction in this model system. As GBE was verified to enhance radiation effect on tumor, high therapeutic gain is expected when GBE is combined with radiation therapy.

  • PDF

Bone Marrow Scintigraphy with Antigranulocyte Antibody in Multiple Myeloma: Comparison with Simple Radiography and Bone Scintigraphy (항과립구 항체 골수스캔을 이용한 다발성 골수종 병변의 평가: 단순골X-선점사 및 골스캔과의 비교)

  • Kim, Dong-Hwan;Lee, Jae-Tae;Baek, Jin-Ho;Jung, Jin-Tae;Hyun, Dong-Woo;Chun, Kyung-Ah;Lee, Young-Hak;Sohn, Sang-Kyun;Song, Hong-Seok;Lee, Kyu-Bo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.4
    • /
    • pp.354-364
    • /
    • 1998
  • Purpose: Simple X-ray study and bone scan have limitations for early diagnosis of bone or bone marrow lesions in multiple myeloma. The purpose of this study was to evaluate the diagnostic usefulness of bone marrow immunoscintigraphy using anti-granulocyte monoclonal antibody for the evaluation of bone involvement in multiple myeloma. Materials and Methods: In 22 patients (Male: 15, Female: 7) with multiple myeloma, we performed whole-body immunoscintigraphy using $^{99m}Tc$-labelled antigranulocyte antibody (BW 250/183, Scintimum $Granulozyt^{(R)}$ CIS, France) and compared the findings with those of simple bone radiography and $^{99m}Tc$-MDP bone scan. Abnormal findings in bone marrow scintigraphy were, considered to be present in case of expansion of peripheral bone marrow or focal photon defect in axial bones. Results: Marrow expansion was noted in 15 of 22 patients (68%). Focal photon defects were found in 18 patients (82%). While one (33%) of 3 patients with Stage II disease showed focal defects in bone marrow scan, abnormal focal defects were observed in 17 of 19 (90%) patients with Stage III. Among 124 focal abnormal sites which were observed in bone marrow scan, bone scan or simple bone radiography, bone marrow scan detected 92 sites (74%), whereas 82 sites (66%) were observed in simple bone radiography(58 sites, 47%) or bone scan(40 sites, 32%). Fifty-one (41%) out of 124 bone lesions were detected by bone marrow scan only, and located mostly in thoracolumbar spine. Conclusion: Bone marrow scan using $^{99m}Tc$-labelled antigranulocyte antibody seems to be a more sensitive procedure for the detection of pathologic bone lesions than simple bone X-ray or bone scan in patients with multiple myeloma.

  • PDF

Is $^{99m}Tc$-MDP Mammoscintigraphy Useful in Patients with Breast Mass Lesions? ($^{99m}Tc$-MDP 유방 스캔은 유방 종괴의 감별진단에 임상적인 유용성이 있는가?)

  • Park, Seok-Gun;Lee, Yeon-Hee;Rhyu, Jin-Woo;You, Sun-Mee
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.2
    • /
    • pp.151-160
    • /
    • 1998
  • Purpose: Piccolo et al. advocated the usefulness of $^{99m}Tc$-MDP breast scan in differential diagnosis of breast mass with high accuracy. But there are little or no follow-up studies about it as we know. We studied $^{99m}Tc$-MDP uptake pattern and lesion/background ratio in patients complaining palpable breast lesions to evaluate the clinical usefulness of $^{99m}Tc$-MDP scan. Materials and Methods: Total 34 patients were studied with physical examination, mammo-gram and $^{99m}Tc$-MDP scan prospectively. Anteroposterior and both lateral view of breast were obtained 5 minutes after iv injection of 740 MBq $^{99m}Tc$-MDP. Breast uptake pattern of $^{99m}Tc$-MDP was analyzed by a grade system: 0=no uptake, grade 1=bilateral diffuse uptake, grade 2=asymmetric faint uptake, grade 3=focal hot uptake. 20 cases were pathologically confirmed by excision biopsy or aspiration biopsy. 14 cases were normal in physical examination and mammogram. Results: Pathologic results showed 7 carcinomas, 6 benign solid tumors, and 7 fibrocystic changes. Grade 3 pattern of $^{99m}Tc$-MDP uptake was noted in 4/7 carcinomas, 3/6 benign solid tumors, and 1/7 fibrocystic changes. Grade 2 pattern was 217, 0/7, 3/7 respectively. The average L/B ratio was 1.66 in carcinomas, 1.68 in benign solid masses, 1.20 in fibrocystic diseases, 1.05 in normal patients. L/B ratio was higher in carcinoma and benign mass groups than in fibrocystic change and normal control groups(p=0.005). But there was no statistical difference between L/B ratio of malignant mass group and benign mass group. Conclusion: $^{99m}Tc$-MDP scan is not suitable to routine clinical use for breast mass diagnosis. It might be used in limited conditions when whole body bone scan is planned.

  • PDF