• Title/Summary/Keyword: Weight technique

Search Result 1,713, Processing Time 0.035 seconds

FEASIBILITY MAPPING OF GROUND WATER YIELD CHARACTERISTICS USING WEIGHT OF EVIDENCE TECHNIQUE: A CASE STUDY

  • Heo, Seon-Hee;Lee, Ki-Won
    • Proceedings of the KSRS Conference
    • /
    • 2005.10a
    • /
    • pp.430-433
    • /
    • 2005
  • In this study, weight of evidence(WOE) technique based on the bayesian method was applied to estimate the groundwater yield characteristics in the Pocheon area in Kyungki-do. The ground water preservation depends on many hydrogeologic factors that include hydrologic data, landuse data, topographic data, geological map and other natural materials, even with man-made things. All these data can be digitally collected and managed by GIS database. In the applied technique of WOE, The prior probabilities were estimated as the factors that affect the yield on lineament, geology, drainage pattern or river system density, landuse and soil. We calculated the value of the Weight W+, W- of each factor and estimated the contrast value of it. Results by the ground water yield characteristic calculations were presented in the form of posterior probability map to the consideration of in-situ samples. It is concluded that this technique is regarded as one of the effective technique for the feasibility mapping related to detection of groundwater bearing zones and its spatial pattern.

  • PDF

Short-Term Complications of Percutaneous Endoscopic Gastrostomy according to the Type of Technique

  • Gang, Mi Hyeon;Kim, Jae Young
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.17 no.4
    • /
    • pp.214-222
    • /
    • 2014
  • Purpose: The method of percutaneous endoscopic gastrostomy (PEG) tube placement can be divided into the pull and introducer techniques. We compared short-term complications and prognosis between patients who underwent the pull technique and two other types of introducer techniques, the trocar introducer technique and T-fastener gastropexy technique. Methods: Twenty-six patients who underwent PEG were enrolled in this study. We retrospectively investigated the age, sex, body weight, weight-for-age Z-score, underlying diseases, PEG indications, complications, duration of NPO (nil per os), pain control frequency, and duration of antibiotic therapy. The patients were classified into three groups according to the PEG technique. The occurrence of complications was monitored for 10 weeks after the procedure. Results: The age, sex, body weight, and weight-for-age Z-score were not significantly between the three groups. Most patients had cerebral palsy and seizure disorders. Dysphagia was the most common indication for PEG. Major complications occurred in 5 (50%), 4 (66.7%), and 0 (0%) patients in group I, II, and III, respectively (p=0.005). Further, peristomal infection requiring systemic antibiotic therapy occurred in 2 (20%), 3 (50%), and 0 (0%) patients in group I, II, and III, respectively (p=0.04). There was no significant difference between the groups with respect to minor complications, duration of NPO, pain control frequency, and duration of antibiotic therapy. Conclusion: The results indicate that the T-fastener gastropexy technique was associated with the lowest rate of major complications.

Accuracy evaluation of diagnostic parameters estimated by uroflowmetry technique measuring hydraulic pressure (수압측정 방식의 요류검사 진단매개변수의 정확도 평가)

  • Kim, Kyung-Ah;Choi, Seong-Su;Kim, Sung-Sik;Kim, Kun-Jin;Park, Kyung-Soon;Cha, Eun-Jong
    • Journal of Sensor Science and Technology
    • /
    • v.16 no.6
    • /
    • pp.413-418
    • /
    • 2007
  • Uroflowmetry is of great convenience to diagnose benign prostate hypertrophy common in aged men. The urinary flow rate is obtained by weight measurement using load cell, however, sensitive to impact noise. An alternative technique was recently proposed to measure hydraulic pressure instead of weight and demonstrated to introduce significantly reduced noise. In this paper, we described the measured diagnostic parameters between the weight and pressure measuring techniques in 10 normal men. The weight and pressure signals were simultaneously acquired during urination, converted into urine volumes, then differentiated to obtain flow rate signals, which showed very similar waveforms. Diagnostic parameters evaluated by pressure measuring technique were well correlated with the standard weight measuring technique (correlation coefficient > 0.99). Therefore, the new uroflowmetry based on hydraulic pressure measurement can provide accurate diagnostic parameters, which would be clinically valid.

