• 제목/요약/키워드: Weight Inversion

검색결과 55건 처리시간 0.025초

Tillage Operational Analysis Based on Soil Moisture Content, Machine Speed, and Disc Space of Compact Disc Harrow

  • Okyere, Frank Gyan;Moon, Byeong Eun;Qasim, Waqas;Basak, Jayanta Kumar;Kahn, Fawad;Kang, Dae Sik;Yoon, Yong Cheol;Kim, Hyeon Tae
    • Journal of Biosystems Engineering
    • /
    • 제43권3호
    • /
    • pp.161-172
    • /
    • 2018
  • Purpose: During tillage operations, the selection of a working machine (tool) depends on the soil conditions as well as the type of tillage operation to be performed. The goal of this research was to ascertain the effects of varying working machine parameters of a compact disc harrow on tillage operations under various soil moisture content (SMC) conditions. Methods: The working machine parameters were the disc spacing and machine speed. The tillage parameters under investigation were the soil inversion ratio (SIR), tillage cutting depth (TCD), and soil clod breakage ratio (SCB). To determine the SIR, the areas of the white regions before and after tillage were obtained. The ratio of the difference of the areas of the white regions before and after tillage to the area of the white regions before tillage was considered as the SIR. The SCB was obtained as the ratio of the weight of soil clods after sieving with a mesh size of <0.02 m to the total weight of the soil clods before sieving. The soil TCD was measured using a tape measure at random points after the tillage operation. The resulting data were statistically analyzed in a one-way analysis of variance. Results: The highest soil inversion was achieved when the machine speed was 0.2 m/s with the disc spaced at 0.2 m in the 16.5% SMC. At a 0.4-m/s machine speed and 0.3-m disc spacing the highest soil breakage was achieved in the 26.5% SMC. The highest TCD was achieved at a 0.2-m/s machine speed and 0.2-m disc spacing in the 16.5% SMC. Conclusions: It was concluded that varying the working machine parameters, such as the disc spacing and machine speed, could significantly affect the soil inversion and soil clod breakage; however, it had no significant impact on the TCD.

Assessment and Comparison of Isokinetic Strength of Hip, Knee and Ankle Joints in Young Adults

  • Kim, Yong Hwan;Jee, Hae Mi
    • 국제물리치료학회지
    • /
    • 제9권1호
    • /
    • pp.1426-1434
    • /
    • 2018
  • This study was conducted to observe the isokinetic strength (IS) of the hip, ankle, and knee joints in young age groups. Thirty eight men and thirty one women with mean age of $30.4{\pm}3.5$ and $32.8{\pm}4.4years$, respectively, were enrolled in this study. Measurements of hip flexion, extension, abduction, and adduction at $30^{\circ}/sec$, Knee flexion and extension at $60^{\circ}/sec$, ankle inversion, eversion, plantarflexion, and dorsiflexion $30^{\circ}/sec$ were conducted. Absolute IS (Nm), relative IS (Nm/kg), strength ratios, correlations between movements were observed. Significant differences in absolute and relative strength were observed between groups in all movement except in the relative ankle strength. Relative isokinetic strength ratios of hip flexion/extension were .45 and .55, knee flexion/extension were .84 and .89, ankle dorsi/plantarflexion were .30 and .29, and ankle eversion/inversion were .86 and .84 for men and women, respectively. In the hip extension, men had about three times the body weight, and women had about 2.5 times the strength. The abduction muscle had about 1.5 times the body weight of both men and women. Height and body weight showed the significantly strong correlating relationship with hip (r, .76-.86) and knee (r, .67-.84) strength. However, ankle strength showed the comparatively correlating relationship, especially in women (r, .03 - .36). Similar age and physique characteristics of female and male groups could provide useful isokinetic strength reference values for developing the exercise program for healthy and rehabilitation groups.

