• 제목/요약/키워드: Weibull distribution model

검색결과 387건 처리시간 0.024초

화양천 저서성 대형무척추동물의 물리적 서식처 적합도 산정 (Estimation on Physical Habitat Suitability of Benthic Macroinvertebrates in the Hwayang Stream)

  • 김예지;공동수
    • 한국물환경학회지
    • /
    • 제34권1호
    • /
    • pp.10-25
    • /
    • 2018
  • This study was conducted to estimate the habitat suitability of 17 benthic macroinvertebrate taxa in the Hwayang stream. Habitat Suitability Index (HSI) of benthic macroinvertebrates from the Hwayang stream was developed based on three physical habitat factors which include current velocity, water depth, and the substrate. The Weibull model was used as a probability density function to analyze the distribution of individual abundance by physical factors. The number of species and the total individual abundance increased along with the increase in current velocity. By means of Canonical Correspondence Analysis (CCA), the relative importance of each factor was determined in the following order: current velocity, water depth, and the mean diameter. The results depicted that, the most influential factor in the growth of benthic macroinvertebrates in the Hwavang system was current velocity. After comparing the analyzed results from the Hwayang stream with the resukts from the Gapyeong stream, the integrated HSI was drawn. The results indicated that current velocity and substrate had similar distributions of HSI in the two streams. This was due to the addition of unmeasured data from previous surveys, or the fact that benthic macroinvertebrates adapted to deeper waters in the Hwayang Stream. Most taxa showed a clear preference for a fast current velocity, deep water depth and coarse substrate except Baetiella, Epeorus, (mayflies), and Hydropsyche (caddisfly).

Copper Particle Effect on the Breakdown Strength of Insulating Oil at Combined AC and DC Voltage

  • Wang, You-Yuan;Li, Yuan-Long;Wei, Chao;Zhang, Jing;Li, Xi
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권2호
    • /
    • pp.865-873
    • /
    • 2017
  • Converter transformer is the key equipment of high voltage direct current transmission system. The solid suspending particles originating from the process of installation and operation of converter transformer have significant influence on the insulation performance of transformer oil, especially in presence of DC component in applied voltage. Under high electric field, the particles easily lead to partial discharge and breakdown of insulating oil. This paper investigated copper particle effect on the breakdown voltage of transformer oil at combined AC and DC voltage. A simulation model with single copper particle was established to interpret the particle effect on the breakdown strength of insulating oil. The experimental and simulation results showed that the particles distort the electric field. The breakdown voltage of insulating oil contaminated with copper particle decreases with the increase of particle number, and the breakdown voltage and the logarithm of particle number approximately satisfy the linear relationship. With the increase of the DC component in applied voltage, the breakdown voltage of contaminated insulating oil decreases. The simulation results show that the particle collides with the electrode more frequently with more DC component contained in the applied voltage, which will trigger more discharge and decrease the breakdown voltage of insulating oil.

가속수명자료에 대향 경험적 베이즈 비료연구 (Comparisons of Empirical Bayes Approaches to Censored Accelerated Lifetime Data)

  • 조건호;이우동
    • Journal of the Korean Data and Information Science Society
    • /
    • 제8권2호
    • /
    • pp.183-194
    • /
    • 1997
  • 이 논문의 목적은 제2종 중도절단자료된 가속수명 자료가 형상모수를 고정시킨 와이블분포를 한다는 가정에서 데이터에 대한 경험적베이즈 방법을 이용하여 분석하는데 있다. 이 논문에서는 적률추정법과 최우추정법을 이용한 경험적 베이지안 방법을 제안하고, Pathak등에 의해 제안된 경험적베이지안 방법과 비교한다. 특히, 인위적 자료를 이용한 모의 실험을 통하여 추정량들을 추정된 베이즈위험측면에서 비교한다.

