• 제목/요약/키워드: Welding factory

검색결과 35건 처리시간 0.021초

토치 회전식 자동용접 시스템의 용접공정변수 최적선정 (Optimum-selection in the Welding Process Variable for Torch-rotation Method of Automation Welding-machine System)

  • 김재열
    • 한국생산제조학회지
    • /
    • 제6권2호
    • /
    • pp.92-101
    • /
    • 1997
  • The purpose of this welding process of the exclusive welding-machine using welding torch-rotation type is to develop a mechanism which can solve the problem of twisting of welding wires and cables. The technique was developed by revising the torch position and smooth controlling of both the normal and reverse rotation. Some of the advantages of using the torch-rotation type apply to the work-rotation technique are the practical uses of increased work space and link work with the factory automation system. Do apply the welding process, I designed and made a special unit so called torch part in order to solve the problems of kinematical. And I made a control panel which can manipulate the progress of the entire process at the work shop. Even if it will be applied to another kind of axle casing's welding work, this process can be utilized if other sizes of the fixed pin and work part is produced and changed. The development of this exclusive welding-machine could reduce the manpower of skilled welding labor and increase productivity and better quality product in comparison to the handmade product.

  • PDF

변위환기를 이용한 대형 용접작업장의 공기환경 개선에 관한 연구 (Improvement of Indoor Air Environment in a Large Welding Factory by Displacement Ventilation)

  • 조동환;강석윤;최충현;임윤철;이재헌;문정환
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.69-74
    • /
    • 2005
  • In this paper, the indoor air environment in a large welding factory applied to displacement ventilation was investigated with experiment and numerical analysis for previous and new ventilation system. Concentration of fumes was analyzed for three cases with wind direction of outdoor. For experimental results, the dust concentration with new ventilation system decreased about 42-60% and the visibility increased about 11-18%. For numerical analysis, the exhaust efficiency of fumes was low when the wind and exhaust flow direction was inverse. It was found that the fumes in the factory decreased about 77% in case of the northern wind.

  • PDF

대형조선소 천장크레인 운전원의 용접흄 노출 실태 (Exposure status of welding fumes for operators of overhead traveling crane in a shipyard)

  • 이경민;김부욱;곽현석;하현철
    • 한국산업보건학회지
    • /
    • 제25권3호
    • /
    • pp.301-311
    • /
    • 2015
  • Objectives: Operators of overhead traveling crane in a ship assembly factory perform work to transmit large vessel blocks to an appropriate working process. Hazardous matters such as metal dusts, carbon monoxide, carbon dioxide, ozone, loud noise and fine particles are generated by variable working activities in the factory. The operators could be exposed to the hazardous matters during the work. In particular, welding fumes comprised of ultra fine particles and heavy metals is extremely hazardous for humans when exposing a pulmonary through respiratory pathway. Occupational lung diseases related to welding fumes are increasingly on an upward tendency. Therefore, the objective of this study is to assess properly unknown occupational exposure to the welding fumes among the operators. Methods: This study intended to clearly determine an equivalence check whether or not chemical constituents and composition of the dusts, which existed in the driver's cab, matched up with generally known welding fumes. Furthermore, computational fluid dynamics program(CFD) was used to identify a ventilation assessment in respect of a contamination distribution of welding fumes in the air. The operators were investigated to assess personal exposure levels of welding fumes and respirable particulate. Results: The dust in an operation room were the same constituents and composition as welding fumes. Welding fumes, which caused by the welding in a floor of the factory, arose with an ascending air current up to a roof and then stayed for a long time. They were considered to be exposed to the welding fumes in the operation room. The personal exposure levels of welding fumes and respirable particulate were 0.159(n=8, range=0.073-0.410) $mg/m^3$ and 0.138(n=8, range=0.087-0.178) $mg/m^3$, respectively. They were lower than a threshold limit value level($5mg/m^3$) of welding fumes. Conclusions: These findings indicate that an occupational exposure to welding fumes can exist among the operators. Consequently, we need to be keeping the operators under a constant assessment in the operator process of overhead traveling crane.

