• 제목/요약/키워드: Weighted Difference Image

검색결과 99건 처리시간 0.025초

림프절의 자기공명영상의 특징: 가토에서 T1과 T2 강조영상의 비교 (Magnetic resonance imaging characteristic of lymph nodes: Comparison of T1 and T2 weighted image in normal rabbits)

  • 이기창;최민철;최호정;윤정희;최승홍;문우경;정진욱
    • 대한수의학회지
    • /
    • 제44권2호
    • /
    • pp.311-315
    • /
    • 2004
  • The detection of lymph node metastasis is an important step in tumor staging and is significant for therapy planning. It has been challenged to yield an appropriate image with diagnostic methods such as Magnetic Resonance (MR) and Computed Tomography (CT). Though CT has been used widely and accessed easily to show internal organs, it can hardly provide difference between lymph node and adjacent vessel or fat tissue. It has been well established that MR can reveal the subtle discrepancy within soft tissue. This study investigated the suitability of MR lymph node imaging without contrast enhancement by comparison of T1-weighted image (T1WI) and T2- weighted image (T2WI) in ten normal rabbits. According to the pulse sequence optimized from preliminary study, T1-weighted spin-echo (repetition time/echo time=400/12 ms) and T-2 weighted fast spin-echo (repetition time/echo time=3500/84 ms) images covering the hind limbs and pelvic region were acquired at 1.5 T. Two radiologists scrupulously evaluated the MR images in consensus. And signal intensity of lymph nodes was compared with that of adjacent fat. Statistical analysis showed that T1-weighted coronal image visualized the lymph nodes (iliac, superficial inguinal and popliteal lymph nodes) quickly and consistently rather than T2-weighted one. Conclusively, T1WI for evaluation of lymph nodes is moderately better than T2WI and appears to have potential for quick and sufficient mapping of the lymph nodes. In addition, this normal MR image of lymph nodes could be applied to further study for the evaluation of lymphatic system in abscess and tumor bearing animal model.

간 경화도 측정을 위한 3.0T 자기공명 탄성계수 영상의 유용성에 대한 고찰 : 확산계수 영상 및 T2 강조 영상과의 비교 (The study of utility about magnetic resonance elastography for measurements of liver stiffness : the comparisons of ADC value & T2 weighted image)

  • 김상우;강충환;김성호;김경수;김순배
    • 대한디지털의료영상학회논문지
    • /
    • 제14권1호
    • /
    • pp.21-29
    • /
    • 2012
  • The purpose of this study is to evaluate the mutual relations by measuring SNR from T2 weighted image and ADC values on the basis of the stiffness values from liver tissues. This study was conducted that total 37 people(23 of males and 11 of females) were taken the liver MRI examination and average age was $54.5{\pm}12.7$ years old. The equipment was MAGNETOM Skyra 3.0T (SIEMENS, Erlangen, Germany) and 32 channel body-array coil. The examination were conducted with HASTE T2 weighted image by axial plane, Spin-echo EPI (echo planner image) DWI (b-value = 800) and Magnetic resonance elastography. The ROIs (region of interest: 200-300 $mm^2$) were established on the basis of the first axial stiffness image corresponded 95% confidence interval from axial stiffness image and then were measured values. After drawing the grid lines, signals were measured SNR from T2 weighted image and ADC values on the same locations that were analysed other 3 planes respectively. The results were showed correlation (0.057) that were increased to SNR from T2 weighted image by increasing stiffness value that no significant difference statistically p = 0.003. Other results were showed correlations (-0.301) that were decreased to ADC values by increasing stiffness values that no significant difference statistically p = 0.088. In the 3.0T equipment, the results may be error in much the same fashion as the 1.5T from ADC values by evaluation of fibrosis stage. However, Magnetic resonance elastography would be useful method that is used to diagnose exactly liver fibrosis stages in the 3.0T.

  • PDF

고속스핀에코기법을 이용한 MRI검사에서 ETL 변화에 따른 영상 blurring의 평가 (Evaluation of the Image Blurring in the Fast Spin Echo Technique ccording to Variation of the ETL)

