• Title/Summary/Keyword: Wet-drop tests

Search Result 8, Processing Time 0.022 seconds

A study on accumulated damage of steel wedges with dead-rise 10° due to slamming loads

  • Seo, Byoungcheon;Truong, Dac Dung;Cho, Sangrai;Kim, Dongju;Park, Sookeun;Shin, Hyunkyoung
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.10 no.4
    • /
    • pp.520-528
    • /
    • 2018
  • This paper presents the results of experimental investigation on the elastic-plastic response of steel unstiffened wedges with dead-rise $10^{\circ}$ subjected to repeated impulsive pressure loadings. Repeated drop tests were performed with both wedge thickness and drop height varied. The pressure and histories were recorded during the tests and the permanent deflections were measured after every drop. Using the recorded test result, the effects of flexibility of wedges and repetition have been investigated. From the pressure history obtained from the tests the characteristics of the impulses were identified. Numerical simulations of the tests were made using the measured pressure history and the permanent deflection predictions were compared with those of the experiments.

Numerical Simulation for Fluid Impact Loads by Flat Plate with Incident Angles (받음각을 갖는 평판의 유체 충격 시뮬레이션)

  • Lee, Byung-Hyuk;Jung, Sung-Jun;Ryu, Min-Cheol;Kim, Yong-Su;Park, Jong-Chun
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.45 no.1
    • /
    • pp.1-9
    • /
    • 2008
  • The free-surface motions interacting with structures are investigated numerically using the Moving Particle Semi-implicit (MPS) method proposed by Koshizuka et al. (1996) for solving incompressible flow. In the method, Lagrangian moving particles are used instead of Eulerian approach using grid system. Therefore the terms of time derivatives in Navier-Stokes equation can be directly calculated without any numerical diffusion or instabilities due to the fully Lagrangian treatment of fluid particles and topological failure never occur. The MPS method is applied to the numerical study on the fluid impact loads for wet-drop tests in a LNG tank, and the results are compared with experimental ones.

A Basic Study on the Development of Floating Fish Aggregating Devices , Part I - Laboratory Static Tests on Synthetic Fiber Ropes - (부어초 개발에 관한 기초 연구(I) - 인조섬유 로우프의 정적시험 -)

  • H. Shin;K. Yamakawa;S. Hara;K.W. Park
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.31 no.1
    • /
    • pp.22-31
    • /
    • 1994
  • Fish aggregating devices(FAD) or artificial fish reefs deployed in the ocean space have been developed in various forms. The objective of FAD is to aggregate, cultivate and proliferate aquatic resources by making changes in ocean flows around it. developing spawning grounds, improving feeding areas and protecting larvae and juveniles. Most floating fish aggregating devices(FFAD) are in the form of surface buoys or subsurface buoys with a single point mooring system(SPMS). The mooring line of SPMS for the secure positions of FFAD is expected to keep great stresses as a result of the harsh ocean environment. Laboratory static tests on synthetic fiber ropes used for the SPMS were run. The Nylon wet rope specimen tests under increasing-and-decreasing loads showed about 20% strength drop. Also the logarithmic creep-tie behavior of fiber ropes was observed in the constant load test and compared with Flessner's formula.

  • PDF

Sulfur Poisoning of Ni Anode as a Function of Operating Conditions in Solid Oxide Fuel Cells (고체산화물 연료전지의 운전 조건에 따른 니켈 전극 황 피독 현상)

  • Lee, Ho Seong;Lee, Hyun Mi;Lim, Hyung-Tae
    • Korean Journal of Metals and Materials
    • /
    • v.56 no.12
    • /
    • pp.893-899
    • /
    • 2018
  • In the present study, we investigated the sulfur poisoning of the Ni anode in solid oxide fuel cells (SOFCs) as a function of operating conditions. Anode supported cells were fabricated, and sulfur poising tests were conducted as a function of current density, $H_2S$ concentration and humidity in the anode gas. The voltage drop was significant under the higher current density (${\sim}714mA/cm^2$) condition, while it was much reduced under the lower current density (${\sim}389mA/cm^2$) condition, at 100 ppm of $H_2S$. A secondary voltage drop, which occurred only at the high current density, was attributed to Ni oxidation in the anode. Thus, operation at high current density with high $H_2S$ concentration may lead to permanent deterioration in the anode. The effect of water content (10%) on the sulfur poisoning was also investigated through a constant current test (${\sim}500mA/cm^2$) at 10 ppm of $H_2S$. The cell operating with 10% wet anode gas showed a much smaller initial voltage drop, in comparison with a dry anode gas. The present study indicates that operating conditions, such as gas humidity and current density, should be carefully taken into account, especially when fuel cells are operated with $H_2S$ containing fuel.

Cross Flow Indirect Evaporative Cooler Made of a Plastic Film/Paper Composite (플라스틱 필름/종이 복합 재질의 직교류 간접증발소자)

  • Kim, Nae-Hyun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.41 no.1
    • /
    • pp.21-28
    • /
    • 2017
  • Indirect evaporative cooling, which utilizes a cooling effect obtained by the evaporation of water, is energy-effective compared to the conventional vapor compression method. It is also eco-friendly, due to the non-usage of CFC refrigerant. In this study, three indirect evaporative cooler samples of the cross flow type(size: $300mm{\times}300mm{\times}300mm$, channel pitch: $5mm{\times}5mm$, $5mm{\times}7mm$, $7mm{\times}7mm$) were made using plastic/paper composites. Tests were conducted to measure indirect evaporative efficiencies and pressure drops. Results showed that the efficiency was the highest for the $5mm{\times}5mm$ sample, owing to the largest surface area. The saved electrical energy was also the greatest for that sample. The pressure drop of the wet channel was larger than that of the dry channel as expected. A theoretical model was proposed, which underestimated both the indirect evaporation efficiency and the pressure drop.

