• Title/Summary/Keyword: Wear volume

Search Result 351, Processing Time 0.022 seconds

Macroscopic Wear Characteristics of Ceramics under the Rolling Contact (구름접촉시 세라믹의 거시적 마모특성)

  • Kim, Seock-Sam;Koto, Kohji;Hokkirigawa, Kzauo
    • Tribology and Lubricants
    • /
    • v.5 no.1
    • /
    • pp.28-35
    • /
    • 1989
  • The wear tests of ceramic materials in dry rolling contact were carried out at room temperature to investigate their macroscopic wear characteristics. Both point contact and line cootact were adapted in the wear tests of them. Ceramic materials used in these tests were silicon nitride, silicon carbide, cermet of TiN and TiC, titania, and alumina. The wear test of the bearing steel was carried out to compare to the wear test results of the ceramic materials. The results showed that the wear rate of silicon nitride was smaller than any other ceramic materials and bearing steel. In the steady wear, the wear volume of ceramic materials increases linearly with the rolling distance. It was also found from the experimental results that fracture toughness and surface roughness dominate the wear process of ceramic materials in dry rolling contact.

A STUDY ON THE RESISTANCE OF WEAR AND CYTOTOXICITY OF THE TITANIUM SURFACE AFTER FILM DEPOSITIONS (박막증착시 티타늄 표면의 마손저항도와 세포독성에 관한 연구)

  • Kim Hyung-Woo;Kim Chang-Whe;Kim Yung-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.1
    • /
    • pp.84-95
    • /
    • 2001
  • Titanium is widely used in dentistry for its low density, high strength, fatigue resistance, corrosion resistance, and biocompatibility. But it has a tendency of surface damage under circumstance of friction and impact for its low hardness of the surface. Coating is one of methods fir increasing surface hardness. Its effect is to improve surface physical characteristics without change of titanium. Diamond-like carbon and titanium nitride are known for its high hardness of the surface. So that this study was aimed at the wear test and the cytotoxicity test of the commercially pure titanium and Ti-6Al-4V alloy which were deposited by diamond-like carbon film or titanium nitride film to acertain improvement of the surface hardness and the biocompatibility. A disk (25mm diameter, 2mm thickness) was made of commercially pure titanium and Ti-6Al-4V alloy and these substrates were deposited by diamond-like carbon film or titanium nitride film. Diamond-like carbon film was deposited by the method of radiofrequency plasma assisted chemical vapor deposition and titanium nitride film was deposited by the method of reactive arc ion plating. Then these substrates were tested about wear characteristics by the pin-on-disk type wear tester in which ruby ball was used as a wear causer under the load of 32N, The fracture cycles were measured by rotating the substrates until their films were fractured. The wear volume was measured after 150 cycles and 3,000 cycles using surface profiler. The cytotoxicity test was peformed by the method of the MTT assay. The results were as follows : 1. In the results of the wear volume test, commercially pure titanium and titanium alloy which were coated by diamond-like carbon film or titanium nitride aim had higher resistance against wear than the substrates which were not coated by any films (P<0.05). 2. In the results of the fracture cycle test and the wear volume test, diamond-like carbon film had higher resistance against wear than titanium nitride film (P<0.05). 3. In both coatings of diamond-like carbon aim and titanium nitride film, Ti-6Al-4V alloy had higher resistance against wear than commercially pure titanium (P<0.05) 4. In the results of the cytotoxicity test, diamond-like carbon film and titanium nitride film had little cytotoxicity as like commercially pure titanium or Ti-6Al-4V alloy (P>0.05).