경량화 시스템에 적합한 유한체 $GF(2^m)$에서의 고속 역원기 (A Fast Inversion for Low-Complexity System over GF(2 $^{m}$))

  • 김소선;장남수;김창한
    • 대한전자공학회논문지SD
    • /
    • 제42권9호
    • /
    • pp.51-60
    • /
    • 2005
  • 효율적인 암호 시스템의 설계는 환경에 적합한 유한체 연산이 뒷받침되어야 한다 특히 유한체에서의 역원 연산은 다른 연산에 비해 가장 많은 수행시간을 소비하므로, 개선에 대한 연구가 활발히 진행되고 있다. 본 논문에서는 다항식 기저를 기반으로 Extended binary god algorithm (EBGA)를 이용한 유한체 $GF(2^m)$에서의 고속 역원 알고리즘을 제안한다. 제안된 역원 알고리즘은 EBGA보다 $18.8\%$, Montgomery inverse algorithm (MIA)보다 $45.9\%$ 적은 수행횟수를 가진다. 또한 기존에 제안된 시스톨릭 어레이 구조 (Systolic array structure)는 유한체 차수 m이 증가하는 경우 많은 하드웨어 리소스가 요구된다. 따라서 스마트 카드나 모바일 폰 등과 같은 경량화와 저전력이 요구되는 환경에는 적용하기 힘들다. 본 논문에서는 경량화된 암호 시스템 환경을 바탕으로 공간복잡도가 적으면서 동기화된 연산을 수행하는 새로운 하드웨어 구조를 제시한다. 본 논문에서 제안된 하드웨어 구조는 유한체 $GF(2^m)$에서의 역원을 계산하기 위해 기존의 알고리즘보다 적은 덧셈 연산과 모듈러 감산 연산을 포함하고 있으며, 유한체 $GF(2^m)$와 GF(p)에 적용이 가능한 통합된 역원기이다.

전방 점프 착지 시 만성 발목 불안정성이 자세 조절에 미치는 영향 (The Effects of Chronic Ankle Instability on Postural Control during Forward Jump Landing)

  • Kim, Kew-wan;Jeon, Kyoungkyu;Park, Seokwoo;Ahn, Seji
    • 한국운동역학회지
    • /
    • 제32권1호
    • /
    • pp.9-16
    • /
    • 2022
  • Objective: The purpose of this study was to investigate how the chronic ankle instability affects postural control during forward jump landing. Method: 20 women with chronic ankle instability (age: 21.7 ± 1.6 yrs, height: 162.1 ± 3.7 cm, weight: 52.2 ± 5.8 kg) and 20 healthy adult women (age: 21.8 ± 1.6 yrs, height: 161.9 ± 4.4 cm, weight: 52.9 ± 7.2 kg) participated in this study. For the forward jump participants were instructed to stand on two legs at a distance of 40% of their body height from the center of force plate. Participants were jump forward over a 15 cm hurdle to the force plate and land on their non-dominant or affected leg. Kinetic and kinematic data were obtained using 8 motion capture cameras and 1 force plates and joint angle, vertical ground reaction force and center of pressure. All statistical analyses were using SPSS 25.0 program. The differences in variables between the two groups were compared through an independent sample t-test, and the significance level was to p < .05. Results: In the hip and knee joint angle, the CAI group showed a smaller flexion angle than the control group, and the knee joint valgus angle was significantly larger. In the case of ankle joint, the CAI group showed a large inversion angle at all events. In the kinetic variables, the vGRF was significantly greater in the CAI group than control group at IC and mGRF. In COP Y, the CAI group showed a lateral shifted center of pressure. Conclusion: Our results indicated that chronic ankle instability decreases the flexion angle of the hip and knee joint, increases the valgus angle of the knee joint, and increases the inversion angle of the ankle joint during landing. In addition, an increase in the maximum vertical ground reaction force and a lateral shifted center of pressure were observed. This suggests that chronic ankle instability increases the risk of non-contact knee injury as well as the risk of lateral ankle sprain during forward jump landing.