  • 권순용;임우택;강충환;김경수;김순배;김현수
    • 대한디지털의료영상학회논문지
    • /
    • 제15권2호
    • /
    • pp.55-61
    • /
    • 2013
  • The purpose of this study is to evaluate image blurring according to variation of the ETL and propose the clinically appropriate ETL range. SIEMENS MAGNETOM Skyra 3.0T and 20 channel head coil were used for the study. MRI phantom was kept the lines horizontally to three direction(X,Y,Z) of the coil and T1, T2 weighted images that used the fast spin echo technique acquired. The ETL with increase of 10 was applied from 10 to 80. In addition, the ETL with increase of 1 was applied in the interval statistically significant differences occurred. And T1, T2 weighted images that used the conventional spin echo technique acquired to compare image blurring of the images that used the fast spin echo technique. The slope of lattice in the images was measured using Image J 1.47v program to evaluate image blurring. And image blurring was determined by the degree of the slope. The statistical significance of both techniques was evaluated by the Kruskal-Wallis test of the SPSS 17.0v. And the correlation of the ETL and image blurring was evaluated quantitatively by regression analysis. The slope of the T1, T2 weighted images that used fast spin echo technique decreased as contrasted with conventional spin echo technique. In the result of the Kruskal-Wallis test, the T1, T2 weighted images that used fast spin echo technique made a significant difference with conventional spin echo technique. Particularly, in the Tomhane' T2 test, the T1, T2 weighted images made a significant difference from ETL 22 and 31 respectively. In the result of the regression analysis, the R-squared of the T1, T2 weighted images are 0.762 and 0.793. It is difficult to apply the long ETL in the T1 weighted image caused by the short TR and multi-slices study. Therefore, clinical impact according to variation of the ETL is very slight in the T1 weighted images. But the application of the proper ETL is demanded in T2 weighted images using the fast spin echo technique in order to prevent image blurring.

  • PDF

에지정보를 이용한 적응적 가중메디안필터에 대한 연구 (A study on adaptive weighted median filter using edge information)

  • 이용환;박장춘
    • 한국정보처리학회논문지
    • /
    • 제6권10호
    • /
    • pp.2830-2837
    • /
    • 1999
  • Image processing steps are consist of image acquisition, preprocessing, region, segmentation and recognition. But image corrupted commonly by noise reduction methods, many filters were proposed like mean filter, median filter, weighted median filter, Cheikh filter, and Kyu-cheol lee filter as spatial noise reduction filtering. We propose a new edge detection algorithm so that we find out edge existence and nonexistence. In non-edge area, we selectively apply weighted median filter based upon using information of difference value between weighted median filter's value and center pixel's value. As a result, we finally prove a better performance of noise reduction by applying adaptive weighted median filter and improvement of processing time through using simple algorithm.

  • PDF

인간 시각의 칼라 활성 가중 왜곡 척도를 이용한 칼라 영상 양자화 (Color image quantization using color activity weighted distortion measure of human vision)

  • 김경만;이응주;박양우;이채수;하영호
    • 전자공학회논문지B
    • /
    • 제33B권4호
    • /
    • pp.101-110
    • /
    • 1996
  • Color image quantization is a process of selecting a set of colors to display an image with some representative colors without noticeable perceived difference. It is very important in many applications to display a true color image in a low cost color monitor or printer. the basic problem is how to display 224 colors with 256 or less colors, called color palette. In this paper, we propose an algorithm to design the 256 or less size color palette by using spatial maskin geffect of HVS and subjective distortion measure weighted by color palette by using spatial masking effect of HVS and subjective distortion measure weighted by color activity in 4*4 local region in any color image. The proposed algorithm consists of octal prequantization and subdivision quantization processing step using the distortion measure and modified Otsu's between class variance maximization method. The experimental results show that the proposed algorithm has higher visual quality and needs less consuming time than conventional algorithms.

  • PDF

움직임 벡터를 이용한 낙상 감지 시스템 (Fall Detection System Using Motion Vector)

  • 김상수;김선우;최연성
    • 한국정보전자통신기술학회논문지
    • /
    • 제9권1호
    • /
    • pp.38-44
    • /
    • 2016
  • 본 논문에서는 움직임 벡터를 이용한 낙상 감지 시스템에 관해 기술한다. 두드러진 움직임을 위한 가중치 차영상 기법, 움직임 벡터를 이용하여 인간이라고 판단되는 블랍을 검출하고, 추출된 움직임 벡터를 이용하여 낙상 여부를 판단한다. 기존의 영상 기반 낙상 감지 시스템의 경우 특정 방향으로 낙상이 발생하는 경우에만 낙상 감지에 성공하였지만 제안 시스템의 경우 다양한 각도에서 낙상이 발생하여도 상황 판단이 가능하다는 장점이 있다. 실험을 위해서 150개의 상황을 연출하였으며, 약 85% ~ 97.1% 낙상 상황 판단 성공률을 보였다.

