• 제목/요약/키워드: Whole body scan

검색결과 180건 처리시간 0.024초

갑상선암의 방사성옥소 치료 후 전신 스캔에서 비타민C 용액을 이용한 식도의 위양성 병소 제거에 대한 고찰 (An Elimination of False-Positive I-131 Sites in Esophagus for Thyroid Carcinoma; Using Water with Vitamin C Dissolved)

  • 이승재;박훈희;안샤론;조석원;최영숙;조응혁;김재삼;이창호
    • 핵의학기술
    • /
    • 제12권1호
    • /
    • pp.49-56
    • /
    • 2008
  • Purpose: Whole body imaging with radioiodine can detect functioning metastases. Non-physiologic I-131 uptake detected on images usually is interpreted as suggesting functioning thyroid metastases. However, extra-thyroidal I-131 accumulation does not always imply thyroid cancer metastases and has been reported in many circumstances. In order to avoid unnecessary therapeutic interventions it is important to distinguish false-positive sites of I-131 localization. We study here to remove false-positive sites around esophagus region on I-131 whole body imaging in patients who were administrated thyroidectomy. Materials and Methods: From April to August in 2007, we had the patients who had visited our department after they received thyroidectomy due to thyroid cancer. They were given I-131, and performed radioiodine body scan after 41 to 50 hours. Patients were whole-body-scanned for the speed of 8 cm per minute. After that, we took anterior and posterior static images around the patients' neck measured by 300 thousand counts per image. We selected 44 patients who had hot spots around neck region, we divided the patients into two groups. One group was given 0.5 L of water and the other group was given 0.5 L of water with 1 g of Vitamin C dissolved. The patients were asked to drink the fluid for one minute in sitting position and after that, we measured 300 kilo counts per image again. We compared prior anterior, posterior static images with anterior, posterior images after the patients had water or water that Vitamin C resolved. Results: In using water, both observer 1 and 2 interpreted 6 patients were washed out. In the water with Vitamin C resolved, observer 1 and 2 interpreted 9 and 8 patients were washed out. Observer 1 and 2 interpreted 6 and 5 patients had 'indeterminate' when they used water. Both observer 1 and 2 interpreted 6 patients had 'indeterminate' when they used water with Vitamin C resolved. When they used water, observer 1 interpreted 10 patients had 'unchanged' and observer 2 interpreted 11 patients had 'unchanged'. Differently, when they used water with vitamin C resolved, observer1 had 8 patients having 'unchanged'and observer 2 had 9. Conclusion: As a result, by making patients drink 0.5 liter of water which has vitamin C resolved helped getting rid of false-positive sites in esophagus. Therefore, based on this study, we believe that drinking water with vitamin C dissolved is very in terms of reducing false-positive hot spot around the esophagus for the iodine-131 whole body scan.

  • PDF

안구 내 종양의 진단에 있어서 F-18-FDG PET의 유용성과 검사 방법의 영향 (The Usefulness of F-18-FDG PET and The Effect of Scan Protocol in Diagnosis of Intraocular Tumors)