Robust Watermarking Scheme Based on Radius Weight Mean and Feature-Embedding Technique

  • Yang, Ching-Yu
    • ETRI Journal
    • /
    • 제35권3호
    • /
    • pp.512-522
    • /
    • 2013
  • In this paper, the radius weight mean (RWM) and the feature-embedding technique are used to present a novel watermarking scheme for color images. Simulations validate that the stego-images generated by the proposed scheme are robust against most common image-processing operations, such as compression, color quantization, bit truncation, noise addition, cropping, blurring, mosaicking, zigzagging, inversion, (edge) sharpening, and so on. The proposed method possesses outstanding performance in resisting high compression ratio attacks: JPEG2000 and JPEG. Further, to provide extra hiding storage, a steganographic method using the RWM with the least significant bit substitution technique is suggested. Experiment results indicate that the resulting perceived quality is desirable, whereas the peak signal-to-noise ratio is high. The payload generated using the proposed method is also superior to that generated by existing approaches.

시추공 3성분 계측 현장실험을 통한 미소지진 모니터링 정확도 향상 연구 (A Study on the Improvement of Microseismic Monitoring Accuracy by Borehole 3-Component Measurement Field Experiments)

  • 김중열;김유성;윤점동;권성일;권형일;박성빈;박주현
    • 지구물리와물리탐사
    • /
    • 제20권1호
    • /
    • pp.1-11
    • /
    • 2017
  • P파 및 S파의 초동주시를 활용한 역산기법들을 통해 미소지진 모니터링의 진원위치의 정확도를 향상시키기 위해 시추공 3성분 수진기를 이용한 현장실험이 수행되었다. 3성분 수진기의 수평 $\times$ 성분을 자북방향으로 정렬시키고 중추낙하형 발생원을 이용한 실험을 통해 계측자료의 P파 초동의 입자움직임으로부터 진원의 방향을 추정할 수 있었다. 한편 계측자료에서 S파의 식별이 어려운 경우에도 편극필터의 적용으로 S파의 초동주시를 발췌할 수 있었다. P파 초동주시만을 이용한 역산기법은 진원위치에 대한 초기치가 진원으로부터 크게 이격되면 국부적인 최소값으로 수렴하여 정해를 찾지 못하는 경우가 있다. 본 연구에서는 이러한 문제를 해결하기 위해 P파와 S파의 초동주시 차이를 이용한 진원위치 결정방법과 P파 초동주시만을 이용한 역산을 복합적으로 사용한 결과 진원위치의 정확도를 향상시킬 수 있었다.

후족부 관상면 배열 영상에 대한 고안 (Introduction of Hindfoot Coronal Alignment View)

  • 문일봉;전주섭;윤강철;최남길;김승국
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제29권4호
    • /
    • pp.225-228
    • /
    • 2006
  • 목 적: 후족부의 병리학적 상태의 치료와 평가를 위해서는 관상면에서 종골과 경골이 연관된 배열상태의 정확한 평가가 필수적이다. 이전의 방사선학적 검사인 발과 발목의 전후방향, 측방향, 사방향 촬영과 종골 축방향 촬영 등의 X-선 촬영상은 관상면에서 종골과 경골이 연관된 배열상태를 증명하지 못했다. 이에 본 연구에서는 후족부 관상면 배열영상(hindfoot coronal alignment view)을 새롭게 소개하고자 한다. 검사방법 : 1) 양쪽 발을 지탱할 수 있는 방사선투과성의 스탠드형 보조기구를 제작한다. 2) 양측 발은 weight-bearing position이 되게 한다. 3) 각각의 발의 위치는 발의 종축이 보조기구 판과 수직이 되도록 자세를 유지한다. 4) silhouette tracing: 발뒷꿈치 outline과 둘째 발가락이 일직선상으로 지나도록 위치시킨다. 5) 중심 X-선: 발바닥 쪽을 향해 약 $15{\sim}20^{\circ}의 각도로 종골의 뒷쪽을 향해 입사한다. 결 과 : 1) 경골 축과 종골의 내측, 외측 결절의 영상이 함께 표출된다. 2) 종골이 회전되지 않아야 한다. 3) 거퇴관절강(talotibial joint space)이 함께 나타나야 한다. 결 론: CT나 MRI 영상에서도 관상면에서 후족부의 배열상태를 증명할 수 있지만, 환자의 체중이 주어지지 않기 때문에 발의 임상적인 증상을 보여주기에는 충분하지 못했다. 하지만 후족부 관상면 배열영상은 후족부의 inversion, eversion의 자세변화를 보여주고, 경골 원위부와 종골의 varus, valgus deformity의 치료를 위한 평가 자료로 좋은 검사방법이며, 비교적 자연스럽고 편안한 자세로 환자에게 큰 도움을 줄 것으로 사료된다.