Assessment of the fit of zirconia-based prostheses fabricated with two different scan methods (서로 다른 두 가지 스캔법을 이용하여 제작된 지르코니아 보철물의 적합도에 대한 비교)

  • Choi, Hyun-Suk;Cho, Jin-Hyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.2
    • /
    • pp.135-143
    • /
    • 2017
  • Purpose: This research was conducted to compare the marginal and internal fit of zirconia prostheses fabricated with the model scan method and the intraoral scan method. Materials and methods: In this study, 20 extracted human mandibular first molar was used in the preparation of abutment tooth for the fabrication of zirconia prostheses. In the first group, the model scan method was applied on 10 prepared teeth. In the other group, the intraoral scan method was used on other 10 prepared teeth. Datum of both groups were transmitted to the software system. Afterwards, 20 zirconia prostheses were fabricated using the Ceramill system. Weight technique was used to evaluate the internal gap of the zirconia prostheses. In the Replica technique, marginal gap of the zirconia prostheses were analyzed by optical microscopy. Statistical analysis was based on one-way ANOVA. Results: Model scan group showed lower average weight than intraoral scan group when weight technique was applied, which has significance (P < .05). Also, model scan group showed significantly lower figures in all 5 measurements of replica technique than intraoral scan group (P < .05). Conclusion: Zirconia prostheses of both groups demonstrated clinically acceptable margin and internal fit. However, model scanned zirconia prostheses showed higher marginal and internal fit than intraoral scanned crowns.

Power analysis attack resilient block cipher implementation based on 1-of-4 data encoding

  • Shanmugham, Shanthi Rekha;Paramasivam, Saravanan
    • ETRI Journal
    • /
    • v.43 no.4
    • /
    • pp.746-757
    • /
    • 2021
  • Side-channel attacks pose an inevitable challenge to the implementation of cryptographic algorithms, and it is important to mitigate them. This work identifies a novel data encoding technique based on 1-of-4 codes to resist differential power analysis attacks, which is the most investigated category of side-channel attacks. The four code words of the 1-of-4 codes, namely (0001, 0010, 1000, and 0100), are split into two sets: set-0 and set-1. Using a select signal, the data processed in hardware is switched between the two encoding sets alternately such that the Hamming weight and Hamming distance are equalized. As a case study, the proposed technique is validated for the NIST standard AES-128 cipher. The proposed technique resists differential power analysis performed using statistical methods, namely correlation, mutual information, difference of means, and Welch's t-test based on the Hamming weight and distance models. The experimental results show that the proposed countermeasure has an area overhead of 2.3× with no performance degradation comparatively.

A technique for predicting the cutting points of fish for the target weight using AI machine vision

  • Jang, Yong-hun;Lee, Myung-sub
    • Journal of the Korea Society of Computer and Information
    • /
    • v.27 no.4
    • /
    • pp.27-36
    • /
    • 2022
  • In this paper, to improve the conditions of the fish processing site, we propose a method to predict the cutting point of fish according to the target weight using AI machine vision. The proposed method performs image-based preprocessing by first photographing the top and front views of the input fish. Then, RANSAC(RANdom SAmple Consensus) is used to extract the fish contour line, and then 3D external information of the fish is obtained using 3D modeling. Next, machine learning is performed on the extracted three-dimensional feature information and measured weight information to generate a neural network model. Subsequently, the fish is cut at the cutting point predicted by the proposed technique, and then the weight of the cut piece is measured. We compared the measured weight with the target weight and evaluated the performance using evaluation methods such as MAE(Mean Absolute Error) and MRE(Mean Relative Error). The obtained results indicate that an average error rate of less than 3% was achieved in comparison to the target weight. The proposed technique is expected to contribute greatly to the development of the fishery industry in the future by being linked to the automation system.

