Zoom-in X-ray Micro Tomography System

  • Chun, In-Kon (Department of Biomedical Engineering, Kyung Hee University) ;
  • Lee, Sang-Chul (Department of Biomedical Engineering, Kyung Hee University) ;
  • Park, Jeong-Jin (Department of Biomedical Engineering, Kyung Hee University) ;
  • Cho, Min-Hyoung (Department of Biomedical Engineering, Kyung Hee University) ;
  • Lee, Soo-Yeol (Department of Biomedical Engineering, Kyung Hee University)
  • Published : 2005.10.01

Abstract

We introduce an x-ray micro tomography system capable of high resolution imaging of a local region inside a small animal. By combining two kinds of projection data, one from a full field-of-view (FOV) scan of the whole body and the other from a limited FOV scan of the region of interest, we have obtained zoomed-in images of the region of interest without any contrast a nomalies. We have integrated a micro tomography system using a micro-focus x-ray source, a $1248\times1248$ flat-panel x-ray detector, and a precision scan mechanism. Using the cross-sectional images taken with the zoom-in micro tomography system, we measured trabecular thicknesses of femur bones in postmortem rats. To compensate the limited spatial resolution in the zoom-in micro tomography images, we used the fuzzy distance transform for the calculation of the trabecular thickness. To validate the trabecular thickness measurement with the zoom-in micro tomography images, we compared the measurement results with the ones obtained from the conventional micro tomography images of the extracted bone samples.

Keywords

References

  1. T. F. Massoud and S. S. Gambhir, 'Molecular imaging in living subject: seeing fundamental biological processes in a new light', Genes & Development, Vol. 17, pp. 545-580, 2003 https://doi.org/10.1101/gad.1047403
  2. M. G. Pomper, 'Molecular imaging: an overview', Acad. Radiol., Vol. 8, pp. 1141-1153, 2001 https://doi.org/10.1016/S1076-6332(03)80728-6
  3. R. Weissleder and U. Mahmood, 'Molecular imaging', Radiology, Vol. 219, pp. 316-333, 2001 https://doi.org/10.1148/radiology.219.2.r01ma19316
  4. M. J. Paulus, S. S. Gleason, H. Sari-Sarraf, D. K. Johnson, C. J. Foltz, D. W. Austin, M. E. Easterly, E. J. Michaud, M. S. Dhar, P. R. Hunsicker, J. W. Wall and M. Schell, 'High-resolution x-ray CT screening of mutant mouse models', Proc. SPIE, Vol. 3921, pp. 270-279, 2000
  5. E. L. Ritman, 'Molecular imaging in small animals-roles for micro-CT', J. Cell. Biochem., Supp. 39, pp. 116-124, 2002
  6. S. M. Jorgensen, O. Demirkaya and E. L. Ritman, 'Three-dimensional imaging of vasculature and parenchyma in intact rodent organs with x-ray micro-CT', Am. J. Physiol., Vol. 275, H. 1103-1114, 1998
  7. M. J. Paulus, H. Sari-Sarraf, S. S. Gleason, M. Bobrek, J. S. Hicks, D. K. Johnson, J. K. Behel, L. H. Thompson and W. C. Allen, 'A new x-ray computed tomography system for laboratory mouse imaging', IEEE. Trans. Nucl. Sci., Vol. 46, pp. 558-564, 1999 https://doi.org/10.1109/23.775579
  8. S. Y. Wan, A. P. Kiraly, E. L. Ritman and W. E. Higgins, 'Extraction of the hepatic vasculature in rats using 3-D micro-CT images', IEEE. Trans. Med. Imag., Vol. 19 pp. 964-971, 2000 https://doi.org/10.1109/42.887843
  9. A. C. Kak and M. Slaney, Algorithms for reconstruction with nondifferacting sources, In: Principles of computed tomography imaging, New York: IEEE Press, pp. 86-92, 1988
  10. Z. H. Cho, Image reconstruction from projection in two dimensions, In: Foundations of medical imaging Singaporer: John Wiley & Sons, Inc., pp. 71-81, 1983
  11. H. Mori, R. Kyuushima, K. Fujita and M. Honda, 'High resolution and high sensitivity CMOS panel sensors for x-ray', IEEE Nucl. Sci. Sym. & Med. Imag. Conf. Conference Record in CD-ROM, 2001
  12. D. W. Holdsworth, M. Drangova and A. Fenster, 'A high-resolution XRII-based quantitative volume CT scanner', Med. Phys., Vol. 20 pp. 449-462, 1993 https://doi.org/10.1118/1.597038
  13. P. K. Saha, F. W. Wehrli and B. R. Gomberg, 'Fuzzy distance transform: theory, algorithms, and applications', Comput. Vis. Image Und., Vol. 86 pp. 171-90, 2002 https://doi.org/10.1006/cviu.2002.0974
  14. P. K. Saha and F. W. Wehrli, 'Measurement of trabecular bone thickness in the limited resolution region of in vivo MRI by fuzzy distance transform', IEEE Trans. Med. Imag., Vol. 23 pp. 53-62, 2004 https://doi.org/10.1109/TMI.2003.819925