  • PDF

Microstructure and Wear Behavior of $SiC_p-reinforced$ Aluminum Matrix Composites Fabricated by Spray Casting Process (분사주조한 $SiC_p$ 입자강화 알루미늄 복합재료의 미세조직과 마멸특성)

  • Park, Chong-Sung;Kim, Myung-Ho
    • Journal of Korea Foundry Society
    • /
    • v.15 no.6
    • /
    • pp.574-587
    • /
    • 1995
  • The $SiC_p-reinforced$ preforms fabricated by spray casting process were hot-extruded and subsequently T6-treated, and the morphology of the silicon phase and the grain size for these preforms and extruded samples were examined by Image Analyzer. Experimental observation revealed that with increase in volume percent of SiC particles, the grain size and silicon phase of the $Al-Si/SiC_p$ composites become finer, the shape of Si phase is changed from blocky to granular type, and aspect ratio of Si phase tend to become unity. Wear-tests with various sliding velocities, show that the wear resistance of spray cast specimen is increased remarkably compare to the permanent mold cast specimen at the sliding velocity range of $1.98{\sim}2.38m/sec$.. Microstructural observations for the worn surfaces of specimens revealed that wear resistance of Al-Si alloys at certain sliding velocities could be improved not only by the fine grain size of aluminum matrix but also the fine size and granular shape of silicon phases. The wear resistance of $SiC_p$ reinforced aluminum composites was found to be sensitive to the volume percentage of the reinforcing particles. The worn surfaces with various sliding velocities, show that change in wear mechanism seems to occur at the sliding velocity of near 2m/sec for all samples, and such a change in mechanism is delayed with increase in $SiC_p$ volume fraction.

  • PDF

Effect of Lubricant Addition in Terms of Volume Fraction on Fabrication of Cu/Sn Bonded Diamond Micro Blades (다이아몬드 마이크로 블레이드 제조에 있어 부피비의 관점에서 본 윤활제 첨가 효과)

  • Moon, Jong-Chul;Kim, Song-Hee
    • Journal of the Korean institute of surface engineering
    • /
    • v.43 no.1
    • /
    • pp.41-45
    • /
    • 2010
  • The effect of $MoS_2$ and graphite content on wear resistance and mechanical properties of Cu/Sn bonded diamond micro blades was comparatively investigated in terms of volume and weight fraction. For the evaluation of endurance and cutting performance, instantaneous electric power consumption and cumulative wear loss during cutting glass work piece at constant velocity were measured with the micro blades of the wide range of lubricant content. The energy consumption of blades for glass cutting decreased with the content of lubricants. Wear amount of blade in volume increased with the amount of lubricant addition. It was found to be relevant to the decrease in flexural strength and hardness with the amount of lubricants. With the same amount of lubricant content in volume fraction $MoS_2$ showed superiority in mechanical properties and cutting performance than graphite while graphite could result in stronger effect on lowering electric consumption during cutting work piece for the same weight percent fraction than $MoS_2$ because of lower density.

Analysis of Wear Characteristics for Sliding Members of Hydraulic Rotary Actuator (유압피스톤 습동재료의 마멸특성 해석)

  • 김성희;김동호;이광영;박흥식;전태옥
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1999.06a
    • /
    • pp.101-108
    • /
    • 1999
  • This paper was undertaken to do morphological analysis of wear particles for sliding members hydrauric rotary acuator. The lubricating wear test was performed under different experimental conditions using the wear test device and wear specimens of the pin on disk type was rubbed in paraffinic base oil by three kinds of lubricating materials, varying applied load, sliding distance. The four shape parameters (50% volumetric diameter, aspect, roundness and reflectivity) are used for morphological analysis of wear particles. The results showed that the four shape parameters of wear particles depend on a kind of the lubricating materials. It was capable of presuming wear volume for three kinds of materials on driving time.

  • PDF

Prediction of Wear Depth Distribution by Slurry on a Pump Impeller

  • Sugiyama, Kenichi;Nagasaka, Hiroshi;Enomoto, Takeshi;Hattori, Shuji
    • International Journal of Fluid Machinery and Systems
    • /
    • v.2 no.1
    • /
    • pp.21-30
    • /
    • 2009
  • Slurry wear with sand particles in rivers is a serious problem for pump operation. Therefore, a technique to predict wear volume loss is required for selecting wear resistant materials and determining specifications for the maintenance period. This paper reports a method for predicting the wear depth distribution on the blade of an impeller. Slurry wear tests of an aluminum pump impeller were conducted. Prediction results of wear depth distribution approximately correspond with the results of slurry wear tests. This technique is useful for industrial application.