Development of a Load Measurement System for Vehicles using Tire Pressure System Technology (타이어 공기압 시스템 기술을 사용한 차량의 적재중량 측정 시스템 개발)

  • Park, Jae-Hyun;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.24 no.1
    • /
    • pp.33-39
    • /
    • 2020
  • In this paper, we propose the design technique of the vehicle's load weight measuring system using tire pressure, which is one of the physical elements of tires. The proposed technique consists of four processes: noise correction by load and vibration, gas flow correction, data mixer and weight conversion. Noise correction by load and vibration eliminates noise that increases the tire's internal pressure due to external shocks and vibrations produced by the vehicle while it is in motion. In the gas flow correction process, the noise of the internal pressure of the tire is increased due to the temperature rise of the ground with respect to the data obtained through the noise correction process due to the load and vibration. In the data mixer process, the load and pressure on the tolerances the empty, median and the full load are classified according to the change in pressure of the tire that is delivered perpendicular to the tire in the event of cargo. In the weight conversion process, weight is expressed by weight through weight conversion algorithms using noise correction results by load and vibration and gas flow correction. The weight conversion algorithm calculates the weight conversion factor, which is the slope of the linear function with respect to the load and pressure change, and converts the weight. In order to evaluate the accuracy of the loading weight measurement system of the vehicle using the tire pneumatic system technique proposed in this paper, we propose the design technique of the vehicle's load weight measuring system using tire pressure, which is one of the physical elements of tires.. Noise correction results by load and vibration and gas flow data correction results showed reliable results. In addition, repeated weight precision test showed better weight accuracy than the standard value of 90% of domestic companies.

A Study on the Subject Selection of VE Using Decision Weights Techniques (VE 대상선정을 위한 평가항목의 가중치결정방법에 관한 연구)

  • Yun, Dong-Jin;Sin, Byung-Yoon;Jeong, Yong-Sik;Lee, Sang-Beom
    • Journal of the Korea Institute of Building Construction
    • /
    • v.5 no.3 s.17
    • /
    • pp.83-90
    • /
    • 2005
  • Was used at step space-time mainly after VE technique sponsors in domestic in the 1960s but have been expanded to design step recently. Possibility of value elevation or cost reduction must choose member that is effectively for active and effective application of VE technique. In this study, when enforce design VE examining for weight decision corrosion protection been using in weight grant composition estimation technique, target choice process wishes to suggest formality and method that can be achieved effectively Main conclusion of this study sorts valuation items step by step for weight appropriation of valuation basis and give point on article of high position point after expert which employer is included estimates article by low rank step and this presented high position method that do union item by item and establishes by item weight. Did these techniques for giving weights so that importance for weight appropriation developed estimation program, and data save of target estimation standard and target estimation standard is possible using straight sit.

A Load Based Weight Multicasting Technique Design for efficient Multimedia Contents Delivery (효율적인 멀티미디어 컨텐츠 전송을 위한 부하 가중치 멀티캐스팅 기법의 설계)

  • Lee, Seo-Jeong;Kim, Seon-Ho
    • The Journal of Society for e-Business Studies
    • /
    • v.9 no.3
    • /
    • pp.277-288
    • /
    • 2004
  • The purpose of multimedia contents transmission is to resolve the large size and nonformal issues. Various multicasting technologies have been researched to support these issues. This paper suggests a technique to build multicast routing for safe and reliable transmission of multimedia contents. Network server nodes have their own weight with respect to communication loads. The weight is computed by a server's communication load with others. This suggests low delay routing with two or more edge server of content delivery network. We will show the weighted inter-server routing technique and analyze the network performance improvement caused by lower network traffic and delay.

  • PDF