• Title/Summary/Keyword: Wedge Pin

Search Result 6, Processing Time 0.022 seconds

Dorsal Wedge Osteotomy Using Bioabsorbable Pins for the Treatment of Freiberg's Disease (중족골두 무혈성 괴사에서 생체흡수성 핀으로 고정한 배측 쐐기 절골술)

  • Gong, Hyun-Sik;Baek, Goo-Hyun;Kim, Ji-Hyeong;Chung, Moon-Sang
    • Journal of Korean Foot and Ankle Society
    • /
    • v.9 no.1
    • /
    • pp.59-63
    • /
    • 2005
  • Purpose: To present the procedure and results of dorsal wedge osteotomy fixated by bioabsorbable polyglycolide pins for the treatment of symptomatic Freiberg's disease. Materials and Methods: From January 1997 to December 2002, six patients with Freiberg's disease underwent dorsal wedge osteotomy of the metatarsal neck to bring the healthy plantar part of the metatarsal head into articulation. Bioabsorbable polyglycolide pins were used for the fixation and short-leg walking cast was applied for 4 weeks. Results: All patients returned to full daily activities without pain in three months after the operation. Radiographically, solid healing of the osteotomy was observed at average ten weeks. The active range of motion of the metatarsophalangeal joint increased by a mean gain of 30 degrees, and no complication such as displacement, osteolysis or sinus formation was observed. Conclusion: Dorsal wedge osteotomy fixated by bioabsorbable pins for patients with symptomatic Freiberg's disease is effective procedure that provides relatively early range of motion exercise and avoids second procedure for implant removal.

  • PDF

A Study on Application for Deck Plate Substitute Type Wood System Form of Frame Type Parking Lot (골조형 주차장의 Deck Plate 대체형 목제 시스템 거푸집 적용성 연구)

  • Shin, Yong-Jae;Shin, Woon-Sik;Heo, Jae-Won;Lim, Nam-Gi
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2006.11a
    • /
    • pp.123-126
    • /
    • 2006
  • Existing Deck Plate for a one of system forms, there is various advantage and application actual results increasing rapidly. But design of deck is depending on engineering data collections or design data on deck manufacture ordinarily. When construct, is responsible for deflection occurrence, And Because confirmation of crack occurrence region is impossible, there is difficulty of repair, reinforcement about crack and water leakage. According to got following conclusion as result that economic performance, preservation administration and repair reinforcement develops easy using steel truss snap tie by wedge pin on coating plywood that is slab Panel Wood System Form method of construction there is Deck Plate's advantage. (1) In stab lower part is exposed disjointing in which a criminal is fastened to be interrogated after construction acceptance and repair, reinforcement of crack is possible (2) Construction cost curtailment effect of about 29.2% than conventional type and about 10% than deck plate (3) Construction period reduction of about 3 day than conventional type and about 0.3 day than deck plate (4) Labor curtailment effect more than about $29{\sim}50%$ from conventional type

  • PDF

Surgical Correction of an Antebrachial Deformity with Severe External Rotation in Two Dogs (심각한 외측 회전을 동반한 전완 기형의 외과적 교정 치료 2 증례)

  • Yoon, Hun-Young;Roh, Mi-Young;Jeong, Soon-Wuk
    • Journal of Veterinary Clinics
    • /
    • v.28 no.3
    • /
    • pp.328-331
    • /
    • 2011
  • Two dogs presented to the Dueckso Animal Hospital with a history of intermittent lameness of the left forelimb. On physical examination, a visible antebrachial deformity that resulted in gross external rotation of approximately $90^{\circ}$ was observed in two dogs. Medial-lateral radiographic views revealed distal ulnar subluxation, cranial bowing of the radius, radial and ulnar shortening, and external rotation of the paw. A distal ulnar ostectomy and distal radial closing wedge osteotomy were performed in two dogs. A proximal ulnar osteotomy was performed, adjacent to the elbow joint in case 1. Then, the osteotomized site was supported with an intramedullary pin. A T-plate and cortical screws were applied to the proximal and distal radial segments after derotating the distal segment internally. Postoperative radiographic view verified the correction of the angular deformity in two dogs. The follow-up was completed by physical examination 6 and 10 months after surgery respectively. There was no evidence of lameness of the left forelimb in two dogs. Gross observation of the limb revealed an apparent appropriate correction of the rotational and angular deformity in two dogs.