  • PDF

의료용 할로겐램프의 가속수명시험에 관한 연구 (A Study on Accelerated Life Test of Halogen Lamps for Medical Device)

  • 정재한;김명수;임헌상;김용수
    • 품질경영학회지
    • /
    • 제41권4호
    • /
    • pp.659-672
    • /
    • 2013
  • Purpose: The purpose of this study was to estimate life time of halogen lamps and acceleration factors using accelerated life test. Methods: Voltage was selected as an accelerating variable through the technical review about failure mechanism. The test was performed at 14.5V, 15.5V and 16.5 for 4,471 hours. It was assumed that the lifetime of Halogen lamps follow Weibull distribution and the inverse power life-stress relationship models. Results: Mean lifetimes of pin and screw types were 19,477 hours and 6,056 hours, respectively. In addition, acceleration factor of two items are calculated as 4.8 and 2.2 based on 15.5V, respectively. Conclusion: The life-stress relationship, acceleration factor, and MTTF at design condition are estimated by analyzing the accelerated life test data. These results suggest that voltage was very important factor to accelerate life time in the case of halogen lamps and the life time of pin type is three times longer than screw type lamps.

전기이중층커패시터의 가속열화시험 (An Accelerated Degradation Test of Electric Double-Layer Capacitors)

  • 정재한;김명수
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제12권2호
    • /
    • pp.67-78
    • /
    • 2012
  • An electric double-layer capacitor(EDLC) is an electrochemical capacitor with relatively high energy density, typically hundreds of times greater than conventional electrolytic capacitors. EDLCs are widely used for energy storage rather than as general-purpose circuit components. They have a variety of commercial applications, notably in energy smoothing and momentary-load devices, and energy-storage and kinetic energy recovery system devices used in vehicles, etc. This paper presents an accelerated degradation test of an EDLC with rated voltage 2.7V, capacitance 100F, and usage temperature $-40^{\circ}C{\sim}65^{\circ}C$. The EDLCs are tested at $50^{\circ}C$, $60^{\circ}C$, and $70^{\circ}C$, respectively for 1,750hours, and their capacitances are measured at predetermined times by constant current discharge method. The failure times are predicted from their capacitance deterioration patterns, where the failure is defined as 30% capacitance decrease from the initial one. It is assumed that the lifetime distribution of EDLC follows Weibull and Arrhenius life-stress relationship holds. The life-stress relationship, acceleration factor, and $B_{10}$ life at design condition are estimated by analyzing the accelerated life test data.

Effect of biaxial stress state on seismic fragility of concrete gravity dams

  • Sen, Ufuk;Okeil, Ayman M.
    • Earthquakes and Structures
    • /
    • 제18권3호
    • /
    • pp.285-296
    • /
    • 2020
  • Dams are important structures for management of water supply for irrigation or drinking, flood control, and electricity generation. In seismic regions, the structural safety of concrete gravity dams is important due to the high potential of life and economic loss if they fail. Therefore, the seismic analysis of existing dams in seismically active regions is crucial for predicting responses of dams to ground motions. In this paper, earthquake response of concrete gravity dams is investigated using the finite element (FE) method. The FE model accounts for dam-water-foundation rock interaction by considering compressible water, flexible foundation effects, and absorptive reservoir bottom materials. Several uncertainties regarding structural attributes of the dam and external actions are considered to obtain the fragility curves of the dam-water-foundation rock system. The structural uncertainties are sampled using the Latin Hypercube Sampling method. The Pine Flat Dam in the Central Valley of Fresno County, California, is selected to demonstrate the methodology for several limit states. The fragility curves for base sliding, and excessive deformation limit states are obtained by performing non-linear time history analyses. Tensile cracking including the complex state of stress that occurs in dams was also considered. Normal, Log-Normal and Weibull distribution types are considered as possible fits for fragility curves. It was found that the effect of the minimum principal stress on tensile strength is insignificant. It is also found that the probability of failure of tensile cracking is higher than that for base sliding of the dam. Furthermore, the loss of reservoir control is unlikely for a moderate earthquake.