굴삭기공장에서 로봇을 이용한 용접공정의 3D 시뮬레이션 사례 연구 (A Case Study of the Design of Robot Welding Station in an Excavator Factory Using 3D Simulation)

  • 문덕희;조현일;백승근
    • 한국시뮬레이션학회:학술대회논문집
    • /
    • 한국시뮬레이션학회 2005년도 추계학술대회 및 정기총회
    • /
    • pp.113-121
    • /
    • 2005
  • Virtual Manufacturing is a powerful methodology for developing a new product, new equipment and new production system. It enables us to check the errors in design before production. This paper deals with a case study of virtual manufacturing in an excavator factory. Boom and rotating table of upper body are selected for application. 3D models of parts and fixtures are developed with CATIA and 3D simulation models are developed with IGRIP. These models are used for the design of fixture to verify the motion of the equipment. As a result, the manual welding systems are replaced by automatic systems and many design errors are corrected in the design phase, which enables us to reduce the developing cost and time.

  • PDF

제트 환기 시스템 도입에 의한 플랜트 기자재 용접장의 환경 개선 효과 분석 (Environmental Improvement in a Welding Factory by the Jet Ventilation System)

  • 임정호;이태구;문승재;이재헌
    • 플랜트 저널
    • /
    • 제4권2호
    • /
    • pp.66-72
    • /
    • 2008
  • In this inquiry, I would suggest jet ventilation system for effective elimination of welding flaw at machinery material welding shop on plant and evaluate the airstream on inner space and property of welding flaw's density through the examination. We can know outer atmosphere inflows at the speed of about 0.05m/s from western entrance in case of stopping the jet ventilation system, but airstream is accumulated on entire space. At height of worker's breathing surface(Ground Level = 1.5 m, below of GL) and welding work center, density of welding flaw on upper part(GL = 12m) is appeared 4 times higher than outer atmosphere at surplus range besides nearby of western entrance. At operation of jet ventilation system, since the smooth air current transfer at inner space and exhaust effect the wind speed is maintained at 0.932 m/s at the point of height of worker's breathing surface on inner space and it's concluded about the working conditions have been better than before operation of jet ventilation system because of that results show that inner space density of welding flaw at height of worker's breathing surface is 40.5%, and in the work shop, it is 20.3% at upper part.

  • PDF

용접 작업장 통신네트워크 구축을 위한 블록매체통신시스템 (Block Media Communication System for Implementation of a Communication Network in Welding Workplaces)

  • 김현식;강석근
    • 한국정보통신학회논문지
    • /
    • 제26권4호
    • /
    • pp.556-561
    • /
    • 2022
  • 본 논문에서는 선박 용접공정에 사용되는 장비에 전력선통신 기술을 접목하고 금속블록을 통신매체로 사용하는 블록매체통신시스템을 제시한다. 여기서는 디지털 피더와 금속블록을 지지하는 핀지그에 유도성 커플러를 설치하고, 피더에 연결된 용접건에서 발생되는 전류에 정보신호를 더하여 금속블록에 인가함으로써 작업이 시작되면 현장에서 발생되는 정보를 상황실 서버에 실시간 전송한다. 현장시험 결과, 제시된 블록매체통신시스템의 송신부에서 전송된 데이터는 상황실 서버컴퓨터에 정확하게 수신되는 것을 확인하였다. 따라서 제시된 시스템은 기존 용접공정에 대한 변경 없이 구축이 가능하므로 향후 조선소 스마트 팩토리화를 통한 조선산업의 경쟁력 강화에 도움이 될 것으로 기대된다. 또한 전자파 차폐 환경이나 밀폐된 공간에서 작업자에게 발생할 수 있는 응급상황에 신속한 대처가 가능하므로 산업재해 예방효과도 클 것으로 사료된다.