The Evaluation on Wear Characteristics of the Crane Sheave (크레인용 시브 강재의 마멸특성 평가)

  • Park Yongjae;Ryu Jungbuk;Kim Seocksam
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.306-311
    • /
    • 2004
  • The sliding wear characteristics of the crane sheave were investigated using a pin-on-disk rig tester The experiment was conducted using a high carbon steel wire that was upper material, also carbon steel castings and carbon steel for machine structural use that was disk material. There are various operating conditions in this work. At the room temperature, we carried out the wear test under a grease lubrication. The results of wear test showed that carbon steel for machine structural use have lower wear volume, also the wear curves are linearly increased with increasing of sliding velocity The wear mechanism of a disk is the abrasive, adhesion, and fatigue wear under lubrication.

  • PDF

Monitoring of Micro-Drill Wear by Using the Machine Vision System (머신비전 시스템을 이용한 마이크로드릴 마멸의 상태감시)

  • Choi Young-Jo;Chung Sung-Chong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.30 no.6 s.249
    • /
    • pp.713-721
    • /
    • 2006
  • Micro-drill wear deteriorates accuracy and productivity of the micro components. In order to improve productivity and qualify of micro components, it is required to investigate micro-drill wear exactly. In this study, a machine vision system is proposed to measure the wear of micro-drills using a precision servo stage. Calibration experiments are conducted to compensate for the machine vision system. In this paper, worn volume, area and length are defined as wear amounts. Micro-drill wear is reconstructed as the 3D topography and the quantized wear amount by using the shape from focus (SFF) method and wear parameters. Experiments have been conducted with HSS twist micro-drills and SM45C carbon steel workpieces. Validity of the proposed machine vision system is confirmed through experiments.

Fretting Wear Mechanisms of TiN Coated Nuclear Fuel Rod Cladding Tube (TiN 코팅한 핵연료봉 피복재의 프레팅 마멸기구)

  • 김태형;성지현;김석삼
    • Tribology and Lubricants
    • /
    • v.17 no.6
    • /
    • pp.453-458
    • /
    • 2001
  • The fretting wear of a nuclear fuel rod it a dangerous phenomenon. In this study, TiN coating was used to reduce the fretting wear of Zircaloy-4 tube, a nuclear fuel rod cladding material. TiN coating is probably one of the molt frequently and successfully used PVD coatings for the mitigation of fretting wear. The fretting tester was designed and manufactured for this experiment. The number of cycles, slip amplitude and normal load were selected as main factors of fretting wear. The results of this research showed that wear volume was improved 1.3∼3.2 times with TiN coating. The worn surfaces were observed by SEM. Wear mechanism at lower slip amplitude was the brittle cracks and rupture of TiN coating. However, adhesive and abrasive wear were mainly observed on most surfaces at higher slip amplitude.

Morphological Analysis of Wear Particles for Sliding Members of Hydraulic Rotary Actuator (유압피스톤 모터용 습동재료의 마멸분 형태특징 해석)

  • 김성희;조연상;서영백;박흥식;전태옥
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 1999.05a
    • /
    • pp.87-92
    • /
    • 1999
  • This paper was undertaken to do morphological analysis of wear particles for sliding members hydraulic rotary actuator. The lubricating wear test was performed under different experimental conditions using the wear test device and wear specimens of the pin on disk type was rubbed in paraffinic base oil by three kinds of lubricating materials, varying applied load, sliding distance. The four-shape parameters (50% volumetric diameter, aspect, roundness and reflectivity) are used for morphological analysis of wear particles. The results showed that the four shape parameters of wear particles depend on a kind of the lubricating materials. It was capable of presuming wear volume for three kinds of materials on driving time.

  • PDF