Weighted Collaborative Representation and Sparse Difference-Based Hyperspectral Anomaly Detection

  • Wang, Qianghui;Hua, Wenshen;Huang, Fuyu;Zhang, Yan;Yan, Yang
    • Current Optics and Photonics
    • /
    • 제4권3호
    • /
    • pp.210-220
    • /
    • 2020
  • Aiming at the problem that the Local Sparse Difference Index algorithm has low accuracy and low efficiency when detecting target anomalies in a hyperspectral image, this paper proposes a Weighted Collaborative Representation and Sparse Difference-Based Hyperspectral Anomaly Detection algorithm, to improve detection accuracy for a hyperspectral image. First, the band subspace is divided according to the band correlation coefficient, which avoids the situation in which there are multiple solutions of the sparse coefficient vector caused by too many bands. Then, the appropriate double-window model is selected, and the background dictionary constructed and weighted according to Euclidean distance, which reduces the influence of mixing anomalous components of the background on the solution of the sparse coefficient vector. Finally, the sparse coefficient vector is solved by the collaborative representation method, and the sparse difference index is calculated to complete the anomaly detection. To prove the effectiveness, the proposed algorithm is compared with the RX, LRX, and LSD algorithms in simulating and analyzing two AVIRIS hyperspectral images. The results show that the proposed algorithm has higher accuracy and a lower false-alarm rate, and yields better results.

3차원 다중 치과 CT 영상의 고화질 스티칭 기법 (High-quality Stitching Method of 3D Multiple Dental CT Images)

  • 박세윤;박성진;이정진;신준석;신영길
    • 한국멀티미디어학회논문지
    • /
    • 제17권10호
    • /
    • pp.1205-1212
    • /
    • 2014
  • In this paper, we propose a high-quality stitching method of 3D multiple dental CT images. First, a weighted function is generated using the difference of two distance functions that calculate a distance from the nearest edge of an overlapped region to each position. And a blending ratio propagation function for two gradient vectors is parameterized by the difference and magnitude of gradient vectors that is also applied by the weighted function. When the blending ratio is propagated, an improved region growing scheme is proposed to decide the next position and calculate the blending intensity. The proposed method produces a high-quality stitching image. Our method removes the seam artifact caused by the mean intensity difference between images and vignetting effect. And it removes double edges caused by local misalignment. Experimental results showed that the proposed method produced high-quality stitching images for ten patients. Our stitching method could be usefully applied into the stitching of 3D or 2D multiple images.

T1, T2강조영상, FLAIR영상의 임상 적용 (T1-, T2-weighted, and FLAIR Imaging: Clinical Application)

  • 김재형
    • Investigative Magnetic Resonance Imaging
    • /
    • 제13권1호
    • /
    • pp.9-14
    • /
    • 2009
  • T1, T2강조영상, FLAIR (fluid attenuated inversion recovery) 영상기법은 뇌 MRI의 가장 기본적인 영상기법들이다. T1강조영상은 짧은 TR과 짧은 TE를 이용한 스핀에코 기법으로서 조직의 T1이완시간의 차이를 신호 차이로 반영하는 기법이다. 짧은 TR을 사용하면 조직 간에 종축 자기화의 회복 정도가 크게 차이나게 되며 이를 신호에 반영하는 것이다. T2강조영상은 긴 TR과 긴 TE를 이용한 스핀에코 기법으로서 조직의 T2이완시간의 차이를 신호 차이로 반영하는 기법이다. 긴 TE을 사용하면 조직 간에 횡축 자기화의 붕괴가 크게 차이나게 되며 이를 신호에 반영하는 것이다. FLAIR는 180도 반전펄스를 먼저 가하는 반전회복 (inversion recovery) 기법의 일종으로서 뇌척수액의 신호를 억제하기 위하여 2500 msec 정도의 반전시간을 적용한다.

  • PDF

조영제 사용 전 후 확산강조영상 검사의 비교 분석에 대한 연구 (A Study on Comparative Analysis of Diffusion Weighted Image Examination before and after Contrast Injection)

  • 구은회
    • 대한디지털의료영상학회논문지
    • /
    • 제11권2호
    • /
    • pp.51-57
    • /
    • 2009
  • The purpose of this study would evaluate if having clinical effects on diffusion image with quantitative analysis through ADC values of brain's normal tissue and lesions before and after contrast injections using a 3.0T. From November in 2007 until December in 2008, a total of 32 patient was performed on 3.0T(Signa Excite, GE Medical System, USA) with the normal or lesions in the patient who requests diffusion weighted image with 8channel head coil. The pulse sequence was used with spin echo EPI(TR: 10000msec, TE: 72.2 msec, Matrix: 128*128, FOV: 240 mm, NEX: 1, diffusion direction: 3, b-value: 1000). Measurement results of ADC values on lesions, CSF, white matter, gray matter, lesions after contrast injection were measured less 75% than before contrast injection, infarction: 100%, CSF: 78%(high), white matter: 71.4%(low), gray matter: 50%(high, low). The results of paired t-test on the deference of ADC values which statically is significant in three(lesions, CSF, white matter)regions except for white matter(p<0.05). Quantitative analysis of lesions, CSF, white matter, gray matter have difference on all regions. ADC values were low in lesions and white matter, normal CSF after contrast injection commonly is high than before contrast injection, ADC values which white matter were high and low (50:50) after contrast injection. 3.0T diffusion weighted image clinically supposed that performing DWI examination after contrast injection was not desirable because of having effects on brain tissue.

  • PDF