모 조선업 작업장의 공기중 용접흄농도에 관한 조사 (A Study on the Concentration of Welding Fume in a Shipbuilding Factory)

  • 김광종;송기창
    • 한국산업보건학회지
    • /
    • 제1권1호
    • /
    • pp.68-72
    • /
    • 1991
  • The present investigation studied the welding fumes produced during the arc welding process at a shipyard. The air at the shipyard was sampled (between February and May, 1990) to determine the total welding fume concentration, its heavy metal content and the concentrations of different sized particles of the welding fumes. The results were as follows : 1. Forty-four out of 50 samples showed welding fume concentrations which exceeding the threshold limit value of $5mg/m^3$. The geometric mean of welding fume concentration was $9.73mg/m^3$ ($2.14-24.86mg/m^3$), and the nighest level was found at the dock assembly shop ($12.0mg/m^3$). 2. The welding fume concentration measured with personal air sampler was 4.2 times greater than that measured with area sampler. 3. Of the heavy metals analyzed, Fe was found to be the most concentrated at $1.29mg/m^3$ ; it constitued 13.3% of the total welding fume concentration. 4. Of the different sized particles that make up the welding fumes, there was a tendency for the smaller particles to be more concentrated. Particles that measured $7{\mu}$ or less in diameter constituted 85.8% of the total welding fume concentration.

  • PDF

용접 불티 차단막의 방염 및 난연성능 평가 (An Evaluation of Flame and Fire Retardant Performance for Welding Blanket)

  • 이근원;권오승;하동명
    • 한국화재소방학회논문지
    • /
    • 제15권2호
    • /
    • pp.53-58
    • /
    • 2001
  • 본 연구에서는 조선 및 화학공장 등 산업현장에서 용접·용단작업 공정에서 비산 되는 불티에 의한 화재 예방을 위하여 불티 차단막에 관한 방염 및 난연 성능 평가를 실시하였다. 방염성능 실험결과 기존제품의 용접불티 차단막 6종 모두 충분한 방염성능을 갖고 있었다. 그러나, 용접·용단 불꽃에 의한 난연성 실험 결과 섬유유리에 수지코팅한 제품 2종은 용접·용단 불티에 대한 화재예방성능이 부족한 것으로 나타났다. 용접 불티 차단막의 최소산소지수의 국내기준은 30이상으로 고려하는 것이 좋을 것으로 사료된다. 용접 불티 차단막의 성능향상을 위한 제속적인 연구가 필요하며, 방염 및 난연성능 기술지침 개발의 기초자료로서 활용될 수 있을 것으로 사료된다.

  • PDF

PIV 속도장 측정기법을 이용한 공장 실내환기 개선방안 연구 (Improvement of Natural Ventilation in a Factory Building Using a Velocity Field Measurement Technique)

  • 임희창;김형범;이상준
    • 대한기계학회논문집B
    • /
    • 제25권10호
    • /
    • pp.1427-1435
    • /
    • 2001
  • Air movement in wokplaces, whether resulting from a forced ventilation system or naturally occurring airflow, has a significant impact on occupational health. In a huge shipbuilding factory building, typical harmful factors such as fume or vaporized gas from welding and cutting of steel plates, and dusts from grinding give unpleasant feeling. From field data survey, the yearly dominant, wind directions for the shipbuilding factory building tested were northwest, northeast and southeast Among the three wind directions, the ventilation improvement was the worst for the northeastern wind. This study was focused on location of the opening vents in order to utilize the natural ventilation effectively. Instantaneous velocity fields inside the 1/1000 scale-down factory building model were measured using a 2-frame PIV system. The factory building model was embedded in an atmospheric boundary layer simulated in a wind tunnel. The modified vents improve the internal Ventilation flow with increasing the flow speed more than two times, compared with that of present vents.

뿌리기업 스마트공장 구축 현황과 영향관계 분석 (Investigation of Factors for Smartization of Ppuri Enterprises Based on the Smart Factory Status)

  • 김보경;이상목;김태범;김택수;김창경
    • 한국분말재료학회지
    • /
    • 제29권2호
    • /
    • pp.166-175
    • /
    • 2022
  • Ppuri or Root technology primarily includes technologies such as casting, mold, plastic working, welding, heat treatment and surface treatment. It is regarded as an essential element for improving the competitiveness of the quality of final products. This study investigates the current status of smart factory implementation for Ppuri companies and analyzes the influencing relationships among various company factors. The factors affecting smart factory implementation for Ppuri companies are sales, exports, number of technical employees, and holding corporate research institutes. In addition, this research shows that even if smart factory implementation is pursued for data collection, data utilization is not implemented properly. Thus, it is suggested that the implementation of smart factories requires not only the availability of facilities and systems but also proper data utilization.