  • 이재성;양원일;김병일;최창운;임상무;이태원;신민경;홍성운
    • 대한핵의학회지
    • /
    • 제33권5호
    • /
    • pp.439-451
    • /
    • 1999
  • 목적: 안구 내 종양의 치료계획에 있어서 악성여부의 결정은 매우 중요하다. 하지만 안구 내 종양의 생검은 시력의 손상을 가져오므로 임상적으로 권장할 수 없는 방법이다. 저자들은 안구 네 종양의 악성 여부를 진단하는 데 있어서 F-18-FDG PET의 유용성과 검사 방법이 결과에 미치는 영향에 대해 연구하였다. 대상 및 방법: 임상적으로 악성 안구 내 종양이 의심되는 13명의 환자(15병소)를 대상으로 F-18-FDG PET 스캔을 시행하였다. 세 명은 양성의 병소를 가지고 있었고(망막 박리, 맥락막 삼출, 맥락막출혈) 열 명을 열두 개의 악성 병소를 가지고 있었다(흑색종 3, 망막아종 7, 전이암 2). 양성 병소들과 악성 병소들의 크기는 각각 $164{\pm}85mm^3$$598{\pm}718mm^3$이었다. 영상은 GE Advance PET 스캐너(전체반값두께 4.6 mm)를 이용하여 얻었다. 각각의 영상에 대해 매트릭스 크기를 바꾸어 가면서($256{\times}256$$128{\times}128$) 감쇠보정을 하거나 하지 않는 두 가지방법으로 재구성하여 재구성 방법에 의한 영향을 비교하였다. 여덟 명의 환자(양성 3, 악성 병소 6)에서 추가로 전신스캔을 시행하였다. 육안 판독 후 반정량적으로 분석하여 표준섭취계수를 구하여 분석하였다. 결과: 치료하지 않은 악성 병소는 모두 진단할 수 있었고 양성 병소는 육안적으로 관찰되지 않았다. 10개의 악성 병소들의 픽셀당 최대 표준섭취 계수는 $2.64{\pm}0.57g/ml$로 한 예를 제외하고는 모두 2.0 g/ml보다 높았다. 종양의 크기와 표준섭취계수는 통계적인 상관관계가 없었다. 전신스캔에서는 두개의 $1000 mm^3$ 보다 큰 악성 병소는 높은 섭취를 보였으나 중간 크기의 병소들은 희미하게 관찰되었고 $100 mm^3$ 이하의 병소 두 개는 관찰되지 않았다. 결론: F-18-FDG PET는 안구 내 악성 종양의 진단에 있어서 높은 예민도를 보여 주었다. 악성 종양은 모두 육안적으로 진단할 수 있었다. 작은 크기의 안구 내 종양을 진단하기 위해서는 전신스캔은 예민도가 낮아 적당하지 않고 스캔시간을 충분히 길게 하여 안구 국소촬영을 할 필요가 있다. 영상은 $128{\times}128$ 매트릭스보다 $256{\times}256$ 매트릭스로 재구성하는 것이 좋다.

  • PDF

한국인 20대 청년 인체분절의 관성특성에 관한 연구 (Biodynamic Characteristics of Korean Male in Twenties-Mass, Center of Mass and Moment of Inertia Characteristics of Body Segments)

  • 이영신;임현균;김철중
    • 대한기계학회논문집
    • /
    • 제18권8호
    • /
    • pp.1952-1966
    • /
    • 1994
  • The body segment parameters of twelve young male Korean were measured to compare with the results of foreign cadaver studies. A human body was assumed to have fourteen body segments. The mass of each segment was measured with a water immersion test and the mass center of a segment was determined on the balance platform by changing postures. In the case of Korean, because of the difference in body proportion, the mass center of whole-body is located further from the distal end of head(Korean : 44.9% vs. Caucasian : 41.2%), and the mass center of each segment also located in different proportional locations. The existing regression equations, which can estimate segment mass based upon the anthropometric dimensions, estimates segment mass (the mass of shank) for Korean with 13% error. Therefore, it is not recommended to estimate the mass, and the moment of inertia of body segment of Korean based on the existing equations. However, the density information of body constituents was similar enough to apply it to Korean density. It was validated by the comparison between the results of the direct immersion method and 3-dimensional volume reconstruction of segment form the cross sectional images of CT-scan. The average body density measured form twelve subjects was $1.035{\;}kg/m^3$ and showed deceasing trendency.

급성(急性) 신부전(腎不全)이 동반(同伴)된 근양사(筋壤死)에 있어서의 $^{99m}Tc$-MDP 골주사(骨走査) ($^{99m}Tc$-MDP Bone Scan in the Cases of Muscle Necrosis Associated with Acute Renal Failure)

  • 문희범;한진석;김삼용;조보연;이정상;고창순;조경삼
    • 대한핵의학회지
    • /
    • 제14권2호
    • /
    • pp.61-66
    • /
    • 1980
  • We studied four patients with muscle necrosis associated with acute renal failure to evaluate the diagnostic value of the bone scan in this disease. The illness followed carbon monoxide poisoning in two patients, acute physical exertion in one and contaminated intramuscular injection in the other. Whole-body rectilinear bone scans using technetium 99m-methyldiphosphonate were done. In all patients, increased muscle labelling at the regions of suspected muscle injury was showed, and in one, it was after normalization of serum muscle enzyme levels. In one patient, the bone scan was rechecked 8 months later and showed no residual abnormality. Above all, the site and precise extent of muscle injury could be detected and the degree of muscle labelling seemed to correlate with the severy of muscle injury. These findings suggest that isotope scanning may be useful in the diagnosis of patients with acute muscle necrosis.