Fatigue Strength Assessment of Spot-Welded Lap Joint Using Strain Energy Density Factor

  • Sohn, Ilseon;Bae, Dongho
    • Journal of Mechanical Science and Technology
    • /
    • 제15권1호
    • /
    • pp.44-51
    • /
    • 2001
  • One of the recent issues in design of the spot-welded structure such as the automobile body is to develop an economical prediction method of the fatigue design criterion without additional fatigue test. In this paper, as one of basic investigation for developing such methods, fracture mechanical approach was investigated. First, the Model I, Mode II and Mode III, stress intensity factors were analyzed. Second, strain energy density factor (S) synthetically including them was calculated. And finally, in order to decide the systematic fatigue design criterion by using this strain energy density factor, fatigue data of the ΔP-N(sub)f obtained on the various in-plane bending type spot-welded lap joints were systematically re-arranged in the ΔS-N(sub)f relation. And its utility and reliability were verified by the theory of Weibull probability distribution function. The reliability of the proposed fatigue life prediction value at 10(sup)7 cycles by the strain energy density factor was estimated by 85%. Therefore, it is possible to decide the fatigue design criterion of spot-welded lap joint instead of the ΔP-N(sub)f relation.

  • PDF

Effects of Wind Generation Uncertainty and Volatility on Power System Small Signal Stability

  • Shi, Li-Bao;Kang, Li;Yao, Liang-Zhong;Qin, Shi-Yao;Wang, Rui-Ming;Zhang, Jin-Ping
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권1호
    • /
    • pp.60-70
    • /
    • 2014
  • This paper discusses the impacts of large scale grid-connected wind farm equipped with permanent magnet synchronous generator (PMSG) on power system small signal stability (SSS) incorporating wind generation uncertainty and volatility. Firstly, a practical simplified PMSG model with rotor-flux-oriented control strategy applied is derived. In modeling PMSG generator side converter, the generator-voltage-oriented control strategy is utilized to implement the decoupled control of active and reactive power output. In modeling PMSG grid side converter, the grid-voltage-oriented control strategy is applied to realize the control of DC link voltage and the reactive power regulation. Based on the Weibull distribution of wind speed, the Monte Carlo simulation technique based is carried out on the IEEE 16-generator-68-bus test system as benchmark to study the impacts of wind generation uncertainty and volatility on small signal stability. Finally, some preliminary conclusions and comments are given.

가평천 저서성 대형무척추동물의 물리적 서식처 적합성 평가 (Estimation on the Physical Habitat Suitability of Benthic Macroinvertebrates in the Gapyeong Stream)

  • 공동수;김아름
    • 한국물환경학회지
    • /
    • 제33권3호
    • /
    • pp.311-325
    • /
    • 2017
  • Habitat suitability index (HSI) of 17 benthic macroinvertebrate taxa, which were lotic insects of generic category except Potamanthidae in mayfly, was developed for three physical habitat factors (current velocity, water depth and substrate) based on an ecological monitoring in a Korean stream (Gapyeong). Weibull model was used as a probability density function to analyze the distribution of individual abundance related with physical factors, which showed it was so available. Number of species and total individual abundance increased along with the increase of current velocity and the mean diameter of substrate, and decreased along with the increase of water depth. Most taxa showed a clear preference for a fast current velocity, shallow water depth and coarse substrate except Ephemera, Potamanthidae (mayfly), and Plectrocnemia (caddisfly) which were rheophobic, potamophilic and lithophobious. Based on the canonical correspondence analysis, the relative importance of each factor was determined as follows: current velocity > substrate > water depth.

고온고습 시험을 이용한 실리콘 태양전지 모듈의 수명 예측 연구 (A study of lifetime prediction of PV module using damp heat test)

  • 오원욱;강병준;박노창;탁성주;김영도;김동환
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 추계학술대회 초록집
    • /
    • pp.63.1-63.1
    • /
    • 2011
  • To analyze the phenomenon of corrosion in the PV module, we experimented damp heat test at $85^{\circ}C$/85% relative humidity(RH) and $65^{\circ}C$/85% RH for 2,000 hours, respectively. We used 30 mini-modules designed of 6inch one cell. Despite of 2,000 hours test, measured $P_{max}$ is not reached failure which is defined less than 80% compared to initial $P_{max}$. Therefore, we calculate proper curve fitting over 2,000 hours. Data less than 80% $P_{max}$ is found and B10 lifetime is calculated by the number of failure specimens and weibull distribution. Using B10 lifetime that the point of failure rate 10% and Peck's model, the predictable equation of lifetime was derived under temperature and humidity condition.

  • PDF