  • PDF

Eigenanalysis 방식을 이용한 적응 SLC(sidelobe canceller)시스템의 성능향상에 관한 연구 (A Study on Performance Improvement of Adaptive SLC System using Eigenanalysis Method)

  • 김세연;정신철;이병섭
    • 한국전자파학회논문지
    • /
    • 제12권5호
    • /
    • pp.694-704
    • /
    • 2001
  • 본 논문에서는 상세화된 빔 패턴에 대한 제한조건들은 유지한 채 잡음이나 간섭신호에 대한 효과적인 제거를 제공하는 Eigencanceller의 성능을 평가하였다. Eigencanceller는 배열입력으로 간섭신호와 잡음이 수신되는 경우와 희망신호, 간섭신호 그리고 잡음이 수신되는 경우에 따라 제한조건들이 달라지게 되고 최적의 가중치에 대한 해도 달라진다. 각각의 경우에 가중치 벡터에 대한 정상상태에서의 분석을 통해서 희망 신호의 유.무에 관계없이 최적의 가중치 벡터에 대한 식들은 모두 동일하게 간섭신호에 직교하는 부분공간(subspace)으로의 희망신호의 사영의 형태로 간략화 됨을 알 수 있었다. 그리고 Eigencanceller구조가 DMI(direct matrix inversion)방식보다도 우수한 성능을 보임을 수학적인 분석가 시뮬레이션을 통해 살펴보았다.

  • PDF

간섭 널 공간 투사에 의한 신호차단 방식의 적응 빔 형성 (Signal-Blocking-Based Robust Adaptive Beamforming by Interference Null Space Projection)

  • 최양호
    • 한국통신학회논문지
    • /
    • 제36권4A호
    • /
    • pp.399-406
    • /
    • 2011
  • 적응 빔 형성기 (adaptive beamformer)는 원하는 신호의 도래각 정보를 이용하여 간섭신호를 제거하면서 원하는 신호 방향으로 어레이 이득을 최대로 한다. 그러나 도래각 정보가 정확치 않다면, 원하는 신호도 감쇠되어 심각한 성능저하가 발생한다. 이러한 문제에 대처하기위해, 신호차단에 기초하여 적응 빔을 형성하는 Duvall 구조를 이용하여, 효과적으로 원하는 신호의 도래각 추정을 통해 에러에 강인한 적응 빔 형성방법을 제시하였다. 제시된 방법에서는 간섭신호공간을 추정하여 이에 직교하도록 간단한 계산을 통해 가중벡터를 구하며, 특히 센서의 수가 많을수록 기존 방식에 비해 계산량의 절감이 크다.

Morphological study of synthesized PVDF membrane using different non-solvents for coagulation

  • Yadav, Meenakshi;Upadhyay, Sushant;Singh, Kailash;Chaturvedi, Tarun Kumar;Vashishtha, Manish
    • Membrane and Water Treatment
    • /
    • 제13권4호
    • /
    • pp.173-181
    • /
    • 2022
  • Polyvinylidene fluoride (PVDF) flat sheet hydrophobic membranes were prepared using 16 wt% PVDF in Dimethyl acetamide (DMAc) by phase inversion technique for desalination application using Membrane Distillation (MD). In this work, the effect of coagulation mediums such as ethanol and water as well their synergistic behavior on the fabricated PVDF membrane morphology was studied using SEM. Moreover, other characteristics required for the membrane distillation applications namely porosity, hydrophobicity and tensile strength were measured using the gravimetric method, sessile drop method and universal testing machine respectively. It was observed that the membrane morphology paradigm shifted from the finger-like structure to the sponge-like structure on increasing the ethanol concentration in coagulant. The porosity of the fabricated membrane was under the required MD range and found to be 57.3% at 16 weight % of PVDF in DMAc solvent under a pure ethanol coagulant bath. Moreover, the top surface contact angle ranges from 85° to 115° on increasing the bath concentration from CBC 0 to CBC 100 at 16 weight % of PVDF in DMAc solvent.