  • PDF

Zoom-in X-ray Micro Tomography System

  • Chun, In-Kon;Lee, Sang-Chul;Park, Jeong-Jin;Cho, Min-Hyoung;Lee, Soo-Yeol
    • 대한의용생체공학회:의공학회지
    • /
    • 제26권5호
    • /
    • pp.295-300
    • /
    • 2005
  • We introduce an x-ray micro tomography system capable of high resolution imaging of a local region inside a small animal. By combining two kinds of projection data, one from a full field-of-view (FOV) scan of the whole body and the other from a limited FOV scan of the region of interest, we have obtained zoomed-in images of the region of interest without any contrast a nomalies. We have integrated a micro tomography system using a micro-focus x-ray source, a $1248\times1248$ flat-panel x-ray detector, and a precision scan mechanism. Using the cross-sectional images taken with the zoom-in micro tomography system, we measured trabecular thicknesses of femur bones in postmortem rats. To compensate the limited spatial resolution in the zoom-in micro tomography images, we used the fuzzy distance transform for the calculation of the trabecular thickness. To validate the trabecular thickness measurement with the zoom-in micro tomography images, we compared the measurement results with the ones obtained from the conventional micro tomography images of the extracted bone samples.

부갑상선 암종에 의해 발생한 갈색 종양: $^{99m}Tc-MIBI$ 스캔 소견 (증례 보고) (Brown Tumors Due to Parathyroid Carcinoma; $^{99m}Tc-MIBI$ Scan Findings (Case Report))

  • 김수지;윤석남;김병석;정윤석;박찬희
    • 대한핵의학회지
    • /
    • 제31권3호
    • /
    • pp.395-398
    • /
    • 1997
  • 갈색 종양 (brown tumor or osteitis cystica fibrosa)은 일차성 또는 이차성 부갑상선 기능항진증의 골소견 중 하나이다. 부갑상선 질환이 의심될 때에 과거에는 $^{201}TI/^{99m}Tc$ 감영 스캔이 가장 많이 이용되는 비침습적 방법 중 하나였으나, 근래에는 $^{99m}Tc-MIBI$를 이용한 핵의학 영상이 더 널리 사용되고 있다. $^{99m}Tc-MIBI$의 종양 섭취에는 혈류의 증가, 세포 대사 및 미토콘드리아의 활동성이 관계된다고 보고되었지만, 갈색 종양에의 $^{99m}Tc-MIBI$의 섭취기전에 대해서는 거의 알려져 있지 않다. 저자들은 이전에 중족골의 거대 세포종 (Giant cell tumor)으로 오진하였던 환자에서, $^{99m}Tc-MIBI$스캔상 갈색 종양이 의심되었고, 후에 수술을 통해 부갑상선 암종 (Parathyroid carcinoma)이 확인되었던 1예를 보고하고자 한다.

  • PDF

폐소공포증 환자의 핵의학 영상검사에 관한 연구 (Study of Nuclear medical imaging tests patient of Claustrophobia)

  • 강용길;홍진웅;양한준;박성수;이귀원;김긍식
    • 대한디지털의료영상학회논문지
    • /
    • 제15권1호
    • /
    • pp.55-59
    • /
    • 2013
  • Patients who had claustrophobia tend to feel fear when they were scanned by an MRI, CT, PET-CT, or using a gamma camera scan. In this paper, claustrophobic patients were tested to find effective ways by changing patient's positions. For this paper, PET-CT scan in patients who had claustrophobia were used in the prone position. Prone position helped to maintain stable position and to get a h0igh quality of inspection without failure. Thus, as claustrophobic patients were requested taking prone position, they could feel comfortable. In a confined space, prone position for the claustrophobic patients who had a fear of the PET-CT examination would be expected to reduce the failure rate of inspection.

  • PDF

18F-FDG Whole Body PET/CT 수검자의 거리별 선량 변화에 따른 방사선 작업종사자의 유효선량 고찰: 환자 고유특성 및 응대시간 측면 (The Consideration of nuclear medicine technologist's occupational dose from patient who are undergoing 18F-FDG Whole body PET/CT : Aspect of specific characteristic of patient and contact time with patient)