Dynamic Stability of a Railroad Bridge Using Bi-prestressing Technology (바이프리스트레싱 기법을 이용한 철도교량의 동적안정성)

  • Choi, Sanghyun;Lee, Changsoo;Lim, Jaehoon;Lee, Seungjoon;Yang, Sungdon
    • Journal of the Society of Disaster Information
    • /
    • v.9 no.2
    • /
    • pp.188-194
    • /
    • 2013
  • As the high speed railroad line increases, researches on developing a more economic high speed railroad bridge system have been actively conducted. In this paper, a new type of prestressed concrete girder based on the bi-prestressing technique, which can introduce additional prestress, is presented. The additional prestress can be introduced using a wedge-shaped pin bar into the upper part of the girder section. The applicability of the new girder technique to the high speed railroad bridge is verified via the dynamic stability analysis. Dynamic moving load analyses using the KTX train load are conducted on bridge systems with the span lengths of 30m, 35m, and 40m, respectively. The results of the analysis show that all bridge systems satisfy the limits prescribed in the design specifications to ensure structural stability, driving safety, and ride quality.

Therapeutic Proton Beam Range Measurement with EBT3 Film and Comparison with Tool for Particle Simulation

  • Lee, Nuri;Kim, Chankyu;Song, Mi Hee;Lee, Se Byeong
    • Progress in Medical Physics
    • /
    • v.30 no.4
    • /
    • pp.112-119
    • /
    • 2019
  • Purpose: The advantages of ocular proton therapy are that it spares the optic nerve and delivers the minimal dose to normal surrounding tissues. In this study, it developed a solid eye phantom that enabled us to perform quality assurance (QA) to verify the dose and beam range for passive single scattering proton therapy using a single phantom. For this purpose, a new solid eye phantom with a polymethyl-methacrylate (PMMA) wedge was developed using film dosimetry and an ionization chamber. Methods: The typical beam shape used for eye treatment is approximately 3 cm in diameter and the beam range is below 5 cm. Since proton therapy has a problem with beam range uncertainty due to differences in the stopping power of normal tissue, bone, air, etc, the beam range should be confirmed before treatment. A film can be placed on the slope of the phantom to evaluate the Spread-out Bragg Peak based on the water equivalent thickness value of PMMA on the film. In addition, an ionization chamber (Pin-point, PTW 31014) can be inserted into a hole in the phantom to measure the absolute dose. Results: The eye phantom was used for independent patient-specific QA. The differences in the output and beam range between the measurement and the planned treatment were less than 1.5% and 0.1 cm, respectively. Conclusions: An eye phantom was developed and the performance was successfully validated. The phantom can be employed to verify the output and beam range for ocular proton therapy.

Comparative Study on the Urohyal of the Subfamily Gobioninae of Korea (한국산(韓國産) 모래무지아과(亞科)(Gobioninae) 어류의 미설골(尾舌骨)에 대한 비교연구)

  • Kim, Ik-Soo;Kang, Eon-Jong
    • Korean Journal of Ichthyology
    • /
    • v.1 no.1_2
    • /
    • pp.24-34
    • /
    • 1989
  • We reexamined the skulls of 14 gobionine genera of Korea to study taxonomic status of Gobioninae. The character transformation series found in the morphology of urohyal was very distinct among other skeletal characters. The gobioninae fishes of Korea were divided into 4 groups based on their morphology of urohyal as follows ; 1. Coreoleuciscus, Gnathopogon group ; The horizontal plate of urohyal has a ellipse shape with posterior edge wedged and the length is longer than that of vertical plate. 2. Hemibarbus, Squalidus group ; The horizontal plate has a elongated rhombeus shape with posterior edge pointed and the length is shorter than that of vertical plate. 3. Sarcocheilichthys, Pseudopungtungia, Pseudorasbora, Pungtungia group ; the horizontal plate has a expanded rhombeus shape, the length is longer than that of vertical plate, the hypohyal attatchment is not bifurcated, and the profile of the horizontal and vertical plate curved ventrally. 4. Ladislavia, Gobiobotia, Abbottina, Hicrophysogobio, Pseudogobio, Saurogobio group ; The horizontal plate has a pin or wedge shape expanded anteriorly, the length is shorter than that of vertical plate, and the hypohyal attatchment is thickened laterally. This results agreed with those by the adductor mandibulae complex, the geniohyoideus of cephalic muscles, and the cephalic-lateral line canals.

  • PDF