Analytical Model of Salt Budget in the Upper Indian River Lagoon, Florida USA

  • Kim, Young-Taeg
    • Ocean and Polar Research
    • /
    • v.26 no.1
    • /
    • pp.33-42
    • /
    • 2004
  • Effect of freshwater discharge on the long-term salt balance in the Northern and Central Indian River Lagoon (IRL) is successfully simulated by a new analytical solution to a water balance-based one-dimensional salt conservation equation. Sensitivity tests show that the salinity levels drop abruptly even during the dry season (November to May) due to the high surface runoff discharge caused by tropical storms, depressions, and passage of cold fronts. Increasing surface runoff and direct precipitation has risen by ten times, lowering the salinity level down to 12psu in the Northern Central zone, and to 17 psu in the Northern zone. However, the salinity level in the Southern Central zone has decreased to 25 psu. High sensitivity of the Northern Central zone to freshwater discharge can be partially explained by a rapid urbanization in this zone. During the dry season, less sensitivity of the Southern Central zone to the increased surface runoff is attributed to the proximity of the zone to the Sebastian Inlet and a strong diffusion condition possibly resulting from the seawater intrusion to the surficial aquifer at the Vero Beach. During the wet season, however, the whole study area is highly sensitive to freshwater discharge due to the weak diffusion conditions. High sensitivity of the IRL to the given diffusion conditions guarantees that the fresh-water release occurs during strong wind conditions, achieving both flood control in the drainage basin and a proper salinity regime in the IRL.

Ecological Studies on Lettuce Drop Disease Occurring under Controlled Cultivation Conditions in Drained Paddy Fields (답리작 상치 시설재배지에서의 균핵병 발생생태에 관한 연구)

  • Shin Dong Bum;Lee Joon Tak
    • Korean Journal Plant Pathology
    • /
    • v.3 no.4
    • /
    • pp.252-260
    • /
    • 1987
  • Incidence of lettuce drop was observed throughout the growing season in the vinylhouse at the southern part of Korea, Kimhai. Occurrence of this disease was especially severe at the seedling stage. Number of sclerotia in surface soil $(30\times30\times5cm)$ was 22.0 at the seedling stage, and 5.3 at harvest in the infected area. Temperature for mycelial growth ranged from 5 to $30^{\circ}C$ with optimum temperature at $25^{\circ}C$. Sclerotia were formed fewer at low temperature, but their size was larger resulting in heavier dry weight than that at high temperature. The apothecia were formed from the sclerotia that were buried in March, April and September upto 3cm soil depth, but formed from those buried only 1 em soil depth in October. Sclerotia buried in June and December did not form apothecia regardless of soil depth by 90 days. The sclerotia buried in the 5cm of soil depth did not form apothecia. Sclerotia that were embedded in wet or flooded soil at $25^{\circ}C$ and $30^{\circ}C$ for 5 weeks lost their viability. Infection of lettuce was possible with mycelia originated from sclerotia on autoclaved lettuce plant fragments. The fungus was pathogenic on 25 plant species in 8 families in artificial inoculation tests. Lettuce seedlings appeared to be infected by airborne ascospore originated from sclerotia on crops and weeds around paddy fields, because sclerotia existing in soil might perish under long flood conditions during rice cultivation.

  • PDF

Comparison of the Dehumidification Performance Between LiCl and LiBr in a Liquid Desiccant Dehumidifying Element Having Criss-Cross Sinusoidal Channels (Celdek) (교차 적층된 파형 액체 제습 소자 (Celdek)에서 LiCl과 LiBr 수용액의 제습 성능 비교)

  • Kim, Nea-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.5
    • /
    • pp.27-34
    • /
    • 2018
  • Recently, liquid desiccant systems have received attention for the dehumidification of air. LiCl and LiBr are widely used in liquid desiccant systems due to their excellent thermo-physical properties. In this study, dehumidification tests were conducted with Celdek elements using LiCl and LiBr. During the tests, the dry and wet-bulb air temperatures were maintained at $35^{\circ}C$ and $28^{\circ}C$, respectively. The solution temperature was $20^{\circ}C$, the solution concentration was 50%, the solution circulation rate was 50 kg/h, and the frontal air velocity was varied from 2.0 to 4.0 m/s. The results show that the amount of dehumidification increased as the frontal velocity increased. On average, LiCl showed 27% higher dehumidification performance than LiBr, which was probably due to the lower saturation of the absolute humidity of LiCl compared with that of LiBr. On the other hand, LiBr yielded 12% larger pressure drop than LiCl. In general, the Sherwood numbers of LiCl and LiBr were approximately the same, showing that the effect of the desiccant on the Sherwood number was insignificant. Existing correlations highly overpredicted the present Sherwood numbers.