  • 김성환;류재광;고현수
    • 핵의학기술
    • /
    • 제22권1호
    • /
    • pp.67-75
    • /
    • 2018
  • 방사선 안전에 대한 관심과 염려가 전 세계적으로 점차 증가되고 있는 가운데, 의료 실무 현장에 종사하는 방사선 작업종사자의 외부피폭 관리 또한 중요한 이슈로 부각되고 있다. 특히, $^{18}F-FDG$WholeBodyPET/CT검사의 경우 높은 에너지의 방사성동위원소를 사용하므로 검사자의 피폭선량 저감화에 더욱 관심을 기울여야 한다. 따라서, 본 연구는 $^{18}F-FDG$ Whole Body PET/CT 수검자의 거리 별 외부선량률을 측정 및 분석하고, 방사선 작업종사자의 업무 행위 별 누적선량을 확인하여 피폭선량 저감화에 도움이 되는 주요한 요소를 알아보고자 한다. $^{18}F-FDG$WholeBody PET/CT검사를 받은 106명의 환자를 대상으로 검사 종료($75.4{\pm}3.3min$) 후 가슴을 기준 0, 10, 30, 50, 100 cm 거리에서 외부선량률을 측정하였다. 환자측면에서 외부선량률에 영향을 줄 수 있는 개별적 요인을 분석하기 위해 성별, 연령, BMI, 금식시간, 당뇨병 유무, 약물 투여정보, 크레아틴 수치 정보를 수집하였다. 수집된 정보의 통계분석은 ANOVA 분석 및 T-test를 시행하였다. 방사선 작업종사자 측면에서 피폭선량에 영향을 줄 수 있는 요인을 분석하기 위해 주사 업무를 하는 3명의 직원($T_1$, $T_2$, $T_3$)과 스캔 업무를 하는 3명의 직원($T_4$, $T_5$, $T_6$)에 각각 Personal pocket dosimeter를 착용시켜 업무시간 동안 누적된 선량을 기록하였다. 또한 방사선 작업종사자 별 응대시간을 측정하여 분석하였다. 각 거리 별 외부선량은 $246.9{\pm}37.6$, $129.9{\pm}16.7$, $61.2{\pm}9.1$, $34.4{\pm}5.9$, $13.1{\pm}2.4{\mu}Sv/hr$로 산출되었다. 환자측면에서, 근거리에서 성별, BMI, 선량, 크레아틴 수치에 의해 유의미한 차이가 있었지만, 거리가 증가할수록 그 차이는 감소하였다. 그 중 크레아틴 수치의 경우 100 cm에서 집단 간 통계적으로 유의한 차이를 보이지 않는 특징이 있었다. 환자 1명으로부터 받은 선량은 주사 업무를 하는 직원($T_1$, $T_2$, $T_3$)의 경우 0.70, 1.09, $0.55{\mu}Sv/person$이었고, 스캔($T_4$, $T_5$, $T_6$)의 경우 1.25, 0.82, $1.23{\mu}Sv/person$이었다. 응대시간이 상대적으로 적은 $T_4$직원의 경우 $T_3$, $T_5$보다 34% 낮은 누적선량을 확인할 수 있었다. 이를 토대로 환자와의 적정거리 유지와 응대시간 감소가 누적선량에 크게 작용함을 알 수 있었다. 위와 같은 점을 고려했을 때, 환자의 충분한 수분 섭취 및 배뇨, 방사선 작업종사자와 환자 간 적정거리유지(최소 100 cm이상) 및 응대시간 감소를 위해 노력해야 할 것이고, 환자의 video tracking system과 장비의 원격조정 등을 통해 피폭선량 저감화를 위해 노력해야 한다.

위암에시 PET의 임상적 역할 (Role of PET Scan in Gastric Cancer as a Diagnostic Tool)

  • 천기정;김병일;임상무
    • 대한위암학회:학술대회논문집
    • /
    • 대한위암학회 2002년도 제14회 추계학술대회
    • /
    • pp.24-33
    • /
    • 2002
  • Clinical application of positron emission tomography (PET) is rapidly increasing for the detection and staging of cancer at whole-body studies performed with the glucose analogue tracer 2-[fluorine-18]fluoro-2-deoxy-D-glucose (FDG). Although FDG PET cannot match the anatomic resolution of conventional imaging techniques in gastrointestinal and abdominal organs, it is particularly useful for identification and characterization of whole body at the same time. FDG PET can show foci of metastatic disease that may not be apparent at conventional anatomic imaging and can aid in the characterization of indeterminate soft-tissue masses. Most gastrointestinal cancer need to surgical management. FDG PET can improve the selection of patients for surgical treatment and thereby reduce the morbidity and mortality associated with inappropriate surgery. FDG PET is also useful for the early detection of recurrence and the monitoring of therapeutic effect. The gastrointestinal cancers, such as gastroeso-phageal cancer, colorectal cancer, liver cancer and pancreatic cancer, are common malignancies in Korea. PET is one of the most promising and useful methodology for the management of gastric cancer as well as other gastrointestinal cancers.

  • PDF